Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curve fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Light-curve Analysis of Ordinary Type IIP Supernovae Based on Neutrino-driven Explosion Simulations in Three Dimensions

Type II-plateau supernovae (SNe IIP) are the most numerous subclass of core-collapse SNe originating from massive stars. In the framework of the neutrino-driven explosion mechanism, we study the properties of the SN outburst for a red supergiant progenitor model and compare the corresponding light curves with observations of the ordinary Type IIP SN 1999em. Three-dimensional (3D) simulations of (parametrically triggered) neutrino-driven explosions are performed with the (explicit, finite-volume, Eulerian, multifluid hydrodynamics) code Prometheus, using a presupernova model of a 15 M {sub ⊙} star as initial data. On approaching homologous expansion, the hydrodynamic and composition variables of the 3D models are mapped to a spherically symmetric configuration, and the simulations are continued with the (implicit, Lagrangian, radiation hydrodynamics) code Crab to follow the evolution of the blast wave during the SN outburst. Our 3D neutrino-driven explosion model with an explosion energy of about 0.5×10{sup 51} erg produces {sup 56}Ni in rough agreement with the amount deduced from fitting the radioactively powered light-curve tail of SN 1999em. The considered presupernova model, 3D explosion simulations, and light-curve calculations can explain the basic observational features of SN 1999em, except for those connected to the presupernova structure of the outer stellar layers. Our 3D simulations show that the distribution of {sup 56}Ni-rich matter in velocity space is asymmetric with a strong dipole component that is consistent with the observations of SN 1999em. The monotonic decline in luminosity from the plateau to the radioactive tail in ordinary SNe IIP is a manifestation of the intense turbulent mixing at the He/H composition interface.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-RESOLUTION ROTATION CURVES AND GALAXY MASS MODELS FROM THINGS

We present rotation curves of 19 galaxies from The H I Nearby Galaxy Survey (THINGS). The high spatial and velocity resolution of THINGS make these the highest quality H I rotation curves available to date for a large sample of nearby galaxies, spanning a wide range of H I masses and luminosities. The high quality of the data allows us to derive the geometric and dynamical parameters using H I data alone. We do not find any declining rotation curves unambiguously associated with a cut-off in the mass distribution out to the last measured point. The rotation curves are combined with 3.6 {mu}m data from the Spitzer Infrared Nearby Galaxies Survey to construct mass models. Our best-fit dynamical disk masses, derived from the rotation curves, are in good agreement with photometric disk masses derived from the 3.6 {mu}m images in combination with stellar population synthesis arguments and two different assumptions for the stellar initial mass function (IMF). We test the cold dark matter (CDM) motivated cusp model, and the observationally motivated central density core model and find that (independent of IMF) for massive, disk-dominated galaxies, all halo models fit apparently equally well; for low-mass galaxies, however, a core-dominated halo is clearly preferred over a cusp-like halo. The empirically derived densities of the dark matter halos of the late-type galaxies in our sample are half of what is predicted by CDM simulations, again independent of the assumed IMF.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FIRST SYSTEMATIC STUDY OF TYPE Ibc SUPERNOVA MULTI-BAND LIGHT CURVES

