Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoelectric Actuator/Sensor Technology at Rockwell

We describe the state-of-the art of piezoelectric materials based on perovskite and tungsten bronze families for sensor, actuator and smart structure applications. The microstructural defects in these materials have been eliminated to a large extent and the resulting materials exhibit exceedingly high performance for various applications. The performance of Rockwell actuators/sensors is at least 3 times better than commercially available products. These high performance actuators are being incorporated into various applications including, DOD, NASA and commercial. The multilayer actuator stacks fabricated from our piezoceramics are advantageous for sensing and high capacitance applications. In this presentation, we will describe the use of our high performance piezo-ceramics for actuators and sensors, including multilayer stacks and composite structures.

Neurgaonkar, Ratnakar R.↗

Camera Simulation for the Perseverance Rover’s Lander Vision System

On February 18, 2021, the Perseverance Rover safely landed on Mars at Jezero Crater. Part of the successful landing was due to the Lander Vision System (LVS), which takes descent images from the LVS Camera (LCAM) and IMU measurements and estimates the lander position relative to a map of the Jezero landing site. The LVS Simulation LCAM (LVSS LCAM) model is an image rendering program developed to test the LVS in a variety of scenarios to ensure performance amid uncertainty. The LVSS LCAM model includes a pointing misalignment model, an exposure timing model, shadowing, a terrain reflectance model, atmospheric attenuation from dust, and sensor effects. This model was used for performance analysis, verification, and validation of the LVS algorithms in a Mars-like simulation prior to landing. This paper describes the LVSS LCAM rendering algorithm and compares flight images from LVS operation during the Perseverance landing with their rendered counterparts.

Zheng, Jason↗

Assessment of Selected CERES Electronic Component Survivability under Simulated Overvoltage Conditions

In August, 1998 a Clouds and the Earth's Radiant Energy System (CERES) instrument telemetry housekeeping parameter generated a yellow warning message that indicated an on-board + 15V Data Acquisition Assembly (DAA) power converter deregulation anomaly. An exhaustive investigation was undertaken to understand this anomaly and the long-term consequences which have severely reduced CERES operations on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. Among investigations performed were ground tests that approximated the on-board electronic circuitry using a small quantity of flight identical components exposed to maximum spacecraft bus over-voltage conditions. These components include monolithic integrated microcircuits that perform analog signal conditioning on instrument sensor signals and an analog- to-digital converter (ADC) for the entire DAA. All microcircuit packages have either a bipolar silicon design with internal current limiting protections or have a complementary metal oxide semiconductor (CMOS) design with bias protections. Ground tests that have been running for approximately 8 months have indicated that these components are capable of withstanding as much as twice their input supply voltage ratings without noticeable performance degradation. These data provide CERES operators with confidence of being able to continue science operations over the remaining life of the TRMM mission. This paper will discuss this anomaly and some possible causes, a simulator of affected electronics, test results, prognosis for future CERES operations, and conclusions.

Chapman, John J.↗

Global Space-Based Inter-Calibration System Reflective Solar Calibration Reference: From Aqua MODIS to S-NPP VIIRS

The MODIS has successfully operated on-board the NASA's EOS Terra and Aqua spacecraft for more than 16 and 14 years, respectively. MODIS instrument was designed with stringent calibration requirements and comprehensive on-board calibration capability. In the reflective solar spectral region, Aqua MODIS has performed better than Terra MODIS and, therefore, has been chosen by the Global Space-based Inter-Calibration System (GSICS) operational community as the calibration reference sensor in cross-sensor calibration and calibration inter-comparisons. For the same reason, it has also been used by a number of earth observing sensors as their calibration reference. Considering that Aqua MODIS has already operated for nearly 14 years, it is essential to transfer its calibration to a follow-on reference sensor with a similar calibration capability and stable performance. The VIIRS is a follow-on instrument to MODIS and has many similar design features as MODIS, including their on-board calibrators (OBC). As a result, VIIRS is an ideal candidate to replace MODIS to serve as the future GSICS reference sensor. Since launch, the S-NPP VIIRS has already operated for more than 4 years and its overall performance has been extensively characterized and demonstrated to meet its overall design requirements. This paper provides an overview of Aqua MODIS and S-NPP VIIRS reflective solar bands (RSB) calibration methodologies and strategies, traceability, and their on-orbit performance. It describes and illustrates different methods and approaches that can be used to facilitate the calibration reference transfer, including the use of desert and Antarctic sites, deep convective clouds (DCC), and the lunar observations.

