Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Emission

The University of Kentucky Center for Applied Energy Research (UKy-CAER) designed, constructed and tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. Evaluation of emissions from the solvent and degradation products was performed to determine the impact on the amine solvent of coal combustion flue gas contaminants and oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall amine, ammonia and aldehyde emission levels observed during the baseline 30% monoethanolamine (MEA) solvent testing campaign were generally comparable to previously published reports tested at similar flue gas conditions and system operating hours. Ammonia emissions were correlated to high levels of iron and copper in the solvent, likely as a result of material corrosion.

20 FOSSIL-FUELED POWER PLANTS↗

SU-E-T-399: Evaluation of Selection Criteria for Computational Human Phantoms for Use in Out-Of-Field Organ Dosimetry for Radiotherapy Patients

Purpose: To quantify the dosimetric uncertainty due to organ position errors when using height and weight as phantom selection criteria in the UF/NCI Hybrid Phantom Library for the purpose of out-of-field organ dose reconstruction. Methods: Four diagnostic patient CT images were used to create 7-field IMRT plans. For each patient, dose to the liver, right lung, and left lung were calculated using the XVMC Monte Carlo code. These doses were taken to be the ground truth. For each patient, the phantom with the most closely matching height and weight was selected from the body size dependent phantom library. The patient plans were then transferred to the computational phantoms and organ doses were recalculated. Each plan was also run on 4 additional phantoms with reference heights and or weights. Maximum and mean doses for the three organs were computed, and the DVHs were extracted and compared. One sample t-tests were performed to compare the accuracy of the height and weight matched phantoms against the additional phantoms in regards to both maximum and mean dose. Results: For one of the patients, the height and weight matched phantom yielded the most accurate results across all three organs for both maximum and mean doses. For two additional patients, the matched phantom yielded the best match for one organ only. In 13 of the 24 cases, the matched phantom yielded better results than the average of the other four phantoms, though the results were only statistically significant at the .05 level for three cases. Conclusion: Using height and weight matched phantoms does yield better results in regards to out-of-field dosimetry than using average phantoms. Height and weight appear to be moderately good selection criteria, though this selection criteria failed to yield any better results for one patient.

60 APPLIED LIFE SCIENCES↗

Analysis of strapdown sensor testing

Some topics related to dynamic testing of strapdown sensors are analyzed, with emphasis on measuring parameters which give rise to motion-induced error torques in single-degree-of-freedom inertial sensors. The objective is to determine the dynamic inputs, test equipment characteristics and data processing procedures best suited for measuring these parameters. Single axis, low frequency vibration tests and constant rate tests are studied in detail. Methods for analyzing the effects of test motion errors and measurement errors are developed and illustrated by examples. Candidate test data processing methods are compared and recommendations concerning test equipment and data processing are made.

Crawford, B. S.↗

Effects of reset stators and a rotating, grooved stator hub on performance of a 1.92-pressure-ratio compressor stage

The overall performance and blade-element performance of a transonic fan stage are presented for two modified test configurations and are compared with the unmodified stage. Tests were conducted with reset stators 2 deg open and reset stators with a rotating grooved stator hub. Detailed radial and circumferential (behind stator) surveys of the flow conditions were made over the stable operating range at rotative speeds of 70, 90, and 100 percent of design speed. Reset stator blade tests indicated a small increase in stage efficiency, pressure ratio, and maximum weight flow at each speed. Performance with reset stators and a rotating, grooved stator hub resulted in an additional increase in stage efficiency and pressure ratio at all speeds. The rotating grooved stator hub reduced hub losses considerably.

Lewis, G. W., Jr.↗

Laboratory evaluation of the pointing stability of the ASPS Vernier System

The annular suspension and pointing system (ASPS) is an end-mount experiment pointing system designed for use in the space shuttle. The results of the ASPS Vernier System (AVS) pointing stability tests conducted in a laboratory environment are documented. A simulated zero-G suspension was used to support the test payload in the laboratory. The AVS and the suspension were modelled and incorporated into a simulation of the laboratory test. Error sources were identified and pointing stability sensitivities were determined via simulation. Statistical predictions of laboratory test performance were derived and compared to actual laboratory test results. The predicted mean pointing stability during simulated shuttle disturbances was 1.22 arc seconds; the actual mean laboratory test pointing stability was 1.36 arc seconds. The successful prediction of laboratory test results provides increased confidence in the analytical understanding of the AVS magnetic bearing technology and allows confident prediction of in-flight performance. Computer simulations of ASPS, operating in the shuttle disturbance environment, predict in-flight pointing stability errors less than 0.01 arc seconds.

