Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reflection data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

ARM Cloud Radar Simulator Package for Global Climate Models Value-Added Product

It has been challenging to directly compare U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility ground-based cloud radar measurements with climate model output because of limitations or features of the observing processes and the spatial gap between model and the single-point measurements. To facilitate the use of ARM radar data in numerical models, an ARM cloud radar simulator was developed to converts model data into pseudo-ARM cloud radar observations that mimic the instrument view of a narrow atmospheric column (as compared to a large global climate model [GCM] grid-cell), thus allowing meaningful comparison between model output and ARM cloud observations. The ARM cloud radar simulator value-added product (VAP) was developed based on the CloudSat simulator contained in the community satellite simulator package, the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package (COSP) (Bodas-Salcedo et al., 2011), which has been widely used in climate model evaluation with satellite data (Klein et al., 2013, Zhang et al., 2010). The essential part of the CloudSat simulator is the QuickBeam radar simulator that is used to produce CloudSat-like radar reflectivity, but is capable of simulating reflectivity for other radars (Marchand et al., 2009; Haynes et al., 2007). Adapting QuickBeam to the ARM cloud radar simulator within COSP required two primary changes: one was to set the frequency to 35 GHz for the ARM Ka-band cloud radar, as opposed to 94 GHz used for the CloudSat W-band radar, and the second was to invert the view from the ground to space so as to attenuate the beam correctly. In addition, the ARM cloud radar simulator uses a finer vertical resolution (100 m compared to 500 m for CloudSat) to resolve the more detailed structure of clouds captured by the ARM radars. The ARM simulator has been developed following the COSP workflow (Figure 1) and using the capabilities available in COSP wherever possible. The ARM simulator is written in Fortran 90, just as is the COSP. It is incorporated into COSP to facilitate use by the climate modeling community. In order to evaluate simulator output, the observational counterpart of the simulator output, radar reflectivity-height histograms (CFAD) is also generated from the ARM observations. This report includes an overview of the ARM cloud radar simulator VAP and the required simulator-oriented ARM radar data product (radarCFAD) for validating simulator output, as well as a user guide for operating the ARM radar simulator VAP.

54 ENVIRONMENTAL SCIENCES↗

Modeling pulse-cleaning plasma mirrors from dielectric response to saturation: A particle-in-cell approach

Pulse-cleaning plasma mirrors are widely employed to improve ultraintense laser contrast, but much of the literature concerning their effect on the reflected pulse is empirical. A simulation study of pulse-cleaning plasma mirrors using the particle-in-cell code large scale plasma is presented here. The importance of capturing initial ionization from neutral atoms, collisional effects, and simulation dimensionality is considered. Excellent agreement with experimental data is obtained when a multiphoton ionization model is employed. Furthermore, a series of 2D simulations is shown to accurately replicate both the reflected light intensity and mode obtained from full 3D simulations at significantly reduced computation cost.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

PHOBOS AS A D-TYPE CAPTURED ASTEROID, SPECTRAL MODELING FROM 0.25 TO 4.0 μm

This paper describes the spectral modeling of the surface of Phobos in the wavelength range between 0.25 and 4.0 μm. We use complementary data to cover this spectral range: the OSIRIS (Optical, Spectroscopic, and Infrared Remote Imaging System on board the ESA Rosetta spacecraft) reflectance spectrum that Pajola et al. merged with the VSK-KRFM-ISM (Videospectrometric Camera (VSK)-Combined Radiometer and Photometer for Mars (KRFM)-Imaging Spectrometer for Mars (ISM) on board the USSR Phobos 2 spacecraft) spectra by Murchie and Erard and the IRTF (NASA Infrared Telescope Facility, Hawaii, USA) spectra published by Rivkin et al. The OSIRIS data allow the characterization of an area of Phobos covering from 86.°8 N to 90° S in latitude and from 126° W to 286° W in longitude. This corresponds chiefly to the trailing hemisphere, but with a small sampling of the leading hemisphere as well. We compared the OSIRIS results with the Trojan D-type asteroid 624 Hektor and show that the overall slope and curvature of the two bodies over the common wavelength range are very similar. This favors Phobos being a captured D-type asteroid as previously suggested. We modeled the OSIRIS data using two models, the first one with a composition that includes organic carbonaceous material, serpentine, olivine, and basalt glass, and the second one consisting of Tagish Lake meteorite and magnesium-rich pyroxene glass. The results of these models were extended to longer wavelengths to compare the VSK-KRFM-ISM and IRTF data. The overall shape of the second model spectrum between 0.25 and 4.0 μm shows curvature and an albedo level that match both the OSIRIS and Murchie and Erard data and the Rivkin et al. data much better than the first model. The large interval fit is encouraging and adds weight to this model, making it our most promising fit for Phobos. Since Tagish Lake is commonly used as a spectral analog for D-type asteroids, this provides additional support for compositional similarities between Phobos and D-type asteroids.

