Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Hydrodynamic Analysis of a Suspended Cylinder Under Regular Wave Loading Based on Computational Fluid Dynamics: Preprint

An investigation into the computation of hydrodynamic loads on a suspended cylinder in regular waves is presented. The primary goal was to perform a three-way-validation of the loads between experimental measurements and simulations from two computational methods. Experimental measurements of the longitudinal inline force on a cylinder suspended at a fixed po- sition were available from the Offshore Code Comparison Col- laboration, Continued, with Correlation (OC5) project, Phase Ia. These measurements were compared to Computational Fluid Dynamics (CFD) simulations based on the solution of Reynolds- averaged Navier-Stokes (RANS) equations, as implemented in STAR-CCM plus. The study encompassed a sensitivity analysis of the loads computed in STAR-CCM plus based on wave modeling, boundary conditions, turbulence modeling, and spatial and tem- poral discretization. The analysis was supplemented by results generated with the offshore wind turbine engineering software OpenFAST, based on a hybrid combination of second-order po- tential flow and viscous drag fromMorison's equation. The focus of the investigation was on the assessment of the accuracy of the computation of first- and higher-order hydrodynamic loads. Sub- stantial differences were observed in the numerical prediction of the second and third harmonic force contribution. Local flow field analysis with CFD was applied to study the physics of wave run-up and diffraction dynamics to identify the causes.

16 TIDAL AND WAVE POWER↗

SU-C-BRB-03: Cross-Institutional Validation of An Ultrafast Automatic Planning Platform for Breast Irradiation

Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-10: Comparison of Dose Deformable Accumulation by Using Parallel and Serial Approaches

Purpose: The uncertainty of dose accumulation over multiple CT datasets with deformable fusion may have significant impact on clinical decisions. In this study, we investigate the difference of two dose summation approaches involving deformable fusion. Methods: Five patients, four external beam and one brachytherapy(BT), were chosen for the study. The BT patient was treated with CT-based HDR. The CT image sets acquired in the imageguidance process (8-11 CTs/patient) were used to determine the dose delivered to the four external beam patients. (prostate, pelvis, lung and head and neck). For the HDR patient (cervix), five CT image sets and the corresponding BT plans were used. In total 44 CT datasets and RT dose/plans were imported into the image fusion software MiM (6.0.4) for analysis.For each of the five clinical cases, the dose from each fraction was accumulated into the primary CT dataset by using both Parallel and Serial approaches. The dose-volume histogram (DVH) for CTV and selected organs-at-risks (OAR) were generated. The D95(CTV), OAR(mean) and OAR(max) for the four external beam cases the D90(CTV), and the max dose to bladder and rectum for the BT case were compared. Results: For the four external beam patients, the difference in D95(CTV) were <1.2% PD between the parallel and the serial approaches. The differences of the OAR(mean) and the OAR(max ) range from 0 to 3.7% and <1% PD respectively. For the HDR patient, the dose difference for D90 is 11% PD while that of the max dose to bladder and rectum were 11.5% and 23.3% respectively. Conclusion: For external beam treatments, the parallel and serial approaches have <5% difference probably because tumor volume and OAR have less changes from fraction to fraction. For the brachytherapy case, >10% dose difference between the two approaches was observed as significant volume changes of tumor and OAR were observed among treatment fractions.

60 APPLIED LIFE SCIENCES↗

Computational capacity in hydrodynamic real-time hybrid simulation applied to simulate the dynamic response of floating offshore wind turbines

Real-time hybrid simulation (RTHS) mitigates similitude distortions in model-scale tests of floating offshore wind turbines (FOWTs) by coupling physical experiments with numerical models in real time. The coupling requires faster-than-real-time numerical computations to satisfy temporal similitude with the physical experiment, presenting a bottleneck for using more complex numerical models in RTHS. This paper presents a hydrodynamic-RTHS (hydro-RTHS) framework for FOWTs that simulates the hydrodynamics physically and the aerodynamics numerically with sensor feedback from the physical testing. The framework adapts the three-loop hardware architecture to leverage greater computational resources and mitigate strict temporal requirements, enabling more computationally demanding numerical analyses in hydro-RTHS. The three-loop hardware architecture integrates multiple machines, each dedicated to either numerical analysis or RTHS controls, with a rate-transition algorithm to synchronize the tasks executed across the different machine processors. Virtual and physical tests verified and validated the hydro-RTHS framework, respectively. The ”virtual” tests, which approximates the physical domain numerically, verified the RTHS framework with respect to a numerical full-scale complete FOWT model simulated in the open-source software, OpenFAST. The virtual tests were able to maintain comparable control signals while enabling greater computational resources for the numerical calculations. Real-world physical tests demonstrated that the hydro-RTHS framework computes aerodynamic forces similar to the complete OpenFAST model, validating the hydro-RTHS framework using the three-loop hardware architecture. Findings show that the hydro-RTHS framework with the three-loop hardware architecture is computationally efficient, with reserve capacity to simulate more complex problems due to the customized software, hardware, and rate-transition algorithm.

