The Design and Testing of the LSSIF Advanced Thermal Control System

The Life Support Systems Integration Facility (LSSIF) provides a platform to design and evaluate advanced manned space systems at NASA Johnson Space Center (JSC). The LSSIF Early Human Testing Initiative requires the integration of such subsystems to enable human occupancy of the 6 meter chamber for a 90 day closed volume test. The Advanced Thermal Control System (TCS) is an important component of the integrated system by supplying coolant to the subsystems within the chamber, such as the Air Revitalization System. The TCS incorporates an advanced high efficiency, heat pump to reject waste heat from the chamber to an external sink or 'lift' temperature that emulates a Lunar environment. The heat pump is the High Lift Heat Pump, developed by Foster-Miller, Inc., and is the main test article of the TCS. The heat pump prototype utilizes a non-CFC refrigerant in a design where the thermal requirements exceed existing terrestrial technology. These operating requirements provide a unique opportunity to design and test an advanced integrated thermal system and the associated controls. The design, control, and systems integration of the heat pump and the TCS also have terrestrial technology application. This paper addresses the design of the TCS and the heat pump, along with the control scheme to fully test the heat pump. Design approaches utilized in the LSSIF TCS are promoted for implementation in terrestrial thermal systems. The results of the preliminary thermal and fluid analyses used to develop the control of the thermal systems will also be discussed. The paper includes objectives for the 90 day human test and the test setup. Finally, conclusions will be drawn and recommendations for Earth design application are submitted.

Henson, Robert A.↗

Simultaneous Strain and Temperature Sensing using a Microstrip Patch Antenna

In this paper, we present simultaneous strain and temperature sensing using a single microstrip patch antenna fabricated on commercial printed circuit board (PCB). Temperature and strain are extracted from the resonant frequencies of the patch antenna as these frequencies are dependent on the dielectric constant of the PCB and the patch dimensions, which are subject to change with applied strain and temperature variations. The principle of operation of the patch antenna is first discussed, followed by the design and fabrication of the instrumented test specimen. Finally, thermal and mechanical tests were conducted to validate the strain and temperature sensing performance of the antenna sensor

TCHAFA, FRANCK MBANYA↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanisms Engineering Test Loop (METL) Operations, Maintenance, and Testing - FY2025

This report documents the operations, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) and its supporting infrastructure during FY2024. The METL facility had a very successful seventh year of operations while supporting the testing of multiple test article experiments in the facility. The METL facility continued supporting the Gear Test Assembly (GTA) testing and the Thermal Hydraulic Experimental Test Article (THETA) with the full testing with both the primary and secondary systems. Work to accommodate two additional experiments, a flow sensor test article (F-STAr) gripper test and a fuel handling gripper test article (GrTA) continued as they are expected to undergo testing in METL in FY2025. In addition, a new 18” test article, the Sample Testing Basket (STB) was used a few times to provide screening tests for sodium service materials. A fifth test vessel was installed in the location of Test Vessel 6, and a wet vapor nitrogen sodium processing system was developed and initially tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of structural engineering properties of incoloy 903 and CTX-1 alloys

Tension, notched tension, compression, density, thermal conductivity, and thermal expansion tests were conducted on Incoloy 903 over the temperature range 20 K (-423 F) through 1033 K (1400 F). Fracture toughness tests were performed at room temperature (RT). Creep and rupture tests were conducted at 811 K (1000 F), 922 K (1200 F), and 1033 K (1400 F) for this alloy. Transverse unnotched and notched fatigue tests at R = 0.1 were performed at RT and 922 K (1200 F). For CTX-1 alloy, tension, Charpy V-notch impact, density, thermal conductivity, and thermal expansion tests were conducted over the temperature range 20 K (-423 F) through 1033 K (1400 F). Poisson's ratio was determined at RT, 811 K (1000 F), 922 K (1200 F), and 1033 K (1400 F). Notched tension and compression tests were performed at 20 K (-423 F), RT, and 922 K (1200 F); plane strain fracture toughness tests were conducted at RT, 77 K (-320 F), and 20 K (-423 F). Creep and rupture tests were performed at 811 K (1000 F), 922 K (1200 F), and 1033 K (1400 F); longitudinal unnotched and notched fatigue tests at R = 0.1 were conducted at RT and 922 K (1200 F). Results are presented and discussed.