79 ASTRONOMY AND ASTROPHYSICS↗

Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients with pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fano Resonance in GaAs 2D Photonic Crystal Nanocavities

We report the results of polarization resolved reflectivity experiments in GaAs air-bridge photonic crystals with L3 cavities. We show that the fundamental L3 cavity mode changes, in a controlled way, from a Lorentzian symmetrical lineshape to an asymmetrical form when the linear polarization of the incident light is rotated in the plane of the crystal. The different lineshapes are well fitted by the Fano asymmetric equation, implying that a Fano resonance is present in the reflectivity. We use the scattering matrix method to model the Fano interference between a localized discrete state (the cavity fundamental mode) and a background of continuum states (the light reflected from the crystal slab in the vicinity of the cavity) with very good agreement with the experimental data.

36 MATERIALS SCIENCE↗

Inferring ultraviolet anatomical exposure patterns while distinguishing the relative contribution of radiation components

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. While ground UV irradiance is monitored via different techniques, it is difficult to translate such observations into human UV exposure or dose because of confounding factors. A multi-disciplinary collaboration developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop a simulation tool that estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. Dosimetric measurements obtained in field conditions were used to assess the model performance. The model predicted exposure to solar UV adequately with a symmetric mean absolute percentage error of 13% and half of the predictions within 17% range of the measurements. Using this tool, solar UV exposure patterns were investigated with respect to the relative contribution of the direct, diffuse and reflected radiation. Exposure doses for various body parts and exposure scenarios of a standing individual were assessed using erythemally-weighted UV ground irradiance data measured in 2009 at Payerne, Switzerland as input. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 Standard Erythemal Dose, SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e.g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

The inherent tensions arising from attempting to carry out strategic environmental assessments on all policies, plans and programmes

This paper evaluates the tensions that result from routinely applying SEA to all policies, plans and programmes within Scotland. The European Union SEA Directive, effective in many EU member states from 2004, introduced a requirement for environmental assessment of certain plans and programmes. Scotland, a devolved nation within the EU member state of the United Kingdom, aimed to be a 'world leader in SEA' by legislating for SEA to be undertaken of all public sector plans, programmes and strategies, with the word 'strategies' being equated with 'policies'. This paper presents detailed data regarding Scottish SEA activity between 2004 and 2007, including responses to consultations on SEA reports. This empirical research found that, reflecting a general difficulty in determining where and when SEA should be applied, engagement with the SEA process was not as widespread as intended (including the pre-screening and screening stages). Eight tensions evident from Scotland's application of SEA are identified, and their broader relevance is examined. - Highlights: Black-Right-Pointing-Pointer We examine detailed data regarding Scottish strategic environmental assessment (SEA) activity. Black-Right-Pointing-Pointer There is a general difficulty in determining where SEA should be applied. Black-Right-Pointing-Pointer Engagement with the SEA process was not as widespread as intended. Black-Right-Pointing-Pointer Eight 'tensions' that question the efficacy of applying SEA to all plans, programmes and policies were identified.

54 ENVIRONMENTAL SCIENCES↗

Cell diameter measurements obtained with a handheld cell counter could be used as a surrogate marker of G2/M arrest and apoptosis in colon cancer cell lines exposed to SN-38

Highlights: •Chemo-sensitivity to SN-38 was assayed by the automated cell counter. •Colon cancer cell line, HCT116 cells were more sensitive to SN-38 than HT29 cells. •Increase of cell size reflects G2/M arrest. •Appearance of small particles indicates cell apoptosis. -- Abstract: In vitro assessment of chemosensitivity are important for experiments evaluating cancer therapies. The Scepter 2.0 cell counter, an automated handheld device based on the Coulter principle of impedance-based particle detection, enables the accurate discrimination of cell populations according to cell size and volume. In this study, the effects of SN-38, the active metabolite of irinotecan, on the colon cancer cell lines HCT116 and HT29 were evaluated using this device. The cell count data obtained with the Scepter counter were compared with those obtained with the {sup 3}H-thymidine uptake assay, which has been used to measure cell proliferation in many previous studies. In addition, we examined whether the changes in the size distributions of these cells reflected alterations in the frequency of cell cycle arrest and/or apoptosis induced by SN-38 treatment. In our experiments using the Scepter 2.0 cell counter, the cell counts were demonstrated to be accurate and reproducible measure and alterations of cell diameter reflected G2/M cell cycle arrest and apoptosis. Our data show that easy-to-use cell counting tools can be utilized to evaluate the cell-killing effects of novel treatments on cancer cells in vitro.

