Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

In-Situ Characterization of Cloud Condensation Nuclei, Interstitial, and background Particles using Single Particle Mass Spectrometer, SPLAT II

Aerosol indirect effect remains the most uncertain aspect of climate change modeling because proper test requires knowledge of individual particles sizes and compositions with high spatial and temporal resolution. We present the first deployment of a single particle mass spectrometer (SPLAT II) that is operated in a dual data acquisition mode to measure all the required individual particle properties with sufficient temporal resolution to definitively resolve the aerosol-cloud interaction in this exemplary case. We measured particle number concentrations, asphericity, and individual particle size, composition, and density with better than 60 seconds resolution. SPLAT II measured particle number concentrations between 70 particles cm-3and 300 particles cm-3, an average particle density of 1.4 g cm-3. Found that most particles are composed of oxygenated organics, many of which are mixed with sulfates. Biomass burn particles some with sulfates were prevalent, particularly at higher altitudes, and processed sea-salt was observed over the ocean. Analysis of cloud residuals shows that with time cloud droplets acquire sulfate by the reaction of peroxide with SO2. Based on the particle mass spectra and densities we find that the compositions of cloud condensation nuclei are similar to those of background aerosol but, contain on average ~7% more sulfate, and do not include dust and metallic particles. A comparison between the size distributions of background, activated, and interstitial particles shows that while nearly none of the activated particles is smaller than 115 nm, more than 80% of interstitial particles are smaller than 115 nm. We conclude that for this cloud the most important difference between CCN and background aerosol is particle size although having more sulfate also helps.

54 ENVIRONMENTAL SCIENCES↗

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser. Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed Multiple Reaction Monitoring Approach to Enhancing Sensitivity of a Tandem Quadrupole Mass Spectrometer

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trap (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Application of Machine Learning Techniques for Rapid Source Apportionment of Aerosol Mass Spectrometer Datasets

In this work, we apply machine learning approaches sparse multinomial logistic regression to classify aerosol mass spectrometer (AMS) unit mass resolution (UMR) data followed by an ensemble regression technique for source apportionment of organic aerosols (OA). The classifier was trained on 60 well characterized laboratory and positive matrix factorization (PMF) deconvolved reference spectra to identify eight OA types. These include four laboratory-derived secondary organic aerosol (SOA) spectra, which include isoprene photooxidation SOA, isoprene epoxydiols (IEPOX) SOA, a monoterpene SOA type that includes a-pinene and ß-pinene SOA, and aromatic SOA from oxidation of naphthalene and m-xylene precursors, as well as PMF deconvolved spectra for three primary organic aerosol (POA) types, namely, hydrocarbon-like organic aerosol (HOA), biomass burning organic aerosol (BBOA), and cooking OA (COA), and a more oxidized oxygenated OA type (MO-OOA). A 5-fold cross-validation strategy, repeated 10 times, was used to assess the classifier’s performance. The classifier had high classification accuracy for COA, aromatic SOA, and isoprene SOA spectra but incorrectly classified ~9% by number of MO-OOA spectra as BBOA, 12% of BBOA spectra as HOA (and vice versa), and 18% of IEPOX-SOA spectra as aromatic SOA. Next, an ensemble regression model was trained on an artificially generated dataset consisting of mixtures of different OA types to assess its ability to predict fractional mass abundances from classification probabilities of various OA species obtained from the multinomial logistic regression classifier trained on the reference spectra. Ultimately, the proposed approach was applied for source apportionment of aircraft-based AMS measurements of OA UMR spectra during the HI-SCALE field campaign. On two representative days (May 6th and 18th, 2016), the algorithm determined that ~50-60% of OA by mass was MO-OOA, which represented a highly aged organic aerosol mixture from different sources. On both days, BBOA was determined to contribute less than 10% to OA by mass. However, on May 18th, the aromatic SOA fraction was higher compared to that on May 6th. The proposed approach is capable of rapidly analyzing AMS data in real time, making it suitable for applications where rapid source apportionment of AMS OA spectra is desirable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast In Situ Airborne Measurement of Ammonia Using a Mid-Infrared Off-Axis ICOS Spectrometer

