Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Definition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectrally Stabilized Interface Capturing Formulation and Implementation in Nek5000/NekRS

This report documents the formulation of a novel level-set method for incompressible two-phase flows in the continuous Galerkin (CG) high order spectral element framework. The overall method hinges on a novel implementation of the spectral vanishing viscosity (SVV) operator for the stabilization of linear/non-linear hyperbolic problems. The multidimensional SVV convolution kernels, which in essence, have a similar effect as a high pass filter applied to the derivatives, are formulated by exploiting the tensor product form, analogous to the construction of the usual stiffness matrix system. The resulting kernels are directionally decoupled and ensure a linear, symmetric positive definite, elliptic matrix operator. The SVV formulation is demonstrated to provide a robust stabilizing mechanism through challenging linear and non-linear hyperbolic problems, including problems pertinent to the level-set formulation. The two-phase framework conceptualized herein is based on the conservative level-set (CLS) method which represents the interface between the fluids by the 0.5 iso-contour of the smoothed Heaviside function. The CLS method is augmented with a preconditioning procedure for interface normals using the signed distance function which precludes the manifestation of spurious oscillations in the vicinty of the interface. Further, the existing mixed explicit-implicit approach for the solution of Navier-Stokes equations in Nek5000, as described in Tomboulides et al, is augmented with a pressure coefficient splitting approach for the Poisson equation, which greatly accelerated the convergence of pressure solver for two-phase systems with large density ratio. The robustness and accuracy of the overall two-phase method is demonstrated through canonical challenging problems involving high density and viscosity ratios, with and without surface tension. The two-phase formulation is wholly implemented in Nek5000 and the SVV stabilization method is implemented in NekRS, which is the essential precursor to the two-phase framework, undergoing active development.

97 MATHEMATICS AND COMPUTING↗

Regime Characterization of Offshore Wind Resource Using Unsupervised Learning

Predictability of wind resource conditions is critical for offshore wind design and operations. While many studies of extreme wind conditions focus on specific events such as low-level jets or ramps, these rely on threshold definitions that limit generality. Here we present a data-driven framework that combines principal component analysis (PCA), self-organizing maps (SOM), and k-means clustering to classify wind resource conditions as typical and anomalous from climatological data. Anomalies are defined not by fixed thresholds but by flagging samples located far from SOM node centers inside the baseline SOM structure. This reframes extremes as rare ebents and hence, likely difficult to anticipate by numerical weather prediction models. We applied this approach to 23 years (2000–2022) of hourly profiles from the NOW-23 hindcast model at the Humboldt Wind Energy Area. Classification is conducted on a feature space consisting of 10 m wind speed and direction, bulk shear and veer across 30–270 m, and a low-level jet index. Dimensionality reduction is achieved through PC. A 2 × 3 OM lattice trained on the PCA vectors identified six baseline regimes spanning weak to strong flow states. High quantization-error profiles are identified and re-clustered into four anomalous regimes. The baseline regimes exhibited clear seasonal and diurnal cycles. Meanwhile, the anomalous regimes represented <10 % of all hours but showed distinct combinations of speed, shear, and veer, when compared to the baseline regimes. Anomalous regimes are typically short-lived (~few hours), yet their transitions can lead to hub-height wind changes of −18 to +9 m s -1 . For a representative 15 MW turbine, these shifts imply rapid swings in capacity factor from near-full output to negligible generation. Validation with lidar buoy data showed 51% agreement in SOM labels across ~6,000 overlapping hours, with most mismatches confined to adjacent speed classes. HRRR comparisons further revealed that anomalous regimes were disproportionately associated with forecast biases exceeding 5 m s -1 . Together, these results reframe extremes in offshore wind from absolute maxima or minima to weather states that are difficult to anticipate from models.

17 WIND ENERGY↗

Virtual Power Plants and Distributed Energy Resource Management Systems

Virtual Power Plants (VPPs) are aggregations of DERs that can balance electrical loads and provide utility-scale and utility-grade grid services like a traditional power plant. This presentation covers VPP definition, State-of-the-Art, Grid Architectures, Example VPP studies, VPP Standards, and VPP Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fundamentals of Resource Adequacy for Modern Power Systems

This webinar covers and introduction to power system resource adequacy, examining definitions, metrics, an overview of probabilistic methods, incentives and capacity credits, storage modeling, and evolving practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NARUC Resilience Framework

