Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf For EnergyPlus® and OpenStudio®, generation of test cases, simulation, and reporting has been a manual or partially automated process that typically took a number of months after a new version of EnergyPlus came out. Building Energy Simulation Test - Generation Simulation and Reporting (BESTEST-GSR) was developed to fully automate this process so it is less error-prone, less time-consuming, and can be quickly run on request for any development branch of EnergyPlus and OpenStudio. The initial use case is to directly support OpenStudio and EnergyPlus development, but the software is configured to support use by external software developers that build tools on top of EnergyPlus and/or OpenStudio. Tools built on top of OpenStudio can leverage the test generation, simulation, and reporting, while tools built on EnergyPlus can leverage the test simulation and reporting. The model generation is accomplished by running OpenStudio measures for envelope, heating, or cooling test cases. At this stage the specified weather file required for a specific test case is assigned to the model. Simulation is enabled using the OpenStudio Command Line Interface (CLI) to run a series of OpenStudio and Reporting measures to a specified seed model. The specified workflow is defined with an OpenStudio OSW file. The first measure generates the test case model, while the second measure is a reporting measure that runs after the simulation to collect necessary simulation results from the EnergyPlus SQL file. The Reporting stage gathers data from individual OpenStudio OSW files and populates a series of BESTEST Microsoft Excel spreadsheets. BESTEST-GSR also gathers zip files from individual simulations for diagnostic purposes.

Goldwasser, David↗

Update to the Microcontroller Benchmark for Radiation Testing

LANL developed a benchmark of software code for radiation testing of microprocessors several years ago, and it was published under an open-source license on GitHub. Publishing the software is necessary for other researchers to adopt and implement this benchmark for radiation testing of other microprocessors to standardize test practices so that test data can be compared across different microprocessors. The original codes have been used several times by other organizations to test a wide range of microcontrollers and microprocessors. After several years of research, LANL is ready to update the benchmark. Changes include: 1. Addition of new codes that allow common software codes to be tested, 2. Addition of new codes that instrument more microprocessor circuitry, 3. Addition of input patterns that allow for a more compressive understanding of how the memory layout affects the sensitivity to radiation-induced faults and better use of automated test pattern generation standards, and 4. Modification of current codes for faster and more resilient detection, reporting and correction of radiation-induced faults. These codes have been tested by LANL researchers over the last few years, which has been published in the open literature. As the code base for the new benchmarks are stable, it is time to release the update to the GitHub repository, where the original codes were released.

Quinn, Heather↗

In-situ thermomechanical measurements during burst testing of Zr claddings using digital image correlation and infrared thermography techniques

Burst testing has long been a relied-on method for assessing fuel cladding materials in light-water reactoraccident scenarios. However, burst testing historically provided minimal in-situ observations beyond a few thermocouple readings, pressure from transducers, and post-test deformation measurements. Acquisition of full cladding thermomechanical data throughout a burst test would be invaluable to fuel system qualification, material model development and fuel performance code validation, such as the BISON fuel performance code. Recently, methodologies for simultaneously applying 2-dimensional digital image correlation and infrared thermography techniques to quantify the relationship between temperature, internal cladding pressure, and deformation during burst testing were developed. This work details results from the application of these techniques to burst testing of Zircaloy-4 cladding segments subjected to loss-of-coolant accident transients in an air environment. Two types of tests were performed with: (a) cladding segments connected to a fixed pressure reservoir as well as (b) closed systems where internal pressure increased during transients. In-situ thermomechanical measurements including strain and thermal gradient data are presented, demonstrating the effectiveness of applying combined surface measurement techniques to burst testing

Bell, Sam↗

The Effect of Prostate-Specific Antigen (PSA) Test on Radiation Risk Estimate for Prostate Cancer Incidence among Atomic-Bomb Survivors

