Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Power control for ac motor

A motor controller employing a triac through which power is supplied to a motor is described. The open circuit voltage appearing across the triac controls the operation of a timing circuit. This timing circuit triggers on the triac at a time following turn off which varies inversely as a function of the amplitude of the open circuit voltage of the triac.

Dabney, R. W.↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

MEMS closed-loop control incorporating a memristor as feedback sensing element

In this work the integration of a memristor with a MEMS parallel plate capacitor coupled by an amplification stage is simulated. It is shown that the MEMS upper plate position can be controlled up to 95% of the total gap. Due to its common operation principle, the change in the MEMS plate position can be interpreted by the change in the memristor resistance, or memristance. A memristance modulation of ~1 KΩ was observed. A polynomial expression representing the MEMS upper plate displacement as a function of the memristance is presented. Thereafter a simple design for a voltage closed-loop control is presented showing that the MEMS upper plate can be stabilized up to 95% of the total gap using the memristor as a feedback sensing element. As a result, the memristor can play important dual roles in overcoming the limited operation range of MEMS parallel plate capacitors and in simplifying read-out circuits of those devices by representing the motion of the upper plate in the form of resistance change instead of capacitance change.

42 ENGINEERING↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning with Adaptive Conservativeness for Distributionally Robust Optimization: Incentive Design for Voltage Regulation: Preprint

Information asymmetry between the Distribution System Operator (DSO) and Distributed Energy Resource Aggregators (DERAs) obstructs designing effective incentives for voltage regulation. To capture this effect, we employ a Stackelberg game-theoretic framework, where the DSO seeks to overcome the information asymmetry and refine its incentive strategies by learning from DERA behavior over multiple iterations. We introduce a model-based online learning algorithm for the DSO, aimed at inferring the relationship between incentives and DERA responses. Given the uncertain nature of these responses, we also propose a distributionally robust incentive design model to control the probability of voltage regulation failure and then reformulate it into a convex problem. This model allows the DSO to periodically revise distribution assumptions on uncertain parameters in the decision model of the DERA. Finally, we present a gradient-based method that permits the DSO to adaptively modify its conservativeness level, measured by the size of a Wasserstein metric-based ambiguity set, according to historical voltage regulation performance. The effectiveness of our proposed method is demonstrated through numerical experiments.

distribution system operator↗

The effect of dipole boron centers on the electroluminescence of nanoscale silicon p{sup +}−n junctions

Nanoscale silicon p{sup +}−;n junctions with very high concentration of boron, 5 10{sup 21} cm{sup −3}, are found to demonstrate interesting optical properties. Emission band dominated in near-infrared electroluminescence (EL) spectra possesses high degree of the linear polarization along preferred crystallographic axis which can be controlled by the lateral voltage applied in the plane of the p{sup +}−n junction. Such behavior together with the temperature dependence of the EL intensity is attributed to the presence of the self-compensating dipole boron centers, B{sup +}-B{sup −}, with negative correlation energy which are identified using the ESR technique in the nanoscale silicon p{sup +}−n junctions heavily doped with boron. The model of the recombination process though the negative-U dipole boron centers controlling the optical properties of the nanoscale silicon p{sup +}−n junctions is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Selection of the Optimum Electrospray Voltage for Gradient Elution LC-MS Measurements

Changes in liquid composition during gradient elution liquid chromatography (LC) and mass spectrometry (MS) analyses affect the electrospray operation. To establish methodologies for judicious selection of the electrospray voltage, we monitored in real-time the effect of the LC gradient on the spray current. The optimum range of the electrospray voltage shifted to lower values as the concentration of organic solvent in the eluent increased during reversed-phase LC analyses. These results provided the means to rationally select the voltage that ensured successful electrospray operation throughout gradient elution LC-MS experiments. A small run-to-run drift in the spray current was observed for electrosprays operated at constant voltage. This could be the result of fouling or degradation of the electrospray emitter, which affected the electric field driving the electrospray. Algorithms using feedback from spray current measurements to maintain the electrospray voltage within the optimum operating range throughout gradient elution LC-MS were evaluated. The electrospray operation with voltage regulation and at constant, judiciously selected voltage during gradient elution LC-MS measurements produced data with similar reproducibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Piezoelectric Power Requirements for Active Vibration Control

