Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUPLED MODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Modeling quantum state transport with SQMS devices

To scale up the Hilbert space of architectures for quantum computation involving microwave cavities, we need to control more and more photons states. A big step forward in this direction would be to connect two different cavities from a quantum mechanics point of view. In this report, we will discuss which experimental approach would be feasible to transfer a quantum state from one cavity to another. To perform this task, we will take advantage of the secondary modes of the cavities, discussing how a variable coupling between the cavity modes could help us in this process. In the end, we will see how we can create entanglement between the cavities from this procedure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The period structure of the ZZ Ceti variables

The current observational status of the period structure of ZZ Ceti stars is reviewed, and in particular those features which appear to be the most important for theory to explain, or which may be relevant to the directions of theoretical development are discussed. Mechanisms to explain the broad range of period structure are suggested. Multiple nonradial modes, probably corresponding to different radial overtones, may be simultaneously excited in each star. The excitation energy of individual stars is distributed among permitted modes by nonlinear resonant coupling. In addition, rotational splitting of the nonradial modes can produce closely spaced periods which results in modulation of the light curve. Amplitude/spectral complexity correlation results from the appearance in the power spectrum of harmonics and cross-frequencies which are the effects brought on by increasing nonlinearity of the pulsations.

Mcgraw, J. T.↗

High-power single-element pseudomorphic InGaAs/GaAs/AlGaAs single quantum well lasers for pumping Er-doped fiber amplifiers

A 980-nm-ridge waveguide pseudomorphic InGaAs/GaAs/AlGaAs single-quantum-well laser with a maximum single-ended output power of 240 mW from a facet-coated device is fabricated from a graded-index separate-confinement heterostructure grown by molecular-beam epitaxy. The laser oscillates in the fundamental spatial mode, allowing 22 percent coupling efficiency into a 1.55-micron single-mode optical fiber. Life testing at an output power of 30 mW per facet from uncoated devices reveals a superior reliability to GaAs/AlGaAs quantum-well lasers but also the need for protective facet coatings for long term reliability at power levels required for pumping Er-doped fiber amplifiers.

Larsson, A.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Surface plasmon-mediated energy transfer of electrically-pumped excitons

An electrically pumped light emitting device emits a light when powered by a power source. The light emitting device includes a first electrode, a second electrode including an outer surface, and at least one active organic semiconductor disposed between the first and second electrodes. The device also includes a dye adjacent the outer surface of the second electrode such that the second electrode is disposed between the dye and the active organic semiconductor. A voltage applied by the power source across the first and second electrodes causes energy to couple from decaying dipoles into surface plasmon polariton modes, which then evanescently couple to the dye to cause the light to be emitted.

30 DIRECT ENERGY CONVERSION↗

High quality factor non-uniform metasurfaces

High quality factor electromagnetic metasurfaces are provided. The metasurface is configured to have in plane guided-mode resonances (e.g., corresponding to waveguide modes or the like). Coupling features are included in the metasurface that are configured to couple free-space radiation to the guided mode resonances. The resulting structures have a high-Q response to free-space radiation and can be used for various applications, such as beam splitting, beam steering, and beam focusing or defocusing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient Coupler for a Bessel Beam Dispersive Element

A document discusses overcoming efficient optical coupling to high orbital momentum modes by slightly bending the taper dispersive element. This little shape distortion is not enough to scramble the modes, but it allows the use of regular, free-beam prism coupling, fiber coupling, or planar fiber on-chip coupling with, ultimately, 100 percent efficiency. The Bessel-beam waveguide is bent near the contact with the coupler, or a curved coupler is used. In this case, every Bessel-beam mode can be successfully coupled to a collimated Gaussian beam. Recently developed Bessel-beam waveguides allow long optical delay and very high dispersion. Delay values may vary from nanoseconds to microseconds, and dispersion promises to be at 100 s/nm. Optical setup consisted of a red laser, an anamorphic prism pair, two prism couplers, and a bent, single-mode fiber attached to prisms. The coupling rate increased substantially and corresponded to the value determined by the anamorphic prism pair.

