At least 1,477 records · Page 82

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Chapter 7: Learning Stable Local Volt/Var Controllers in Distribution Grids

This chapter describes a framework to synthesize provably stable local Volt/Var controllers for distributed energy resources (DERs) in power distribution grids (DGs). The goal is to control the reactive power injections of DERs to improve the system performance as quantified by a generic optimal reactive power flow (ORPF) problem. To achieve this, we jointly design for each DER the control function, which prescribes the reactive power update rule, and the equilibrium function, which approximates the ORPF solutions from local measurements of voltages and powers. We provide conditions on the equilibrium functions and the control parameters ensuring the stability of the closed-loop system. In particular, we discuss the trade-offs between each set of conditions accounting for practical considerations, like fully exploiting the DERs' generation capabilities and reducing the optimality gap. These conditions are then translated into learning constraints on the neural networks' parameters that are enforced in the training phase. We validate our framework with numerical simulations on the IEEE 37-bus network and through a comparison with an optimized version of standard piece wise linear control rules.

closed-loop asymptotic stability↗

Modeling of thermal storage systems in MILP distributed energy resource models

Thermal energy storage (TES) and distributed generation technologies, such as combined heat and power (CHP) or photovoltaics (PV), can be used to reduce energy costs and decrease CO 2 emissions from buildings by shifting energy consumption to times with less emissions and/or lower energy prices. To determine the feasibility of investing in TES in combination with other distributed energy resources (DER), mixed integer linear programming (MILP) can be used. Such a MILP model is the well-established Distributed Energy Resources Customer Adoption Model (DER-CAM); however, it currently uses only a simplified TES model to guarantee linearity and short run-times. Loss calculations are based only on the energy contained in the storage. This paper presents a new DER-CAM TES model that allows improved tracking of losses based on ambient and storage temperatures, and compares results with the previous version. A multi-layer TES model is introduced that retains linearity and avoids creating an endogenous optimization problem. The improved model increases the accuracy of the estimated storage losses and enables use of heat pumps for low temperature storage charging. Ultimately,results indicate that the previous model overestimates the attractiveness of TES investments for cases without possibility to invest in heat pumps and underestimates it for some locations when heat pumps are allowed. Despite a variation in optimal technology selection between the two models, the objective function value stays quite stable, illustrating the complexity of optimal DER sizing problems in buildings and microgrids.

25 ENERGY STORAGE↗

Incorporate day-ahead robustness and real-time incentives for electricity market design

In this paper, we propose a two-stage electricity market framework to explore the participation of distributed energy resources (DERs) in a day-ahead (DA) market and a real-time (RT) market. The objective is to determine the optimal bidding strategies of the aggregated DERs in the DA market and generate online incentive signals for DER-owners to optimize the social-welfare taking into account network operational constraints. Distributionally robust optimization is used to explicitly incorporate data-based statistical information of renewable forecasts into the supply/demand decisions in the DA market. We evaluate the conservativeness of bidding strategies distinguished by different risk aversion settings. In the RT market, a bi-level time-varying optimization problem is proposed to design the online incentive signals to tradeoff the RT imbalance penalty for distribution system operators (DSOs) and the costs of individual DER-owners. This enables tracking their optimal dispatch to provide fast balancing services, in the presence of time-varying network states while satisfying the voltage regulation requirement. Simulation results on both DA wholesale market and RT balancing market demonstrate the necessity of this two-stage design, and its robustness to uncertainties, the performance of convergence, the tracking ability and the feasibility of the resulting network operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗

First-principles study of the stability and migration of Kr, I and Xe in ZrO2

The stability and migration of Kr, I and Xe in bulk ZrO2 and on the ZrO2 (1 1 1) surface have been studied by standard density functional theory (DFT) and the DFT-D2 method that corrects for the van der Waals interaction. Both methods show that Kr and Xe prefer to incorporate in the bulk phase rather than adsorb on the surface, and Xe is very mobile in the bulk state. For Kr and Xe adsorption on the surface, van der Waals interaction dominates, causing the weak interaction between the adsorbate and substrate. Iodine is found to have comparable stability in both phases and forms I O bonds with strong covalency. It exhibits higher mobility on the surface than in the bulk ZrO2, and diffusion from bulk-like state to surface state is an exothermic process. The fission product behavior in ZrO2 is shown to be a complicated synergetic effect of fission product atomic size, electron negativity, occupation site and phase structure of the host.

Xiao, Haiyan↗

Self-similarity and scaling transitions during rupture of thin free films of Newtonian fluids