We present detailed optical photometry for 25 Type Ibc supernovae (SNe Ibc) within d Almost-Equal-To 150 Mpc obtained with the robotic Palomar 60 inch telescope in 2004-2007. This study represents the first uniform, systematic, and statistical sample of multi-band SNe Ibc light curves available to date. We correct the light curves for host galaxy extinction using a new technique based on the photometric color evolution, namely, we show that the (V - R) color of extinction-corrected SNe Ibc at {Delta}t Almost-Equal-To 10 days after V-band maximum is tightly distributed, ((V - R){sub V10}) = 0.26 {+-} 0.06 mag. Using this technique, we find that SNe Ibc typically suffer from significant host galaxy extinction, (E(B - V)) Almost-Equal-To 0.4 mag. A comparison of the extinction-corrected light curves for helium-rich (Type Ib) and helium-poor (Type Ic) SNe reveals that they are statistically indistinguishable, both in luminosity and decline rate. We report peak absolute magnitudes of (M{sub R}) = -17.9 {+-} 0.9 mag and (M{sub R}) = -18.3 {+-} 0.6 mag for SNe Ib and Ic, respectively. Focusing on the broad-lined (BL) SNe Ic, we find that they are more luminous than the normal SNe Ibc sample, (M{sub R}) = -19.0 {+-} 1.1 mag, with a probability of only 1.6% that they are drawn from the same population of explosions. By comparing the peak absolute magnitudes of SNe Ic-BL with those inferred for local engine-driven explosions (GRB-SN 1998bw, XRF-SN 2006aj, and SN 2009bb) we find a 25% probability that relativistic SNe are drawn from the overall SNe Ic-BL population. Finally, we fit analytic models to the light curves to derive typical {sup 56}Ni masses of M{sub Ni} Almost-Equal-To 0.2 and 0.5 M{sub Sun} for SNe Ibc and SNe Ic-BL, respectively. With reasonable assumptions for the photospheric velocities, we further extract kinetic energy and ejecta mass values of M{sub ej} Almost-Equal-To 2 M{sub Sun} and E{sub K} Almost-Equal-To 10{sup 51} erg for SNe Ibc, while for SNe Ic-BL we find higher values, M{sub ej} Almost-Equal-To 5 M{sub Sun} and E{sub K} Almost-Equal-To 10{sup 52} erg. We discuss the implications for the progenitors of SNe Ibc and their relation to those of engine-driven explosions.

79 ASTRONOMY AND ASTROPHYSICS↗

Lick Observatory Supernova Search follow-up program: photometry data release of 93 Type Ia supernovae

Here, we present BVRI and unfiltered light curves of 93 Type Ia supernovae (SNe Ia) from the Lick Observatory Supernova Search (LOSS) follow-up program conducted between 2005 and 2018. Our sample consists of 78 spectroscopically normal SNe Ia, with the remainder divided between distinct subclasses (3 SN 1991bg-like, 3 SN 1991T-like, 4 SNe Iax, 2 peculiar, and 3 super-Chandrasekhar events), and has a median redshift of 0.0192. The SNe in our sample have a median coverage of 16 photometric epochs at a cadence of 5.4 d, and the median first observed epoch is ~4.6 d before maximum B-band light. We describe how the SNe in our sample are discovered, observed, and processed, and we compare the results from our newly developed automated photometry pipeline to those from the previous processing pipeline used by LOSS. After investigating potential biases, we derive a final systematic uncertainty of 0.03 mag in BVRI for our data set. We perform an analysis of our light curves with particular focus on using template fitting to measure the parameters that are useful in standardizing SNe Ia as distance indicators. All of the data are available to the community, and we encourage future studies to incorporate our light curves in their analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

The visual brightness behavior of P/Halley during 1981-1986

The behavior of the total visual coma brightness of P/Halley during 1981 to 1986 is discussed. Observations used include 75 published V magnitudes obtained with large telescopes (usually with CCDs) prior to July 1985 and 650 total magnitudes estimated visually with smaller telescopes during the period July 1985 to Aug 1986. The macroscopic light curve is discussed, and least-square fits to the traditional power-law formula are provided. Further work is needed to apply physically-meaningful formulae, based on models describing dust and gas-production rates, to the observed light curve of P/Halley. Brightness variations on smaller timescales (hours, days) are reviewed.

