Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Sample Return Systems for Extreme Environments (SaRSEE)

Sample return missions offer a greater science yield when compared to missions that only employ in situ experiments or remote sensing observations, since they allow the application of more complex technological and analytical methodologies in controlled terrestrial laboratories,that are both repeatable and can be independently verified. The successful return of extraterrestrial materials over the last four decades has contributed to our understanding of the solar system, but retrieval techniques have largely depended on the use of either soft-landing, or touch-and-go procedures that result in high V requirements, larger spacecraft mass ratios, and return yields typically limited to a few grams of surface materials that have experienced varying degrees of alteration from space weathering. Hard-landing methods using planetary penetrators offer an alternative for sample return that significantly reduce a mission's V and mass ratios,increase sample yields, and allow for the collection of subsurface materials, and lessons can be drawn from previous sample return missions. The following details progress in the design,development, and testing of penetrator/sampler technology capable of surviving subsonic and low, supersonic impact velocities (<700 m/s) that would enable the collection of geologic materials using tether technology to return the sample to a passing spacecraft. The testing of energy absorbing material for protecting the sample, design evolution and field testing of the penetrator, and dynamic modeling of tether behavior during sampling are discussed. It is shown through both modeling and field testing that penetrators at speeds between 300-600 m/s (~Mach 1-2) can penetrator into the ground to depths of 1-2 m with overall structural integrity attained.The first flight tests demonstrated the potential for survivability at these speeds. The second flight series demonstrated core sample collection with partial ejection of the sample return canister. The 3rd flight series demonstrated self-ejection of the sample return system fully intact and with the core retaining the full stratigraphy of the rock bed. The tether analysis shows that the forces on the tether during release and return of the sample to the main spacecraft are all at levels that can easily be handled by existing tether materials. The mass analysis of the requirements indicates that sample return form the asteroids could be handled with Discovery or New Frontier range of missions dependent on the number of samples to be returned to the Earth.

Winglee, R. M.↗

CO 2 induced changes in Mount Simon sandstone: Understanding links to post CO 2 injection monitoring, seismicity, and reservoir integrity

The purpose of this study is to quantify geochemical reactions of CO 2 and brine with subsurface samples taken from the Mt. Simon sandstone and identify any potential alterations of the geomechanical rock properties that could lead to changes observable in seismic monitoring or result in changes of micro seismicity such as those observed at the Illinois Basin-Decatur Project (IBDP) site. Two Mt. Simon sandstone samples from 6919.3 feet (2109.0 m) and 6926.1 feet (2111.1 m) depth were exposed to supercritical CO 2 (scCO 2 ) dissolved in brine at in-situ reservoir conditions for one month. Geochemical, spectral, scanning electron microscopy, and petrophysical methods were used to analyze the samples before and after the one-month exposure. Significant changes were observed. Multiple geomechanical properties were chosen to form the framework against which to interrogate the petrophysical data: Young’s modulus (E), Poisson’s ratio (ν), lambda·rho (λρ), and mu·rho (μρ). In this study we conclude that framework composition, porosity, heterogeneities, effective pressure, and reactive geochemistry are first order controls on trends in the E-μ and λρ-μρ cross plot spaces. Changes in porosity, permeability, dynamic moduli, and brittleness with exposure to these fluids were observed. No change in ultrasonic P-wave attenuation (Q P ) was observed. Geochemical alteration causes a distinct shift in λρ-μρ in both samples as well as changes in E, ν, and P and S wave seismic velocity values. Furthermore, these observations could provide insight into subsurface monitoring using seismic methods including amplitude variation with offset (AVO) classification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

S-193 impulse response cross correlation

The author has identified the following significant results. A significant result was the realization that the phase information, normally lost in envelope detection and sampling, could have been preserved if the samples were taken at the peaks of the carrier frequency at intervals equal to a twice or an integral multiple of the integral number of its period. Thus the Skylab S193 Model 1 altimeter data does not contain phase information in accordance with the technical information obtained from NASA and Lockheed technical personnel. Another significant discovery was to learn that the eight return pulse samples don't belong to the same pulse but represent an average over many pulses.