This paper presents a method for predicting the power consumption of piezoelectric actuators utilized for active vibration control. Analytical developments and experimental tests show that the maximum power required to control a structure using surface-bonded piezoelectric actuators is independent of the dynamics between the piezoelectric actuator and the host structure. The results demonstrate that for a perfectly-controlled system, the power consumption is a function of the quantity and type of piezoelectric actuators and the voltage and frequency of the control law output signal. Furthermore, as control effectiveness decreases, the power consumption of the piezoelectric actuators decreases. In addition, experimental results revealed a non-linear behavior in the material properties of piezoelectric actuators. The material non- linearity displayed a significant increase in capacitance with an increase in excitation voltage. Tests show that if the non-linearity of the capacitance was accounted for, a conservative estimate of the power can easily be determined.

Brennan, Matthew C.↗

An electromechanical actuation system for an expendable launch vehicle

A major effort at the NASA Lewis Research Center in recent years has been to develop electro-mechanical actuators (EMA's) to replace the hydraulic systems used for thrust vector control (TVC) on launch vehicles. This is an attempt ot overcome the inherent inefficiencies and costs associated with the existing hydraulic structures. General Dynamics Space Systems Division, under contract to NASA Lewis, is developing 18.6 kW (25 hp), 29.8 kW (40 hp), and 52.2 kW (70 hp) peak EMA systems to meet the power demands for TVC on a family of vehicles developed for the National Launch System. These systems utilize a pulse population modulated converter and field-oriented control scheme to obtain independent control of both the voltage and frequency. These techniques allow an induction motor to be operated at its maximum torque at all times. At NASA Lewis, we are building on this technology to develop our own in-house system capable of meeting the peak power requirements for an expendable launch vehicle (ELV) such as the Atlas. Our EMA will be capable of delivering 22.4 kW (30 hp) peak power with a nominal of 6.0 kW (8 hp). This system differs from the previous ones in two areas: (1) the use of advanced control methods, and (2) the incorporation of built-in-test. The advanced controls are essential for minimizing the controller size, while the built-in-test is necessary to enhance the system reliability and vehicle health monitoring. The ultimate goal of this program is to demonstrate an EMA which will be capable of self-test and easy integration into other projects. This paper will describe the effort underway at NASA Lewis to develop an EMA for an Atlas class ELV. An explanation will be given for each major technology block, and the status of each major technology block and the status of the overall program will be reported.

Burrows, Linda M.↗

Design of power electronics for TVC and EMA systems

The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently developing a class of electromechanical actuators (EMA's) for use in space transportation applications such as thrust vector control (TVC) and propellant control valves (PCV). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 volts. MSFC has selected the brushless dc motor for implementation in EMA's. A previous project performed by Auburn University examined the use of the resonant dc link (RDCL) inverter, pulse density modulation (PDM), and mos-controlled thyristors (MCT's) for speed control of a brushless dc motor. The speed of the brushless dc motor is proportional to the applied stator voltage. In a PDM system, the control system determines the number of resonant voltage pulses which must be applied to the stator to achieve a desired speed. The addition of a waveshaping circuit to the front end of a standard three-phase inverter yields a RDCL inverter; the resonant voltage pulses are produced through the action of this wave shaping circuit and the inverter. This project has focused on the implementation of a system which permits zero-voltage switching with the bus voltage clamped at the input voltage level. In the same manner as the RDCL inverter, the inverter selected for this implementation is a combination of waveshaping circuit and a standard three-phase inverter. In addition, this inverter allows a pulse-width modulated (PWM)-like control scheme instead of a PDM scheme. The operation of waveshaping circuit will be described through analysis and waveforms. Design relationships will also be presented.