Ruff, P. E.↗

Centaur Standard Shroud (CSS) static ultimate load structural tests

A series of tests were conducted on the jettisonable metallic shroud used on the Titan/Centaur launch vehicle to verify its structural capabilities and to evaluate its structural interaction with the Centaur stage. A flight configured shroud and the interfacing Titan/Centaur structural assemblies were subjected to tests consisting of combinations of applied axial and shear loads to design ultimate values, including a set of tests on thermal conditions and two dynamic response tests to verify the analytical stiffness model. The strength capabilities were demonstrated at ultimate (125 percent of design limit) loads. It was also verified that the spring rate of the flight configured shroud-to-Centaur forward structural deflections of the specimen became nonlinear, as expected, above limit load values. This test series qualification program verified that the Titan/Centaur shroud and the Centaur and Titan interface components are qualified structurally at design ultimate loads.

Source record↗

Design, fabrication and test of graphite/polyimide composite joints and attachments for advanced aerospace vehicles

Results of an experimental program to develop several types of graphite/polyimide (GR/PI) bonded and bolted joints for lightly loaded flight components for advanced space transportation systems and high speed aircraft are presented. Tasks accomplished include: a literature survey; design of static discriminator specimens; design allowables testing; fabrication of test panels and specimens; small specimen testing; and standard joint testing. Detail designs of static discriminator specimens for each of the four major attachment types are presented. Test results are given for the following: (1) transverse tension of Celion 3000/PMR-15 laminate; (2) net tension of a laminate for both a loaded and unloaded bolt hole; (3) comparative testing of bonded and co-cured doublers along with pull-off tests of single and double bonded angles; (4) single lap shear tests, transverse tension and coefficient of thermal expansion tests of A7F (LARC-13 amide-imide modified) adhesive; and (5) tension tests of standard single lap, double lap, and symmetric step lap bonded joints. Also, included are results of a finite element analysis of a single lap bonded composite joint.

Barclay, D. L.↗

Thirteenth Space Simulation Conference. The Payload: Testing for Success

Information on the state of the art in space simulation, test technology, thermal simulation and protection, contamination, and test measurements and techniques are presented. Simulation of upper atmosphere oxygen was discussed. Problems and successes of retrieving and repairing orbiting spacecrafts by utilizing the shuttle are outlined.

Joseph L Stecher↗

Heat transfer in a real engine environment

The hot section facility at the Lewis Research Center was used to demonstrate the capability of instruments to make required measurements of boundary conditions of the flow field and heat transfer processes in the hostile environment of the turbine. The results of thermal scaling tests show that low temperature and pressure rig tests give optimistic estimates of the thermal performance of a cooling design for high pressure and temperature application. The results of measuring heat transfer coefficients on turbine vane airfoils through dynamic data analysis show good comparison with measurements from steady state heat flux gauges. In addition, the data trends are predicted by the STAN5 boundary layer code. However, the magnitude of the experimental data was not predicted by the analysis, particularly in laminar and transitional regions near the leading edge. The infrared photography system was shown capable of providing detailed surface thermal gradients and secondary flow features on a turbine vane and endwell.

Gladden, Herbert J.↗

Thermal contact conductance of pressurized surfaces

Thermal vacuum testing has demonstrated the feasibility of the concept of pressurizing contact surfaces for the transfer of waste heat on the Space Station. Data show a thin inflatable bladder design to provide a greater contact conductance than an expandable bellows approach, with substantially less interface volume to transfer the same amount of heat. Extended vacuum testing of the Radiator-to-Thermal Bus assembly indicated a continual increase of conductance as the interface was maintained at 150 psi for a 100-hour period.

