Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Migration to a fully-integrated control room - 349

The nuclear industry is faced with a pressing need to reduce operating costs in order to remain competitive with other forms of electric generation. While current industry initiatives are focused on incremental gains by streamlining work processes and reducing worker burdens, very few, if any, involve significant reductions in the base workload of a nuclear plant. Migration to a fully-integrated control room affords just such an opportunity. This report describes an NPP digital instrumentation and control (I and C) system design, along with its corresponding human systems interface (HSI) design, which achieves high plant availability, while selectively applying digital equipment redundancy and integrating traditional I and C system partitions, to minimize the digital equipment needed, and thereby minimize initial installation costs and ongoing operations and maintenance (O and M) costs. An additional key component of digital equipment minimization is optimization of the digital interface to conventional plant sensors and controlled plant devices (e.g., pumps, valves), which requires no disturbance to plant cables and results in eliminating thousands of electro-mechanical relay control components. The design is rooted in the highly integrated digital technology applied to the most recent advanced light water reactors under United States (U.S.) Nuclear Regulatory Commission (NRC) design certification review and approval. While this design employs technology from new plants, that technology has been adapted to the modernization of current operating NPPs. Hence, the highly integrated digital I and C and HSI design is referred to as the compact control room digital modernization (CDM). Along with minimal digital equipment, the corresponding HSI design employs compact operator workstations with visual display units (VDU) and soft controls for both the main control room (MCR) and remote shutdown room (RSR), to immediately improve human performance and ultimately facilitate operating staff reduction. Some advanced light water reactors have demonstrated this staff reduction through full scope simulator testing of normal and abnormal plant conditions, with U.S. licensed operating crews from currently-operating U.S. plants. Digital equipment minimization, compact operator workstations, and optimized plant component interfaces that require no disturbance to field cables, also facilitate implementation of the CDM over multiple phases, most of which can be conducted during normal refueling shutdown windows. This phased implementation method includes a novel transition of the I and C, MCR and RSR with an operations centered focus. This paper presents the CDM design, along with qualitative cost/benefit comparisons to currently operating plants with conventional analog I and C and HSI technology; this generation of I and C/HSI is referred to as a conventional control room (CCR). A CCR also includes NPPs that have been upgraded with digital systems, but retain the current partitions between plant I and C systems (i.e., no I and C integration) and retain the current plant system to control board configuration of current NPP control rooms. Even though these comparisons are qualitative, a compelling case is presented for the CDM. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A practical approach to determine minimal quantum gate durations using amplitude-bounded quantum controls

Here, we present an iterative scheme to estimate the minimal duration in which a quantum gate can be realized while satisfying hardware constraints on the control pulse amplitudes. The scheme performs a sequence of unconstrained numerical optimal control cycles that each minimize the gate fidelity for a given gate duration alongside an additional penalty term for the control pulse amplitudes. After each cycle, the gate duration is adjusted based on the inverse of the resulting maximum control pulse amplitudes by re-scaling the dynamics to a new duration where control pulses satisfy the amplitude constraints. Those scaled controls then serve as an initial guess for the next unconstrained optimal control cycle, using the adjusted gate duration. We provide multiple numerical examples that each demonstrate fast convergence of the scheme toward a gate duration that is close to the quantum speed limit, given the control pulse amplitude bound. The proposed technique is agnostic to the underlying system and control Hamiltonian models, as well as the target unitary gate operation, making the time-scaling iteration an easy to implement and practically useful scheme for reducing the durations of quantum gate operations.

97 MATHEMATICS AND COMPUTING↗

Nuclear microreactor transient and load-following control with deep reinforcement learning