Savchenkov, Anatoliy↗

Avalanche transport of energetic-ions in magnetic confinement plasmas: nonlinear multiple wave-number simulation

Large burst activity, identified as toroidal Alfvén eigenmode (TAE) avalanche, occurs frequently in neutral-beam heated plasmas in National Spherical Torus Experiment (NSTX). Based on the typical experimental observation of TAE avalanche on NSTX, a self-consistent nonlinear multiple wave-number (k ∥ ≃ n/R, where n toroidal mode-number and R major radius) simulation associated with TAE avalanches is performed using the experimental parameters and profiles before the occurrence of TAE avalanche as the M3D-K input. The wave–wave nonlinear coupling among different modes and the resonant interaction between different modes and energetic-ions during TAE avalanches are identified in the nonlinear multiple wave-number simulations. The resonance overlap during the TAE avalanche is clearly observed in the simulation. It is found that the effective wave–wave coupling and a sufficiently strong drive are two important ingredients for the onset of TAE avalanches. TAE avalanche is considered to be a strongly nonlinear process and it is always accompanied by the simultaneous rapid frequency-chirping and large amplitude bursting of multiple modes and significant energetic-ion losses. The experimental phenomenon is observed on NSTX and is qualitatively reproduced by the simulation results in this work. These findings indicate that the onset of avalanche is triggered by nonlinearity of the system, and are also conducive to understanding the underlying mechanism of avalanche transport of energetic particles in the future burning plasmas, such as International Thermonuclear Experiment Reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Examination of Launch Vehicle Loads Reanalysis Techniques

The typical approach to calculating dynamic launch loads in aerospace applications is coupled loads analysis (CLA). A component mode model of the launch vehicle is coupled with a component mode model of a payload, system modes are calculated, forcing functions are applied, and the dynamic responses are computed. This approach requires the explicit knowledge of the component models for the launch vehicle and payload, as well as the forcing functions. In many situations, the launch vehicle and forcing functions do not change from one analysis to the next only the payload is different. For this type of application, a method called reanalysis was developed to compute the response of a modified payload on the same launch vehicle. If the launch forcing functions are also the same, the approach eliminates the need for the launch vehicle model and the forcing functions and dramatically reduces the computation time. This work investigates the application and accuracy of three previously developed reanalysis methods using a typical launch vehicle and two different payloads. All three methods are based on knowledge of system modes from the original CLA, and Hurty/Craig-Bampton (HCB) models of the original and new payloads. The first method was developed at JPL (Jet Propulsion Lab) and is often referred to as substitution. It is a frequency-domain method, which requires transformation of time signals to and from the frequency domain. The other two methods are time-domain methods that more closely mimic the CLA process. The three methods were applied to two simple examples and a more complex one. The results indicate that the time-domain methods are considerably more robust with respect to modal truncation and other numerical errors than the frequency-domain JPL method.

Reanalysis↗

Low-frequency shear Alfvén waves at DIII-D: Theoretical interpretation of experimental observations

The linear properties of the low-frequency shear Alfvén waves such as those associated with the beta-induced Alfvén eigenmodes (BAEs) and the low-frequency modes observed in reversed-magnetic-shear DIII-D discharges [W. Heidbrink et al., Nucl. Fusion 61, 066031 (2021)] are theoretically investigated and delineated based on the theoretical framework of the general fishbone-like dispersion relation (GFLDR). By adopting representative experimental equilibrium profiles, it is found that, even though both modes are predominantly of Alfvénic polarization, the low-frequency mode is a reactive unstable mode with weak coupling to the energetic particles, while the BAE involves a dissipative instability due to resonant excitation by the energetic ions. Thus, the low-frequency mode is more appropriately called a low-frequency Alfvén mode (LFAM). Moreover, the ascending frequency spectrum patterns of the experimentally observed BAEs and LFAMs can be theoretically reproduced by varying qmin and also be well interpreted based on the GFLDR. The present analysis illustrates the solid predictive capability of the GFLDR and its practical usefulness in enhancing the interpretative capability of both experimental and numerical simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of optical coupling in microdisk resonators

In this paper, optical properties of coupled silica disk microresonators are investigated. The spectral response and the light intensity distribution along the coupled disks were measured. It was found that the distribution depends on the particular excited resonance, which can be attributed to the formation of normal modes of the coupled resonator system. A developed theoretical model gives quantitative agreement with the experimental observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic Microwave Background Polarization Detector with High Efficiency, Broad Bandwidth, and Highly Symmetric Coupling to Transition Edge Sensor Bolometers

Four probe antennas transfer signals from waveguide to microstrip lines. The probes not only provide broadband impedance matching, but also thermally isolate waveguide and detector. In addition, we developed a new photonic waveguide choke joint design, with four-fold symmetry, to suppress power leakage at the interface. We have developed facilities to test superconducting circuit elements using a cryogenic microwave probe station, and more complete systems in waveguide. We used the ring resonator shown below to measure a dielectric loss tangent < 7x10(exp -4) over 10 - 45 GHz. We have combined component simulations to predict the overall coupling from waveguide modes to bolometers. The result below shows the planar circuit and waveguide interface can utilize the high beam symmetry of HE11 circular feedhorns with > 99% coupling efficiency over 30% fractional bandwidth.