Green, Daniel W. E.↗

Precise Time Delays from Strongly Gravitationally Lensed Type Ia Supernovae with Chromatically Microlensed Images

Time delays between the multiple images of strongly gravitationally lensed Type Ia supernovae (glSNe Ia) have the potential to deliver precise cosmological constraints, but the effects of microlensing on time delay extraction have not been studied in detail. Here we quantify the effect of microlensing on the glSN Ia yield of the Large Synoptic Survey Telescope (LSST) and the effect of microlensing on the precision and accuracy of time delays that can be extracted from LSST glSNe Ia. Microlensing has a negligible effect on the LSST glSN Ia yield, but it can be increased by a factor of ~2 over previous predictions to 930 systems using a novel photometric identification technique based on spectral template fitting. Crucially, the microlensing of glSNe Ia is achromatic until three rest-frame weeks after the explosion, making the early-time color curves microlensing-insensitive time delay indicators. By fitting simulated flux and color observations of microlensed glSNe Ia with their underlying, unlensed spectral templates, we forecast the distribution of absolute time delay error due to microlensing for LSST, which is unbiased at the sub-percent level and peaked at 1% for color curve observations in the achromatic phase, while for light-curve observations it is comparable to state-of-the-art mass modeling uncertainties (4%). About 70% of LSST glSN Ia images should be discovered during the achromatic phase, indicating that microlensing time delay uncertainties can be minimized if prompt multicolor follow-up observations are obtained. Lastly, accounting for microlensing, the 1-2 day time delay on the recently discovered glSN Ia iPTF16geu can be measured to 40% precision, limiting its cosmological utility.

79 ASTRONOMY AND ASTROPHYSICS↗

QUARK-NOVAE OCCURRING IN MASSIVE BINARIES: A UNIVERSAL ENERGY SOURCE IN SUPERLUMINOUS SUPERNOVAE WITH DOUBLE-PEAKED LIGHT CURVES

A quark-nova (QN; the sudden transition from a neutron star into a quark star), which occurs in the second common envelope (CE) phase of a massive binary, gives excellent fits to superluminous, hydrogen-poor, supernovae (SLSNe) with double-peaked light curves, including DES13S2cmm, SN 2006oz, and LSQ14bdq (http://www.quarknova.ca/LCGallery.html). In our model, the H envelope of the less massive companion is ejected during the first CE phase, while the QN occurs deep inside the second, He-rich, CE phase after the CE has expanded in size to a radius of a few tens to a few thousands of solar radii; this yields the first peak in our model. The ensuing merging of the quark star with the CO core leads to black hole formation and accretion, explaining the second long-lasting peak. We study a sample of eight SLSNe Ic with double-humped light curves. Our model provides good fits to all of these, with a universal explosive energy of 2 × 10{sup 52} erg (which is the kinetic energy of the QN ejecta) for the first hump. The late-time emissions seen in iPTF13ehe and LSQ14bdq are fit with a shock interaction between the outgoing He-rich (i.e., second) CE and the previously ejected H-rich (i.e., first) CE.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibrating Constant Elasticity of Substitution Technologies to Bottom-up Cost Estimates

We propose a method for calibrating an industry-level technology to engineering (bottom-up) estimates with a particular focus on abatement opportunities. As a demonstration, substitution elasticities across inputs are adjusted in the nested cost function for the electricity sector to best fit a target marginal abatement cost (MAC) curve derived from engineering assessments of available technologies. Elasticities are optimized over an entire relevant range of the MAC, whereas current techniques use local point estimates under little or no abatement. In the context of fitting to a given MAC we evaluate alternative nesting structures and find that, while complexity in nesting improves the fit, even relatively simple nesting structures can reasonably approximate the target MAC. In our example, focused on the electricity sector, we find standard elasticities adopted in top-down models moderately overstate abatement costs relative to the engineering targets. In our preferred specification the most important adjustment is to escalate the substitution elasticity between energy and value-added inputs. This is consistent with an argument that the current set of point estimates fail to properly account for new capital-based technologies. These conclusions, however, are sensitive to our assumption about output-intensity abatement and consumer price responsiveness, both of which are not delineated in engineering estimates.

abatement cost↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis Of Residence Time Distribution Of Fluid Flow By Axial Dispersion Model