A new ammonia (NH 3 ) analyzer was developed based on off-axis integrated cavity output spectroscopy. Its feasibility was demonstrated by making tropospheric measurements in flights aboard the Department of Energy Gulfstream-1 aircraft. The ammonia analyzer consists of an optical cell, quantum-cascade laser, gas sampling system, control and data acquisition electronics, and analysis software. The NH 3 mixing ratio is determined from high-resolution absorption spectra obtained by tuning the laser wavelength over the NH 3 fundamental vibration band near 9.67 μm. Excellent linearity is obtained over a wide dynamic range (0–101 ppb v ) with a response rate (1/e) of 2 Hz and a precision of ±90 ppt v (1σ in 1 s). Two research flights were conducted over the Yakima Valley in Washington State. In the first flight, the ammonia analyzer was used to identify signatures of livestock from local dairy farms with high vertical and spatial resolution under low wind and calm atmospheric conditions. In the second flight, the analyzer captured livestock emission signals under windy conditions. Finally, our results demonstrate that this new ammonia spectrometer is capable of providing fast, precise, and accurate in situ observations of ammonia aboard airborne platforms to advance our understanding of atmospheric compositions and aerosol formation.

airborne↗

"Depth-Profiling" and Quantitative Characterization of the Size, Composition, Shape, Density, and Morphology of Fine Particles with SPLAT, a Single-Particle Mass Spectrometer

A significant fraction of atmospheric particles are composed of inorganic substances that are mixed or coated with organics. The behavior of these particles depends on the particle internal composition and on the arrangement of the specific constituents in each particle. It is important to know which constituent is on the surface and whether it entirely covers the particle surface. We present a study that demonstrates that an instrumental system that includes an ultra-sensitive single particle mass spectrometer that is coupled with a differential mobility analyzer can be used to quantitatively measure in real-time individual particle composition, size, density, shape and determine which substance is on the surface and whether it entirely covers the particle. Here we use liquid dioctyl phthalate to coat NaCl seeds and generate spherical particles that are encapsulated with the organic coat and pyrene, a solid poly aromatic hydrocarbon, to produce aspherical particles with pyrene nodules and exposed NaCl cores. We show that the behavior of the mass spectral intensities as a function of laser fluence yields information that can be used to determine the morphological distribution of individual particles constituents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity Upgrades to the Idaho Accelerator Center Neutron Time of Flight Spectrometer

Past experiments have shown that discrimination between between fissionable and non-fissionable materials is possible using an interrogation technique that monitors for high energy prompt fission neutrons. Several recent upgrades have been made to the neutron time of flight spectrometer at the Idaho Accelerator Center with the intent of increasing neutron detection sensitivity, allowing for system use in nonproliferation and security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact soft x-ray spectrometer for plasma diagnostics at the Heidelberg Electron Beam Ion Trap

A compact flat-field soft x-ray grazing-incidence grating spectrometer equipped with a cryogenically cooled back-illuminated charge-coupled device camera was built and implemented at the Heidelberg Electron Beam Ion Trap. The instrument spans the spectral region from 1 to 37 nm using two different gratings. In slitless operation mode, it directly images a radiation source, in this case ions confined in an electron beam ion trap, with high efficiency and reaching hereby a resolving power of {lambda}/{delta}{lambda} congruent with 130 at 2 nm and of {lambda}/{delta}{lambda} congruent with 600 at 28 nm. Capable of automatized operation, its low noise and excellent stability make it an ideal instrument not only for spectroscopic diagnostics requiring wide spectral coverage but also for precision wavelength measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable x-ray fluorescence spectrometer for coating thickness measurement

A handheld x-ray spectrometer has been realized and tested. The purpose of the device is to measure the thickness of coated samples in the range of 1-1500 nm in an industrial environment. Accuracy of {approx}3% has been achieved in this range with a measurement time of 1 min. Automated software has been implemented to allow utilization by a nonspecialist operator. An automated calibration procedure, based on measurements of reference samples, is used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A homemade high-resolution orthogonal-injection time-of-flight mass spectrometer with a heated capillary inlet

We describe a homemade high-resolution orthogonal-injection time-of-flight (O-TOF) mass spectrometer combing a heated capillary inlet. The O-TOF uses a heated capillary tube combined with a radio-frequency only quadrupole (rf-only quadrupole) as an interface to help the ion transmission from the atmospheric pressure to the low-pressure regions. The principle, configuration of the O-TOF, and the performance of the instrument are introduced in this paper. With electrospray ion source, the performances of the mass resolution, the sensitivity, the mass range, and the mass accuracy are described. We also include our results obtained by coupling atmospheric pressure matrix-assisted laser deporption ionization with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave-dispersive x-ray spectrometer for simultaneous acquisition of several characteristic lines based on strongly and accurately shaped Ge crystal

