Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

ICARUS: new voyage to sterile neutrino search in the Short Baseline Program

The ICARUS collaboration operated the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratories studying neutrino oscillations with the CNGS neutrino beam from CERN, and searching for atmospheric neutrino interactions. ICARUS performed a sensitive search for LSND-like anomalous νe appearance in the CNGS beam, which contributed to the constraints on the allowed parameters to a narrow region around $Δm^2=1 e\text{V}^2$, where all the experimental results can be coherently accommodated at 90% C.L. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS has started operations and is presently in its commissioning phase with the aim of collecting its first neutrino events from the Booster Neutrino Beam and the NuMI off-axis beam. The main goal of the first year of ICARUS data taking will then be the definitive verification of the recent claim by NEUTRINO-4 short baseline reactor experiment both in the $ν_μ$ channel with the BNB and in the $ν_e$ with NuMI. After the first year of operations, ICARUS will commence its search for evidence of a sterile neutrino jointly with the SBND near detector, within the Short Baseline Neutrino (SBN) program. The ICARUS exposure to the NuMI beam will also give the possibility for other physics studies such as light dark matter searches and neutrino-Argon cross section measurements. The proposed contribution addresses ICARUS achievements, its status and plans for the new run at Fermilab and the ongoing developments of the analysis tools needed to fulfill its physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Heavy Stable Charged Particles in $pp$ collisions at $\sqrt{s}=7$ TeV

The result of a search at the LHC for heavy stable charged particles produced in pp collisions at sqrt(s) = 7 TeV is described. The data sample was collected with the CMS detector and corresponds to an integrated luminosity of 3.1 inverse picobarns. Momentum and ionization-energy-loss measurements in the inner tracker detector are used to identify tracks compatible with heavy slow-moving particles. Additionally, tracks passing muon identification requirements are also analyzed for the same signature. In each case, no candidate passes the selection, with an expected background of less than 0.1 events. A lower limit at the 95% confidence level on the mass of a stable gluino is set at 398 GeV/c^2, using a conventional model of nuclear interactions that allows charged hadrons containing this particle to reach the muon detectors. A lower limit of 311 GeV/c^2 is also set for a stable gluino in a conservative scenario of complete charge suppression, where any hadron containing this particle becomes neutral before reaching the muon detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of temperature-dependent dark current transport mechanism for GaAs-based blocked-impurity-band (BIB) detectors

Temperature-dependent dark current transport mechanism has been analyzed for GaAs-based blocked-impurity-band detectors. Device structure, processing steps and physical models are described in detail. In this work, the analysis of dark current transport mechanism has been greatly simplified by electron drift current related discussion based on the assumption that the diffusion current and the generation–recombination current as two dominating components of dark current in the absorbing layer can be equivalent to the electron drift current in the blocking layer. After confirming this assumption, our discussion focuses on why dark current is a monotonically increasing function of operation temperature for a fixed anode bias. Our results reveal that from dark current suppression point of view, low donor doping level and low operation temperature are preferred.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

19 F(α,n) thick target yield from 3.5 to 10.0 MeV

Using a target of PbF 2 , the thick-target yield from the 19 F(α,n) reaction was measured from E α =3.5–10 MeV. From these results, we infer the thick-target neutron yields from targets of F 2 and UF 6 over this same alpha-particle energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of space radiation-induced double strand breaks as a track in cell nucleus

To identify DNA damage induced by space radiations such as the high linear energy transfer (LET) particles, phospho-H2AX ({gamma}H2AX) foci formation was analyzed in human cells frozen in an International Space Station freezer for 133 days. After recovering the frozen sample to the earth, the cells were cultured for 30 min, and then fixed. Here we show a track of {gamma}H2AX positive foci in them by immuno-cytochemical methods. It is suggested that space radiations, especially high LET particles, induced DSBs as a track. From the formation of the tracks in nuclei, exposure dose rate was calculated to be 0.7 mSv per day as relatively high-energy space radiations of Fe-ions (500 MeV/u, 200 keV/{mu}m). From the physical dosimetry with CR-39 plastic nuclear track detectors and thermo-luminescent dosimeters, dose rate was 0.5 mSv per day. These values the exposed dose rate were similar between biological and physical dosimetries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization using pathwise algorithmic derivatives of electromagnetic shower simulations