Voss, Fred E.↗

International Ultraviolet Explorer (IUE) Battery History and Performance

The "International Ultraviolet Explorer (IUE) Battery History and Performance" report provides the information on the cell/battery design, battery performance during the thirty eight (38) solar eclipse seasons and the end-of-life test data. It is noteworthy that IUE spacecraft was an in-house project and that the batteries were designed, fabricated and tested (Qualification and Acceptance) at the Goddard Space Flight Center. A detailed information is given on the cell and battery design criteria and the designs, on the Qualification and the Acceptance tests, and on the cell life cycling tests. The environmental, thermal, and vibration tests were performed on the batteries at the battery level as well as with the interface on the spacecraft. The telemetry data were acquired, analyzed, and trended for various parameters over the mission life. Rigorous and diligent battery management programs were developed and implemented from time to time to extend the mission life over eighteen plus years. Prior to the termination of spacecraft operation, special tests were conducted to check the battery switching operation, battery residual capacity, third electrode performance and battery impedance.

Rao, Gopalskrishna M.↗

Development and Results of a First Generation Least Expensive Approach to Fission: Module Tests and Results

The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal-hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments and identifies future tests to be performed.

Houts, Mike↗

Development of the Orion Crew-Service Module Umbilical Retention and Release Mechanism

The Orion CSM umbilical retention and release mechanism supports and protects all of the cross-module commodities between the spacecrafts crew and service modules. These commodities include explosive transfer lines, wiring for power and data, and flexible hoses for ground purge and life support systems. The mechanism employs a single separation interface which is retained with pyrotechnically actuated separation bolts and supports roughly two dozen electrical and fluid connectors. When module separation is commanded, either for nominal on-orbit CONOPS or in the event of an abort, the mechanism must release the separation interface and sever all commodity connections within milliseconds of command receipt. There are a number of unique and novel aspects of the design solution developed by the Orion mechanisms team. The design is highly modular and can easily be adapted to other vehiclesmodules and alternate commodity sets. It will be flight tested during Orions Exploration Flight Test 1 (EFT-1) in 2014, and the Orion team anticipates reuse of the design for all future missions. The design packages fluid, electrical, and ordnance disconnects in a single separation interface. It supports abort separations even in cases where aerodynamic loading prevents the deployment of the umbilical arm. Unlike the Apollo CSM umbilical which was a destructive separation device, the Orion design is resettable and flight units can be tested for separation performance prior to flight.Initial development testing of the mechanisms separation interface resulted in binding failures due to connector misalignments. The separation interface was redesigned with a robust linear guide system, and the connector separation and boom deployment were separated into two discretely sequenced events. These changes addressed the root cause of the binding failure by providing better control of connector alignment. The new design was tuned and validated analytically via Monte Carlo simulation. The analytical validation was followed by a repeat of the initial test suite plus test cases at thermal extremes and test cases with imposed mechanical failures demonstrating fault tolerance. The mechanism was then exposed to the qualification vibration environment. Finally, separation testing was performed at full speed with live ordnance.All tests of the redesigned mechanism resulted in successful separation of the umbilical interface with adequate force margins and timing. The test data showed good agreement with the predictions of the Monte Carlo simulation. The simulation proved invaluable due to the number of variables affecting the separation and the uncertainty associated with each. The simulation allowed for rapid assessment of numerous trades and contingency scenarios, and can be easily reconfigured for varying commodity sets and connector layouts.

Separation↗

Performance Testing of a High Temperature Linear Alternator for Stirling Convertors

The NASA Glenn Research Center has conducted performance testing of a high temperature linear alternator (HTLA) in support of Stirling power convertor development for potential future Radioisotope Power Systems (RPS). The high temperature linear alternator is a modified version of that used in Sunpower's Advanced Stirling Convertor (ASC), and is capable of operation at temperatures up to 200 deg. Increasing the temperature capability of the linear alternator could expand the mission set of future Stirling RPS designs. High temperature Neodymium-Iron-Boron (Nd-Fe-B) magnets were selected for the HTLA application, and were fully characterized and tested prior to use. Higher temperature epoxy for alternator assembly was also selected and tested for thermal stability and strength. A characterization test was performed on the HTLA to measure its performance at various amplitudes, loads, and temperatures. HTLA endurance testing at 200 deg is currently underway.