Xiong, Xiaoxiong↗

Active figure maintenance control using an optical truss laser metrology system for a space-based far-IR segmented telescope

A two-stage active control approach was developed addressing the figure control problem for a spaceborne FIR telescope, the Precision Segmented Reflectors Focus Moderate Mission Telescope (FMMT). The first active control stage aligns the optical segments based on images; attention is here given to the second stage, active figure maintenance control system, which maintains the alignment of the optical elements between initializations to hold the mirror figure steady while obtaining data and fixes translational and rotational changes of the optical segments induced by long-term thermal drifts of the support structure. Errors are expected to be 10-100 microns at the nodes of the primary backup structure over the course of an orbit. An rms performance of 0.8 microns of wavefront error can be expected during the maintenance function based on specified nominal sensor noises, actuator accuracies, and system environments. A performance of less than 0.3 microns rms can be expected, based on advanced components.

Lau, Kenneth↗

Parametric Characterization of TES Detectors Under DC Bias

The X-ray integrated field unit (X-IFU) in European Space Agency's (ESA's) Athena mission will be the first high-resolution X-ray spectrometer in space using a large-format transition-edge sensor microcalorimeter array. Motivated by optimization of detector performance for X-IFU, we have conducted an extensive campaign of parametric characterization on transition-edge sensor (TES) detectors with nominal geometries and physical properties in order to establish sensitivity trends relative to magnetic field, dc bias on detectors, operating temperature, and to improve our understanding of detector behavior relative to its fundamental properties such as thermal conductivity, heat capacity, and transition temperature. These results were used for validation of a simple linear detector model in which a small perturbation can be introduced to one or multiple parameters to estimate the error budget for X-IFU. We will show here results of our parametric characterization of TES detectors and briefly discuss the comparison with the TES model.

X-ray Integral Field↗

Self-contained, automated, long-term sensor system for monitoring of soil and water nutrients in fields

An automated, fieldable ion-selective sensor system for frequent detection of nutrients in soils or water is set forth. In one aspect, an integrated small form-factor housing includes a battery, processor, a fluid manipulation unit and reservoirs, and a chemical species detection cell. A flow-through sampling head can be connected to the detection cell and a waste reservoir by flexible tubing sealingly connected at opposite ends of the tube. In one aspect, improved performance of the ion-selective sensor includes adding an ion-to-electron transfer interlayer between an ion-selective membrane and its working electrode. In one aspect, the sensor is solid-state and uses printed polymeric composite of POT-MoS$_{2}$. The use of a porous tube for a sampling head and fluid connection at opposite ends allows not only fluid to be removed from the head to the detection cell for measurement but also flow in an opposite direction and out to a waste reservoir to clean and reset for a next sample measurement.

60 APPLIED LIFE SCIENCES↗

A real time microcomputer implementation of sensor failure detection for turbofan engines

An algorithm was developed which detects, isolates, and accommodates sensor failures using analytical redundancy. The performance of this algorithm was demonstrated on a full-scale F100 turbofan engine. The algorithm was implemented in real-time on a microprocessor-based controls computer which includes parallel processing and high order language programming. Parallel processing was used to achieve the required computational power for the real-time implementation. High order language programming was used in order to reduce the programming and maintenance costs of the algorithm implementation software. The sensor failure algorithm was combined with an existing multivariable control algorithm to give a complete control implementation with sensor analytical redundancy. The real-time microprocessor implementation of the algorithm which resulted in the successful completion of the algorithm engine demonstration, is described.

