Polarisation singularities in the electric field at a sum-frequency generated by two collinear elliptically polarised Gaussian beams in the bulk of a nonlinear gyrotropic medium

Polarisation singularities in the electric field at a sum-frequency generated in the bulk of an isotropic gyrotropic medium with a quadratic nonlinearity are predicted to appear in the case of the collinear interaction of two uniformly elliptically polarised Gaussian beams. The parameters of the fundamental waves are found, corresponding to the formation of lines with circular and linear polarisations (C- and L-lines) in the cross section of the beam at the sum-frequency as well as to the appearance of the regions in the signal beam where the polarisation state varies smoothly from the left-hand circularly polarised state to the right-hand circularly polarised. In this case, the ellipticity degree of the polarisation ellipse takes all possible values, while its orientation remains unchanged. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine-Protection System for the PIP-II Linear Accelerator: Architecture and Data Processing Schemes

PIP-II at Fermilab features a brand-new, 800 MeV leading-edge Linear Accelerator (Linac) that will enable the Fermilab complex to deliver more than a megawatt of beam power to the Long Base-line Neutrino Facility (LBNF), requiring a robust Machine Protection System (MPS) to prevent beam-induced damage to delicate cryomodules and vacuum components. Signals in various accelerator components, in both analog and digital format, are collected and processed to assest the operating conditions of the accelerator. In the situation a potential damage is foreseen, the beam permit signal will be drop. A critical element of this system is the fast Analog Machine Protection System, a high-bandwidth platform designed for real-time beam loss monitoring. The system utilizes a modular, FPGA-based architecture to digitize signals from beam-sensing devices, such as AC Current Transformers (ACCTs), non-invasive Ring Pickups (RPUs) and beam scrapers. To eliminate both high frequency as well as 60 Hz noise that might be picked up in the industrial environment, data processing schemes beyond regular digital filtering are planned and implemented.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗

A New Method for Production of the Sr-82 Generator Radionuclide and Other Medical Radionuclides

A cyclotron (C-80) designed to produce protons with an energy of 40–80 MeV and beam intensity of 100–200 μA has been launched at the Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute. The main task of C-80 is the production of a wide range of medical radionuclides for diagnosis and therapy. A complex named Radioactive Isotopes on the C-80 Cyclotron (RIC-80) and intended to function on the C-80 beam was developed for this purpose. A brief description of the RIC-80 complex is given, and the results of the use of new methods and studies of target devices for the production of the generator radioisotope {sup 82}Sr; {sup 223}Ra, {sup 224}Ra, and {sup 225}Ac radioisotopes that undergo alpha-decay; {sup 67}Cu; and other medical radionuclides are presented. The use of a mass separator in the “on-line” mode to obtain ion beams of high-purity radioisotopes is a distinctive feature of the complex used in the project, and it is especially important for medical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Optical Emission Spectroscopy and Cavity Ring-Down Spectroscopy in Large-Scaled Negative-Ion Source

Optical emission spectroscopy (OES) and cavity ring-down spectroscopy (CRDS) systems are installed in a 1/3-scaled negative hydrogen-ion source at the National Institute for Fusion Science testbed to investigate the dynamics of H{sup -} ions in the extraction region near the plasma grid. The signal form of the H{sup -} ion density rapidly drops after beam extraction on applying a low-bias voltage. A similar signal drop appears in the intensity of the hydrogen Balmer-line emission measured by OES and is caused by decreasing atomic hydrogen produced by mutual neutralization effects between H{sup -} and H{sup +}. Shot trend of the beam currents are similar to the H{sup -} density and H{sub {alpha}}/H{sub {beta}} in the extraction region, which increases twice as large immediately after Cs seeding. We observe a linear correlation between the H{sup -} density and the inclination of H{sub {alpha}}/H{sub {beta}} which allows for experimentally benchmarking the OES measurement with that of CRDS. Thus, this approach is used for estimating the H{sup -} density by OES in negative-ion sources for high-energy neutral beam injector.