Radioisotope Power System↗

Performance Testing of a High Temperature Linear Alternator for Stirling Convertors

The NASA Glenn Research Center has conducted performance testing of a high temperature linear alternator (HTLA) in support of Stirling power convertor development for potential future Radioisotope Power Systems (RPS). The high temperature linear alternator is a modified version of that used in Sunpowers Advanced Stirling Convertor (ASC), and is capable of operation at temperatures up to 200 C. Increasing the temperature capability of the linear alternator could expand the mission space of future Stirling RPS designs. High temperature Neodymium-Iron-Boron (Nd-Fe-B) magnets were selected for the HTLA application, and were fully characterized and tested prior to uses. Higher temperature epoxy for alternator assembly was also selected and tested for thermal stability and strength. A characterization test was performed on the HTLA to measure its performance at various amplitudes, loads, and temperatures. HTLA endurance testing at 200 C is currently underway.

Alternator Test Rig↗

Reliability of area array packages with 1500-2500 I/Os

This report first provides a literature survey for designing, manufacturing, and reliability test results for area array packages with 1500 to 2500 inputs/outputs (I/Os). It then presents test matrix on design, yield, and workmanship defects on assembly and environmental testing, including thermal cycle and mechanical drop-test evaluation results for FCBGA1704, FPBGA432, and PBGA676 I/Os packages assembled onto printed circuit/wiring boards (PCBs/PWBs). Finally, it summarizes lessons learned from test results for assembly and environmental testing along with optical, scanning electron microscopy (SEM), and x-ray photomicrographs showing damage progress.

Ghaffarian, Reza↗

Neutronics Analysis Supporting Baseline Fuel-Rodlet Irradiation Design in TREAT Multi-SERTTA Vehicle

The Transient Reactor Test (TREAT) Facility is a thermal-spectrum test reactor designed to evaluate reactor fuels and structural material under simulated nuclear excursion and transient power/cooling mismatch situations in nuclear reactors. TREAT was historically operated from 1959 through 1994. There are ongoing activities to resume its transient testing capabilities to support advanced reactor designs and validate computational predictions of fuel and core behavior. Such validation will be an important factor for review and approval of next generation power reactor design and safety evaluations. Historic methods used in TREAT were very approximate and served to estimate a predicted transient power shape. A number of calibration test experiments were then required prior to the actual transient test to better estimate the power that would have been deposited in the experiment during a transient pulse. Much of the experience in the use of these legacy methods has also been lost over the past two decades. Monte Carlo criticality codes are being utilized for calculation of the initial critical state, control rod reactivity worth, and power coupling between core and experiments. Current efforts primarily support neutronics characterization with safety and design analyses for the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses) experiment test vehicle, which can accommodate up to four concurrent rodlets under separate environmental conditions. Ongoing efforts are necessary in preparation of transient testing support for Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. The power coupling factor (PCF) is one of two key parameters utilized in designing and characterizing the performance of a TREAT fuel irradiation experiment. The second key parameter is the Transient Correction Factor (TCF) which accounts for time-dependent effects. The PCF is the effective quantity of fission-generated energy per mass of fuel specimen per total core energy. The quantity of energy deposited into a fuel rodlet under various test environments can be used to evaluate overall fuel performance, including failure mechanisms and thresholds. Baseline fuel rodlet calculations have been performed to estimate the effectiveness of the Multi-SERTTA test vehicle and optimization of PCF for various test conditions. The baseline serves as reference fuel pin conditions against which calibration and baseline experiments can be performed prior to actual ATF transient testing. Baseline experiments further serve to validate computational analyses and experimental test methods prior to design planning, experimentation, and evaluation of the ATF candidates. This paper serves to document activities performed to evaluate a reference Pressurized Water Reactor (PWR) rodlet design in the TREAT Multi-SERTTA test vehicle. (authors)