Radioactive tracer {sup 82}Br in the form of KBr-82 with activity {+-} 1 mCi has been injected into steel pipeline to qualify the extent dispersion of water flowing inside it. Internal diameter of the pipe is 3 in. The water source was originated from water tank through which the water flow gravitically into the pipeline. Two collimated sodium iodide detectors were used in this experiment each of which was placed on the top of the pipeline at the distance of 8 and 11 m from injection point respectively. Residence time distribution (RTD) curves obtained from injection of tracer are elaborated numerically to find information of the fluid flow properties. The transit time of tracer calculated from the mean residence time (MRT) of each RTD curves is 14.9 s, therefore the flow velocity of the water is 0.2 m/s. The dispersion number, D/uL, for each RTD curve estimated by using axial dispersion model are 0.055 and 0.06 respectively. These calculations are performed after fitting the simulated axial dispersion model on the experiment curves. These results indicated that the extent of dispersion of water flowing in the pipeline is in the category of intermediate.

07 ISOTOPE AND RADIATION SOURCES↗

Echo mapping of active galactic nuclei broad-line regions: Fundamental algorithms

We formulate and test a series of algorithms for echo mapping the emission-line regions near active galactic nuclei from measurements of correlated variability in their line and continuum light curves. The linear regularization method (LRM) employs a direct inversion of evenly spaced light-curve data, with a regularization parameter that can be used to control the trade-off between noise and resolution. Matrix formulas express the formal solution as well as its variance and covariance in terms of uncertainties in the measurements. Unlike the maximum-entropy method (MEM), LRM applies to kernels with both positive and negative values, but the results are somewhat limited by ringing effects. A positivity constraint proves effective in controlling the ringing. MEM combines regularization and positivity in a natural way, but similar results are also found using positivity constraints with nonentropic regularization functions. Direct inversions of unevenly sampled light curves require interpolating the noisy data. In this case better results are found by solving for both the continuum light curve and kernel function in a simultaneous fit to the data. Our conclusion is that while echo mapping currently gives ambiguous results, the algorithms are not the limiting factor. Progress depends on efforts to increase the accuracy and completeness of sampling of the observed light curves.

Vio, Roberto↗

Direct Analysis of JV-Curves Applied to an Outdoor-Degrading CdTe Module (Presentation)

We present the application of a phenomenological four parameter equation to fit and analyze regularly measured current density-voltage JV curves of a CdTe module during 2.5 years of outdoor operation. The parameters are physically meaningful, i.e. the short circuit current density Jsc, open circuit voltage Voc and differential resistances Rsc, and Roc. For the chosen module, the fill factor FF degradation overweighs the degradation of Jsc and Voc. Interestingly, with outdoor exposure, not only the conductance at short circuit, Gsc, increases but also the Gsc(Jsc)-dependence. This is well explained with an increase in voltage dependent charge carrier collection in CdTe.

14 SOLAR ENERGY↗

A Hubble space telescope search for a sub-Earth-sized exoplanet in the GJ 436 system

The detection of small planets orbiting nearby stars is an important step toward the identification of Earth twins. In previous work using the Spitzer Space Telescope, we found evidence to support at least one sub-Earth-sized exoplanet orbiting the nearby mid-M dwarf star GJ 436. As a follow up, here we used the Hubble Space Telescope (HST) to investigate the existence of one of these candidate planets, UCF-1.01, by searching for two transit signals as it passed in front of its host star. Interpretation of the data hinges critically on correctly modeling and removing the Wide Field Camera 3 (WFC3) instrument systematics from the light curves. Building on previous HST work, we demonstrate that WFC3 analyses need to explore the use of a quadratic function to fit a visit-long time-dependent systematic. This is important for establishing absolute transit and eclipse depths in the white light curves of all transiting systems. The work presented here exemplifies this point by putatively detecting the primary transit of UCF-1.01 with the use of a linear trend. However, using a quadratic trend, we achieve a better fit to the white light curves and a reduced transit depth that is inconsistent with previous Spitzer measurements. Furthermore, quadratic trends with or without a transit model component produce comparable fits to the available data. Using extant WFC3 transit light curves for GJ 436b, we further validate the quadratic model component by achieving photon-limited model fit residuals and consistent transit depths over multiple epochs. We conclude that, when we fit for a quadratic trend, our new data contradict the prediction of a sub-Earth-sized planet orbiting GJ 436 with the size, period, and ephemeris posited from the Spitzer data by a margin of 3.1σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Strain-dependent partial slip on rock fractures under seismic-frequency torsion: Seismic-Frequency Fracture Partial Slip