43 PARTICLE ACCELERATORS↗

Solving the auroral-arc-generator question by using an electron beam to unambiguously connect critical magnetospheric measurements to auroral images

Here, an active mapping mission is described that unambiguously connects measurements in the Earth's magnetosphere to visible aurora in the atmosphere. The core of the mission is an electron-beam source operated on a spacecraft in the equatorial magnetosphere, with the electron beam traveling along the Earth's magnetic-field lines to the atmosphere, depositing its energy to create an optical beam-spot in the atmosphere at the footpoint of the spacecraft's magnetic-field line. This optical spot can be imaged by ground-based cameras, putting the location of the spacecraft's magnetic footpoint into the context of the optical aurora. Scientific instruments carried on the spacecraft make critical measurements of the properties of the magnetosphere at the locations where the magnetosphere powers the aurora, allowing the determination of the plasma-physics mechanisms by which the magnetosphere drives the aurora, in particular answering the outstanding question of how the magnetosphere drives low-latitude auroral arcs. Long-standing questions in magnetosphere-ionosphere coupling that have not been answered because we could not unambiguously connect locations in the magnetosphere with their image in the ionosphere will finally be addressed. In this paper the properties of a “standard” growth-phase auroral arc are collected, theories of the magnetospheric generation of auroral arcs are reviewed, and critical magnetospheric measurements to discern the mechanisms that drive auroral arcs are determined. Further, the plasma physics of the experiment is investigated, including spacecraft-charging mitigation, beam stability, beam scattering, and electron orbit theory. Tradeoffs (keV versus MeV) concerning the energy of the electron beam are enumerated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Transition Radiation System for ATF2

In this paper we present the first measurements performed during the fall 2010 and early 2011 runs. Software development, simulations and hardware improvements to the Multi-Optical Transition Radiation System installed in the beam diagnostic section of the Extraction line of ATF2 are described. 2D emittance measurements have been performed and the system is being routinely used for coupling correction. Realistic beam simulations have been made and compared with the measurements. A demagnifier lens system to improve the beam finding procedure has been designed and will be implemented in a future run. We also discuss further work planned for the subsequent run periods.

43 PARTICLE ACCELERATORS↗

SU-E-T-510: Interplay Between Spots Sizes, Spot / Line Spacing and Motion in Spot Scanning Proton Therapy

Purpose In proton beam configuration for spot scanning proton therapy (SSPT), one can define the spacing between spots and lines of scanning as a ratio of given spot size. If the spacing increases, the number of spots decreases which can potentially decrease scan time, and so can whole treatment time, and vice versa. However, if the spacing is too large, the uniformity of scanned field decreases. Also, the field uniformity can be affected by motion during SSPT beam delivery. In the present study, the interplay between spot/ line spacing and motion is investigated. Methods We used four Gaussian-shape spot sizes with 0.5cm, 1.0cm, 1.5cm, and 2.0cm FWHM, three spot/line spacing that creates uniform field profile which are 1/3*FWHM, σ/3*FWHM and 2/3*FWHM, and three random motion amplitudes within, +/−0.3mm, +/−0.5mm, and +/−1.0mm. We planned with 2Gy uniform single layer of 10×10cm2 and 20×20cm2 fields. Then, mean dose within 80% area of given field size, contrubuting MU per each spot assuming 1cGy/MU calibration for all spot sizes, number of spots and uniformity were calculated. Results The plans with spot/line spacing equal to or smaller than 2/3*FWHM without motion create ∼100% uniformity. However, it was found that the uniformity decreases with increased spacing, and it is more pronounced with smaller spot sizes, but is not affected by scanned field sizes. Conclusion It was found that the motion during proton beam delivery can alter the dose uniformity and the amount of alteration changes with spot size which changes with energy and spot/line spacing. Currently, robust evaluation in TPS (e.g. Eclipse system) performs range uncertainty evaluation using isocenter shift and CT calibration error. Based on presented study, it is recommended to add interplay effect evaluation to robust evaluation process. For future study, the additional interplay between the energy layers and motion is expected to present volumetric effect.

60 APPLIED LIFE SCIENCES↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spacecraft Observations of Oblique Electron Beams Breaking the Frozen-In Law During Asymmetric Reconnection

Fully kinetic simulations of asymmetric magnetic reconnection reveal the presence of magnetic-field-aligned beams of electrons flowing toward the topological magnetic x line. Within the ~ 6d e electron-diffusion region, the beams become oblique to the local magnetic field, providing a unique signature of the electron-diffusion region where the electron frozen-in law is broken. These numerical predictions are confirmed by in situ Magnetospheric Multiscale spacecraft observations during asymmetric reconnection at Earth’s dayside magnetopause.