Si and Ge are widely used as analyzing crystals for x-rays. Drastic and accurate shaping of Si or Ge gives significant advance in the x-ray field, although covalently bonded Si or Ge crystals have long been believed to be not deformable to various shapes. Recently, we developed a deformation technique for obtaining strongly and accurately shaped Si or Ge wafers of high crystal quality, and the use of the deformed wafer made it possible to produce fine-focused x-rays. In the present study, we prepared a cylindrical Ge wafer with a radius of curvature of 50 mm, and acquired fluorescent x-rays simultaneously from four elements by combining the cylindrical Ge wafer with a position-sensitive detector. The energy resolution of the x-ray fluorescence spectrum was as good as that obtained using a flat single crystal, and its gain was over 100. The demonstration of the simultaneous acquisition of high-resolution x-ray fluorescence spectra indicated various possibilities of x-ray spectrometry, such as one-shot x-ray spectroscopy and highly efficient wave-dispersive x-ray spectrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a tomographic hard X-ray spectrometer for suprathermal electron studies with ECRH

Electron cyclotron resonance heating (ECRH) and current drive (ECCD), disruptive instability events and sawtooth activity have been demonstrated to produce suprathermal electrons in fusion devices. The importance of these phenomena for fusion reactors renders suprathermal electron generation and dynamics a key topic in the physics of burning plasmas. Here some significant results from the TCV tokamak are briefly reviewed and a preliminary design of a novel tomographic hard X-ray spectrometer proposed for TCV is discussed. The design is aided by simulations of tomographic reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic evaluation of three different gratings used for a flat-field extreme ultraviolet spectrometer to monitor {delta}n=1 transitions from medium-Z impurities in 10-30 A

Spectral characteristics of varied line spacing 2400 grooves/mm gratings used for a flat-field extreme ultraviolet spectrometer have been evaluated to monitor {delta}n=1 (n=2-3) transitions from medium-Z impurities in 10-30 A, where many spectral lines from metallic impurities closely exist. For this purpose emission spectra of the {delta}n=1 transitions from partially L-shell-ionized Ti and Fe have been measured in large helical device. At first, a ruled and a holographic grating were utilized for the comparative study. Both gratings suppressed higher order light effectively but spectral sensitivity was much higher for the holographic grating. The ruled grating, however, attained better spectral resolution (0.083 A at 18.97 A) in the 10-100 A range compared to that (0.130 A) of the holographic grating. After that a recently developed new holographic grating with different laminar shapes and line spacings has attempted to improve the spectral resolution. As a result, it has considerably improved the spectral resolution in the 10-30 A range, i.e., {approx}0.090 A. However, it is found that the experimentally obtained spectral resolution is quit poor compared to the computationally simulated one, suggesting a technical difficulty in manufacturing exactly the varied line spacing of the holographic grating at such a short wavelength range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron spectrometer for ITER using silicon detectors

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency. Using annular silicon detectors, it is possible to greatly increase the solid angle coverage and hence improve efficiency. Based on a simulation (MCNPX) study, the scaling of energy resolution, efficiency, and time to determine an ion temperature to 10% accuracy on foil thickness and detector location is shown. The latter quantity is used to determine the optimum foil thickness and detector geometry for specific plasma temperatures. For a 20 keV deuterium-tritium (DT) plasma, 5.3% resolution with efficiency of 2.9x10{sup -4} n cm{sup 2} is attainable using the available detectors. This gives a temperature measurement with 10% accuracy in 1.1 ms for a neutron flux of 2x10{sup 9} n cm{sup -2}. Multiple detectors can be used to further increase the efficiency if needed. A system of this kind could be tested in a future DT campaign at, for example, JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy calibration of a high-resolution inelastic x-ray scattering spectrometer

The energy scale of a triple-axis x-ray spectrometer with meV energy resolution based on perfect silicon crystal optics is calibrated, utilizing the most recent determination of the silicon lattice parameter and its thermal expansion coefficient and recording the dispersion of longitudinal acoustic and optical phonons in a diamond single crystal and the molecular vibration mode in liquid nitrogen. Comparison of the x-ray results with previous inelastic neutron and Raman scattering results as well as with ab initio phonon dispersion calculations yields an overall agreement better than 2%.

36 MATERIALS SCIENCE↗