The economic feasibility of nuclear microreactors will depend on minimizing operating costs through advancements in autonomous control, especially when these microreactors are operating alongside other types of energy systems (e.g., renewable energy). This study explores the application of deep reinforcement learning (RL) for real-time drum control in microreactors, exploring performance in regard to load-following scenarios. By leveraging a point kinetics model with thermal and xenon feedback, we first establish a baseline using a single-output RL agent, then compare it against a traditional proportional–integral–derivative (PID) controller. This study demonstrates that RL controllers, including both single- and multi-agent RL (MARL) frameworks, can achieve similar or even superior load-following performance as traditional PID control across a range of load-following scenarios. In short transients, the RL agent was able to reduce the tracking error rate in comparison to PID by one half to one third. Over extended 300-minute load-following scenarios in which xenon feedback becomes a dominant factor, PID maintained better accuracy, but RL still remained within a 1% error margin despite being trained only on short-duration scenarios. This highlights RL’s strong ability to generalize and extrapolate to longer, more complex transients, affording substantial reductions in training costs and reduced overfitting. Furthermore, when control was extended to multiple drums, MARL enabled independent drum control as well as maintained reactor symmetry constraints without sacrificing performance---an objective that standard single-agent RL could not learn. We also found that, as increasing levels of Gaussian noise were added to the power measurements, the RL controllers were able to maintain lower error rates than PID, and to do so with at least 10% and upwards of 150% less control effort. These findings illustrate RL's potential for autonomous nuclear reactor control, laying the groundwork for future integration into high-fidelity simulations and experimental validation efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-G-BRA-06: Application of Systems and Control Theory-Based Hazard Analysis to Radiotherapy

Purpose: The process of delivering radiation occurs in a complex socio-technical system heavily reliant on human operators. Furthermore, both humans and software are notoriously challenging to account for in traditional hazard analysis models. High reliability industries such as aviation have approached this problem through using hazard analysis techniques grounded in systems and control theory. The purpose of this work is to apply the Systems Theoretic Accident Model Processes (STAMP) hazard model to radiotherapy. In particular, the System-Theoretic Process Analysis (STPA) approach is used to perform a hazard analysis of a proposed on-line adaptive cranial radiosurgery procedure that omits the CT Simulation step and uses only CBCT for planning, localization, and treatment. Methods: The STPA procedure first requires the definition of high-level accidents and hazards leading to those accidents. From there, hierarchical control structures were created followed by the identification and description of control actions for each control structure. Utilizing these control structures, unsafe states of each control action were created. Scenarios contributing to unsafe control action states were then identified and translated into system requirements to constrain process behavior within safe boundaries. Results: Ten control structures were created for this new CBCT-only process which covered the areas of hospital and department management, treatment design and delivery, and vendor service. Twenty three control actions were identified that contributed to over 80 unsafe states of those control actions resulting in over 220 failure scenarios. Conclusion: The interaction of people, hardware, and software are highlighted through the STPA approach. STPA provides a hierarchical model for understanding the role of management decisions in impacting system safety so that a process design requirement can be traced back to the hazard and accident that it is intended to mitigate. Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Synthesis and simulation of a two-level magnetic control system for tokamak-reactor plasma

Synthesis and simulation of a hierarchical (two-level) magnetic system for controlling a tokamakreactor plasma throughout the entire divertor discharge stage, including the plasma current ramp-up phase, are carried out. The plasma vertical velocity is stabilized about zero by using a proportional controller in a scalar control loop. The gain of the controller-the coefficient that ensures the required stability margins-is found by using a second-order linear model constructed by solving the identification problem on the basis of numerical experiments carried out with the DINA plasmophysical computer code. The internal cascade (the lower level of the system) for tracking the scenario currents in the poloidal magnetic field coils is synthesized by using the complete dynamic channel decoupling method. The external cascade (the upper level of the system) for tracking the plasma current and shape is synthesized by using the method of pseudoseparation of the control channels and the multidimensional diagonal proportional-integral controller, with proportional, integrating, and double integrating units connected in parallel in each channel. In the hierarchical control system, the lower level (the internal cascade) is subordinated to the upper level (the external cascade). The external cascade acts on the internal one by the signals that set the required currents in the coils of the central solenoid and of the poloidal magnetic field in order to ensure the required plasma current and shape in accordance with the output signals from the plant, which are transmitted through the vector feedback channel. The lower level is aimed exclusively at tracking the reference inputs by tracking the currents in the control coils. An operating mode of the system under the conditions of current saturation in the control coils is proposed and implemented. Results are presented from numerical simulations of the two-level (cascade) control system for reference scenario no. 2 of the ITER database (www.iter.org) with the DINA nonlinear code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applied & Computational MathematicsChallenges for the Design and Control of Dynamic Energy Systems