Rupture of thin liquid films is crucial in many industrial applications and nature such as foam stability in oil-gas separation units, coating flows, polymer processing, and tear films in the eye. In some of these situations, a liquid film may have two free surfaces (referred to here as a free film or a sheet) as opposed to a film deposited on a solid substrate that has one free surface. The rupture of such a free film or a sheet of a Newtonian fluid is analyzed under the competing influences of inertia, viscous stress, van der Waals pressure, and capillary pressure by solving a system of spatially one-dimensional evolution equations for film thickness and lateral velocity. The dynamics close to the space-time singularity where the film ruptures is asymptotically self-similar and, therefore, the problem is also analyzed by reducing the transient partial differential evolution equations to a corresponding set of ordinary differential equations in similarity space. Here, for sheets with negligible inertia, it is shown that the dominant balance of forces involves solely viscous and van der Waals forces, with capillary force remaining negligible throughout the thinning process in a viscous regime. On the other hand, for a sheet of an inviscid fluid for which the effect of viscosity is negligible, it is shown that the dominant balance of forces is between inertial, capillary, and van der Waals forces as the film evolves towards rupture in an inertial regime. Real fluids, however, have finite viscosity. Hence, for real fluids, it is further shown that the viscous and the inertial regimes are only transitory and can only describe the initial thinning dynamics of highly viscous and slightly viscous sheets, respectively. Moreover, regardless of the fluid’s viscosity, it is shown that for sheets that initially thin in either of these two regimes, their dynamics transition to a late stage or final inertial-viscous regime in which inertial, viscous, and van der Waals forces balance each other while capillary force remains negligible, in accordance with the results of Vaynblat, Lister, and Witelski.

36 MATERIALS SCIENCE↗

Resilience of the Electric Grid Through Trustable IoT-Coordinated Assets

The electricity grid has evolved from a physical system to a cyberphysical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) including renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. We propose a framework in this paper for achieving grid resilience through suitably coordinated assets including a network of Internet of Things devices. A local electricity market is proposed to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. With this SA, we show that a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. Multiple demonstrations are carried out using a high-fidelity cosimulation platform, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

distributed energy resources↗

Network-Aware and Welfare-Maximizing Dynamic Pricing for Energy Sharing

The proliferation of behind-the-meter (BTM) distributed energy resources (DER) within the electrical distribution network presents significant supply and demand flexibilities, but also introduces operational challenges such as voltage spikes and reverse power flows. In response, this paper proposes a network-aware dynamic pricing framework tailored for energy-sharing coalitions that aggregate small, but ubiquitous, BTM DER downstream of a distribution system operator's (DSO) revenue meter that adopts a generic net energy metering (NEM) tariff. By formulating a Stackelberg game between the energy-sharing market leader and its prosumers, we show that the dynamic pricing policy induces the prosumers toward a network-safe operation and decentrally maximizes the energysharing social welfare. The dynamic pricing mechanism involves a combination of a locational ex-ante dynamic price and an ex-post allocation, both of which are functions of the energy sharing's BTM DER. The ex-post allocation is proportionate to the price differential between the DSO NEM price and the energy-sharing locational price. Simulation results using real DER data and the IEEE 13-bus test systems illustrate the dynamic nature of network-aware pricing at each bus, and its impact on voltage.

aggregates↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

Quantifying Transmission Fault Voltage Influence and its Potential Impact on Distributed Energy Resources

With increasing shares of distributed energy resources (DERs) on the electric grid, the power system is transitioning from having fewer large generators with relatively simple dynamics to many small generators with aggregate responses to system disturbances that are difficult to predict. In particular, voltage fluctuations might cause large losses of generation via DER operation/interconnection compliance. To understand orchestral DER dynamics, a first step is to determine the influence of a disturbance on the overall bulk power system. This work introduces metrics that allow for the classification and comparison of a variety of system faults with respect to their influences on voltage profiles. These metrics are applied to standardized fault simulations on the Western Interconnection Paths with a full-scale Positive Sequence Load Flow model. The results are presented with a highlight on Path 61, which has the potential for DER generation reduction exceeding the current credible contingency of a double Palo Verde loss.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Value Investigation of Medium-Voltage Back-to-Back Converters

This paper presents the results of an investigation into the value that medium voltage back-to-back (MVB2B) converters can be realized through two potential applications: voltage regulation via the provision of reactive power supply or absorption, and distributed energy resource (DER) hosting capacity improvement via the controlled transfer of real power within the distribution system. Two groups of distribution systems have been prepared for the value investigation: the IEEE 123-bus system for the voltage regulation study and two utility-provided, realistic distribution systems for the DER hosting capacity improvement study. The results demonstrate that the MVB2B converter can realize significant value for the grid through these two applications. In particular, with the MVB2B converter transferring power between two feeders, DER-based power can be routed to nearby loads instead of feed through the distribution substation. Additionally, the size of energy storage elements used to enable higher levels of DERs can be significantly reduced.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Allocating Reserves in Active Distribution Systems for Tertiary Frequency Regulation

This paper proposes a cooperative game theory-based approach for reserve optimization to enable distributed energy resources (DERs) participate in tertiary frequency regulation. Tertiary frequency regulation schemes ensure that reserve requirements of primary and secondary frequency regulation are fulfilled with a minimum cost. While the available reserve from a single distribution system may not suffice tertiary frequency regulation, stacked reserve from several distribution systems can enable them participate in tertiary frequency regulation at scale. In this paper, a two-stage strategy is proposed to effectively and precisely allocate spinning reserve requirement from each DER in distribution systems. In the first stage, two types of characteristic functions are computed: worthiness index (WI) and power loss reduction (PLR). In the second stage, the equivalent Shapley values are computed based on the characteristic functions, which are used to determine distribution factors for reserve allocation among DERs. The effectiveness of the proposed method for allocating reserves among DERs is demonstrated through several case studies on modified versions of the IEEE 13-node and 33-node distribution systems.

Gautam, Mukesh↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