SEARCH · Engineering Papers
Results for “system”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Weathering and erosion of fractured bedrock systems: Weathering and erosion of fractured bedrock systems
We explore the contribution of fractures (joints) in controlling the rate of weathering advance for a low-porosity rock by using methods of homogenization to create averaged weathering equations. The rate of advance of the weathering front can be expressed as the same rate observed in non-fractured media (or in an individual block) divided by the volume fraction of non-fractured blocks in the fractured parent material. In the model, the parent has fractures that are filled with a more porous material that contains only inert or completely weathered material. The low-porosity rock weathers by reaction-transport processes. As observed in field systems, the model shows that the weathering advance rate is greater for the fractured as compared to the analogous non-fractured system because the volume fraction of blocks is <1. The increase in advance rate is attributed both to the increase in weathered material that accompanies higher fracture density, and to the increase in exposure of surface of low-porosity rock to reaction-transport. For constant fracture aperture, the weathering advance rate increases when the fracture spacing decreases. Equations describing weathering advance rate are summarized in the “List of selected equations”. If erosion is imposed at a constant rate, the weathering systems with fracture-bounded bedrock blocks attain a steady state. In the erosional transport-limited regime, bedrock blocks no longer emerge at the air-regolith boundary because they weather away. In the weathering-limited (or kinetic) regime, blocks of various size become exhumed at the surface and the average size of these exposed blocks increases with the erosion rate. For convex hillslopes, the block size exposed at the surface increases downslope. This model can explain observations of exhumed rocks weathering in the Luquillo mountains of Puerto Rico.
Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems
Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.
Weakly nonlinear dynamics in noncanonical Hamiltonian systems with applications to fluids and plasmas
A method, called beatification, is presented for rapidly extracting weakly nonlinear Hamiltonian systems that describe the dynamics near equilibria of systems possessing Hamiltonian form in terms of noncanonical Poisson brackets. The procedure applies to systems like fluids and plasmas in terms of Eulerian variables that have such noncanonical Poisson brackets, i.e., brackets with nonstandard and possibly degenerate form. A collection of examples of both finite and infinite dimensions is presented.
A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System
Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.
Bioaerosols in the Earth system: Climate, health, and ecosystem interactions
Aerosols of biological origin play a vital role in the Earth system, particularly in the in-teractions between atmosphere, biosphere, climate, and public health. Airborne bacteria, fungal spores, pollen, and other bioparticles are essential for the reproduction and spread of organisms across various ecosystems, and they can cause or enhance human, animal, and plant diseases. Moreover, they can serve as nuclei for cloud droplets, ice crystals, and precipitation, thus influencing the hydrological cycle and climate. The actual formation, abundance, composition, and effects of biological aerosols and the atmospheric microbi-ome are, however, not yet well characterized and constitute a large gap in the scientific understanding of the interaction and co-evolution of life and climate in the Earth system. This review presents an overview of the state of bioaerosol research and highlights recent advances in terms of bioaerosol identification, characterization, transport, and transfor-mation processes, as well as their interactions with climate, health, and ecosystems, focus-ing on the role bioaerosols play in the Earth system.
Evaluation of experimentally measured and model-calculated pH for rock-brine-CO2 systems under geologic CO2 sequestration conditions
pH is an essential parameter for understanding the geochemical reactions that occur in rock-brine-CO2 systems when CO2 is injected into deep geologic formations for long-term storage. Due to a lack of reliable experimental methods, most laboratory studies conducted under geological CO2 sequestration (GCS) conditions have relied on thermodynamic modeling to estimate pH. The accuracy of these model predictions is typically uncertain. In our previous work, we have developed a method for pH determination by in-situ spectrophotometry. In the present work, we expanded the applicable pH range for this method and measured the pH of several rock-brine-CO2 systems at GCS conditions for five rock samples collected from ongoing GCS demonstration projects. Experimental measurements were compared with pH values calculated using several geochemical modeling approaches. The effect of different thermodynamic databases on the accuracy of model prediction was evaluated. Results indicate that the accuracy of model calculations is rock-dependent. For rocks comprised of carbonate and sandstone, model results generally agreed well with experimentally measured pH; however, for basalt, significant differences were observed. These discrepancies may be due to the models’ failure to fully account for certain reaction occurring between the basalt minerals the CO2-saturated brine solutions.
System design of a 1 MW north-facing, solid particle receiver
Falling solid particle receivers (SPR) utilize small particles as a heat collecting medium within a cavity receiver structure. The components required to operate an SPR include the receiver (to heat the particles), bottom hopper (to catch the falling particles), particle lift elevator (to lift particles back to the top of the receiver), top hopper (to store particles before being dropped through the receiver), and ducting. In addition to the required components, there are additional features needed for an experimental system. These features include: a support structure to house all components, calibration panel to measure incident radiation, cooling loops, and sensors (flux gages, thermocouples, pressure gages). Each of these components had to be designed to withstand temperatures ranging from ambient to 700 °C. Thermal stresses from thermal expansion become a key factor in these types of high temperature systems. The SPR will be housing ~3000 kg of solid particles. The final system will be tested at the National Solar Thermal Test Facility in Albuquerque, NM.
