Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

Science Data Report for the Optical Properties Monitor (OPM) Experiment

This science data report describes the Optical Properties Monitor (OPM) experiment and the data gathered during its 9-mo exposure on the Mir space station. Three independent optical instruments made up OPM: an integrating sphere spectral reflectometer, vacuum ultraviolet spectrometer, and a total integrated scatter instrument. Selected materials were exposed to the low-Earth orbit, and their performance monitored in situ by the OPM instruments. Coinvestigators from four NASA Centers, five International Space Station contractors, one university, two Department of Defense organizations, and the Russian space company, Energia, contributed samples to this experiment. These materials included a number of thermal control coatings, optical materials, polymeric films, nanocomposites, and other state-of-the-art materials. Degradation of some materials, including aluminum conversion coatings and Beta cloth, was greater than expected. The OPM experiment was launched aboard the Space Shuttle on mission STS-81 in January 1997 and transferred to the Mir space station. An extravehicular activity (EVA) was performed in April 1997 to attach the OPM experiment to the outside of the Mir/Shuttle Docking Module for space environment exposure. OPM was retrieved during an EVA in January 1998 and was returned to Earth on board the Space Shuttle on mission STS-89.

Wilkes, D. R.↗

Initial Results from Vision-based Control of the Marsokhod Rover

A geologist characterizing a field site typically wanders from one interesting geologic feature to another. Performing geology remotely with a mobile robot, we have observed the same behavior: geologists see a visually-interesting feature and wish to approach it for closer inspection. To date, navigating a mobile robot to a visually-interesting feature has been accomplished by driving to a location close to the feature. This introduces two problems: assigning a location to the feature and navigating the rover to that location. In practice, solutions to both of these problems are susceptable to positional error. Fundamentally, we can see where we want the robot to go, but it is difficult to precisely quantify where either the target or the robot are located. The development of vision-based control of robot manipulators suggests an alternative approach for mobile robot explorers. We have developed a vision-based control system that enables the Marsokhod rover to drive to within sampling distance of visually-designated rock or natural feature. We will describe this system and our initial results using it during a field experiment in the Painted Desert of Arizona.

Wettergreen, David↗

Issues and Concerns in Robotic Drilling

Exploration of the Martian subsurface will be essential in the search for life and water, given the desiccated and highly oxidized conditions on the surface. Discovery of these, at least in non-fossil form, is unlikely without drilling or other physical access to the subsurface. Hence subsurface access will be critical for both future in-situ science and Mars sample return. Drilling applications present many new challenges for diagnosis and control technology. Traditionally, diagnosis has concentrated on determining the internal state of a system, and detecting failures of system components. In the case of drilling applications, an additional challenge is to diagnose the interactions between the drill and its environment. This is necessary because particular observations of the drilling operation may be consistent with a number of possible problems, including faults in the equipment, but also changes in the material being drilled (for example, from rock to ice). The diagnosis of a particular observation may also depend on knowledge of geological formations previously encountered during drilling, and different remedial actions may be required for each diagnosis. Current 2009 Mars mission scenarios call for no more than 33 sols to be spent drilling. Yet they also call for a baseline of two 2m-deep holes in each of three target areas, for a total of six drilling operations. Using current levels of automation, it is estimated that 15-16 sols would be required to drill each hole. As a result of this, either the drilling part of the mission plan will need to be severely downscoped to no more than two holes total, or on-board automation and robotics must be increased in order to reduce the number of sols required per hole by removing ground control from the drilling control loop. This lecture will discuss salient issues and concerns of robotic drilling automation compares with other applications, and implementation constraints.

