Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Coronary risk equivalence of diabetes assessed by SPECT-MPI

Background: Several publications and guidelines designate diabetes mellitus (DM) as a coronary artery disease (CAD) risk equivalent. The aim of this investigation was to examine DM cardiac risk equivalence from the perspective of stress SPECT myocardial perfusion imaging (MPI). Methods and Results: We examined cardiovascular outcomes (cardiac death or nonfatal MI) of 17,499 patients referred for stress SPECT-MPI. Patients were stratified into four categories: non-DM without CAD, non-DM with CAD, DM without CAD, and DM with CAD, and normal or abnormal perfusion. Cardiac events occurred in 872 (5%), with event-free survival best among non-DM without CAD, worst in DM with CAD, and intermediate in DM without CAD, and non-DM with CAD. After multivariate adjustment, risk remained comparable between DM without CAD and non-DM with CAD [AHR 1.0 (95% CI 0.84–1.28), P =0.74]. Annualized event rates for normal subjects were 1.4% and 1.6% for non-DM with CAD and DM without CAD, respectively (P = 0.48) and 3.5% (P = 0.95) for both abnormal groups. After multivariate adjustment, outcomes were comparable within normal [AHR 1.4 (95% CI 0.98–1.96) P = 0.06] and abnormal [AHR 1.1 (95% CI 0.83–1.50) P = 0.49] MPI. Conclusions: Diabetic patients without CAD have comparable risk of cardiovascular events as non-diabetic patients with CAD after stratification by MPI results. These findings support diabetes as a CAD equivalent and suggest that MPI provides additional prognostic information in such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Additional value of systolic wall thickening in myocardial stunning evaluated by stress-rest gated perfusion SPECT

Aim and patients: The aim of the present study is to evaluate the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning in patients with angiography proven coronary artery disease. We selected 91 ischemic patients (82 males; mean age 59.7 ± 10.3) with CAD documented by angiography. Ischemia was defined as a summed difference score ≥5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of {sup 99m}Tc-tetrofosmin after stress and at rest. Treadmill maximal exercise tests were performed on all patients. Results: The post-stress LVEF was significantly lower than rest LVEF (48.1% ± 10.3% vs 50.3% ± 10.7%; P = .0001). The wall thickening summed difference score was 4.44 ± 4.13 (P = .0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS). We also divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. Conclusions: WT-SDS, more than the depression in the global function (∆LVEF) of the left ventricle, correlates with the degree of ischemia and better identifies, when present, the stunning phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI

Objective: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Methods: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ({sup 13}N-NH{sub 3}: 813 ± 86 MBq) and metabolism ({sup 18}F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Results: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Conclusion: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET/CT for the quantification of inflammation in large carotid artery plaques

Background: There is currently no consensus on the methodology for quantification of {sup 18}F-FDG uptake in inflammation in atherosclerosis. In this study, we explore different methods for quantification of {sup 18}F-FDG uptake in carotid atherosclerotic plaques and correlate the uptake values to histological assessments of inflammation. Methods and Results: Forty-four patients with atherosclerotic stenosis ≥70% of the internal carotid artery underwent {sup 18}F-FDG PET/CT. Maximum standardized uptake values (SUV{sub max}) from all plaque-containing slices were collected. SUV{sub max} for the single highest and the mean of multiple slices with and without blood background correction (by subtraction (cSUV) or by division (target-to-background ratio (TBR)) were calculated. Following endarterectomy 30 plaques were assessed histologically. The length of the plaques at CT was 6-32 mm. The {sup 18}F-FDG uptake in the plaques was 1.15-2.66 for uncorrected SUVs, 1.16-3.19 for TBRs, and 0.20-1.79 for cSUVs. There were significant correlations between the different uptake values (r = 0.57-0.99, P < 0.001). Methods with and without blood background correction showed similar, moderate correlations to the amount of inflammation assessed at histology (r = 0.44-0.59, P < 0.02). Conclusions: In large stenotic carotid plaques, {sup 18}F-FDG uptake reflects the inflammatory status as assessed at histology. Increasing number of PET slices or background correction did not change the correlation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake

Objective: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. Methods: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). Results: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. Conclusion: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complete revascularization determined by myocardial perfusion imaging could improve the outcomes of patients with stable coronary artery disease, compared with incomplete revascularization and no revascularization