Wollack, E.↗

Unified quantum jump superoperator for optical fields from the weak- to the strong-coupling limit

We derive a generalized quantum jump superoperator that can be used in the quantum trajectory description of single photon detectors, light-emitting diodes (LEDs), and lasers. Our model describes an optical single-mode cavity field coupled to a reservoir through a two-state quantum system and includes three physical parameters: the coupling of the field to the two-state system, the coupling of the two-state system to the reservoir, and the cavity loss rate. In this setup, the two-state system can act as a photodetector or as an energy-adding mechanism. In the first case, we assume that the reservoir acts as a damping mechanism for an ideal cavity and derive reduced field operators describing the photon detection events. Our model coincides with the commonly known quantum trajectory based photon counting models at the weak- and strong-coupling limits and is, furthermore, also applicable between their validity regimes. In the second case, we assume that the reservoir injects energy into a lossy cavity through the two-state system. Again we derive the reduced field operators describing photon creation events into the lossy cavity. We show that this setup can act as an LED or as a laser depending on the strength of the injection. We also investigate how the setup operates at the close proximity of the lasing threshold.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear dynamics of multiple neoclassical tearing modes in tokamaks

Numerical simulations investigating the interaction of co-existent 2/1 and 3/1 neoclassical tearing modes are presented. The results obtained from an initial value 3D toroidal code that solves a set of generalized reduced MHD equations exhibit a host of complex phenomena arising from the coupling of the two modes. These include a modification of the island saturation widths of the two modes, a significant modification in the perpendicular flow patterns in the vicinity of the islands, and the excitation of geodesic acoustic mode like oscillations that lead to concomitant oscillations in the kinetic and magnetic energies of the islands. These oscillations only occur in the presence of the neoclassical stress tensor contribution and are absent for two coupled classical tearing modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of free shear layers

The fundamental aspects of controlled multiple coherent mode presence in turbulent shear flows is first discussed, including the supplementary averaging procedures in addition to the Reynolds average and the nonlinear energy transfer mechanisms coupling the coherent modes, mean flow and fine-grained turbulence. Then the problem of a fundamental mode and its subharmonic in a developing mixing layer, the prototype problem of subharmonic cascade, is examined. An integral method is presented which allows the determination of the coherent wave envelope or amplitude simultaneously with the mean flow growth rate and turbulence energy. This is then generalized to the presence of multiple subharmonics using a binary-frequency interaction argument. Free shear layer control is discussed in terms of initial coherent mode amplitudes, dimensionless initial frequencies, phase angle between the modes and fine-grained turbulence levels, in particular, how these parameters could enhance or suppress the shear layer spreading rate and the levels of fine-grained turbulence.

Liu, J. T. C.↗

Efficient vibration mode analysis of aircraft with multiple external store configurations

A coupling method for efficient vibration mode analysis of aircraft with multiple external store configurations is presented. A set of low-frequency vibration modes, including rigid-body modes, represent the aircraft. Each external store is represented by its vibration modes with clamped boundary conditions, and by its rigid-body inertial properties. The aircraft modes are obtained from a finite-element model loaded by dummy rigid external stores with fictitious masses. The coupling procedure unloads the dummy stores and loads the actual stores instead. The analytical development is presented, the effects of the fictitious mass magnitudes are discussed, and a numerical example is given for a combat aircraft with external wing stores. Comparison with vibration modes obtained by a direct (full-size) eigensolution shows very accurate coupling results. Once the aircraft and stores data bases are constructed, the computer time for analyzing any external store configuration is two to three orders of magnitude less than that of a direct solution.

Karpel, M.↗

Analysis of Alfvén eigenmode destabilization by energetic particles in Large Helical Device using a Landau-closure model

Here, energetic particle populations in nuclear fusion experiments can destabilize the Alfvén Eigenmodes through inverse Landau damping and couplings with gap modes in the shear Alfvén continua. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles. We add the Landau damping and resonant destabilization effects using a closure relation. We apply the model to study the Alfvén mode stability in the inward-shifted configurations of the Large Helical Device (LHD), performing a parametric analysis of the energetic particle β (${{\beta}_{f}}$ ) in a range of realistic values, the ratios of the energetic particle thermal/Alfvén velocities (${{V}_{\text{th}}}/{{V}_{A0}}$ ), the magnetic Lundquist numbers (S) and the toroidal modes (n). The n = 1 and n = 2 TAEs are destabilized, although the n = 3 and n = 4 TAEs are weakly perturbed. The most unstable configurations are associated with the density gradients of energetic particles in the plasma core: the TAEs are destabilized, even for small energetic particle populations, if their thermal velocity is lower than 0.4 times the Alfvén velocity. The frequency range of MHD bursts measured in the LHD are 50–70 kHz for the n = 1 and 60–80 kHz for the n = 2 TAE, which is consistent with the model predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