Glass, Brian↗

Experiments with osteoblasts cultured under hypergravity conditions

To understand further the role of gravity in osteoblast attachment, osteoblasts were subjected to hypergravity conditions in vitro. Scanning electron microscopy of all confluent coverslips from FPA units show that the number of attached osteoblasts was similar among gravitational levels and growth durations (~90 cells/microscopic field). Specifically, confluent 1.0 G control cultures contained an average of 91 +/- 8 cells/field, 3.3 G samples had 88 +/- 8 cells/field, and 4.0 G cultures averaged 90 +/- 7 cells/field. The sparsely plated cultures assessed by immunohistochemistry also had similar numbers of cells at each time point (l.0 G was similar to 3.3 and 4.0 G), but cell number changed from one time point to the next as those cells proliferated. Immunohistochemistry of centrifuged samples showed an increase in number (up to 160% increase) and thickness (up to 49% increase) of actin fibers, a decrease in intensity of fibronectin fluorescence (18-23% decrease) and an increase in number of vinculin bulbs (202-374% increase in number of vinculin bulbs/area). While hypergravity exposure did not alter the number of attached osteoblasts, it did result in altered actin, fibronectin, and vinculin elements, changing some aspects of osteoblast- substrate adhesion.

NASA Program Fundamental Space Biology↗

Passive Optical Sample Assembly (POSA-2) Space Flight Experiment

NASA Lewis Research Center's Electro-Physics Branch is participating in the POSA-2 Space Flight Experiment to assess the effects of low Earth orbit and spacecraft environment contamination on power system materials and surfaces. This experiment package will be flown for 1 year in low Earth orbit and will be returned to Earth for subsequent evaluation of optical and thermal properties. Representative samples of solar array blanket materials, solar dynamic reflector materials, thermal control coatings, and sapphire are included in the experiment package.

Source record↗

Identification Of Cells With A Compact Microscope Imaging System With Intelligent Controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking mic?oscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

McDowell, Mark↗

Operation of a Cartesian Robotic System in a Compact Microscope with Intelligent Controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

McDowell, Mark↗

The NASA-Sponsored Study of Cataract in Astronauts (NASCA). Relationship of Exposure to Radiation in Space and the Risk of Cataract Incidence and Progression. Report 1: Recruitment and Methodology

The NASA Study of Cataract in Astronauts (NASCA) is a five-year, multi-centered, investigation of lens opacification in populations of U.S. astronauts, military pilots, and ground-based (nonaviator) comparison participants. For astronauts, the explanatory variable of most interest is radiation exposure during space flight, however to properly evaluate its effect, the secondary effects of age, nutrition, general health, solar ocular exposure, and other confounding variables encountered in non-space flight must also be considered. NASCA contains an initial baseline, cross-sectional objective assessment of the severity of cortical (C), nuclear (N), and posterior subcapsular (PSC) lens opacification, and annual follow-on assessments of severity and progression of these opacities in the population of astronauts and in participants sampled from populations of military pilots and ground-based exposure controls. From these data, NASCA will estimate the degree to which space radiation affects lens opacification for astronauts and how the overall risks of each cataract type for astronauts compared with those of the other exposure control groups after adjusting for differences in age and other explanatory variables.

Chylack, Leo T.↗

Tracking of Cells with a Compact Microscope Imaging System with Intelligent Controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously

McDowell, Mark↗

Spacecraft Guidance, Navigation, and Control Visualization Tool

G-View is a 3D visualization tool for supporting spacecraft guidance, navigation, and control (GN&C) simulations relevant to small-body exploration and sampling (see figure). The tool is developed in MATLAB using Virtual Reality Toolbox and provides users with the ability to visualize the behavior of their simulations, regardless of which programming language (or machine) is used to generate simulation results. The only requirement is that multi-body simulation data is generated and placed in the proper format before applying G-View.

Mandic, Milan↗

Toxicological Assessment of ISS Air Quality: April - May 2013

A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

Meyers, Valerie↗

Acquisition and Retaining Granular Samples via a Rotating Coring Bit

This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the frictional force must be greater than the weight of the sample. The bit can be designed with an internal sleeve to serve as a container for granular samples. This tube-shaped component can be extracted upon completion of the sampling, and the bottom can be capped by placing the bit onto a corklike component. Then, upon removal of the internal tube, the top section can be sealed. The novel features of this device are: center dot A mechanism of acquiring and retaining granular samples using a coring bit without a closed door. center dot An acquisition bit that has internal structure such as a waffle pattern for compartmentalizing or helical internal flute to propel the sample inside the bit and help in acquiring and retaining granular samples. center dot A bit with an internal spiral into which the various particles wedge. center dot A design that provides a method of testing frictional properties of the granular samples and potentially segregating particles based on size and density. A controlled acceleration or deceleration may be used to drop the least-frictional particles or to eventually shear the unconsolidated material near the bit center.

