Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Build System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tools and Tool Support for the Exascale Era

The goal of this paper is to highlight the challenges in providing scalable tool support on exascale class machines and to identify key research and development needs as well as opportunities to meet these challenges. In this context we define tool support very broadly as software that helps programmers to understand, optimize and fix their codes as well as software that facilitates interaction between application, run-time, and hardware. This includes tools for performance analysis, static and run-time optimization, debugging, correctness verification and program transformation. This paper is intended as background material for the ASC exascale workshop, held in March 2011 in San Francisco, to stimulate discussion both within the tools area and across working groups. Further, this paper targets both the issues and requirements users have on tools in the exascale era as well as the requirements that need to be fulfilled by exascale systems to build scalable tools.

97 MATHEMATICS AND COMPUTING↗

Matrix Algebra for GPU and Multicore Architectures (MAGMA) for Large Petascale Systems

The goal of the MAGMA project is to create a new generation of linear algebra libraries that achieve the fastest possible time to an accurate solution on hybrid Multicore+GPU-based systems, using all the processing power that future high-end systems can make available within given energy constraints. Our efforts at the University of Tennessee achieved the goals set in all of the five areas identified in the proposal: 1. Communication optimal algorithms; 2. Autotuning for GPU and hybrid processors; 3. Scheduling and memory management techniques for heterogeneity and scale; 4. Fault tolerance and robustness for large scale systems; 5. Building energy efficiency into software foundations. The University of Tennessee’s main contributions, as proposed, were the research and software development of new algorithms for hybrid multi/many-core CPUs and GPUs, as related to two-sided factorizations and complete eigenproblem solvers, hybrid BLAS, and energy efficiency for dense, as well as sparse, operations. Furthermore, as proposed, we investigated and experimented with various techniques targeting the five main areas outlined.

97 MATHEMATICS AND COMPUTING↗

Greenbuilt Retrofit Test House Final Report

The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hazards to satellites from the space environment [Slides]

Space weather is a dynamic environment that can affect spacecraft. These particles can cause problems to spacecraft through either degradation from AO, shorting from discharging or radiation effects. Radiation effects for spacecraft continue to be a challenge, but extensive testing and modeling allows spacecraft designers to build robust systems that can survive the space weather environment.

Engineering(42)↗

An In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes

Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and lighting, appliance, and miscellaneous loads (LAMELs) through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and LAMELs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Versatile Formal Methods Applied to Quantum Information.

Using a novel formal methods approach, we have generated computer-veri ed proofs of major theorems pertinent to the quantum phase estimation algorithm. This was accomplished using our Prove-It software package in Python. While many formal methods tools are available, their practical utility is limited. Translating a problem of interest into these systems and working through the steps of a proof is an art form that requires much expertise. One must surrender to the preferences and restrictions of the tool regarding how mathematical notions are expressed and what deductions are allowed. Automation is a major driver that forces restrictions. Our focus, on the other hand, is to produce a tool that allows users the ability to con rm proofs that are essentially known already. This goal is valuable in itself. We demonstrate the viability of our approach that allows the user great exibility in expressing state- ments and composing derivations. There were no major obstacles in following a textbook proof of the quantum phase estimation algorithm. There were tedious details of algebraic manipulations that we needed to implement (and a few that we did not have time to enter into our system) and some basic components that we needed to rethink, but there were no serious roadblocks. In the process, we made a number of convenient additions to our Prove-It package that will make certain algebraic manipulations easier to perform in the future. In fact, our intent is for our system to build upon itself in this manner.

97 MATHEMATICS AND COMPUTING↗

Advanced Metering Installations – A Perspective from Federal Sites

This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stevens Institute SYS-625 Final Paper: Busy Parents Need Extremely Fast, Quality Home-Cooked Dinners That Their Kids Will Eat

This study provides a modern take on an age-old need: busy parents need extremely fast, high quality home-cooked dinners that their kids will eat. In the past decade, the number of choices that parents have for filling this need have proliferated, largely due to technological advances. Our study proposes to leverage this technology in building a system geared toward decreasing whining in kids and increasing the sanity of their parents.

42 ENGINEERING↗

Impact of Different Vegetative Cover Scenarios on Infiltration Rates for the E-Area PA Intact Case

This memorandum addresses the effects of vegetative cover type (bamboo versus Bahia grass) and the timing of pine tree intrusion on intact infiltration rate for the proposed E-Area Low-Level Waste Facility (LLWF) closure cap system. It builds upon earlier reports whose purpose is to lay the foundation for the infiltration data package that will be assembled during the next revision of the E-Area LLWF Performance Assessment (PA).

54 ENVIRONMENTAL SCIENCES↗

Building a Cyberinfrastructure for Environmental System Science: Modeling Frameworks, Data Management, and Scientific Workflows, Workshop Report, Potomac, Maryland, April 30-May 1, 2015

The Environmental System Science (ESS) activity within the Department of Energy’s (DOE) Office of Biological and Environmental Research (BER) seeks to advance a robust, predictive understanding of terrestrial environments, extending from bedrock to the top of the vegetative canopy and from molecular to global scales, through an iterative cycle of model-driven experimentation and observation dubbed MODEX. Considerable progress has been made toward achieving this overarching goal, but widely recognized is the fragmentation across projects and disciplines of the relevant modeling and simulation capabilities, observational and experimental data, analysis algorithms, and workflow tools. This fragmentation creates significant challenges for studying impacts and feedbacks in these complex multiscale systems. These challenges are further exacerbated by ongoing disruptive changes in high-performance computational architectures and the exponential growth in the types and volume of data that render obsolete the conventional approaches to software development and data management. Overcoming these challenges will require the development of a BER Climate and Environmental Sciences Division (CESD)–wide enabling cyberinfrastructure to support data management, cross-domain modeling, data analysis, and collaborative research. To explore the potential for working groups to initiate and guide a more integrated and community-based cyberinfrastructure, BER held the ESS Workshop on Model-Data Integration: Modeling Frameworks, Data Management, and Scientific Workflows on April 30-May 1, 2015, following the ESS Principal Investigator Meeting in Potomac, Maryland. Participants included model developers, software engineers, and data management specialists from eight national laboratories, which represented a wide range of projects and programs from CESD as well as cross-cutting projects from DOE’s Office of Advanced Scientific Computing Research (ASCR; both BER and ASCR are operated from within DOE’s Office of Science). A series of plenary talks provided background information and clarified the workshop’s three objectives: (1) develop requirements for this community-based cyberinfrastructure to ensure enhanced scientific productivity of the community as a whole; (2) identify challenges associated with developing this new cyberinfrastructure using a phased approach guided by project-driven use cases; and, given these requirements and challenges, (3) chart a path forward for ESS working groups to lead the phased development of the new cyberinfrastructure.

54 ENVIRONMENTAL SCIENCES↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mosaics , The Best of Both Worlds: Analog devices with Digital Spiking Communication to build a Hybrid Neural Network Accelerator

Neuromorphic architectures have seen a resurgence of interest in the past decade owing to 100x-1000x efficiency gain over conventional Von Neumann architectures. Digital neuromorphic chips like Intel's Loihi have shown efficiency gains compared to GPUs and CPUs and can be scaled to build larger systems. Analog neuromorphic architectures promise even further savings in energy efficiency, area, and latency than their digital counterparts. Neuromorphic analog and digital technologies provide both low-power and configurable acceleration of challenging artificial intelligence (AI) algorithms. We present a hybrid analog-digital neuromorphic architecture that can amplify the advantages of both high-density analog memory and spike-based digital communication while mitigating each of the other approaches' limitations.

97 MATHEMATICS AND COMPUTING↗