Source record↗

Flight and tunnel test results of the MDC mechanical jet noise suppressor nozzle

The flight and wind tunnel tests to determine the acoustic and performance effects of a mechanical jet noise suppressor nozzle mounted on a Viper engine of an HS-125 airplane are discussed. Flyover noise measurements were made with microphones mounted on top of a 137.5 m bridge tower. Seven nozzle configurations including two references nozzles, two suppressors, and three ejector inlets were tested. The suppressor nozzle of interest for an advanced supersonic transport, the suppressor/treated ejector, achieved a measured noise reduction of 14 EPNdB relative to a conventional conical reference nozzle at the highest pressure ratio tested (approximately 2.5). The unique engine nacelle, flight hardware, and nacelles from the HS-125 flight test program, combined with a simulated HS-125 fuselage were windtunnel tested. Both propulsion and acoustic data were recorded. Preliminary thrust data results from the wind tunnel tests are summarized and compared to other mechanical suppressor test results. The test results indicate that a noise reduction of at least 16 EPNdB would be possible for the suppressor/ejector nozzle scaled to typical AST engine size with a 5% thrust loss at a typical takeoff climb speed.

Fitzsimmons, R. D.↗

Offgassing Characterization of the Columbus Laboratory Module

Trace gaseous contamination in the cabin environment is a major concern for manned spacecraft, especially those designed for long duration missions, such as the International Space Station (ISS). During the design phase, predicting the European-built Columbus laboratory module s contribution to the ISS s overall trace contaminant load relied on "trace gas budgeting" based on material level and assembled article tests data. In support of the Qualification Review, a final offgassing test has been performed on the complete Columbus module to gain cumulative system offgassing data. Comparison between the results of the predicted offgassing load based on the budgeted material/assembled article-level offgassing rates and the module-level offgassing test is presented. The Columbus module offgassing test results are also compared to results from similar tests conducted for Node 1, U.S. Laboratory, and Airlock modules.

Rampini, riccardo↗

LISA Pathfinder

USA Pathfinder is a space mission dedicated to demonstrating technology for the Laser Interferometer Space Antenna (LISA). LISA is a joint ESA/NASA mission to detect low-frequency gravitational waves on the 0.0001 to 0.1 Hz frequency band. LISA is expected to observe 100's of merging massive black hole binaries out z-15, tens of thousands of close compact binary systems in the Milky Way, merging intermediate-mass black hole binaries, tens of stellar-mass black holes falling into supermassive black holes in galactic centers, and possibly other exotic sources. Several critical LISA technologies have not been demonstrated at the requisite level of performance. In spaceflight, and some fight hardware cannot be tested in a 1-g environment. Hence, the LISA Pathfinder mission is being implemented to demonstrate these critical LISA technologies in a relevant flight environment. LISA Pathfinder mimics one arm of the LISA constellation by shrinking the 5-million-kilometer armlength down to a few tens of centimeters. The experimental concept is to measure the relative separation between two test masses nominally following their own geodesics, and thereby determine the relative residual acceleration between them near 1 mHz, about a decade above the lowest frequency required by LISA. To implement such a concept, disturbances on the test masses must be kept very small by many design features, but chiefly by "drag-free" flight. A drag-free spacecraft follows a free-falling test mass which it encloses, but has no mechanical connection to. The spacecraft senses it's orientation and separation with respect to the proof mass, and its propulsion system is commanded to keep the spacecraft centered about the test mass. Thus, the spacecraft shields the test mass from most external influences, and minimizes the effect of force gradients arising from the spacecraft, and acting on the test mass. LISA Pathfinder will compare the geodesic of one test mass against that of the other. Only a metrology system based on interferometry can achieve the displacement sensitivity. Interferometers monitor the separation of both test masses with a sensitivity comparable to that required by LISA, and using the same technologies. LISA Pathfinder is scheduled to be launched in the first half of 1020 to a Lissajous orbit around the first Sun-Earth Lagrange point, L1. In addition to a complete European technology package (the LISA Technology Package, or LTP), LISA Pathfinder will also carry thrusters and software, known as ST-7, a part of NASA's New Millennium Program.

Stebbins, Robin↗

Cryogenic Testing of Different Seam Concepts for Multilayer Insulation Systems

Recent testing in a cylindrical, comparative cryostat at the Cryogenics Test Laboratory has focused on various seam concepts for multilayer insulation systems. Three main types of seams were investigated: straight overlap, fold-over, and roll wrapped. Each blanket was comprised of 40 layer pairs of reflector and spacer materials. The total thickness was approximately 12.5-mm, giving an average layer density of 32 layers per centimeter. The blankets were tested at high vacuum, soft vacuum, and no vacuum using liquid nitrogen to maintain the cold boundary temperature at 77 K. Test results show that all three seam concepts are all close in thermal performance; however the fold-over method provides the lowest heat flux. For the first series of tests, seams were located 120 degrees around the circumference of the cryostat from the previous seam. This technique appears to have lessened the degradation of the blanket due to the seams. In a follow-on test, a 20 layer blanket was tested in a roll wrapped configuration and then cut down the side of the cylinder, taped together, and re-tested. This test result shows the thermal performance impact of having the seams all in one location versus having the seams clocked around the vessel. This experimental investigation indicates that the method of joining the seams in multilayer insulation systems is not as critical as the quality of the installation process.