Validation on Aggregate Flexibility from Residential Air Conditioning Systems for Building-to-Grid Integration
To facilitate the integration of buildings to the power grid, battery-equivalent models have been proposed to characterize and quantify aggregate flexibility from building loads. An analytical method has been proposed to construct such a flexibility model for thermostatically controlled loads. Since this analytical method is derived from a simplified representation of building thermal dynamics, it is necessary to evaluate the resulting flexibility model in a more realistic context. This paper focuses on the validation of this analytical method for estimating aggregate flexibility from residential air conditioning (ACs) systems. A high-fidelity model is first developed to mimic thermal behaviors of a residential AC system through a co-simulation between Modelica and EnergyPlus. A population of virtual residential AC systems is then generated by randomizing parameters of the high-fidelity model. Finally, an aggregate flexibility model is constructed for the residential AC population using the analytical method and validated using results from simulation of the high-fidelity model. It is found that the flexibility estimated using the analytical method is with reasonable accuracy, but can be improved by explicitly incorporating heat gains into the method.
Fast robust power system dynamic state estimation using model transformation
Not Available
Sorbent Material Property Requirements for On-Board Hydrogen Storage for Automotive Fuel Cell Systems.
Material properties required for on-board hydrogen storage in cryogenic sorbents for use with automotive polymer electrolyte membrane (PEM) fuel cell systems are discussed. Models are formulated for physical, thermodynamic and transport properties, and for the dynamics of H-2 refueling and discharge from a sorbent bed. A conceptual storage configuration with in-bed heat exchanger tubes, a Type-3 containment vessel, vacuum insulation and requisite balance-of-plant components is developed to determine the peak excess sorption capacity and differential enthalpy of adsorption for 5.5 wt% system gravimetric capacity and 55% well-to-tank (WTT) efficiency. The analysis also determines the bulk density to which the material must be compacted for the storage system to reach 40 g.L-1 volumetric capacity. Thermal transport properties and heat transfer enhancement methods are analyzed to estimate the material thermal conductivity needed to achieve 1.5 kg.min(-1) H-2 refueling rate. Operating temperatures and pressures are determined for 55% WTT efficiency and 95% usable H-2. Needs for further improvements in material properties are analyzed that would allow reduction of storage pressure to 50 bar from 100 bar, elevation of storage temperature to 175-200 K from 150 K, and increase of WTT efficiency to 57.5% or higher.
Measurement of the oxygen partial pressure and thermodynamic modeling of the U–Nd–O system
Not Available
Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings
System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear
Assessing laser powder bed fusion system geometric errors through artifact-based methods
Additive manufacturing (AM) machines have developed more rapidly than standardized frameworks needed for the qualification of their geometric capabilities. While some manufacturer-specific methods exist to test capabilities and perform some calibration tasks, standardization efforts have only recently been undertaken in the form of ISO/ASTM 52902. In this study, the recommended methodology prescribed by the standard was implemented by building geometric artifacts with a laser powder bed fusion (LPBF) system and performing dimensional inspection with a coordinate measurement machine (CMM), amongst other methods. Typical dimensional capabilities of the LPBF system are identified and commentary is made on applying metrology methods, detecting geometric error, and diagnosing base causes in the LPBF system. In doing so, favored metrology practices and measurement analysis methods auxiliary to the standard are proposed. Artifact measurements were used to characterize beam positioning error and beam offset error. Methods for decoupling the effects of error sources are proposed. Difficulties in the inspection of AM components are identified, and the effects of various CMM measurement strategies are evaluated. Insights on the application of the new standard are presented, along with commentary as to its fitness for the LPBF process.
Comparative evaluation of deep learning workloads for leadership-class systems
Deep learning (DL) workloads and their performance at scale are becoming important factors to consider as we design, develop and deploy next-generation high-performance computing systems. Since DL applications rely heavily on DL frameworks and underlying compute (CPU/GPU) stacks, it is essential to gain a holistic understanding from compute kernels, models, and frameworks of popular DL stacks, and to assess their impact on science-driven, mission-critical applications. At Oak Ridge Leadership Computing Facility (OLCF), we employ a set of micro and macro DL benchmarks established through the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) to evaluate the AI readiness of our next-generation supercomputers. In this paper, we present our early observations and performance benchmark comparisons between the Nvidia V100 based Summit system with its CUDA stack and an AMD MI100 based testbed system with its ROCm stack. We take a layered perspective on DL benchmarking and point to opportunities for future optimizations in the technologies that we consider.