Vacuum vessel design with lofted toroidal surfaces for a QHS configuration

A vacuum vessel in between the hot plasma and the magnetic coils is crucial for a fusion reactor. In this study, a tool is presented to perform the initial design of such a vessel automatically. Starting from the last closed flux surface, an algorithm is developed which lofts this manifold out as much as possible. At the same time, the algorithm makes sure that no intersection with the coils takes place. In the presented work, this algorithm is applied to the HSX stellarator and it has been verified that the resulting vessel wall can be built from an engineering perspective. Using field line tracing, the strikepoints on the vessel wall indicate the initial locations for a divertor.

HSX↗

Comparative analysis of various CO 2 configurations in supermarket refrigeration systems

Our paper presents an analysis of various CO 2 transcritical and cascade/secondary loop refrigeration systems that are becoming popular in supermarket applications with the objective of optimizing the operating parameters of these systems. In addition, the performance of selected CO 2 -based refrigeration systems is compared to the baseline R404A multiplex direct expansion system using bin analyses in the eight climate zones of the United States. Moreover, for the refrigeration systems investigated, it was found that the Transcritical Booster System with Bypass Compressor (TBS-BC) had the lowest energy consumption for ambient temperatures (T amb ) less than 8 °C, and for higher ambient temperatures the R404A direct expansion system was found to have the lowest energy consumption. Finally, the TBS-BC performs equivalent to or better than the R404A direct expansion system in the northern two-thirds of the US. For the southern portion of the US, the R404A multiplex DX system performs better than CO 2 systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Permanent Planar Iodine-125 Implants: The Dosimetric Effect of Geometric Parameters for Idealized Source Configurations

Purpose: To provide dosimetric information about permanent planar {sup 125}I implants in a manner that is useful to the brachytherapist in the operative setting. Methods and Materials: Reference planar permanent implants were simulated for a variety of areas with sources placed uniformly on a 1-cm grid. Implants having variable source spacing and curvature were simulated and compared with the reference implants. Dosimetric measures were calculated at 0.5 and 1.0 cm from the implant plane. Results: A method for calculating dosimetric statistics for permanent implants ranging from 5 x 5 cm to 13 x 13 cm is presented. A formula to predict the reference source strength needed to achieve a desired dosimetric quantity is also presented. The effect of adjusting strand spacing to compensate for source activity is presented and is shown to be an effective means to adjust implants to use source strengths other than the reference strength. The effect of implant curvature compared with flat implants on dosimetric statistics is presented as a function of radius of curvature. Conclusions: The results presented in this work may be used to provide information about dose delivered from planar permanent implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Secondary Neutron Doses for Several Beam Configurations for Proton Therapy

Purpose: To compare possible neutron doses produced in scanning and scattering modes, with the latter assessed using a newly built passive-scattering proton beam line. Methods and Materials: A 40 x 30.5 x 30-cm water phantom was irradiated with 230-MeV proton beams using a gantry angle of 270{sup o}, a 10-cm-diameter snout, and a brass aperture with a diameter of 7 cm and a thickness of 6.5 cm. The secondary neutron doses during irradiation were measured at various points using CR-39 detectors, and these measurements were cross-checked using a neutron survey meter with a 22-cm range and a 5-cm spread-out Bragg peak. Results: The maximum doses due to secondary neutrons produced by a scattering beam-delivery system were on the order of 0.152 mSv/Gy and 1.17 mSv/Gy at 50 cm from the beam isocenter in the longitudinal (0{sup o}) and perpendicular (90{sup o}) directions, respectively. The neutron dose equivalent to the proton absorbed dose, measured from 10 cm to 100 cm from the isocenter, ranged from 0.071 mSv/Gy to 1.96 mSv/Gy in the direction of the beam line (i.e., {phi} = 0 deg.). The largest neutron dose, of 3.88 mSv/Gy, was observed at 135{sup o} and 25 cm from the isocenter. Conclusions: Although the secondary neutron doses in proton therapy were higher when a scattering mode rather than a scanning mode was used, they did not exceed the scattered photon dose in typical photon treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Neutron Dose Equivalent and its Dependence on Beam Configuration for a Passive Scattering Proton Delivery System