Nelms, R. Mark↗

Self-formed copper oxide contact interlayer for high-performance oxide thin film transistors

Oxide thin film transistor employing copper source/drain electrodes shows a small turn on voltage and reduced hysteresis. Cross-sectional high-resolution transmission electron microscopy image confirmed the formation of ∼4 nm CuO{sub x} related interlayer. The lower bond-dissociation energy of Cu-O compared to Si-O and In-O suggests that the interlayer was formed by adsorbing oxygen molecules from surrounding environment instead of getting oxygen atoms from the semiconductor film. The formation of CuO{sub x} interlayer acting as an acceptor could suppress the carrier concentration in the transistor channel, which would be utilized to control the turn on voltage shifts in oxide thin film transistors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Numerical investigation of ion energy distribution and ion angle distribution in a dual-frequency capacitively coupled plasma with a hybrid model

A one-dimensional hybrid model is developed to study the characteristics of energy and angular distributions of the ions and fast neutrals impinging on the rf-biased electrode in a dual-frequency capacitively coupled Ar discharge. The hybrid model consists of a fluid model that determines the spatiotemporal evolution of the discharge, and a Monte-Carlo model that, including the electron-neutral, ion-neutral, and fast neutral-neutral collisions, predicts the energy and angular distributions of the ions and fast neutrals on the rf-biased electrode. The influence of pressure, voltage amplitude, and frequencies of the two rf sources on the energy and angular distributions is discussed. The ion energy distributions (IEDs) appear to have multiple peaks in the dual-frequency capacitively coupled rf discharge rather than bimodal shape in a conventional single-frequency rf discharge. The ion angle distributions (IADs) have a significant peak at a small angle, and most ions strike to the process surface with the angle less than 4 deg. With the increase of the pressure, the maximum energy of IEDs and the peaks of IADs decrease. The structures of IEDs are controlled mainly by the voltage and frequency applied to the two rf sources. By decreasing the frequency or adding the voltage applied to the low-frequency (LF) source, the width of IEDs and the maximum energy increase. More ions strike to the electrode with a small angle by increasing either the voltage of LF source or the frequency of high-frequency source. The energy and angular distributions of the fast neutrals are correlative with those of the ions. Compared with the ions, the fast neutrals have a much lower energy and the scattering effect becomes more prominent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Sizing and Placement of Battery Energy Storage in Distribution System Based on Solar Size for Voltage Regulation

This paper proposes a new strategy to achieve voltage regulation in distributed power systems in the presence of solar energy sources and battery storage systems. The goal is to find the minimum size of battery storage and its corresponding location in the network based on the size and place of the integrated solar generation. The proposed method formulates the problem by employing the network impedance matrix to obtain an analytical solution instead of using a recursive algorithm such as power flow. The required modifications for modeling the slack and PV buses (generator buses) are utilized to increase the accuracy of the approach. The use of reactive power control to regulate the voltage regulation is not always an optimal solution as in distribution systems R/X is large. In this paper the minimum size and the best place of battery storage is achieved by optimizing the amount of both active and reactive power exchanged by battery storage and its gridtie inverter (GTI) based on the network topology and R/X ratios in the distribution system. Simulation results for the IEEE 14-bus system verify the effectiveness of the proposed approach.

14 SOLAR ENERGY↗

On Distributed PV Hosting Capacity Estimation, Sensitivity Study, and Improvement

This paper first studies the estimated distributed PV hosting capacities of seventeen utility distribution feeders using the Monte Carlo simulation based stochastic analysis, and then analyzes the sensitivity of PV hosting capacity to both feeder and photovoltaic system characteristics. Furthermore, an active distribution network management approach is proposed to maximize PV hosting capacity by optimally switching capacitors, adjusting voltage regulator taps, managing controllable branch switches and controlling smart PV inverters. The approach is formulated as a mixed-integer nonlinear optimization problem and a genetic algorithm is developed to obtain the solution. Multiple simulation cases are studied and the effectiveness of the proposed approach on increasing PV hosting capacity is demonstrated.

14 SOLAR ENERGY↗

A Tradeoff Analysis of Series / Parallel Three-Phase Converter Topologies for Wireless Extreme Chargers

In this paper, extreme fast charging (XFC) technology is studied considering the charge rates of 300 kW for wireless power transfer (WPT) applications. Tradeoff analysis of series and parallel connection of three-phase WPT system are presented by comparisons of voltage and current stresses on power electronics active / passive components. In addition, star (Y) / delta (Δ) connection configurations for three-phase wireless power transfer coupling coils are analyzed with series and LCC resonant compensation circuits. The system series and parallel connection controllability is also reviewed considering voltage and current balance techniques with output control. In a conclusion of evaluation analysis, it is revealed that each component of 300 kW wireless charging network must be designed for high fast charging system and the overall system operation need to be strategically planned for high power charging and infrastructure deployment.

Asa, Erdem↗