The NARUC Resilience Framework provides state regulators and other key stakeholders with a structured approach to considering policies and programs that will enhance grid resilience amid evolving technological, environmental and economic challenges. This Framework consolidates insights from nationwide workshops and peer discussions into six actionable components: (1) setting goals and objectives, (2) leveraging use cases, (3) establishing shared definitions, (4) ensuring inclusive process leadership, (5) addressing critical design questions, and (6) guiding implementation. This Framework is intended as a strategic tool for regulators to navigate resilience investments, prioritize affordability, integrate stakeholder needs, and foster collaboration across agencies, all while balancing cost-effectiveness with societal and economic resilience outcomes. By presenting a structured approach to decision-making rather than prescriptive solutions, the Framework supports nuanced, jurisdiction-specific resilience planning and is adaptable to the dynamic demands of modern energy systems

24 POWER TRANSMISSION AND DISTRIBUTION↗

The User Guide for the ComPro Database

An extensive database of glass composition and durability data has been compiled at Savannah River National Laboratory to support the development of nuclear waste glasses. This database is referred to as the Glass Composition-Properties Database (ComPro). The ComPro Database, Revision 3, contains 14,134 total rows of data and 125 columns of composition, durability, as defined by the Product Consistency Test, and other fabrication and characterization information, if available, for each glass. Of the 14,134 total rows, 8,484 rows have been classified as “Model” data and 5,650 rows have been classified as “Non-Model” data. An integral supplement to the ComPro database is the User Guide. The User Guide was developed as a tool to aid the End User in a more effective use of the ComPro database. The User Guide provides a road-map of the specific datasets that comprise the ComPro database (both “Model” and “Non-Model” data) as well as a technical basis for the terminology and definitions the End User will encounter. In this report, a general description of the format and information contained in the User Guide is provided. In addition, specific terminology used in the User Guide is also discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

What Are Ontologies and When Should They Be Used?

Data without description is at best unusable, and at worst, misused. If we do not understand the assumptions and meaning of our data, we are unable to confidently use it. Data today is largely described within a database’s schema, detailing structure and primitive datatypes as part of a relational model, but if we require assurance some data value can be correctly evaluated alongside others beyond the immediate systems in which they are defined, a more portable, richer semantics is needed. Ontologies define knowledge unambiguously across systems and establish the means to reason upon said knowledge using logical inference. They model neutral domains of information rather than data definitions from software or databases that would only serve to enrich a single system’s idiosyncrasies. In this paper, we take a casual stance to explore what ontologies are, how they are built, why they are useful, and when they should be used.

97 MATHEMATICS AND COMPUTING↗

Effects of Salt Concentration, Ionic Strength, and Water Activity on the Growth of a WIPP Archaeal Isolate, Halobacterium sp.

An extremely halophilic archaeon ( Halobacterium sp., WIPP strain), isolated from WIPP halite, was tested for its ability to grow in media containing various combinations of sodium and magnesium chloride that influenced overall ionic strength and water activity. Halobacterium sp. grew well in most tested salt combinations, and its growth appeared to depend more upon the relative contribution of sodium to overall ionic strength than on other parameters. Growth rates were highest when media consisted of at least 2 M NaCl and lowest when NaCl dropped below 20% of the ionic strength (usually less than 0.5 M). High magnesium concentrations ( 1 and 1.5 M MgCh 2 ) did not prevent Halobacterium sp. growth, as long as the sodium contribution was sufficient. Water activity was not a definitive factor in determining growth, because this value did not reach an extreme lower limit in the experimental media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainty in Synthetic Tropical Cyclone Hazard and Risk Estimates: Insights from RAFT, CHAZ, MIT, STORM, and CLIMADA

We synthesize five complementary tropical cyclone (TC) hazard frameworks—RAFT (physics-based machine learning), CHAZ and MIT (statistical–dynamical), STORM (fully statistical), and CLIMADA (observation-driven resampling)—to characterize uncertainty in wind-related TC metrics relevant to energy applications. All datasets and the IBTrACS observational record are harmonized to a common 6-hourly, 2.5° grid. We compare basin-wide and coastal properties using consistent definitions for TC frequency, mean and maximum intensity, 24-hour intensification, and 6-hour translation speed, and quantify agreement with Pearson r, RMSE, and Kling–Gupta efficiency (KGE) alongside resampling-based confidence intervals. CLIMADA is included for basin context but excluded from coastal skill scoring because it resamples historical IBTrACS; if supplied with projected future tracks from an external hazard model, CLIMADA can be used to simulate future TC scenarios. Results show robust, cross-model signals: (i) a corridor of activity from the tropical Atlantic through the Caribbean into the Bahamas and western subtropical Atlantic; (ii) a meridional dipole in 24-hour intensification (low-latitude strengthening, subtropical weakening); and (iii) a transition from slower tropical motion to faster midlatitude translation. Coastal winds (mean and maximum) consistently cluster from the eastern Gulf into the Bahamas–western Atlantic transition. The largest structural spread occurs in the amplitude and footprint of lifetime maximum intensity and, secondarily, in translation speed; intensification exhibits similar central behavior across frameworks with variability in extremes. Translation speed shows the most uniform coastal agreement. These findings provide a decision envelope for wind-focused risk screening and clarify where uncertainty should be carried forward; wind-only results represent a lower bound on total hazard, motivating integration of surge and rainfall modules and a companion, asset-level damage analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analog Systems for Edge Optimization