The Energy Independence and Security Act of 2007 (EISA) was passed with the goal 'to move the United States toward greater energy independence and security.' Energy security and independence cannot be achieved unless the United States addresses the issue of energy consumption in the building sector and significantly reduces energy consumption in buildings. Commercial and residential buildings account for approximately 40% of the U.S. energy consumption and emit 50% of CO{sub 2} emissions in the U.S. which is more than twice the total energy consumption of the entire U.S. automobile and light truck fleet. A 50%-80% improvement in building energy efficiency in both new construction and in retrofitting existing buildings could significantly reduce U.S. energy consumption and mitigate climate change. Reaching these aggressive building efficiency goals will not happen without significant Federal investments in areas of computational and mathematical sciences. Applied and computational mathematics are required to enable the development of algorithms and tools to design, control and optimize energy efficient buildings. The challenge has been issued by the U.S. Secretary of Energy, Dr. Steven Chu (emphasis added): 'We need to do more transformational research at DOE including computer design tools for commercial and residential buildings that enable reductions in energy consumption of up to 80 percent with investments that will pay for themselves in less than 10 years.' On July 8-9, 2010 a team of technical experts from industry, government and academia were assembled in Arlington, Virginia to identify the challenges associated with developing and deploying newcomputational methodologies and tools thatwill address building energy efficiency. These experts concluded that investments in fundamental applied and computational mathematics will be required to build enabling technology that can be used to realize the target of 80% reductions in energy consumption. In addition the finding was that there are tools and technologies that can be assembled and deployed in the short term - the next 3-5 years - that can be used to significantly reduce the cost and time effective delivery of moderate energy savings in the U.S. building stock. Simulation tools, which are a core strength of current DOE computational research programs, provide only a part of the answer by providing a basis for simulation enabled design. New investments will be required within a broad dynamics and control research agenda which must focus on dynamics, control, optimization and simulation of multi-scale energy systems during design and operation. U.S. investments in high performance and high productivity computing (HP2C) should be leveraged and coupled with advances in dynamics and control to impact both the existing building stock through retrofits and also new construction. The essential R&D areas requiring investment are: (1) Characterizing the Dynamics of Multi-scale Energy Systems; (2) Control and Optimization Methodologies of Multi-scale Energy Systems Under Uncertainty; and (3) Multiscale Modeling and Simulation Enabled Design and Operation. The concept of using design and control specific computational tools is a new idea for the building industry. The potential payoffs in terms of accelerated design cycle times, performance optimization and optimal supervisory control to obtain and maintain energy savings are huge. Recent advances in computational power, computer science, and mathematical algorithms offer the foundations to address the control problems presented by the complex dynamics of whole building systems. The key areas for focus and associated metrics with targets for establishing competitiveness in energy efficient building design and operation are: (1) Scalability - Current methodology and tools can provide design guidance for very low energy buildings in weeks to months; what is needed is hours to days. A 50X improvement is needed. (2) Installation and commissioning - Current methodology and tools can target a three month window for commissioning of building subsystems; what is needed is one week. A 10X improvement is needed. (3) Quality - Current design tools can achieve 30% accuracy; what is needed to make design decisions is 5% with quantification of uncertainty. A 5X improvement is needed. These challenges cannot be overcome by raw computational power alone and require the development of new algorithms. Here algorithms mean much more than simulating the building physics but need to be inclusive of a much better understanding of the building and the control systems associated with the building and to capture the entire set of dynamics. The algorithmsmust represent computationally new mathematical approaches to modeling, simulation, optimization and control of large multi-scale dynamic systems and bringing these elements to bear on industry in simulation enabled design approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

Variational stability of optimal control problems involving subdifferential operators

This paper is concerned with the problem of minimizing an integral functional with control-nonconvex integrand over the class of solutions of a control system in a Hilbert space subject to a control constraint given by a phase-dependent multivalued map with closed nonconvex values. The integrand, the subdifferential operators, the perturbation term, the initial conditions and the control constraint all depend on a parameter. Along with this problem, the paper considers the problem of minimizing an integral functional with control-convexified integrand over the class of solutions of the original system, but now subject to a convexified control constraint. By a solution of a control system we mean a 'trajectory-control' pair. For each value of the parameter, the convexified problem is shown to have a solution, which is the limit of a minimizing sequence of the original problem, and the minimal value of the functional with the convexified integrand is a continuous function of the parameter. This property is commonly referred to as the variational stability of a minimization problem. An example of a control parabolic system with hysteresis and diffusion effects is considered. Bibliography: 24 titles.