79 ASTRONOMY AND ASTROPHYSICS↗

Operation of the NSLS-II Injector with a Lower Booster Injection Energy

The NSLS-II injector consists of a 200 MeV linac and a 3 GeV full-energy booster synchrotron. The linac contains five traveling-wave S-band accelerating structures driven by two high-power klystrons. Optimization of the NSLS-II injector has continued since user operation started in October 2014. Beam losses have been minimized by the injector tuning and stabilization, and high level software has been developed to characterize the booster and injection parameters. However, due to the recently increased frequency of klystrons arcing which shortens the lifetime of the klystron, operation of the linac with lowered klystron output power would allow injection to be maintained with fewer trips and extended lifetime of klystrons. Apart from the energy difference, the low energy klystron operation is quite similar to the nominal 200 MeV operation. Injection trials were carried out with scaled magnet settings of the linac, linac-to- booster (LtB) transport line, and the booster. The beam was successfully injected into the booster on May 31, 2017 at the low energy mode of the 170 MeV LtB injection. Overall transfer efficiency from the linac to the storage ring is identical to the standard 200 MeV operation. The 170 MeV injection mode has been adopted in NSLS-II user operation ever since the beam study. In the most recent injector studies on June 28 and July 3, 2017, the booster injection energy was further decremented to the final target value of 100 MeV via applying the same method established in the 170 MeV operation. The ultimate value of 100 MeV is determined by the special requirement of operating the injector at single klystron while repairing the other klystron or with two klystrons with significantly reduced outputs for the purpose of maximizing klystron lifetimes.

36 MATERIALS SCIENCE↗

Bands of ions and angular V's - A conjugate manifestation of ionospheric ion acceleration

Data from the hot plasma instruments on Dynamics Explorer 1 and 2 spacecraft have been used to study the injection, drift, and subsequent precipitation of suprathermal positive ions in the auroral zone. The observation at both high and low altitudes of electron inverted 'V' events in the boundary plasma sheet (BPS) and of ion 'bands' (energy decreasing with decreasing latitude) in the adjacent central plasma sheet (CPS) leads to the following ion injection model: upward-moving energetic ion beams are injected onto BPS magnetic field lines by the electrostatic potential drops associated with electron inverted V's. As the ion beams move toward the equator and into the conjugate hemisphere they are convected to lower latitudes and into the CPS. The energy-latitude dependence of the ion bands, coupled with concurrent ion convection measurements, indicate that the ion distributions are primarily O(+), in agreement with their postulated ionospheric source.

Winningham, J. D.↗

Finding beam loss locations in a linac with oscillating dipole correctors

The paper proposes a method of finding the beam loss locations in a linac. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync produces a line at the corresponding frequency in spectra of current-sensitive devices downstream of the loss point. The phase of this signal contains information about the location of the beam loss. Similar lines appear also in the position signals of Beam Position Monitors (BPMs). The phases of the BPM position lines change monotonically (within each 2π) along the linac and can be used a reference system. The phase of the loss signal compared with this reference system pinpoints the beam loss location, assuming that longitudinal coordinates of the BPMs are known. If the correctors deflection amplitudes and the phase offset between their waveforms are chosen optimally and well calibrated, the same measurement provides values of the β-function and the betatron phase advance at the BPM locations. Optics measurements of this type can be made parasitically, with negligible effect on the emittance, if a long measurement time is acceptable.

43 PARTICLE ACCELERATORS↗

Electron beam coupling to a metamaterial structure

Microwave metamaterials have shown promise in numerous applications, ranging from strip lines and antennas to metamaterial-based electron beam driven devices. In general, metamaterials allow microwave designers to obtain electromagnetic characteristics not typically available in nature. High Power Microwave (HPM) sources have in the past drawn inspiration from work done in the conventional microwave source community. In this article, the use of metamaterials in an HPM application is considered by using an effective medium model to determine the coupling of an electron beam to a metamaterial structure in a geometry similar to that of a dielectric Cerenkov maser. Use of the effective medium model allows for the analysis of a wide range of parameter space, including the “mu-negative,”“epsilon-negative,” and “double negative” regimes of the metamaterial. The physics of such a system are modeled analytically and by utilizing the particle-in-cell code ICEPIC. For this geometry and effective medium representation, optimum coupling of the electron beam to the metamaterial, and thus the optimum microwave or RF production, occurs in the epsilon negative regime of the metamaterial. Given that HPM tubes have been proposed that utilize a metamaterial, this model provides a rapid method of characterizing a source geometry that can be used to quickly understand the basic physics of such an HPM device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. The most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.