Over the past decade, analog computing has the subject of substantial research interest providing a path toward improved computational efficiency in the post-Dennard era. Analog matrix vector multiplication (MVM) accelerators provide a popular approach given the ubiquity of MVM operations in numerous applications. However, historically analog computing systems can struggle with applications requiring high precision due to the inherent susceptibility of these systems to analog non-idealities. Therefore, prior work on analog systems has focused either on applications known to be tolerant of limited precision (e.g., neural network inference), or using expensive techniques to emulate high-precision using many analog MVM operations. In this work, we propose an alternative approach. Motivated by recent advances in inexact nonlinear solvers and optimizers, we explore the potential of co-designing optimization algorithms which can take full advantage of the fundamentally inexact analog MVM operations. To enable these co-designed algorithms we also develop a general mathematical theory of the precision and energy efficiency of analog operations, and a new system architecture for tightly-coupled analog and digital computation. Finally, we examine the applicability of analog computing to a wider class of symmetric positive definite systems and find potential in using analog operations as a sparse approximate inverse preconditioner. With these core innovations, this project provides a path toward effectively implementing optimization algorithms on power-constrained autonomous and semi-autonomous systems.

97 MATHEMATICS AND COMPUTING↗

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS↗

CIE Analysis Process for Engineered Systems

"CIE Analysis Process for Engineered Systems" outlines a comprehensive methodology for integrating Cyber-Informed Engineering (CIE) principles into both new and existing engineered systems. Sponsored by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER), the process aims to achieve cyber-informed decisions by producing functional security requirements for new systems and retrofitting existing systems to mitigate digital risks. The document details a step-by-step approach, including mission and function definition, digital asset awareness, consequence analysis, and mitigation analysis. It emphasizes the importance of documenting mechanical, electrical, programmable, and network components to protect system functions and provides examples and considerations for each step. The ultimate goal is to ensure that engineered systems remain resilient against cyber threats, maintaining safety, performance, and reliability.

42 - ENGINEERING↗

Connectivity Troubleshooting Guide for Advanced Electricity Meters

This guide is designed to walk users through a troubleshooting process for disconnected advanced electricity meters. The guide centers on two connectivity troubleshooting decision trees related to power issues and network connectivity issues, respectively. Additionally, it contains additional background information such as definitions, diagrams, and checklists that can help a user prepare to troubleshoot meter connectivity issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PSU ESI Review

A guide to developing an Energy Service Interface (ESI) was created as part of the Grid Modernization Laboratory Consortium 2.5.2 ESI project. The approach applies device-agnostic and service-oriented ESI principles and leverages documents such as the Interoperability Maturity Model and Common Grid Service Definitions to provide a methodology to review, develop, and update standards and profiles to engage distributed energy resources (DER) to provide grid services. This document evaluates the ESI developed by Portland State University’s Power Engineering Group under the Electric Grid of Things project funded by the U.S. Department of Energy. The evaluation explores the compliance of this specific implementation with the GMLC ESI principles to provide an example of an ESI profile and gap analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Security of DERs and Grid Edge Technologies [Slides]

Distributed energy resources (DERs) offer significant value for incorporating diverse generation technologies and improving reliability. They also present a new set of cybersecurity challenges. The move of generation to the grid edge can also mean more distributed control systems and expanded communication networks, resulting in an increase in attack surface. This presentation will discuss definitions and essential terms related to DERs; developments and deployment trends for DERs; recent cyber attacks on operational technology and industrial systems; cyber risk arising from distributed grid resources; and ways in which standards may help mitigate some of these risks.

24 POWER TRANSMISSION AND DISTRIBUTION↗