Bar-Cohen, Yoseph↗

Water Contents of the Mantle Beneath the Rio Grande Rift: FTIR Analysis of Kilbourne Hole Peridotite Xenoliths

Although nominally anhydrous mantle minerals contain only trace amounts of water, they are the main reservoir of water in the mantle. Added up at the scale of the Earth's mantle, these trace amounts of water represent oceans worth in mass]. Mantle xenoliths from Kilbourne Hole in southern New Mexico are ideal to study mantle water distribution in a rift tectonic setting as they come from a recently‐erupted maar in the middle of the Rio Grande Rift. Eleven lherzolites, one harzburgite, and one dunite are being analyzed for water contents by FTIR. The xenoliths will also be analyzed for major and trace element composition, Fe3+/Summation (Fe) ratios, and characterized petrologically. Olivines exhibit variable water contents with less water at the rims compared to the cores. This is probably due to H loss during decompression and xenolith transport by the host magma. Mantle water contents appear to have been primarily preserved in the core of the olivines, based on diffusion modeling of the typically plateau-shaped water content profiles across these grains. Water concentrations are in equilibrium between clino- and orthopyroxene, but olivine concentrations are typically not in equilibrium with those of either pyroxene. Lherzolites analyzed so far have water contents of 2‐12 ppm H2O in olivines, 125‐165 ppm H2O in orthopyroxenes, and 328‐447 ppm H2O in clinopyroxenes. These water contents are similar to, but with a narrower range, than those for the respective minerals in other continental peridotite xenoliths. The lherzolites have bulk-rock (BR) Al2O3 contents that range between 3.17 and 3.78 wt%, indicating similar degrees of partial melting, which could explain the narrow range of their pyroxene water contents. Primitive mantle normalized rare earth element (REE) profiles of the bulk lherzolites vary from light REE depleted to flat, with no significant differences between, nor relation to, their mineral water contents. Consequently, the metasomatic agents that enriched LREEs in these lherzolites were most likely water-poor. The harzburgite and the dunite have lower weight percent Al2O3 compared to the lherzolites (2.11% and 0.34% respectively) indicating higher degrees of melting. Their olivine water contents, however, are similar to those of the lherzolites. Moreover, no correlations are observed between pyroxene water contents and indices of melting or metasomatism between the lherzolite group, the harzburgite, and the dunite, although the latter has the lowest pyroxene water contents. More samples will be analyzed to determine if the water contents are controlled by melting, metasomatism, or a combination of the two in the Kilbourne Hole mantle.

Schaffer, Lillian A.↗

Lunar Processing Cabinet 2.0: Retrofitting Gloveboxes into the 21st Century

In 2014, the Apollo 16 Lunar Processing Glovebox (cabinet 38) in the Lunar Curation Laboratory at NASA JSC received an upgrade including new technology interfaces. A Jacobs - Technology Innovation Project provided the primary resources to retrofit this glovebox into the 21st century. NASA Astromaterials Acquisition & Curation Office continues the over 40 year heritage of preserving lunar materials for future scientific studies in state-of-the-art facilities. This enhancement has not only modernized the contamination controls, but provides new innovative tools for processing and characterizing lunar samples as well as supports real-time exchange of sample images and information with the scientific community throughout the world.

Calaway, M. J.↗

Advanced Curation Activities at NASA: Preparation for Upcoming Missions

The responsibility for curating NASA's astromaterials collections falls to the NASA Curation Office at Johnson Space Center. Under the governing document, NASA Policy Directive (NPD) 7100.10F and derivative requirements documents, JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions to include material returned in Mars Sample Return (MSR) efforts, OSIRIS-REx, NASA's subset of Hayabusa-2 samples, and any other sample return missions. The Directive defines Curation as activities including documentation, preservation, sample preparation, distribution, and tracking of samples for research, education, and public outreach. In this abstract we will describe Curation's research and development efforts to improve the care of existing collections and prepare for future NASA sample return missions. These efforts are collectively referred to as Advanced Curation, a term first coined in 2002.