Measurements of nonlinear modulus and attenuation of fractures provide the opportunity to probe their mechanical state. We have adapted a low-frequency torsional apparatus to explore the seismic signature of fractures under low normal stress, simulating low effective stress environments such as shallow or high pore pressure reservoirs. We report strain-dependent modulus and attenuation for fractured samples of Duperow dolomite (a carbon sequestration target reservoir in Montana), Blue Canyon Dome rhyolite (a geothermal analog reservoir in New Mexico), and Montello granite (a deep basement disposal analog from Wisconsin). We use a simple single effective asperity partial slip model to fit our measured stress-strain curves, and solve for the friction coefficient, contact radius, and full slip condition. These observations have the potential to develop into new field techniques for measuring differences in frictional properties during reservoir engineering manipulations and estimate the stress conditions where reservoir fractures and faults begin to fully slip.

58 GEOSCIENCES↗

Comparative study of optical and structural properties of electrospun 1-dimensional CaYAl{sub 3}O{sub 7}:Eu{sup 3+} nanofibers and bulk phosphor

We report the optical and structural studies of Eu{sup 3+}-doped 1-dimensional CaYAl{sub 3}O{sub 7} nano-fiber phosphor. CaYAl{sub 3}O{sub 7}:Eu{sup 3+} phosphors were synthesized by electrospinning technique and the pristine nano-fibers were annealed at 900 °C to form well crystallized uniform fibers. Under ultraviolet excitation, the CaYAl{sub 3}O{sub 7}:Eu{sup 3+} exhibited red emission, due to transitions in the 4f states of Eu{sup 3+}. In order to explore the difference between the quantum efficiency of nano-fiber and bulk CaYAl{sub 3}O{sub 7}:Eu{sup 3+} phosphor, detailed structural and optical analyses were carried out. The structural analysis of the CaYAl{sub 3}O{sub 7}:Eu{sup 3+} nano-fibers indicates that the structural environment surrounding the dopant Eu{sup 3+} ion was more unstable in nano-fiber when compared to a bulk sample. Decay curves for both the samples when fitted with double exponential decay model indicate that the nano-fiber has shorter decay time, arising from the larger contribution from the non-radiative decay, due to defect levels introduced in the host lattice. - Highlights: • Synthesis of red nano-phosphor through electrospinning • Luminescence properties of bulk and nano-phosphors are compared. • Inferior emission intensity of the nano-phosphor is analyzed using MEM. • Charge cloud around nano-phosphor was found to be oblique.

36 MATERIALS SCIENCE↗

Compression behavior of microcrystalline cellulose spheres: Single particle compression and confined bulk compression across regimes

Particle characteristics can drastically influence the process-structure-property-performance aspects of granular materials in compression. In this study, we aim to computationally simulate the mechanical processes of stress redistribution in compacts including the kinematics of particle rearrangement during densification and particle deformation leading to fragmentation. Confined compression experiments are conducted with three sets of commercial microcrystalline cellulose particles nearly spherical in shape with different mean particle size. Experimentally measured compression curves from tall powder columns are fitted with the Kenkre et al. (J. of American Chemical Society, Vol. 79, No. 12) model. This model provides a basis to derive several common two-parameter literature models and as a framework to incorporate statistical representations of critical particle behaviors. We focus on the low-stress compression data and the model comparisons typically not discussed in the literature. Furthermore, additional single particle compressions report fracture strength with particle size for comparison to the apparent particle strength extracted from bulk compression data.