Purpose: To measure the neutron dose equivalent per therapeutic proton dose (H/D) in a passive scattering proton therapy system and study its dependence on the proton energy, aperture-to-isocenter distance, spread-out Bragg peak (SOBP) width, and field size. Methods and Materials: We performed four experiments of varying proton energies, aperture-to-isocenter distances, SOBP widths, and field sizes. Etched track detectors were used to measure the neutron dose equivalent at both an in-field (isocenter, beyond the protons' range) and out-of-field (30 cm lateral to the isocenter) location in air. Results: For a nonmodulated beam with all the protons stopping in the aperture and an aperture-to-isocenter distance of 30 cm, the H/D values measured at the isocenter were approximately 0.3 mSv/Gy for all snouts with a 100-MeV beam. The H/D values increased to 10.7, 14.5, and 15.1 mSv/Gy, respectively, for small, medium, and large snouts when the beam energy increased to 250 MeV. At the out-of-field location, H/D values increased from 0.1 to 2.7, 3.0, and 3.2 mSv/Gy, respectively, for small, medium, and large snouts. When the aperture-to-isocenter distance was changed from 10 to 40 cm, the H/D value at the isocenter dropped 70%. The H/D value doubled for the modulated beam relative to the nonmodulated beam. Open apertures reduced the neutrons produced in the nozzle, but increased those produced in the phantom. Conclusions: Our data showed that changes in the four factors studied affect the H/D value in predictable ways which permits an estimate of a patient's neutron exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local atomic configurations in mechanically alloyed amorphous (FeCoNi) 70 Ti 10 B 20 powders

Here, the atomic structure of amorphous (FeCoNi) 70 Ti 10 B 20 alloy synthesized by mechanical alloying was investigated using high energy synchrotron X-ray diffraction and inverse Monte Carlo simulations of pair distribution functions. Empirical potential structure refinement indicates a chemical short-range order at the length scales of 2.1–2.5 Å via local atomic arrangements forming deformed bcc-like clusters. The structural model obtained was described by bond lengths, coordination numbers, and bond angle distribution functions determined for the first neighbor atoms by x-ray scattering supplemented with 3D Monte Carlo simulations.

36 MATERIALS SCIENCE↗

A new spherical harmonics scheme for multi-dimensional radiation transport I. Static matter configurations

Recent work by McClarren and Hauck (2010) [31] suggests that the filtered spherical harmonics method represents an efficient, robust, and accurate method for radiation transport, at least in the two-dimensional (2D) case. We extend their work to the three-dimensional (3D) case and find that all of the advantages of the filtering approach identified in 2D are present also in the 3D case. We reformulate the filter operation in a way that is independent of the timestep and of the spatial discretization. We also explore different second- and fourth-order filters and find that the second-order ones yield significantly better results. Overall, our findings suggest that the filtered spherical harmonics approach represents a very promising method for 3D radiation transport calculations.

97 MATHEMATICS AND COMPUTING↗

Deep glassy state dynamic data challenge glass models: Configurational entropy models

This work was the result of the student's (Dongjie Chen) qualifying exam response. In it the experimental observation from our labs that the relaxation times of ultrastable glasses (a 20 million year old amber and a vapor deposited amorphous teflon) do not follow the expected Vogel-Fulcher or WLF types of divergence as the temperatures fall below the glass transition temperature. In the work we evaluated several theories by considering them in different ways. We used them as generally used and show that they do not capture the non-diverging behavior. Because the models were all entropy-based models, we also considered the possibility that the temperature dependence of the entropy used in the models is incorrect and chose two ways of estimating the entropy that do not follow the classical theoretical models. First we used the actually measured calorimetric response for the two ultrastable glasses, and we used the Milchev model, which does not go to zero above 0 Kelvin. Both of these approaches led to improved agreement between the theories and the experimental data. Finally, we also asked what the temperature dependence of the entropy would have to be so that the models agreed with the observed data. In some cases the entropy so-calculated was reasonable, while in others it was unphysical. In sum, the important point of the work is that the observation of non-diverging time-scales that suggest that there is no ideal glass transition can be reasonably captured by current theories if they take more realistic models of the entropy than is usually the case.