Hayre, H. S.↗

Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures

Alignment of two-element telescopes is a classic problem. During recent integration and test of the Space Interferometry Mission s (SIM s) Astrometric Beam Combiner (ABC), the innovators were faced with aligning two such telescope subsystems in the presence of a further complication: only two small subapertures in each telescope s pupil were accessible for measuring the wavefront with a Fizeau interferometer. This meant that the familiar aberrations that might be interpreted to infer system misalignments could be viewed only over small sub-regions of the pupil, making them hard to recognize. Further, there was no contiguous surface of the pupil connecting these two subapertures, so relative phase piston information was lost; the underlying full-aperture aberrations therefore had an additional degree of ambiguity. The solution presented here is to recognize that, in the absence of phase piston, the Zygo measurements primarily provide phase tilt in the subaperture windows of interest. Because these windows are small and situated far from the center of the (inaccessible) unobscured full aperture, any aberrations that are higher-order than tilt will be extremely high-order on the full aperture, and so not necessary or helpful to the alignment. Knowledge of the telescope s optical prescription allows straightforward evaluation of sensitivities (subap mode strength per unit full-aperture aberration), and these can be used in a predictive matrix approach to move with assurance to an aligned state. The technique is novel in every operational way compared to the standard approach of alignment based on full-aperture aberrations or searching for best rms wavefront. This approach is closely grounded in the observable quantities most appropriate to the problem. It is also more intuitive than inverting full phase maps (or subaperture Zernike spectra) with a ray-tracing program, which must certainly work in principle, but in practice met with limited success. Even if such classical alignment techniques became practical, the techniques reported here form a reassuringly transparent and intuitive check on the course of the alignment with very little computational effort.

Bloemhof, Eric E.↗

2019 ARIA Proposal Final Report Public Abstract: What Happens to Life in an Ocean World Plume?

The NASA Cassini mission to Saturn discovered persistent jets of water being ejected into space from a subsurface ocean on the small moon Enceladus and evidence that this ocean is habitable for life. The ice resulting from these plumes forms the E Ring of Saturn. Missions are under study to fly through these plumes and collect and analyze samples to look for evidence of life. To support design and instrument selection for these missions, there is a critical need to understand what happens to microbial life adapted to a liquid environment when suddenly ejected into the vacuum of space. We experimentally determined the structural changes in microbial cells in liquid medium when ejected into vacuum. We first developed a vacuum chamber fitted with a feedthrough and nozzle allowing fluid to be injected into vacuum. The nozzle dispersed the fluid into micron-sized droplets. Fluid containing a population of E. Coli microbes was injected into the chamber and droplets were collected on microscope slides and small cups for imaging with a Scanning Electron Microscope (SEM). Epifluorescence microscopy, using a lipid stain, and SEM imaging were used to evaluate the cellular integrity of E. coli after injection through the pressurized nozzle into vacuum. The experimental samples showed a 94% decrease in visible intact E. coli cells as compared with control samples but showed a fluorescent residue in the shape of the sublimated droplets that indicated the presence of lipids. E. coli was selected for testing although other cell types could vary physiologically which could affect their response to a vacuum environment. More testing is needed to determine whether other types of microbial cells can survive the plume environment. However, these results suggest that lipids may be directly detectable evidence of life in icy world plumes, but organisms are unlikely to survive due to disruption of their cell walls.

C. R. Stoker↗

ORBIT-2 Dataset for Scaling Exascale Vision Foundation Models for Weather and Climate Downscaling

This dataset release corresponds to the work conducted in ORBIT-2: Scaling Exascale Vision Foundation Models for Weather and Climate Downscaling, where large-scale AI methods were applied to improve climate and weather resolution. The collection integrates four widely used, publicly available datasets: ERA5, PRISM, DAYMET, and IMERG. To prepare the data for ORBIT-2 model training and evaluation, we applied a preprocessing pipeline that generates paired low-resolution and high-resolution samples, enabling supervised downscaling experiments. The transformation from coarse to fine scales was performed using bilinear regridding, consistent with the procedures described in WeatherBench2, a community benchmark for weather and climate AI models. This dataset supports the development and evaluation of foundation models designed for weather and climate downscaling at exascale. Additional details on methodology and applications can be found in Wang et al., ORBIT-2 (arXiv:2505.04802, 2025).