Among the well-known methods to approximate derivatives of expectancies computed by Monte-Carlo simulations, averages of pathwise derivatives are often the easiest one to apply. Computing them via algorithmic differentiation typically does not require major manual analysis and rewriting of the code, even for very complex programs like simulations of particle-detector interactions in high-energy physics. However, the pathwise derivative estimator can be biased if there are discontinuities in the program, which may diminish its value for applications. This work integrates algorithmic differentiation into the electromagnetic shower simulation code HepEmShow based on G4HepEm, allowing us to study how well pathwise derivatives approximate derivatives of energy depositions in a sampling calorimeter with respect to parameters of the beam and geometry. We found that when multiple scattering is disabled in the simulation, means of pathwise derivatives converge quickly to their expected values, and these are close to the actual derivatives of the energy deposition. Additionally, we demonstrate the applicability of this novel gradient estimator for stochastic gradient-based optimization in a model example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subcellular Spatial Correlation of Particle Traversal and Biological Response in Clinical Ion Beams

Purpose: To report on the spatial correlation of physical track information (fluorescent nuclear track detectors, FNTDs) and cellular DNA damage response by using a novel hybrid detector (Cell-Fit-HD). Methods and Materials: The FNTDs were coated with a monolayer of human non-small cell lung carcinoma (A549) cells and irradiated with carbon ions (270.55 MeV u{sup −1}, rising flank of the Bragg peak). Phosphorylated histone variant H2AX accumulating at the irradiation-induced double-strand break site was labeled (RIF). The position and direction of ion tracks in the FNTD were registered with the location of the RIF sequence as an ion track surrogate in the cell layer. Results: All RIF sequences could be related to their corresponding ion tracks, with mean deviations of 1.09 μm and −1.72 μm in position and of 2.38° in slope. The mean perpendicular between ion track and RIF sequence was 1.58 μm. The mean spacing of neighboring RIFs exhibited a regular rather than random spacing. Conclusions: Cell-Fit-HD allows for unambiguous spatial correlation studies of cell damage with respect to the intracellular ion traversal under therapeutic beam conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of the first 150 mm diameter Cryogenic silicon ionization detectors with contact-free electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. Still larger individual detectors are being investigated to scale up the sensitive mass of future experiments. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. The results show promise for the use of such technologies in solid state cryogenic detectors.

150 mm↗

New Ultrafast Scintillators with Core Valence Luminescence: Cs 2 MgCl 4 and Cs 3 MgCl 5

Future experiments in high energy physics and medical imaging require radiation detectors having properties which are not presently available. The main limitations arise from lack of suitable scintillation crystals. This dilemma prompts the need for research leading to the discovery of new fast and bright scintillator materials that combine unique properties to fulfil modern experiment requirements without compromises. In this work, single crystals of Cs 2 MgCl 4 and Cs 3 MgCl 5 up to 12 mm in diameter are grown via the vertical Bridgman method. Scintillation properties are reported for the first time, and core valence luminescence is observed for both compounds. X-ray excited radioluminescence emission of Cs 2 MgCl 4 is centered at 295 nm, with a scintillation decay time of 2.25 ± 0.05 ns and relatively high core-valence light yield of 2,200 ± 110 ph/MeV. Cs 3 MgCl 5 has two main emission peaks centered at 242 nm and 302 nm, decay time of 1.46 ± 0.05 ns, and light yield of 1,340 ± 70 ph/MeV. The better coincidence time resolution (CTR) is obtained with Cs 2 MgCl 4 , which is measured to be 129 ± 4 ps FWHM. Density functional theory (DFT) calculations are also performed and provide supporting evidence that the observed scintillation originates from core valence luminescence. Furthermore, the combination of speed and brightness of these new scintillators could be useful for fast timing applications in which moderately dense materials are required.

