Measurements and implications of vortex motions using two flow-visualization techniques

The present comparative study of two different, but complementary flow-visualization techniques, which yield different interpretations of vortex-migration distance and lifetime, gives attention to the difficulty of determining vortex evolution and lifetime from flow-visualization measurements. The techniques involved the release of a fluorescent dye and of neutrally buoyant particles in a water-filled towing tank. Vortices are found to migrate farther, and last longer, when visualized with neutrally buoyant particles rather than with dyes.

Delisi, Donald P.↗

Methods for obtaining and reducing experimental droplet impingement data on arbitrary bodies

Experimental water droplet impingement data are used to validate particle trajectory computer codes used in the analysis and certification of aircraft de-icing/anti-icing systems. Water droplet impingement characteristics of aerodynamic surfaces are usually obtained from wind-tunnel dye tracer experiments. This paper presents a dye tracer method for measuring water droplet impingement characteristics on arbitrary geometries and a new data reduction method, based on laser reflectance measurements, for extracting impingement data. Extraction of impingement data has been a very time-consuming process in the past. The new data reduction method developed is at least an order of magnitude more efficient than the method previously used. The accuracy of the method is discussed and results obtained are presented.

Papadakis, Michael↗

Colorimetric Detection Of Substances In Liquids And Gases

Thin polymer films containing solvatochromic dyes used as sensing elements to detect substances dissolved in liquids and gases. Dyes do not react with liquids in which dissolved, but do respond to changes in chemical compositions by changing color. Concentration determined visually by comparison of color with predetermined standard chart, or spectrophotometrically.

Harris, J. Milton↗

Lidar Probing of the Mesosphere: Simultaneous Observations of Sporadic Sodium and Iron Formations, Calcium Ion Layers, Neutral Temperature and Winds

Meteoritic ablation in the upper atmosphere is the commonly accepted source of the mesospheric metals between 80 and 105 km. The vertical and temporal behavior of some of these metals can be probed with high accuracy and resolution using resonance fluorescence lidar techniques. Of considerable interest in recent years has been the sporadic and rapid formation of thin, dense enhancements in these metallic layers. Since late Mar. 1991, the UIUC CEDAR lidar system, located at the Urbana Atmospheric Observatory, has been routinely operating at the Fe resonance line of 372 nm in order to probe the mesospheric Fe layer. In Nov. 1991, the capability to investigate mesospheric Ca(+) at the resonance line of 393.4 nm was added. The lidar's eximer-pumped dye laser uses Exciton QUI laser dye dissolved in p-dioxane, which can lase at both the Fe and Ca(+) frequencies. Various aspects of this investigation are discussed.

Kane, Timothy J.↗

Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

Quagliaroli, T. M.↗

Polymeric-host sulforhodamine-B lasers - Doubled Nd:YAG pumped

Solid-state dye lasers, pumped by a doubled Nd:YAG laser, were evaluated as a function of concentration, output coupler reflectivity and oscillator dimensions. A slope efficiency of up to 62 pct was achieved. A maximum irradiance of 59 MW/sq cm to the dye laser cavity was achieved.

Gettemy, D. J.↗

Chemical Dosimeter Tube With Coaxial Sensing Rod

Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

Lueck, Dale E.↗

Noise amplitude measurements of single-mode CW lasers at radio frequencies

This letter presents the results of noise measurements for a variety of single-longitudinal-mode CW lasers (Ar/+/, standing-wave-dye, and ring-dye) that are commercially available. A quantitative comparison of the total output power fluctuations detected over the 7-300 MHz region (3 dB points) is presented.

Herring, G. C.↗

Concentration measurements in an axisymmetric jet using laser-induced fluorescence

Errors associated with the use of an image processing technique to correct images of an axisymmetric jet produced by laser-induced fluorescence are analyzed. In particular, attention is given to errors related to the alignment of the optical system, spreading of the laser light sheet, laser light attenuation due to light absorption by the fluorescent dye, and solubility effects. Although the above effects are negligible in the case of a small low-concentration jet, they are not negligible in all fluorescent dye experiments.

Shoe, B.↗

Single event effects and laser simulation studies

The single event upset (SEU) linear energy transfer threshold (LETTH) of radiation hardened 64K Static Random Access Memories (SRAM's) was measured with a picosecond pulsed dye laser system. These results were compared with standard heavy ion accelerator (Brookhaven National Laboratory (BNL)) measurements of the same SRAM's. With heavy ions, the LETTH of the Honeywell HC6364 was 27 MeV-sq cm/mg at 125 C compared with a value of 24 MeV-sq cm/mg obtained with the laser. In the case of the second type of 64K SRAM, the IBM640lCRH no upsets were observed at 125 C with the highest LET ions used at BNL. In contrast, the pulsed dye laser tests indicated a value of 90 MeV-sq cm/mg at room temperature for the SEU-hardened IBM SRAM. No latchups or multiple SEU's were observed on any of the SRAM's even under worst case conditions. The results of this study suggest that the laser can be used as an inexpensive laboratory SEU prescreen tool in certain cases.