54 ENVIRONMENTAL SCIENCES↗

Neutron capture effects in lunar gadolinium and the irradiation histories of some lunar rocks.

The Gd isotopic composition in 19 lunar rock and soil samples from three Apollo sites is reported. The analytical techniques and the high precision mass spectrometric measurements are discussed. Enrichments in the Gd-158 oxide to G-157 oxide ratio due to neutron capture range up to 0.75%. Integrated 'thermal' neutron fluxes derived from the isotopic anomalies of Gd are compared with spallation Kr data from aliquot samples to construct a model which gives both average cosmic-ray irradiation depths and effective neutron exposure ages for some rocks. Rock 14310 is the first lunar sample where Kr anomalies due to resonance neutron capture in Br are observed. A Kr-81/Kr exposure age of 262 (plus or minus 7)m.y. is calculated for this rock.

Lugmair, G. W.↗

Detection of Organic Constituents Including Chloromethylpropene in the Analyses of the ROCKNEST Drift by Sample Analysis at Mars (SAM)

key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.

Eigenbrode, J. L.↗

Thermal Soak Analysis of Earth Entry Vehicles

The Multi-Mission Earth Entry Vehicle project is developing an integrated tool called Multi Mission System Analysis for Planetary Entry Descent and Landing that will provide key technology solutions including mass sizing, aerodynamics, aerothermodynamics, and thermal and structural analysis for any given sample return mission. Thermal soak analysis and temperature predictions of various components including the payload container of the entry vehicle are part of the solution that this tool will offer to mission designers. The present paper focuses on the thermal soak analysis of an entry vehicle design based on the Mars Sample Return entry vehicle geometry and discusses a technical approach to develop parametric models for thermal soak analysis that will be integrated into the tool.

Agrawal, Parul↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stochastic solver based on the residence time algorithm for crystal plasticity models

Abstract The deformation of crystalline materials by dislocation motion takes place in discrete amounts determined by the Burgers vector. Dislocations may move individually or in bundles, potentially giving rise to intermittent slip. This confers plastic deformation with a certain degree of variability that can be interpreted as being caused by stochastic fluctuations in dislocation behavior. However, crystal plasticity (CP) models are almost always formulated in a continuum sense, assuming that fluctuations average out over large material volumes and/or cancel out due to multi-slip contributions. Nevertheless, plastic fluctuations are known to be important in confined volumes at or below the micron scale, at high temperatures, and under low strain rate/stress deformation conditions. Here, we develop a stochastic solver for CP models based on the residence-time algorithm that naturally captures plastic fluctuations by sampling among the set of active slip systems in the crystal. The method solves the evolution equations of explicit CP formulations, which are recast as stochastic ordinary differential equations and integrated discretely in time. The stochastic CP model is numerically stable by design and naturally breaks the symmetry of plastic slip by sampling among the active plastic shear rates with the correct probability. This can lead to phenomena such as intermittent slip or plastic localization without adding external symmetry-breaking operations to the model. The method is applied to body-centered cubic tungsten single crystals under a variety of temperatures, loading orientations, and imposed strain rates.