42 ENGINEERING↗

Determination of rain age via {gamma} rays from accreted radon progeny

The relative {gamma} ray activities from {sup 214}Pb and {sup 214}Bi condensed from precipitation are used to determine its 'age', the average time the accreted activity has been removed from secular equilibrium. A verifiable assumption that radon progeny on/in the surface/volume of droplets mostly remains in secular equilibrium until they begin their descent, enables estimates of their transit times to ground of typically a few tens of minutes. This agrees well with the time expected for the activity on the surface of droplets to reach the ground from heights of a few kilometers. The half lives of {gamma} activities from {sup 214}Bi and {sup 214}Pb, 19.7 and 26.9 min, respectively, are on the same scale as transit time to ground and close enough to each other to measure ratios of activities from secular equilibrium (1.00) to transient equilibrium (3.88) within a few hundreds of minutes. The ratio of {gamma} count rates is independent of knowledge of either initial activity or any systematic errors and thus limited only by the uncertainty from counting statistics, which from condensates of 5-30 l of rain viewed with 2{pi} solid angle by a 50% efficient, high-resolution Ge detector is only a few percent. These ratios fit extremely well to known theoretical curves, which cannot only be used to date rain but can also be extrapolated backward to determine radon progeny activities in rain prior to its descent, knowledge of which may facilitate further studies using radon progeny as tracers.

54 ENVIRONMENTAL SCIENCES↗

Characterization of unconventional electron fields for the treatment of mycosis fungoides using the total skin irradiation technique

Mycosis fungoides is a cutaneous lymphoma that accounts for 2–3% of all lymphomas. Several clinical studies have demonstrated the effectiveness of TSEBT (Total Skin Electron Beam Therapy) in patients with mycosis fungoides. It is important to develop this technique and make it available to a larger number of patients in Mexico. Because large fields for electron TSEBT are required in order to cover the entire body of the patient, beam characterization at conventional treatment distances is not sufficient and a calibration distance of 500cm or higher is required. Materials and methods: Calibration of radiochromic Gafchromic® EBT2 film (RCF) for electrons was performed in a solid water phantom (Scanditronix Wellhöfer) at a depth of 1.4cm and a Source Axis Distance (SAD) of 100cm. A polynomial fit was applied to the calibration curve, in order to obtain the equation relating dose response with optical density. The spatial distribution is obtained in terms of percentage of the dose, placing 3×3cm samples of RCF on the acrylic screen, which is placed in front of the patient in order to obtain maximum absorbed dose on the skin, covering an area of 200×100cm{sup 2}. The Percentage Depth Dose (PDD) curve was obtained placing RCF samples at depths of 0, 1, 1.2, 1.4, 1.5, 2, 3, 4, 5, 6, 7, 8 and 9cm in the solid water phantom, irradiated with an ELEKTA SINERGY Linear Accelerator electron beam, with an energy of 6 MeV, at a Source Skin Distance (SSD) of 500cm, with 1000MU = 100Gy, with a cone of 40×40cm and gantry angle of 90°. The RCFs were scanned on a flatbed scanner (EPSON EXPRESSION 10000 XL) and the images were processed with the ImageJ program using a region of interest (ROI) of 1×1cm{sup 2}. Results: The relative spatial dose distribution and the percentage depth dose for a SSD of 500±0.5cm, over an area of 200×100cm{sup 2} was obtained, resulting to an effective maximum dose depth (Z{sub ref}) for electrons of 1.4±0.05cm. Using the same experimental data, horizontal and vertical beam profiles were also graphed, showing a horizontal symmetry of ±035%, horizontal flatness of ±3.62%, vertical symmetry of ±2.1% and vertical flatness of ±14.2%. Conclusions: The electron beam was characterized and the data obtained were useful to determine the spatial dose distribution to a SSD of 500±0.5cm, in an area of 200×100cm{sup 2}. Dose profiles were obtained both horizontally and vertically, thus allowing to assess electron beam symmetry and flatness. PDD analysis up to a depth of 9±0.05cm, has made possible to establish the depth of electron penetration, assuring an only skin irradiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