Johnson, Wesley L.↗

Cassini Stellar Reference Unit: Performance Test Approach and Results

The Cassini Stellar Reference Unit (SRU) is the prime attitude determination sensor on the Cassini spacecraft...To ensure that the SRU will operate within specification for the entire mission, an extensive test program has been undertaken to characterize the SRU performance prior to launch and to quantify any expected performance degradation. Results from several eomplimentary test programs are presented and compared with pre-test performance predictions.

star↗

Sympathetic responses to Valsalva's manoeuvre following bed rest

The purpose of this study was to examine whether 14 days of head-down tilt bed rest (HDBR) alters autonomic regulation during Valsalva's manoeuvre (VM) and if this would predict blood pressure control during a 60 degrees head-up tilt (HUT) test. To examine autonomic control of blood pressure, we measured the changes in systolic (delta SBP) and diastolic (delta DBP) blood pressure between baseline and the early straining (Phase IIE) period of VM (20 sec straining to 40 mmHg; N = 7) in conjunction with changes in muscle sympathetic nerve activity (MSNA; microneurography) burst frequency (B/min) and total activity (% delta) from baseline over the 20-sec straining period. MSNA data were successfully recorded from 6 of the 7 individuals. The averaged responses from three repeated VMs performed in the supine position were compared between the pre- and post-HDBR tests. Compared with the pre-HDBR test, a greater reduction in SBP, DBP, and MAP was observed during Phase IIE following HDBR, p < 0.05. The increase in MSNA burst frequency during straining was augmented in the post- compared with the pre-HDBR test, p < 0.0001, as was the Phase IV blood pressure overshoot, p < 0.05. Although all subjects completed the 20-min pre-HDBR tilt test without evidence of hypotension or orthostatic intolerance, the post-HDBR test was stopped early in 5 of the 7 subjects due to systolic hypotension. The responses during the VM suggest that acute autonomic adjustments to rapid blood pressure changes are preserved after bed rest. Furthermore, MSNA and blood pressure responses during VM did not predict blood pressure control during orthostasis following HDBR.

NASA Discipline Musculoskeletal↗

Femtosecond time-domain phase comparator

Phase shift in test device is measured by summing output of mixer with ramp voltage and comparing time interval between zero crossings of summed signal and ramp reference frequency. Circuit can be used to test devices at other frequencies by changing only signal source, phase splitter, and mixer; divider and time-interval counter need not be driven by oscillator.

Donahoe, T.↗

Turbulence Measurements on a 2D NACA 0036 with Synthetic Jet Flow Control

An active flow control experiment was conducted on a 2-ft chord NACA 0036 airfoil in a 3-ft by 4-ft Wind Tunnel at Re = 1 x 10(exp 6). The model was equipped with synthetic jet actuators at x/c = 0.30 and 0.65 that provided 120 Hz periodic excitation at a C(sub mu) 0.86% through 0.06-in wide slots. Three different slot con gurations were tested, including a baseline with no slots. Surface pressure data was collected to compare to previous tests and to combine with turbulence data to aid future CFD modeling efforts. Turbulence data, measured by hot-wire, was compared with and without flow control. Pressure data corroborates previous test data and provides more points for CFD validation. Hot-wire results showed ow control reduced the separated wake size and brought the high Reynolds stress shear layer closer to the airfoil surface. The position of this layer to the surface was altered more significantly than the magnitude of the peak stresses. Flow control was shown to increase turbulent energy in the attached boundary layer downstream of the slot but to have little effect upstream. These results provide further justification to continue assessing the potential of active flow control to reduce drag of helicopter airframe components.

Wilson, J. S.↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

The wave energy converter control competition (WECCCOMP): Wave energy control algorithms compared in both simulation and tank testing

The wave energy control competition established a benchmark problem which was offered as an open challenge to the wave energy system control community. The competition had two stages: In the first stage, competitors used a standard wave energy simulation platform (WEC-Sim) to evaluate their controllers while, in the second stage, competitors were invited to test their controllers in a real-time implementation on a prototype system in a wave tank. The performance function used was based on converted energy across a range of standard sea states, but also included aspects related to economic performance, such as peak/average power, peak force, etc. This paper compares simulated and experimental results and, in particular, examines if the results obtained in a linear system simulation are borne out in reality. Overall, within the scope of the device tested, the range of sea states employed, and the performance metric used, the conclusion is that high-performance WEC controllers work well in practice, with good carry-over from simulation to experimentation. However, the availability of a good WEC mathematical model is deemed to be crucial.

16 TIDAL AND WAVE POWER↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

Gas Generation Testing of Spherical Resorcinol-Formaldehyde (sRF) Resin

This report describes gas generation testing of the spherical resorcinol-formaldehyde (sRF) resin that was conducted to support the technology maturation of the LAWPS facility. The current safety basis for the LAWPS facility is based primarily on two studies that had limited or inconclusive data sets. The two studies indicated a 40% increase in hydrogen generation rate of water (as predicted by the Hu model) with sRF resin over water alone. However, the previous studies did not test the range of conditions (process fluids and temperatures) that are expected in the LAWPS facility. Additionally, the previous studies did not obtain replicate test results or comparable liquid-only control samples. All of the testing described in this report, conducted with water, 0.45M nitric acid, and waste simulants with and without sRF resin, returned hydrogen generation rates that are within the current safety basis for the facility of 1.4 times the Hu model output for water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