42 ENGINEERING↗

NEW CONSTRAINTS ON A COMPLEX RELATION BETWEEN GLOBULAR CLUSTER COLORS AND ENVIRONMENT

We present an analysis of high-quality photometry for globular clusters (GCs) in the Virgo cluster core region, based on data from the Next Generation Virgo Cluster Survey (NGVS) pilot field, and in the Milky Way (MW), based on Very Large Telescope/X-Shooter spectrophotometry. We find significant discrepancies in color–color diagrams between sub-samples from different environments, confirming that the environment has a strong influence on the integrated colors of GCs. GC color distributions along a single color are not sufficient to capture the differences we observe in color–color space. While the average photometric colors become bluer with increasing radial distance to the cD galaxy M87, we also find a relation between the environment and the slope and intercept of the color–color relations. A denser environment seems to produce a larger dynamic range in certain color indices. We argue that these results are not due solely to differential extinction, Initial Mass Function variations, calibration uncertainties, or overall age/metallicity variations. We therefore suggest that the relation between the environment and GC colors is, at least in part, due to chemical abundance variations, which affect stellar spectra and stellar evolution tracks. Our results demonstrate that stellar population diagnostics derived from model predictions which are calibrated on one particular sample of GCs may not be appropriate for all extragalactic GCs. These results advocate a more complex model of the assembly history of GC systems in massive galaxies that goes beyond the simple bimodality found in previous decades.

79 ASTRONOMY AND ASTROPHYSICS↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Itokawa's Opposition Surge seen by Hayabusa/AMICA

Using images acquired by the Hayabusa/AMICA instrument, along with Lederer et al.'s (2008) ground-based observations, we re-examine Itokawa's disk-integrated phase curve. The AMICA images provide critical opposition measurements (between 0.7deg - 9.3deg phase at 540 nm). Using Hapke's model (2012), we fit the updated phase curves at 5 different wavelengths. Preliminary modeling results show a range of porosity values commensurate with those in the literature (Ostro et al. 2004, Gundlach and Blum, 2012, Kiuchi and Nakamura 2014) based on an impact-generated grain size distribution function and grain size range evaluations from the AMICA data (Yano et al. 2006). This wide range on a global porosity is indicative of a highly variable porosity across the surface. The derived transport mean free path and the generally forward scattering nature of the global regolith are indicative of scattering centers (such as cracks, bubbles, and inclusions) that are small compared to the observational wavelengths. The derived regolith properties are compared with the imaging and sample analysis results, providing a test of the predictive capabilities of global disk-integrated measurements. This work suggests that the sub-pixel grain information could be extracted from the photometry, especially around opposition.

Dominque, D.↗

Formation Mechanisms and Leachability of Hexavalent Chromium in Cr{sub 2}O{sub 3}-Containing Refractory Castables of Electric Arc Furnace Cover

Cr (III)-containing refractories are widely used as electric-arc furnace cover because of their excellent corrosion resistance properties. However, the formation of hexavalent chromium [Cr(VI)] remains a matter of concern during the service and subsequent disposal of the spent refractories. Moreover, the Cr(VI) formation mechanism and total amount of Cr(VI) generated are not clearly understood. In this study, samples from different parts of a spent electric arc furnace cover were collected from a local integrated steel plant. The phase composition, microstructure, formation and leachability of Cr(VI) were investigated using X-ray photoelectron spectroscopy, X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy, and TRGS 613 leaching test (Technische Regeln für Gefahrstoffe-TRGS 613-October 2002)/multiple leaching tests. A Cr(VI)-containing phase namely CaCrO{sub 4} existed in the sample at a medium temperature range, while another Cr(VI)-containing phase namely hauyne (Ca{sub 4}Al{sub 6}CrO{sub 16}) and a Cr(III)-containing phase (Al{sub 2}O{sub 3}–Cr{sub 2}O{sub 3} solid solution) formed in the high temperature region. Concentrations of Cr(VI) in the leachates (as in the TRGS 613 procedure) exceeded the European permissible limit. During the leaching tests in an acid condition, Cr(VI) was reduced by Fe{sup 2+}, which was primarily derived from the dissolution of FeO in the samples, while more Cr(VI) leached out with distilled water. Formation of an Al{sub 2}O{sub 3}–Cr{sub 2}O{sub 3} solid solution can inhibit Cr(VI) generation.