Delaat, John C.↗

Flight Test Performance of a High Precision Navigation Doppler Lidar

A navigation Doppler Lidar (DL) was developed at NASA Langley Research Center (LaRC) for high precision velocity measurements from a lunar or planetary landing vehicle in support of the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project. A unique feature of this DL is that it has the capability to provide a precision velocity vector which can be easily separated into horizontal and vertical velocity components and high accuracy line of sight (LOS) range measurements. This dual mode of operation can provide useful information, such as vehicle orientation relative to the direction of travel, and vehicle attitude relative to the sensor footprint on the ground. System performance was evaluated in a series of helicopter flight tests over the California desert. This paper provides a description of the DL system and presents results obtained from these flight tests.

Pierrottet, Diego↗

A real time microcomputer implementation of sensor failure detection for turbofan engines

An algorithm was developed that detects, isolates, and accommodates sensor failures using analytical redundancy. The performance of this algorithm has been demonstrated on a full-scale F100 turbofan engine. The algorithm was implemented in real-time on a microprocessor-based controls computer which includes parallel processing and high order language programming. Parallel processing was used to achieve the required computational power for the real-time implementation. High order language programming was used in order to reduce the programming and maintenance costs of the algorithm implementation software. The sensor failure algorithm was combined with an existing multivariable control algorithm to give a complete control implementation with sensor analytical redundancy. The real-time microprocessor implementation of the algorithm, which resulted in the successful completion of the algorithm engine demonstration, is described.

Delaat, John C.↗

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wireless Sensor Instrumentation for Distributed Sensing in Ground-Test Facilities

Wireless sensors have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Relative to wireless alternatives, traditional wired systems encounter limitations including spatial and weight constraints, maintenance costs, and signal integrity in high-noise environments. Ground-test facilities often face these challenges and cause increase down-time costs and failure of data integrity. This paper describes the development and implementation of flexible wireless sensor boards for applications within ground-test facilities using different network architectures. These boards implement state-of-the- art STM32 microprocessor chips for high-speed data acquisition and computational power. Additionally, the design integrates long-range radio transceivers with power output of +20dBm, easily reaching 2 km range, while maintaining high interference immunity and minimizing current consumption. The wireless sensor boards were implemented to demonstrate performance through benchmark testing and by taking distributed electrically-isolated measurements on a high-voltage lab apparatus while using different network architectures. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

IKONOS Spatial Resolution and Image Interpretability Characterization

This paper contains research from five individual projects to characterize the spatial performance of the IKONOS commercial imaging sensor. The end result of the projects is determination of the spatial image quality of IKONOS data prodicts in terms of the National Imagery Interpretability Rating Scale (NIIRS), the system Modulation Transfer Function (MTF), the system stability over the first year, the characteristics of the Space Imaging MTF Compensation (MTFC) procedure, and the application-specific capabilities of IKONOS imagery. Both panchromatic and multispectral imagery were evaluated. Major conclusions of this work are that the system was stable im imaging performance during the first year of operation, tha its MTF meets the specification for the NASA Scientific Data Purchase program, that the initial MTFC processing appears to be transposed in the in-track and the cross-track directions, that the MTFC results in a noise amplification of 2x to 4x in addition to sharpening the imagery, and that IKONOS panchromatic imagery achieves an average NIIRS rating of 4.5.

Ryan, Robert↗

Multi-Angle Imaging SpectroRadiometer (MISR) Design Issues Influenced by Performance Requirements

The design of an Earth remote sensing sensor, such as the Multi-angle Imaging SpectroRadiometer (MISR), begins with a set of science requirements that determine a set of instrument specifications. It is required that the sensor meet these specifications across the image field, over a range of sensor operating temperatures, and throughout mission life. In addition, data quality must be maintained irrespective of bright objects, such as clouds, within the scene, or out-of-field glint sources. During the design phase of MISR, many refinements to the conceptual design have been made to insure that these performance criteria are met. These design considerations are the focus of this paper. Spectral stability with field angle, scene polarization insensitivity, and LTV exposure hardness have, for example, been enabled through a telecentric optical design, a gaussian shaped filter spectral profile used in conjunction with a Lyot depolarizer, and contamination prevention through consideration of material choices and handling procedures. Spectral, radiometric, and MTF stability of the instrument assures the scientific community that MISR imagery can be used for highly accurate aerosol, bi-directional reflectance distribution function (BRDF), and cloud studies.