17 WIND ENERGY↗

Deepmod: An Over-the-Air Trainable Machine Modem for Resilient PHY Layer Communications

Traditional physical layer protocols (e.g. WiFi, WiMax, etc.) are well established and are often optimal in a wide variety of channel conditions including heterogenous links and in tactical communications. Unfortunately, this same optimality encourages ubiquity in wireless communication technology and enhances the potential for catastrophic cyber or physical attacks due to prolific knowledge of underlying physical layers. Any truly resilient communications protocol must be capable of immediate redeployment to meet quality of service (QoS) demands in a wide variety of possible channel media. This work proposes an approach to communications that is contrary to much traditional approaches in that processing blocks are generated real-time and only relevant to the particular channel medium being used. Rather than creating man-made ubiquitous blocks of signal processing, we examine using processing that is immediately expendable once it has been used. This is achieved through software-defined radios, and deep modulation, where system blocks are replaced with machine learning graphs that can be trained, used, and then discarded as needed. Simulation and experimental hardware show how deep modulation can converge to viable communications links, using the same machine intelligence, in vastly different channels.

Anderson, Adam L↗

SU-E-J-265: Feasibility Study of Texture Analysis for Prognosis of Local Tumor Recurrence Within 5-Years for Pharyngeal-Laryngeal Carcinoma Patients Received Radiotherapy Treatment

Purpose: Pharyngeal and laryngeal carcinomas (PLC) are among the top leading cancers in Asian populations. Typically the tumor may recur and progress in a short period of time if radiotherapy fails to deliver a successful treatment. Here we used image texture features extracted from images of computed tomography (CT) planning and conducted a retrospective study to evaluate whether texture analysis is a feasible approach to predict local tumor recurrence for PLC patients received radiotherapy treatment. Methods: CT planning images of 100 patients with PLC treated by radiotherapy at our facility between 2001 and 2010 are collected. These patients were received two separate CT scans, before and mid-course of the treatment delivery. Before the radiotherapy, a CT scanning was used for the first treatment planning. A total of 30 fractions were used in the treatment and patients were scanned with a second CT around the end of the fifteenth delivery for an adaptive treatment planning. Only patients who were treated with intensity modulated radiation therapy and RapidArc were selected. Treatment planning software of Eclipse was used. The changes of texture parameters between two CT acquisitions were computed to determine whether they were correlated to the local tumor recurrence. The following texture parameters were used in the preliminary assessment: mean, variance, standard deviation, skewness, kurtosis, energy, entropy, inverse difference moment, cluster shade, inertia, cluster prominence, gray-level co-occurrence matrix, and gray-level run-length matrix. The study was reviewed and approved by the committee of our institutional review board. Results: Our calculations suggested the following texture parameters were correlated with the local tumor recurrence: skewness, kurtosis, entropy, and inertia (p<0.0.05). Conclusion: The preliminary results were positive. However some works remain crucial to be completed, including addition of texture parameters for different image features, sensitivity of tumor segmentation variations, and effect of image filtering.

60 APPLIED LIFE SCIENCES↗

SU-E-T-61: A Practical Process for Fabricating Passive Scatter Proton Beam Modulation Compensation Filters Using 3D Printing