Kim, Q.↗

Tropospheric HO determination by FAGE

In the measurement of tropospheric HO we have employed three low-pressure laser-excited fluorescence (LEF) experimental systems. These instruments operate by expanding the ambient air flow via a nozzle, followed by transit down a flowtube through a detection region traversed by the excitation laser beam. This sampling method we named FAGE (fluorescence assay with gas expansion). The instruments employed a hydrocarbon reagent, added below the nozzle, to remove HO for background measurement. In the second and third instruments, air sampling via parallel nozzles and tubes, with reagent addition alternating between two channels, permitted continuous signal measurement with simultaneous measurement of background. The first two instruments (FAGE1 and FAGE2) used 282 nm HO excitation by frequency-doubled tunable dye lasers, pumped by pulsed Nd:YAG lasers at 10-30 Hz repetition rate. The third instrument (FAGE3) uses 308 nm excitation in which the dye laser is pumped by a copper vapor laser, pulsed at 5600 Hz.

Hard, Thomas M.↗

Laser optogalvanic wavelength calibration with a commercial hollow cathode iron - neon discharge lamp

351 optogalvanic transitions have been observed in the 337 - 598 nm wavelength region using an iron - neon hollow cathode discharge lamp and a pulsed tunable dye laser. 223 of these have been identified as transitions associated with neon energy levels. These optogalvanic transitions have allowed, in conjunction with interference fringes recorded concomitantly with an etalon, the calibration of the dye laser wavelength with 0.3/cm accuracy.

Zhu, Xinming↗

Study of natural convection and interface shape in directional solidification of succinonitrile

Flow visualization experiments in a Bridgman furnace at zero growth velocity have been performed. The experiments were intended to investigate if the photochromic dye activation method could be used in a crystal growth study. The results from this work have confirmed that with a carefully designed experimental setup, the photochromic-dye method permits qualitative and quantitative evaluation of the flow field near the interface in crystal growth experiments. For the horizontal orientation of a 6 mm x 6 mm ampoule and an axial temperature gradient of 26.5 C/cm, velocity profiles have been obtained accurately at various positions near the interface. The maximum velocity of 1.29 mm/sec was measured in the central vertical plane and the flow was symmetrical about that plane. A flow inversion point was also noted, above which the flow was towards the interface and below it, away from the interface. The results obtained are useful for validating 3-dimensional numerical models and establishing a link between the macroscopic processing conditions and the formation of crystalline defects.

Kawaji, M.↗

Integrated optical components in thin films of polymers

The results will be reported on the study of integrated optical components based on nonlinear optical polymeric films. Polymers poly(methyl methacrylate) (PMMA) and polyimide (PI) doped with organic laser dyes 4-dicyanomethylene-2-methyl-6-p dimethylaminostyryl-4H pyran (DCM) and 1, 3, 5, 7, 8 - pentamethyl-2,6 -diethyl-pyrromethene -BF2-complex (Pyrommethene 567, PM-567) were selected as materials for light guiding films. Additionally, UV polymerized polydiacetylene (PDA) on glass substrate was used as a waveguide material. Optical waveguides were fabricated using spin coating of preoxidized silicon wafers (1.5 micrometer silicon oxide layer) with organic dye/polymer solution followed by soft baking. the modes in slab waveguides were studied using prism coupling techniques. Measured values of mode coupling angles in multimode waveguides were used to calculate film thickness and refractive index for different polarizations. Refractive index anisotropy was found in PDA waveguide. The optimal conditions of spin coating for single mode waveguide fabrication were estimated. Propagation losses were measured by collecting the light scattered from the trace of a propagating mode either by scanning photo detector or by CCD camera. Different types of light coupling techniques were used including end-dire coupling, prism and grating coupling. Mechanical printing technique was developed for coupling grating fabrication resulting in gratings with 4% diffraction efficiency. The gratings demonstrated good stability with diffraction efficiency relaxation rate 2.4 dB/hour at a temperature approximately 15-20 C below glass transition point. Dye doped waveguides were transversally pumped with frequency doubled Nd:YAG Q-switched laser producing intensive light emission with apparent 6 kW/sq cm pump threshold and spectrum narrowing near 617 nm peak in the case of DCM doped waveguide. PM-567 doped waveguide pumped with CW Ar(+) laser (514 nm wavelength) far below threshold (0.1 W/sq.cm pump power) demonstrated emission spectrum narrowing near 616 nm peak with 18% power conversion slope efficiency. In this case emission spectrum modification was caused by the enhanced light absorption along the direction of propagating waveguide modes. Changing length, thickness, and other morphlogical waveguide parameters one can modify emission spectrum in predictable direction. The results show that polymeric waveguides, especially based on high temperature polymers such as Pl, can be used to produce a varietiy of active and passive silicon compatible integrated optical components for aerospace applications.