36 MATERIALS SCIENCE↗

Ultrathin Pt x Sn 1–x Nanowires for Methanol and Ethanol Oxidation Reactions: Tuning Performance by Varying Chemical Composition

Pt-based alloys denote promising catalysts for the methanol oxidation reaction (MOR) and the ethanol oxidation reaction (EOR), due to their enhanced activity toward alcohol-oxidation reactions and reduced cost as compared with Pt alone. Among all of these binary systems, PtSn has been reported to exhibit superior methanol/ethanol oxidation activity. In this paper, we deliberatively tailor chemical composition, reduce size, and optimize morphology of the catalyst in an effort to understand structure–property correlations that can be used to improve upon the electrocatalytic activity of these systems. Previous work performed by our group suggested that Pt-based catalysts, possessing an ultrathin one-dimensional (1D) structure, dramatically promote both cathodic and anodic reactions with respect to their zero-dimensional (0D) counterparts. Herein, a novel set of ultrathin binary Pt–Sn 1D nanowire (NW) catalysts with rationally controlled chemical compositions, i.e., Pt 9 Sn 1 , Pt 8 Sn 2 , and Pt 7 Sn 3 , has been synthesized using a facile, room-temperature, wet-solution-based method. The crystallinity and chemical composition of these as-prepared samples were initially characterized using XRD, XPS, and EDX. Results revealed that this synthetic protocol could successfully generate PtSn alloys with purposely tunable chemical compositions. TEM and HRTEM verified the structural integrity of our ultrathin 1D NW morphology for our Pt 9 Sn 1 , Pt 8 Sn 2 , and Pt 7 Sn 3 samples. The effects of varying Sn content within these alloy samples toward the electro-oxidation reaction of methanol and ethanol were probed using cyclic voltammetry (CV) in acidic media. Finally, within this series, we find that the optimized chemical composition for both the MOR and the EOR is Pt 7 Sn 3 .

36 MATERIALS SCIENCE↗

Thermal conductance of pressed contacts at liquid helium temperatures

The thermal contact conductance of a 0.4 micrometer surface finish OFHC copper sample pair has been investigated from 1.6 to 3.8 K for a range of applied contact forces up to 670 N. Experimental data have been fitted to the relation Q = the integral alpha T to the nth power dt by assuming that the thermal contact conductance is a simple power function of the sample temperature. It has been found that the conductance is proportional to T squared and that conductance increases with an increase in applied contact force. These results confirm earlier work.

Salerno, L. J.↗

Feedback Augmented Sub-Ranging (FASR) Quantizer

This innovation is intended to reduce the size, power, and complexity of pipeline analog-to-digital converters (ADCs) that require high resolution and speed along with low power. Digitizers are important components in any application where analog signals (such as light, sound, temperature, etc.) need to be digitally processed. The innovation implements amplification of a sampled residual voltage in a switched capacitor amplifier stage that does not depend on charge redistribution. The result is less sensitive to capacitor mismatches that cause gain errors, which are the main limitation of such amplifiers in pipeline ADCs. The residual errors due to mismatch are reduced by at least a factor of 16, which is equivalent to at least 4 bits of improvement. The settling time is also faster because of a higher feedback factor. In traditional switched capacitor residue amplifiers, closed-loop amplification of a sampled and held residue signal is achieved by redistributing sampled charge onto a feedback capacitor around a high-gain transconductance amplifier. The residual charge that was sampled during the acquisition or sampling phase is stored on two or more capacitors, often equal in value or integral multiples of each other. During the hold or amplification phase, all of the charge is redistributed onto one capacitor in the feedback loop of the amplifier to produce an amplified voltage. The key error source is the non-ideal ratios of feedback and input capacitors caused by manufacturing tolerances, called mismatches. The mismatches cause non-ideal closed-loop gain, leading to higher differential non-linearity. Traditional solutions to the mismatch errors are to use larger capacitor values (than dictated by thermal noise requirements) and/or complex calibration schemes, both of which increase the die size and power dissipation. The key features of this innovation are (1) the elimination of the need for charge redistribution to achieve an accurate closed-loop gain of two, (2) a higher feedback factor in the amplifier stage giving a higher closed-loop bandwidth compared to the prior art, and (3) reduced requirement for calibration. The accuracy of the new amplifier is mainly limited by the sampling networks parasitic capacitances, which should be minimized in relation to the sampling capacitors.

Guilligan, Gerard↗