Purpose: The purpose of this project was to devise a practical fabrication process for passive scatter proton beam compensation filters (CF) that is competitive in time, cost and effort using 3D printing. Methods: DICOM compensator filter files for a proton beam were generated by our Eclipse (Varian, Inc.) treatment planning system. The compensator thickness specifications were extracted with in-house software written in Matlab (MathWorks, Inc.) code and written to a text file which could be read by the Rhinoceros 5, computer-aided design (CAD) package (Robert McNeel and Associates), which subsequently generated a smoothed model in a STereoLithographic also known as a Standard Tesselation Language file (STL). The model in the STL file was subsequently refined using Netfabb software and then converted to printing instructions using Cura. version 15.02.1. for our 3D printer. The Airwolf3D, model HD2x, fused filament fabrication (FFF) 3D printer (Airwolf3D.com) was used for our fabrication system with a print speed of 150mm per second. It can print in over 22 different plastic filament materials in a build volume of 11” x 8” x 12”. We choose ABS plastic to print the 3D model of the imprint for our CFs. Results: Prints of the CF could be performed at a print speed of 70mm per second. The time to print the 3D topology for the CF for the 14 cm diameter snout of our Mevion 250 proton accelerator was less than 3 hours. The printed model is intended to subsequently be used as a mold to imprint a molten wax cylindrical to form the compensation after cooling. The whole process should be performed for a typical 3 beam treatment plan within a day. Conclusion: Use of 3D printing is practical and can be used to print a 3D model of a CF within a few hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-534: Level of Residual Radioactivity of Activated Parts of a Decommissioned Cyclotron

Purpose: CTI cyclotron RDS-111 was used at the Hong Kong Sanatorium and Hospital (HKSH) to produce radiopharmaceuticals and radioactive tracers for diagnostic scans between 1999 and 2007. During the operation, some machine components became radioactive by activation. For the safety of staff, decommissioning took place in 2009, two years after the cyclotron had stopped operation. This study investigates the residual radioactivity and radionuclides found in different cyclotron components in 2014 in compliance with the local regulations in Hong Kong for transfer of radioactive waste. Methods: A representative sample of each part was counted using a high-purity germanium detector (manufacturer: ORTECT) for at least four hours. GammaVision, a multichannel analyzer software, was used to identify the radionuclides found in the cyclotron components, as well as the associated activities. A standard library and a Mariscotti peak search algorithm were used to identify the present radionuclides. Only radionuclides with half-life greater than 180 days were considered. Results: Among the components, the Havar target foil has the highest specific activity ((4.6±0.6)×10{sup 2} Bq/g), with Co-60 being the most prominent ((3.8±0.5)×10{sup 2} Bq/g). The total activity of the target foil, however, is still low due to its small mass of 0.04 g. Radioisotopes Mn-54 (46±6 Bq/g), Na-22 (6.8±0.8 Bq/g), Co-57 (7.3±0.9 Bq/g), and Fe-59 (6.0±0.9 Bq/g) have also been detected in the target foil. The target window holder and the vacuum window register a specific activity of 88.3±0.6 Bq/g and 48.6±0.1 Bq/g, respectively. Other components, such as the collimator, the target tube, the valve body and the beamline, are also found with trace amounts of radionuclides. Conclusion: Even seven years after the cyclotron had stopped operation, some components still exhibited residual radioactivity from activation exceeding the IAEA clearance levels. Special consideration for radiological protection may need to be taken in the disposal of the cyclotron parts.

07 ISOTOPE AND RADIATION SOURCES↗

Solar Field Layout and Aimpoint Strategy Optimization

The existing methods that determine heliostat aiming strategies for concentrating solar power (CSP) central receiver plants typically use heuristics and/or are computationally expensive, and they lack flexibility for different desired flux profiles and receiver geometries. Because of the interaction between layout and aimpoint strategy, considering the former without accounting for the latter may yield solutions with superfluous heliostats that cannot be used efficiently without compromising receiver flux constraints. To that end, we develop a software decision tool that uses innovative optimization methods to both optimize aimpoint strategies and improve candidate layouts for the solar collection field of a CSP central receiver plant. A CSP plant’s effectiveness relies on the optical efficiency of the solar field, which may be limited by losses due to (i) the cosine effect, (ii) atmospheric attenuation, (iii) interference (i.e., shading and blocking) between heliostats, (iv) spillage as a result of heliostat positioning and geometry, and (iv) some heliostats’ inability to direct irradiance to the receiver without damage due to excessive thermal flux. The goal of this work is to obtain optimized aiming strategies and improved solar field layouts that reduce capital cost and increase field optical efficiency and utilization, while meeting the power requirements of a given CSP receiver design. We formulate the aimpoint optimization problem as a mixed-integer linear programming model, which we then decompose into submodels that we solve in parallel. The decomposition subdivides the solar field into sections, and aimpoint strategies for each section are obtained independently of the others. To improve existing layouts, we develop a utilization-weighted efficiency metric that we use to relocate heliostats to sections of the solar field with similar efficiency and higher utilization. Finally, to connect our software to high-fidelity flux models, we develop a Python application programming interface for SolarPILOT, a mature software package that characterizes solar field performance and generates the heliostat layouts and flux maps that serve as input to our models.