36 MATERIALS SCIENCE↗

High-resolution laser spectroscopy and magnetic effect of the B{sup ~2}E′ ← X{sup ~2}A{sub 2}′ transition of {sup 14}NO{sub 3} radical

Rotationally resolved high-resolution fluorescence excitation spectra of {sup 14}NO{sub 3} radical have been observed for the 662 nm band, which is assigned as the 0–0 band of the B{sup ~2}E′ ←X{sup ~2}A{sub 2}′ transition, by crossing a single-mode laser beam perpendicularly to a collimated molecular beam. More than 3000 rotational lines were detected in 15 070–15 145 cm{sup −1} region, but it is difficult to find the rotational line series. Remarkable rotational line pairs, whose interval is about 0.0246 cm{sup −1}, were found in the observed spectrum. This interval is the same amount with the spin-rotation splitting of the X{sup ~2}A{sub 2}′ (υ = 0, k = 0, N = 1) level. From this interval and the observed Zeeman splitting up to 360 G, seven line pairs were assigned as the transitions to the {sup 2}E′{sub 3/2} (J′ = 1.5) levels and 15 line pairs were assigned as the transitions to the {sup 2}E′{sub 1/2} (J′ = 0.5) levels. From the rotational analysis, we recognized that the {sup 2}E′ state splits into {sup 2}E′{sub 3/2} and {sup 2}E′{sub 1/2} by the spin-orbit interaction and the effective spin-orbit interaction constant was roughly estimated as –21 cm{sup −1}. From the number of the rotational line pairs, we concluded that the complicated rotational structure of this 662 nm band of {sup 14}NO{sub 3} mainly owes to the vibronic interaction between the B{sup ~2}E′ state and the dark A{sup ~2}E″ state through the a{sub 2}″ symmetry vibrational mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Density measurement in air with a saturable absorbing seed gas

Resonantly enhanced scattering from the iodine molecule is studied experimentally for the purpose of developing a scheme for the measurement of density in a gas dynamic flow. A study of the spectrum of iodine, the collection of saturation data in iodine, and the development of a mathematical model for correlating saturation effects were pursued for a mixture of 0.3 torr iodine in nitrogen and for mixture pressures up to one atmosphere. For the desired pressure range, saturation effects in iodine were found to be too small to be useful in allowing density measurements to be made. The effects of quenching can be reduced by detuning the exciting laser wavelength from the absorption line center of the iodine line used (resonant Raman scattering). The signal was found to be nearly independent of pressure, for pressures up to one atmosphere, when the excitation beam was detuned 6 GHz from line center for an isolated line in iodine. The signal amplitude was found to be nearly equal to the amplitude for fluorescence at atmospheric pressure, which indicates a density measurement scheme is possible.

Baganoff, D.↗

Flow-Tagging Velocimetry for Hypersonic Flows Using Fluorescence of Nitric Oxide

We investigate a new type of flow-tagging velocimetry technique for hypersonic flows. The technique involves exciting a thin line of nitric oxide molecules with a laser beam and then, after some delay, acquiring an image of the displaced line. One component of velocity is determined from the time of flight. This method is applied to measure the velocity profile in a Mach 8.5 laminar, hypersonic boundary layer in the Australian National Universities T2 free-piston shock tunnel. The velocity is measured with an uncertainty of approximately 2%. Comparison with a CFD simulation of the flow shows reasonable agreement.

Danehy, P. M.↗

Shielding maze design for Line C tunnel at LANSCE - 25456

The Los Alamos Neutron Science Center (LANSCE) is a major experimental facility at Los Alamos National Laboratory. The LANSCE linear accelerator (linac) supplies proton beams to five experimental areas simultaneously. The Isotope Production Facility (IPF) utilizes a 100-MeV beam after the first stage of acceleration, all other facilities use proton beams at 800 MeV. However, the facility can support sole-use experiments at 200-600 MeV proton beam energies. There are three spallation neutron sources providing neutrons in different energy regimes: Weapons Neutron Research (WNR), Lujan Neutron Scattering Center (Lujan Center) and the Ultra Cold Neutron source (UCN). The proton radiography (pRAD) facility utilizes the energetic proton beam for imaging and tomography directly. The beam to pRAD and UCN facilities is delivered via line X that splits into line C (pRAD) and line B (UCN). Due to engineering access controls it is impossible to deliver beam to UCN while the pRAD facility is occupied. The goal of our project was to design a shielding maze arrangement for line C to allow for simultaneous beam delivery to UCN while pRAD area (dome) is occupied. (authors)

43 PARTICLE ACCELERATORS↗