Objectives: To compare the outcomes among patients treated by complete coronary revascularization (CCR) or incomplete coronary revascularization (ICR) and no coronary revascularization (NCR) by myocardial perfusion imaging (MPI), as well as to evaluate the impact of severity of ischemia on patients with coronary artery disease (CAD) by different therapy strategies. Background: Using myocardial ischemia severity determined by MPI guiding treatment strategies for CAD patients still lacks strong clinical evidences. Methods: Consecutive patients (N = 286) underwent clinical stress-rest SPECT MPI and were retrospectively followed-up. For assessment of outcome of treatment, all patients were classified into three groups (CCR, ICR, and NCR), and further divided into two subgroups as mild ischemia (< 10% ischemic myocardium) and moderate-severe ischemia (≥ 10% ischemic myocardium). All-cause death was defined as the primary endpoint, and the composite of deaths, nonfatal myocardial infarction, and repeat revascularization (MACE) as the secondary endpoint. Results: Two-hundred eighty-six patients were followed-up for 46 ± 21 months. Thirty deaths and 65 MACEs were recorded. Patients treated by revascularization had significantly lower MACE (P < .001) but not mortality (P = .158) than patients treated by NCR. Outcomes of CCR related to mortality rate were greater than ICR and NCR (death: P = .019, MACE: P < .001). In patients with moderate-severe ischemia, CCR showed improved outcomes than ICR and NCR (death: P = .034; and MACE: P < .001). In patients with mild ischemia, the outcomes of CCR, ICR, and NCR had no significant difference (P > .05). Multivariate regression Cox analysis revealed that summed difference score [death: HR 1.09 (1.03, 1.15), P = .004] was an independent risk factor and CCR was an independent negative predictor [death: HR 0.31 (0.12, 0.81), P = .017; MACE: HR 0.30 (0.16, 0.57), P < .001]. Conclusions: Outcomes of patients treated by CCR were most likely more promising in comparison with treatment of ICR and NCR, especially when patients had over 10% ischemic myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

My warranty has expired: I need to be retested

The concept of warranty period, the duration of time during which the patient’s risk remains low, is appealing. However, some points remain to be resolved before its translation in the clinical arena. Methodological issues should be standardized in order to compare the results of studies in different patient populations. Also, the definition of a “normal” study should always take into consideration the history of prior revascularization, the achieved level of exercise, and the stressor used. The promise of warranty can be questioned by the patient’s baseline demographic and clinical characteristics and may also be influenced by life-style modification in the course of the follow-up. The “warranty period” concept should shift from data reflecting the time to a cardiac event to the development of ischemia, given an opportunity for intervention before a cardiac event occurs. In this context, clarify the role of serial imaging can be extremely useful, in particular to evaluate if and when retesting a patient after a normal scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems

Background: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems. Methods: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans. Results: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype. Conclusions: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of stress testing for low-risk patients with chest discomfort in the emergency department

Background: The management of patients presenting to an emergency department with chest discomfort at low-risk for acute coronary syndrome represents a common clinical challenge. Such patients are often triaged to chest pain units for monitoring and cardiac stress testing for further risk stratification. Methods: We conducted a retrospective study of 292 low-risk patients who presented to an emergency department with chest discomfort. We performed physician-adjudicated chart reviews of all patients with positive stress tests to assess downstream testing, subsequent coronary revascularization, and outcomes. Results: Of the 292 patients, 33 (11.3%) had stress tests positive for ischemia, and 12 (4.1%) underwent diagnostic cardiac catheterization. Of the 292 patients, 4 (1.4%) underwent coronary revascularization that may have resulted in a mortality benefit. Conclusion: These data suggest a very low yield of detecting clinically significant coronary disease with stress testing low-risk patients with chest discomfort in emergency department chest pain units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging

This phantom-based study was aimed to determine whether cardiac CZT-cameras, which provide an enhanced spatial resolution and image contrast compared to Anger cameras, are similarly affected by small cardiac motions. Translations of a left ventricular (LV) insert at half-SPECT acquisitions through six possible orthogonal directions and with 5- or 10-mm amplitude were simulated on the Discovery NM-530c and DSPECT CZT-cameras and on an Anger Symbia T2 camera equipped with an astigmatic (IQ.SPECT) or conventional parallel-hole collimator (Conv.SPECT). SPECT images were initially reconstructed as currently recommended for clinical routine. The heterogeneity in recorded activity from the 17 LV segments gradually increased between baseline and motions simulated at 5- and 10-mm amplitudes with all cameras, although being higher for Anger- than CZT-cameras at each step and resulting in a higher mean number of artifactual abnormal segments (at 10-mm amplitude, Conv.SPECT: 3.7; IQ.SPECT: 1.8, Discovery: 0.7, DSPECT: 0). However, this vulnerability to motion was markedly (1) decreased for Conv.SPECT reconstructed without the recommended Resolution Recovery algorithm and (2) increased for DSPECT reconstructed without the recommended cardiac model. CZT-cameras and especially the DSPECT appear less vulnerable to small cardiac motions than Anger-cameras although these differences are strongly dependent on reconstruction parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