14 SOLAR ENERGY↗

Deployable Wind-Hybrid Power Systems for Defense and Disaster Response Applications

This report presents an analysis of the performance of deployable energy systems comprised of wind energy systems integrated with diesel generators, photovoltaic systems, and battery storage to meet the load requirements of a representative U.S. Army forward operating base. The analysis is conducted using HOMER, a microgrid analysis software that can search through a wide range of parameters to design and optimize microgrid power systems. The search parameters include the system architecture, the wind and solar resources, and the availability of diesel fuel. The results of the analysis measure the relative performance of the different systems and environments in terms of the overall transportation cost to deploy the system and the ability to provide resilience in terms of meeting mission critical loads.

02 PETROLEUM↗

The Locus Algorithm IV: Performance metrics of a grid computing system used to create catalogues of optimised pointings

This paper discusses the requirements for and performance metrics of the the Grid Computing system used to implement the Locus Algorithm to identify optimum pointings for differential photometry of 61,662,376 stars and 23,779 quasars. Initial operational tests indicated a need for a software system to analyse the data and a High Performance Computing system to run that software in a scalable manner. Practical assessments of the performance of the software in a serial computing environment were used to provide a benchmark against which the performance metrics of the HPC solution could be compared, as well as to indicate any bottlenecks in performance. These performance metrics indicated a distinct split in the performance dictated more by differences in the input data than by differences in the design of the systems used. This indicates a need for experimental analysis of system performance, and suggests that algorithmic complexity analyses may lead to incorrect or naive conclusions, especially in systems with high data I/O overhead such as grid computing. Further, it implies that systems which reduce or eliminate this bottleneck such as in-memory processing could lead to a substantial increase in performance.

Creaner, Oisín↗

SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tube Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.

60 APPLIED LIFE SCIENCES↗

A Comparison of GoldSim, RESRAD-Onsite, and NORMALYSA Modeling Tools at Radioactive Waste Sites - 19480

Radioactive waste disposal and associated decision making is a challenging problem around the world. A strong performance assessment model plays a crucial role in making good management and remediation decisions and in optimizing the performance of a site. The International Atomic Energy Agency (IAEA) MODARIA II Working Group 1 (WG1) is comparing the performance of various modeling platforms used at Naturally Occurring Radioactive Material (NORM) and legacy waste sites to support risk-informed decision making. Neptune and Company, Inc. (Neptune) has developed probabilistic performance assessment models using the GoldSim system modeling software at a variety of radioactive waste sites. This paper presents a comparison between GoldSim and two other tools used to evaluate radiation exposure and their associated risks: the NORM And Legacy Site Assessment (NORMALYSA) tool used to assess risk at the Zapadnoe mill tailings site, and the residual radioactivity (RESRAD-Onsite) computer program used to calculate Authorized Limits at the Los Alamos National Laboratory (LANL). The International Atomic Energy Agency (IAEA) supported development of NORMALYSA based off of Ecolego 6.0, in which the user connects several universal modules, representing various environmental transport and exposure pathways, and enters in site-specific data. Further work with NORMALYSA has continued under the MODARIA II WG 1. A radionuclide transport and dose calculation model of the Zapadnoe uranium mill tailings site at the Pridneprovsky Chemical Plant in the Ukraine has been configured by MODARIA II WG1 to test the capabilities of NORMALYSA. Under this test case, contaminant transport and effective dose calculations were performed for two exposure scenarios. The onsite worker is exposed via external ground irradiation and radon and radioactive dust inhalation. The offsite resident defines a residence established 300 years after institutional control has ended, 800 meters downstream from the site with exposure pathways including: ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from the Konoplyanka River and agricultural activities in the contaminated garden. GoldSim modeling software is a dynamic probabilistic modeling platform that evaluates uncertainty in a robust and transparent manner. Although GoldSim provides contaminant and radionuclide transport modules to facilitate integrated modeling of radionuclide migration in the environment, these features are not embedded in an existing modeling framework, except as created by the user. Neptune developed a GoldSim model for the two exposure scenarios of the Zapadnoe test case. Neptune's Generic PA Model was used as a starting point for the Zapadnoe site. Input parameters for the GoldSim model include site-specific parameters from the MODARIA Working Group as well as parameters from the Generic PA Model and other PA models created by Neptune. For the other comparison, Version 7.0 of RESRAD-Onsite, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE), was used to calculate Authorized Limits for LANL. Authorized Limits are concentrations of radionuclides in soil that support the evaluation process to clear land for release under different uses. The RESRAD-Onsite computer code was used to calculate Authorized Limits because this program was specifically designed to derive radionuclide soil guidelines corresponding to a specific dose criterion. The scope of the RESRAD dose or risk evaluation is constrained to the transport and exposure pathways that have been included in the computer code. To assist in illustrating the capability of GoldSim modeling software, a GoldSim model was created to replicate the calculation of LANL's Authorized Limits for soil. The main exposure pathways in this model are inhalation of dust and gas, plant ingestion, soil ingestion, and external ground irradiation. All of the processes and outputs of RESRAD-Onsite and NORMALYSA can be created in a GoldSim model, but the value of GoldSim lies in its flexibility for application to any of a wide variety of environmental modeling problems. GoldSim allows development of site-specific inventory, transport mechanisms and risk assessment scenarios. If all potentially complete release, transport, and exposure pathways are addressed in an existing dose and risk assessment computer code, and if the code's capabilities fulfill the project modeling objectives, then expending resources to create a GoldSim model may not be necessary. Site optimization and good decision making about site management are often best when supported with the flexibility of GoldSim as a modeling tool. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices over the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Comparison of software models for energy savings from cool roofs