Fries, M. D.↗

The Contaminant Footprint of Landed Spacecraft: Toward an Inventory and Modelling Framework

All spacecraft generate and carry contaminants, i.e., unwanted and potentially harmful material. When a spacecraft lands and operates in near-vacuum, as onto Earth’s Moon, it introduces contaminants into its environment that may compromise mission science objectives and engineering performance. Contamination of solar system bodies may irrevocably degrade targets of unique value to planetary scientists, for instance, as lunar landed spacecraft introduce propellant effluents into the otherwise pristine ice of the Moon’s permanently shadowed regions. NASA’s planetary protection discipline seeks to ensure that solar system bodies are not contaminated, for scientific purposes, by terrestrial material (i.e., forward contamination). This interest aligns with planetary science interest in mitigating the transport of terrestrial contaminants onto solar system bodies and in controlling types of contamination that could compromise the scientific value of samples or measurements. NASA, and other entities that practice planetary science, have compelling and multidisciplinary interests in the preservation of special regions and sampling sites of high scientific value – including lunar permanently shadowed regions (PSRs) – from inadvertent contamination by any spacecraft, and in understanding the contamination of such regions by all spacecraft. Organic molecular contamination here represents a primary threat. Organic molecules will be introduced to solar system bodies by nominal landed spacecraft and crew processes – including by the action of descent and ascent engines; natural materials outgassing; and crew environmental and life support system sources. Molecular contaminants can also travel in the free-molecular sense at global scale across near-vacuum bodies, including into regions where they may be permanently trapped. This presentation will address a high-level study to identify sources of contaminants – in particular, organic material – generated by landed spacecraft along with the transport vectors by which these contaminants can reach sites of scientific interest on bodies like the Moon. A vision for an integrated modeling framework for the organic contamination footprint of spacecraft missions, individually and collectively, will also be described and presented along with initial conclusions related to organic molecular transport.

Gas Dynamics↗

The diatom record from beneath the West Antarctic Ice Sheet and the global proxy perspective

Recent glaciological evaluation and modeling of the marine-based West Antarctic Ice Sheet (WAIS) support the possibility that the WAIS disintegrated during one or more Pleistocene interglacial period(s). The magnitude of sea level and oxygen isotope variation during certain late-Pleistocene interglacial periods is also consistent with the possibility of major retreat of the WAIS. Although oxygen isotopes from deep-sea sediments provide the best available proxy record for global ice volume (despite the ambiguities in the record), the source of ice volume changes must be hypothesized. Based on the intensity of interglacial isotopic shifts recorded in Southern Ocean marine sedimentary records, stage 11 (400,000 years ago) is the strongest candidate for WAIS collapse, but the records for stages 9, 7, and 5.5 are all consistent with the possibility of multiple late-Pleistocene collapses. Seismic reflection studies through the WAIS have revealed thick successions of strata with seismic characteristics comparable to upper Tertiary marine sediments. Small samples of glacial diamictons from beneath the ice sheet have been collected via hot-water drilled access holes. These sediments include mixed diatom assemblages of varying ages. Late-Miocene diatoms dominate many samples, probably reflecting marine deposition in West Antarctic basins prior to development of a dominantly glacial phase in West Antarctica. In addition to late-Miocene diatoms, samples from Upstream B (1988/89) contain rare post-Miocene diatoms, many of which imply deposition in the West Antarctic interior during one or more Pleistocene deglaciation periods. Age-diagnostic fossils in glacial sediments beneath ice sheets provide relatively coarse chronostratigraphic control, but they do contain direct evidence of regional deglaciation. Thus, sub-glacial till samples provide the evidence regarding the source of ice sheet variability seen in well-dated proxy records. Combined, these independent data sets can provide a more comprehensive and less speculative interpretation of the history of past glacial minima in currently glaciated polar regions.

Scherer, Reed P.↗