Following our previous report on the radiation doseresponse for prostate cancer incidence rates in the Life Span Study (LSS) cohort of atomic bomb survivors, we reevaluated the radiation-related risk adjusting for differences in baseline cancer incidence rates among three subsets of the LSS cohort defined by the timing of their first participation in biennial health examinations offered to the Adult Health Study (AHS) sub-cohort members and prostate-specificantigen (PSA) testing status for AHS participants: 1. nonAHS participants, 2. AHS participants before receiving PSA test, and 3. AHS participants after receiving PSA test. We found a 2.9-fold increase in the baseline incidence rates among AHS participants after receiving PSA test. After adjusting for the PSA-testing-status effects on the baseline rates the estimated excess relative risk (ERR) per Gy was 0.54 (95% CI: 0.15, 1.05), which was almost identical to the previously reported unadjusted ERR estimate (0.57, 95% CI: 0.21, 1.00). The current results confirmed that, while the PSA testing among AHS participants increased the baseline incidence rates, it did not impact the radiation risk estimate, strengthening the previously reported dose-response relationship for prostate cancer incidence in the LSS. As the use of PSA tests continue in screening and medical settings, analyses of possible effects of PSA testing should be an important aspect of future epidemiological studies of the association between radiation exposure and prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observed Surface Disturbances Associated with the DPRK’s 3 September 2017 Underground Nuclear Test

Satellite-based Synthetic Aperture Radar (SAR) data of the Punggye-ri nuclear test site, along with pre- and post-test optical commercial satellite imagery and a short official video (which was apparently recorded during the 3 September 2017 test), provide additional insights on the widespread surface disturbances around the peak of Mt. Mantap. These were generated by North Korea’s sixth and by far largest nuclear test (estimated to be roughly a quarter of a megaton; Zerbo, 2017). Although a number of visible landslides that are associated with this test had been previously reported, these additional data reveal more information about the widespread nature of the detected larger-scale movements that have been reported by other researchers, in addition to some smaller scale instances of localized slumping or compression within the top 200 m of the mountain; these took place in an area that was observed to contain stratified volcanic deposits not otherwise described to date. A closer look at two previously described zones of localized slippage, subsidence, or slumping (located within those identified volcanic layer deposits on the western side of Mt. Mantap) revealed useful information about the landscape of the area. Several healthy trees have been knocked down in one zone; in the other, a rock prominence had collapsed, and a 60-m-long crack or crevice appeared to have opened. It remains unclear whether these surface disturbances were associated with what had been allegedly reported by the news media as a “cave-in that was externally observable.” However, given the likely 800 m depth of the test in the lower hard-rock geology, we have been led to conclude that the notable observed localized surface disturbances cannot be interpreted as a “collapse crater” that was a result of a “cave-in” above any nuclear test created cavity and/or associated tunneling. Although the broadscale nature of the SAR and visually detected movements inhibits more precise geolocation of the test within the mountain, the radar imagery did show that the various surface ground movements were generated in opposing directions. The movements were directed away from the center on either side of the mountain; as such, they provided an empirical basis to confirm the previous seismological estimates that the detonation had occurred somewhere under the peak of Mt. Mantap. Moreover, a North Korean-sourced short video that was acquired with a ground-based camera focused directly on the peak shows a large dust cloud rising up from the mountain. In conclusion, this provides additional evidence that is consistent with that conclusion.

58 GEOSCIENCES↗

OECD MCCI project Melt Eruption Test (MET) design report, Rev. 2. April 15, 2003.

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. The Melt Coolability and Concrete Interaction (MCCI) program is pursuing separate effect tests to examine the viability of the melt coolability mechanisms identified as part of the MACE program. These mechanisms include bulk cooling, water ingression, volcanic eruptions, and crust breach. At the second PRG meeting held at ANL on 22-23 October 2002, a preliminary design1 for a separate effects test to investigate the melt eruption cooling mechanism was presented for PRG review. At this meeting, NUPEC made several recommendations on the experiment approach aimed at optimizing the chances of achieving a floating crust boundary condition in this test. The principal recommendation was to incorporate a mortar sidewall liner into the test design, since data from the COTELS experiment program indicates that corium does not form a strong mechanical bond with this material. Other recommendations included: (i) reduction of the electrode elevation to well below the melt upper surface elevation (since the crust may bond to these solid surfaces), and (ii) favorably taper the mortar liner to facilitate crust detachment and relocation during the experiment. Finally, as a precursor to implementing these modifications, the PRG recommended the development of a design for a small-scale scoping test intended to verify the ability of the mortar liner to preclude formation of an anchored bridge crust under core-concrete interaction conditions. This revised Melt Eruption Test (MET) plan is intended to satisfy these PRG recommendations. Specifically, the revised plan focuses on providing data on the extent of crust growth and melt eruptions as a function of gas sparging rate under well-controlled experiment conditions, including a floating crust boundary condition. The overall objective of MET is to determine to what extent core debris is rendered coolable by eruptive-type processes that breach the crust that rests upon the melt. The specific objectives of this test are as follows: (1) Evaluate the augmentation in surface heat flux during periods of melt eruption; (2) Evaluate the melt entrainment coefficient from the heat flux and gas flow rate data for input into models that calculate ex-vessel debris coolability; (3) Characterize the morphology and coolability of debris resulting from eruptive processes that transport melt into overlying water; and (4) Discriminate between periods when eruptions take the form of particle ejections into overlying water, leading to a porous particle bed, and single-phase extrusions, which lead to volcano-type structures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MMCI Small-Scale Water Ingression and Crust Strength tests (SSWICS) SSWICS-1 final data report, Rev. 1 February 10, 2003.; Report, Rev. 1