Bruegge, Carol J.↗

NASA SPLICE Project: Development and Testing of Precision Landing GN&C Technologies

NASA's technology advancement needs for entry, descent and landing call for high-precision, high-rate sensors that can improve navigation accuracy and vehicle control performance. Higher landing accuracy is required for any future human lander missions, and likely, for most robotic missions 1,2. Sensors and algorithms that significantly reduce navigation errors and can image the local terrain will enable landing at locations of high scientific interest that would otherwise pose significant risk to the vehicle. The Safe and Precise Landing-Integrated Capabilities Evolution project, or SPLICE, is developing precision landing and hazard avoidance (PL&HA) technologies for NASA and for potential commercial space flight missions. SPLICE technologies include sensors, algorithms, advanced space flight computing capabilities, and simulation tools used to integrate and study guidance, navigation, and control (GN&C) system performance. SPLICE efforts include hardware-in-the-loop (HWIL) simulation testing, ground testing, and flight testing, including reuse of hardware from the CoOperative Blending of Autonomous Landing Technologies (COBALT) suborbital flight-test payload3,4. Two of the precise navigation sensors that are being developed and matured within SPLICE are LiDARs. Since 2006, NASA Langley has been developing a Navigation Doppler LiDAR (NDL) for precise velocity measurements, and SPLICE is building an NDL engineering test unit (ETU) that will be brought up to TRL 6 following environmental and high-speed1,2 testing. NASA Goddard is developing a Hazard Detection LiDAR (HD LiDAR) engineering development unit (EDU) for SPLICE that has relevance to future human and robotic lander missions. The HD LiDAR will be flight test and matured to TRL 5.

Restrepo, Carolina I.↗

Effect of rawinsonde errors on rocketsonde density and pressure profiles: An error analysis of the Rawinsonde System

An initial value of pressure is required to derive the density and pressure profiles of the rocketborne rocketsonde sensor. This tie-on pressure value is obtained from the nearest rawinsonde launch at an altitude where overlapping rawinsonde and rocketsonde measurements occur. An error analysis was performed of the error sources in these sensors that contribute to the error in the tie-on pressure. It was determined that significant tie-on pressure errors result from radiation errors in the rawinsonde rod thermistor, and temperature calibration bias errors. To minimize the effect of these errors radiation corrections should be made to the rawinsonde temperature and the tie-on altitude should be chosen at the lowest altitude of overlapping data. Under these conditions the tie-on error, and consequently the resulting error in the Datasonde pressure and density profiles is less tha 1%. The effect of rawinsonde pressure and temperature errors on the wind and temperature versus height profiles of the rawinsonde was also determined.

Luers, J. K.↗

Airborne reconnaissance XIII; Proceedings of the Meeting, San Diego, CA, Aug. 7-9, 1989

The present conference on airborne reconnaissance discusses topics in imagery exploitation, reconsystem modeling and analysis, and reconnaissance optics and electronics configurations. Attention is given to airborne minefield detection, the optimization of an IR linescanner for RPV operations, real-time display of IR linescanner data for RPVs, three-dimensional model-guided site recognition, the AMIDARS high-performance real-time display, and MMW sensor image analysis. Also discussed are reconnaissance concepts for the 3-5 micron spectral window, sensor concept development for hazard detection, a stabilization system for a large aperture camera, three-axis image stabilization with a two-axis mirror, the results of performance tests on the TOW target collimator design, and the replacement of film by electrooptic media in advanced tactical airborne reconnaissance.

Henkel, Paul A.↗