97 MATHEMATICS AND COMPUTING↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Novel Design for Switchable Grid-Following and Grid-Forming Control

This paper presents the design of a novel grid- forming (GFM) control structure adapted from a typical grid- following (GFL) control structure with minimal edits, thereby enabling a switchable control structure for voltage sourced converters (VSCs) to operate in either GFL or GFM mode by simply switching a flag manually. The VSC is shown to be able to operate in the GFL control mode synchronizing to the main grid through a phase-locked-loop (PLL) and operate as a GFM controller with power-based synchronization for both grid-connected and islanded conditions. To guarantee smooth operation, the control schemes and the mode switching logic have been carefully designed and examined via a series of experiments. Here, the experiment results show that the switchable control structure can fulfill the desired control and operation functions and enable smooth transition between control modes.

14 SOLAR ENERGY↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recommended Practice for Patch Management of Control Systems

A key component in protecting a nation’s critical infrastructure and key resources is the security of control systems. The term industrial control system refers to supervisory control and data acquisition, process control, distributed control, and any other systems that control, monitor, and manage the nation’s critical infrastructure. Critical Infrastructure and Key Resources (CIKR) consists of electric power generators, transmission systems, transportation systems, dam and water systems, communication systems, chemical and petroleum systems, and other critical systems that cannot tolerate sudden interruptions in service. Simply stated, a control system gathers information and then performs a function based on its established parameters and the information it receives. The patch management of industrial control systems software used in CIKR is inconsistent at best and nonexistent at worst. Patches are important to resolve security vulnerabilities and functional issues. This report recommends patch management practices for consideration and deployment by industrial control systems owners.

42 ENGINEERING↗

Control blade degradation test under temperature gradient in steam atmosphere

The core of a boiling water reactor (BWR) consists of an array of fuel assemblies with cross-shaped control blades located between these assemblies. The typical control blade consists of a control blade sheath made of 316L-type S.S., a center pole made of 316L-type S.S., and control rods. In order to understand the degradation process of the control blade channel, control blade degradation tests were performed under various atmospheres with a temperature increase condition and in the presence of a temperature gradient. A test device was built. Four carbon heaters are set on both sides at the upper and the middle parts of the test device. The bottom ceramic part of the test device is cooled by water. Heating in the upper region and cooling at the bottom of the test piece give rise to the temperature gradient in the test piece. Temperatures of the test piece are measured by five W-Re type thermocouples placed close to the test piece. Steam carried by the argon gas is supplied from the bottom of the device and flows to the top inside a square carbon muffle in which the test piece is set. Three windows for visual observations are installed, with one located above the furnace and the others located at the back of the furnace. In the steam atmosphere with a steam flow rate of 0.0125 g/s/rod, the control blade, channel box, and fuel rods were degraded, especially at the upper part of the test piece. This result was similar to that observed in the argon atmosphere test. However, the observed degradation was rather different at a higher steam flow rate of 0.0417 g/s/rod. At the upper part of the test piece, only the control blade was degraded preferentially and did not react with the channel box wall. In contrast, the eutectic reaction of the stainless steel/boron carbide melt and zircaloy occurred at the lower part by coexisting with the relocated melt from the top part. These observations suggested the existence of a threshold condition for the control rod degradation between 0.0125 and 0.0417 g/s/rod which is significantly affected by the thickness of the oxide layer on zircaloy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Direct Adaptive Control of Utility-Scale Wind Turbine for Speed Regulation

The accurate modeling of wind turbines is an extremely challenging problem due to the tremendous complexity of the machines and the turbulent and unpredictable conditions in which they operate. Adaptive control techniques are well suited to nonlinear applications, such as wind turbines, which are difficult to accurately model and which have effects from poorly known operating environments. In this paper, we extended the direct model reference adaptive control (DMRAC) approach to track a reference point and to reject persistent disturbances. This approach was then used to design an adaptive collective pitch controller for a high-fidelity simulation of a variable-speed horizontal axis wind turbine. The objective of the adaptive pitch controller was to regulate generator speed in Region 3 and to reject step disturbances. The control objective was accomplished by collectively pitching the turbine blades. The turbine simulation models the controls advanced research turbine (CART) of the National Renewable Energy Laboratory in Golden, Colorado. The CART is a utility-scale wind turbine that has a well-developed and extensively verified simulator. This novel application of adaptive control was compared in simulations with a classical proportional integrator (PI) collective pitch controller. In the simulations, the adaptive pitch controller showed improved speed regulation in Region 3 when compared with the PI pitch controller.

17 WIND ENERGY↗