Sarkisov, Sergey↗

Simultaneous Luminescence Pressure and Temperature Mapping System

A simultaneous luminescence pressure and temperature mapping system is developed including improved dye application techniques for surface temperature and pressure measurements from 5 torr to 1000 torr with possible upgrade to from 0.5 torr to several atmospheres with improved camera resolution. Adsorbed perylene dye on slip-cast silica is pressure (oxygen) sensitive and reusable to relatively high temperatures (approximately 150 C). Adsorbed luminescence has an approximately linear color shift with temperature, which can be used for independent temperature mapping and brightness pressure calibration with temperature.

Buck, Gregory M.↗

Water Tunnel Flow Visualization Study Through Poststall of 12 Novel Planform Shapes

To determine the flow field characteristics of 12 planform geometries, a flow visualization investigation was conducted in the Langley 16- by 24-Inch Water Tunnel. Concepts studied included flat plate representations of diamond wings, twin bodies, double wings, cutout wing configurations, and serrated forebodies. The off-surface flow patterns were identified by injecting colored dyes from the model surface into the free-stream flow. These dyes generally were injected so that the localized vortical flow patterns were visualized. Photographs were obtained for angles of attack ranging from 10' to 50', and all investigations were conducted at a test section speed of 0.25 ft per sec. Results from the investigation indicate that the formation of strong vortices on highly swept forebodies can improve poststall lift characteristics; however, the asymmetric bursting of these vortices could produce substantial control problems. A wing cutout was found to significantly alter the position of the forebody vortex on the wing by shifting the vortex inboard. Serrated forebodies were found to effectively generate multiple vortices over the configuration. Vortices from 65' swept forebody serrations tended to roll together, while vortices from 40' swept serrations were more effective in generating additional lift caused by their more independent nature.

Gatlin, Gregory M.↗

Concentration Measurements in a Cold Flow Model Annular Combustor Using Laser Induced Fluorescence

A nonintrusive concentration measurement method is developed for determining the concentration distribution in a complex flow field. The measurement method consists of marking a liquid flow with a water soluble fluorescent dye. The dye is excited by a two dimensional sheet of laser light. The fluorescent intensity is shown to be proportional to the relative concentration level. The fluorescent field is recorded on a video cassette recorder through a video camera. The recorded images are analyzed with image processing hardware and software to obtain intensity levels. Mean and root mean square (rms) values are calculated from these intensity levels. The method is tested on a single round turbulent jet because previous concentration measurements have been made on this configuration by other investigators. The previous results were used to comparison to qualify the current method. These comparisons showed that this method provides satisfactory results. 'Me concentration measurement system was used to measure the concentrations in the complex flow field of a model gas turbine annular combustor. The model annular combustor consists of opposing primary jets and an annular jet which discharges perpendicular to the primary jets. The mixing between the different jet flows can be visualized from the calculated mean and rms profiles. Concentration field visualization images obtained from the processing provide further qualitative information about the flow field.

Morgan, Douglas C.↗

CD4(+)/CD8(+) T-lymphocyte Ratio: Effects of Rehydration before Exercise in Dehydrated Men

Effects of fluid ingestion on CD4+/CD8+ T-lymphocyte cell ratios were measured in four dehydrated men (ages 30-46 yr) before and after 70 min of supine submaximal (71 % VO(sub 2max) lower extremity cycle exercise. Just before exercise, Evans blue dye was injected for measurement of plasma volume. The subjects then drank one of six fluid formulations (12 ml/kg) in 3-4 min. All six mean post-hydration (pre-exercise) CD4+/CD8+ ratios (Becton-Dickinson Fluorescence Activated Cell Sorter and FACScan Consort-30 software program were below the normal range of 1.2-1.5; mean (+/- SE) and range were 0.77 +/- 0.12 and 0.39-1.15, respectively. The post-exercise ratios increased: mean = 1.36 =/- 0.15 (P less than 0.05) and range = 0.98-1.98. Regression of mean CD4+/CD8+ ratios on mean plasma osmolality resulted in pre- and post-exercise correlation coefficients of -0.76 (P less than 0.10) and -0.92 (P less than 0.01), respectively. The decreased pre-exercise ratios (after drinking) were probably not caused by the Evans blue dye but appeared to be associated more with the stress (osmotic) of dehydration. The increased post-exercise ratios to normal levels accompanied the rehydration and were not due to the varied electrolyte and osmotic concentrations of the ingested fluids or to the varied vascular volume shifts during exercise. Thus, the level of subject hydration and plasma osmotality may be factors involved in the mechanism of immune system modulation induced by exercise.

Greenleaf, John E.↗