36 MATERIALS SCIENCE↗

A detector 2 km away from the J-PARC neutrino source

We propose to build a detector at a site 2 km away from the neutrino production point of the T2K experiment. At this distance, measured neutrino spectrum is almost the same as unoscillated spectrum would be at Super-K 295 km away. We describe a plan to measure this spectrum with a 1 kilo ton water Cherenkov detector which has been optimized to match Super-K resolution as well as the muon range detector and the fine grained detector. The 2KM detector will allow to match the best constraint on the prediction of the unoscillated neutrino rate at the Super-K far detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivities of Future Long Baseline Experiments in the U.S

Sensitivities to neutrino oscillation parameters for possible very long baseline neutrino oscillation experiments are discussed. The reach for observing a non-zero mixing angle {theta}{sub 13}, establishing CP violation and determining the mass hierarchy are compared between various experimental options. Different possibilities for neutrino beams are briefly described, as well as the assumptions about the performance of a large water Cherenkov and liquid Argon detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Dark Matter Results from the CDMS 5-Tower Run and the path towards {sigma} = 10{sup -46} cm{sup 2} Wimp sensitivity

This paper will report on the recently released results from the Cryogenic Dark Matter Search (CDMS II) experiment. Data from 30 cryogenic particle detectors operated at the Soudan Underground Laboratory between October 2006 and July 2007 was collected. The results from from a blind analysis of 15 Ge detectors corresponding to total exposure of 121.3 kg-d (averaged over the recoil energy range 10-100 keV, and weighted for a weakly interacting massive particle (WIMP) mass of 60 GeV/c{sup 2}) are presented here. With zero observed events an upper limit on WIMP-nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} is obtained from this data set alone. The limit improves to 4.6x10{sup -44} cm{sup 2} when combined with previous CDMS data. The paper will also describe current efforts at designing and building larger mass detectors ({approx}few kg/detector) which will form the basis of a future 1-Ton cryogenic Ge detector experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Latest Results from DVCS at HERMES

The HERMES experiment at DESY, Hamburg, collected a rich data set for the analysis of Deeply Virtual Compton Scattering (DVCS) utilizing the HERA polarized electron or positron beams with an energy of 27.6 GeV and longitudinally and transversely polarized or unpolarized gas targets (H, D or heavier nuclei). The azimuthal asymmetries measured in the exclusive DVCS process allow the access to the imaginary and/or real part of certain combinations of Generalized Parton Distributions. Before the end of 2005 the recoiling target protons from the DVCS reaction were not detected and exclusivity was ensured indirectly using the missing-mass method. A Recoil Detector was installed in winter 2005-2006 to improve the exclusivity of such reactions at the event level by direct measurement of recoil protons. Latest results on combined analyses of beam-spin and beam-charge asymmetries and of beam-charge and transverse-target spin asymmetries are presented together with first results from the HERMES Recoil Detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Longitudinal Double Spin Asymmetries in Heavy Flavor Production in Polarized p+p Collisions at {radical}(s) = 200 GeV

One of the main goals of the RHIC spin program is to determine the contribution of gluons to the proton spin. At RHIC energies, heavy quark (charm and beauty) production is expected to be dominated by gluon-gluon interactions, so a measurement of the double longitudinal spin asymmetry A{sub LL} in heavy quark production in polarized p+p collisions directly probes the polarized gluon distribution inside the proton. We present the latest results on an A{sub LL} measurement for J/{psi} and open charm production measured by the PHENIX detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Restoring The Azimuthal Symmetry Of Charged Particle Lateral Density In The Range Of KASCADE-Grande

KASCADE-Grande, an extension of the former KASCADE experiment, is a multi-component Extensive Air Shower (EAS) experiment located in Karlsruhe Institute of Technology (Campus North), Germany. An important observable for analyzing the EAS is the lateral density of charged particles in the intrinsic shower plane. This observable is deduced from the basic information provided by the Grande scintillators - the energy deposit - first in the observation plane, by using a Lateral Energy Correction Function (LECF), then in the intrinsic shower plane, by applying an adequate mapping procedure. In both steps azimuthal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SuperB project

This paper presents a very short review of the SuperB project which aims to construct a new generation flavour factory with a designed luminosity of at least 10{sup 36} cm{sup -2} s{sup -1}. The main issues related to the physics programme, together with the description of the conceptual design of the accelerator and detector are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