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure; and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx}{phi}30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the first water ingression test, designated SSWICS-1. The test investigated the quench behavior of a 15 cm deep, fully oxidized PWR corium melt containing 8 wt% limestone/common sand concrete decomposition products. The melt was quenched at nominally atmospheric pressure. The report includes a description of the test apparatus, the instrumentation used, plots of the recorded data, and data reduction to obtain an estimate of the corrected heat flux from the corium to the overlying water pool. A section of the report is devoted to calculations of the conduction-limited heat flux that accounts for heat losses to the crucible holding the corium. The remainder of the report describes post test examinations of the crust, which includes permeability and mechanical strength measurements, and chemical analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECM MCCI Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-2 final data report, Rev. 0 February 12, 2003.

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx}{phi}30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the second water ingression test, designated SSWICS-2. The test investigated the quench behavior of a 15 cm deep, fully oxidized PWR corium melt containing 8 wt% siliceous concrete decomposition products. The melt was quenched at nominally atmospheric pressure. The report includes a description of the test apparatus, the instrumentation used, plots of the recorded data, and data reduction to obtain an estimate of the corrected heat flux from the corium to the overlying water pool. A section of the report is devoted to calculations of the conduction-limited heat flux that accounts for heat losses to the crucible holding the corium. The remainder of the report describes post test examinations of the crust, which includes permeability and mechanical strength measurements, and chemical analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests are met for all configurations: one, two, or three fans (normal).

air sampling↗

Solid-State Fault Current Limiter Development: Design and Testing Update of a 15kV SSCL Power Stack

The Solid-State Fault Current Limiter (SSCL) is a promising technology that can be applied to utility power delivery systems to address the problem of increasing fault currents associated with load growth. As demand continues to grow, more power is added to utility system either by increasing generator capacity or by adding distributed generators, resulting in higher available fault currents, often beyond the capabilities of the present infrastructure. The SSCL is power-electronics based equipment designed to work with the present utility system to address this problem. The SSCL monitors the line current and dynamically inserts additional impedance into the line in the event of a fault being detected. The SSCL is based on a modular design and can be configured for 5kV through 69kV systems at nominal current ratings of 1000A to 4000A. Results and Findings This report provides the final test results on the development of 15kV class SSCL single phase power stack. The scope of work included the design of the modular standard building block sub-assemblies, the design and manufacture of the power stack and the testing of the power stack for the key functional tests of continuous current capability and fault current limiting action. Challenges and Objectives Solid-State Current Limiter technology impacts a wide spectrum of utility engineering and operating personnel. It addresses the problems associated with load growth both at Transmission and Distribution class networks. The design concept is pioneering in terms of developing the most efficient and compact power electronics equipment for utility use. The initial test results of the standard building blocks are promising. The independent laboratory tests of the power stack are promising. However the complete 3 phase system needs rigorous testing for performance and reliability. Applications, Values, and Use The SSCL is an intelligent power-electronics device which is modular in design and can provide current limiting or current interrupting capabilities. It can be applied to variety of applications from distribution class to transmission class power delivery grids and networks. It can also be applied to single major commercial and industrial loads and distributed generator supplies. The active switching of devices can be further utilized for protection of substation transformers. The stress on the system can be reduced substantially improving the life of the power system. It minimizes the voltage sag by speedy elimination of heavy fault currents and promises to be an important element of the utility power system. DOE Perspective This development effort is now focused on a 15kV system. This project will help mitigate the challenges of increasing available fault current. DOE has made a major contribution in providing a cost effective SSCL designed to integrate seamlessly into the Transmission and Distribution networks of today and the future. Approach SSCL development program for a 69kV SSCL was initiated which included the use of the Super GTO advanced semiconductor device which won the 2007 R&D100 Award. In the beginning, steps were identified to accomplish the economically viable design of a 69kV class Solid State Current Limiter that is extremely reliable, cost effective, and compact enough to be applied in urban transmission. The prime thrust in design and development was to encompass the 1000A and the 3000A ratings and provide a modular design to cover the wide range of applications. The focus of the project was then shifted to a 15kV class SSCL. The specifications for the 15kV power stack are reviewed. The design changes integrated into the 15kV power stack are discussed. In this Technical Update the complete project is summarized followed by a detailed test report. The power stack independent high voltage laboratory test requirements and results are presented. Keywords Solid State Current Limiter, SSCL, Fault Current Limiter, Fault Current Controller, Power electronics controller, Intelligent power-electronics Device, IED