For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savings to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

C3PU:Real-Time Predictive Charge Control Software for Battery Management Systems (Code for Charge Control and Predictive Unit) [SWR-21-48]

C3PU sets up a model predictive control formulation for the optimal charging control of battery packs and can be deployed for real-time operation on an embedded microprocessor. C3PU uses electrochemical and thermal models of battery packs to predict the charging trajectories of the battery pack over a time horizon under different operating conditions. It then selects the optimal charging trajectory such that a pre-defined objective is minimized, which in the present state of the code is to minimize the charging duration of the battery pack. The optimal charging trajectory is obtained by solving an underlying mathematical problem. However, C3PU is flexible to incorporate other charging objectives. The underlying battery models can be swapped as well, as long as they follow certain mathematical properties. Mathematically, optimal control problems (in this case, optimally controlling the charging current of the battery pack) are computationally expensive. C3PU implements advanced numerical techniques, namely pseudo-spectral optimization, to reduce the computational burden of the underlying problem to solve. This allows for the problem to be solved in real-time in an embedded system. Once the optimal charging trajectory is computed over a time horizon, C3PU can package such data and send it out via appropriate communication protocols.

Mishra, Partha↗

Earth and Space Science Informatics Perspectives on Integrated, Coordinated, Open, Networked (ICON) Science

Abstract This article is composed of three independent commentaries about the state of Integrated, Coordinated, Open, Networked (ICON) principles (Goldman, et al., 2021b, https://doi.org/10.1029/2021EO153180 ) in Earth and Space Science Informatics (ESSI) and includes discussion on the opportunities and challenges of adopting them. Each commentary focuses on a different topic: (Section 2) Global collaboration, cyberinfrastructure, and data sharing; (Section 3) Machine learning for multiscale modeling; (Section 4) Aerial and satellite remote sensing for advancing Earth system model development by integrating field and ancillary data. ESSI addresses data management practices, computation and analysis, and hardware and software infrastructure. Our role in ICON science therefore involves collaborative work to assess, design, implement, and promote practices and tools that enable effective data management, discovery, integration, and reuse for interdisciplinary work in Earth and space science disciplines. Networks of diverse people with expertise across Earth, space, and data science disciplines are essential for efficient and ethical exchanges of findable, accessible, interoperable, and reusable (FAIR) research products and practices. Our challenge is then to coordinate the development of standards, curation practices, and tools that enable integrating and reusing multiple data types, software, multi‐scale models, and machine learning approaches across disciplines in a way that is as open and/or FAIR as ethically possible. This is a major endeavor that could greatly increase the pace and potential of interdisciplinary scientific discovery.

58 GEOSCIENCES↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