24 POWER TRANSMISSION AND DISTRIBUTION↗

DUS II Soil Gas Sampling and Air Injection Test Results

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

54 ENVIRONMENTAL SCIENCES↗

Technetium Retention in WTP LAW Glass with Recycle Flow-Sheet: DMIO Melter Testing

Melter tests were conducted to determine the retention of technetium and other volatiles in glass while processing simulated Low Activity Waste (LAW) streams through a DM10 melter equipped with a prototypical off-gas system that concentrates and recycles fluid effluents back to the melter feed. To support these tests, an existing DM10 system installed at Vitreous State Laboratory (VSL) was modified to add the required recycle loop. Based on the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW off-gas system design, suitably scaled versions of the Submerged Bed Scrubber (SBS), Wet Electrostatic Precipitator (WESP), and TLP vacuum evaporator were designed, built, and installed into the DM10 system. Process modeling was used to support this design effort and to ensure that issues associated with the short half life of the 99m Tc radioisotope that was used in this work were properly addressed and that the system would be capable of meeting the test objectives. In particular, this required that the overall time constant for the system was sufficiently short that a reasonable approach to steady state could be achieved before the 99m Tc activity dropped below the analytical limits of detection. The conceptual design, detailed design, flow sheet development, process model development, Piping and Instrumentation Diagram (P&ID) development, control system design, software design and development, system fabrication, installation, procedure development, operator training, and Test Plan development for the new system were all conducted during this project. The new system was commissioned and subjected to a series of shake-down tests before embarking on the planned test program. Various system performance issues that arose during testing were addressed through a series of modifications in order to improve the performance and reliability of the system. The resulting system provided a robust and reliable platform to address the test objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of the Carbon Sequestration Potential of the Cambro-Ordovician Strata of the Illinois and Michigan Basins. Part 1. Evaluation of Phase 2 CO 2 Injection Testing in the Deep Saline Gunter Sandstone Reservoir (Cambro-Ordovician Knox Group), Marvin Blan No. 1 Hancock County, Kentucky Part 2. Time-lapse Three-Dimensional Vertical Seismic Profile (3D-VSP) of Sequestration Target Interval with Injected Fluids

Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO 2 in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO 2 storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO 2 were present in the deep subsurface. Injection testing with brine and CO 2 was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole – including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite – at 1152–2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO 2 was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter.

54 ENVIRONMENTAL SCIENCES↗

2010 Ford Fusion VIN 4757 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2010 Ford Fusion HEV (VIN: 3FADP0L34AR144757). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

25 ENERGY STORAGE↗

2010 Honda Insight VIN 0141 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H78AS010141). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

25 ENERGY STORAGE↗

2010 Honda Insight VIN 1748 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H59AS011748). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

25 ENERGY STORAGE↗

2010 Toyota Prius VIN 0462 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN: JTDKN3DU2A5010462). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

25 ENERGY STORAGE↗

2010 Toyota Prius VIN 6063 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN JTDKN3DU5A0006063). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

25 ENERGY STORAGE↗