60 APPLIED LIFE SCIENCES↗

A Novel and Practical Method to Quantify the Quality of Mobility: The Mobility Energy Productivity Metric: Preprint

Recent technology innovations are enabling fundamental improvements in mobility systems, including options for new travel modes, methods, and opportunities to connect people with goods, services, and employment. A desire to quantify and compare both existing and emerging transportation options motivated development of the mobility energy productivity (MEP) metric described herein. The MEP metric fundamentally measures the potential of a city's transportation system to connect a person to a variety of services and activities that define a high-quality of life, relative to the convenience, cost and energy needed to provide these connections. Fundamentally derived from accessibility theory, the MEP advances practice by using readily available travel time data (either from web-based application programming interfaces (APIs) or outputs from an urban transportation model) combined with established parameters that reflect the energy intensity and cost of various travel modes, and relative frequency of activity engagement. The construction of the MEP metric allows for aggregation and disaggregation to the appropriate spatial, modal, and trip purpose resolution, as analysis needs dictate. The MEP could be used to compare alternative futures related to technology, infrastructure investment, or policy, providing a much-needed tool for planners, researchers, and analysts.

33 ADVANCED PROPULSION SYSTEMS↗

LAI, EVI, NDVI, and kNDVI in 23 pantropical forests affected by 21 cyclones

Statement of purpose: Cyclones alter the function and composition of tropical forests, making effects of intensifying cyclones on carbon-rich forests a critical topic of study. Here, we quantified cyclone-induced damage and recovery of 21 cyclone disturbances affecting 23 pantropical forest sites between 1988-2017 utilizing leaf area index (LAI), enhanced vegetation index (EVI), normalized difference vegetation index (NDVI), and transformed NDVI (kNDVI) values from Google Earth Engine. Field observations collected in a meta-analysis (Bomfim et al., 2022, in review) were used to ground-truth and test effects of soil resource availability and disturbance factors on damage and recovery. This meta-analysis also served as the basis to begin vegetation index extraction, utilizing unique site and date combinations, from tropical forests effect by cyclone disturbances. We began collecting NDVI (5km resolution) from the NOAA Climate Data Record (CDR) of AVHRR Normalized Difference Vegetation Index (NDVI), Version 5 data product (Vermote, 2019) for all case studies included, 42. Next, we began extracting Landsat data from Landsat 4, 5, and 8, courtesy of the U.S. Geological Survey, in search of higher resolution data. We selected a 3 by 3 Landsat pixel area, leading to a 90m resolution data extraction. The specific imagery used includes Landsat 4 USGS Landsat 4 TM Collection 1 Tier 1 TOA (top of atmosphere) Reflectance, Landsat 5 USGS Landsat 5 TM (thematic mapper) Collection 1 Tier 1 TOA Reflectance, and Landsat 8 USGS Landsat 8 Collection 1 Tier 1 TOA Reflectance. Within Google Earth Engine, we selected the date and location (latitude and longitude), calculated NDVI, kNDVI, and EVI utilizing Landsat bands (see metadata_NGEE-tropics_cyclones), and extracted post- and pre-cyclone values for each case study to calculate cyclone-induced change in the vegetative index. Due to limited spatial resolution of Landsat remote sensing data, MODIS products were investigated next. First, the MOD13Q1.006 Terra Vegetation Indices 16-Day Global 250m product was used to extract 250m EVI and NDVI (Didan, 2015) and then the MCD15A3H.006 MODIS Leaf Area Index/FPAR 4-Day Global 500m product product was used to extract LAI 500m (Myneni et al., 2015). Pre- and post-cyclone values, change in the vegetative index, and standard deviation for all values are included in the main csv (see case_study_data.csv) for all vegetative indices collected, including LAI 500m, EVI 250m, NDVI 250m, NDVI 90m, kNDVI 90m, EVI 90m, and NDVI 5km. Lastly, recovery values were calculated utilizing a standardization method (see metadata_NGEE-tropics_cyclones) and recovery values for MODIS (see MODIS_recovery.csv) and Landsat (Landsat_recovery.csv) data are included.

54 ENVIRONMENTAL SCIENCES↗

Dual echelon femtosecond single-shot spectroscopy

We have developed a femtosecond single-shot spectroscopic technique to measure irreversible changes in condensed phase materials in real time. Crossed echelons generate a two-dimensional array of time-delayed pulses with one femtosecond probe pulse. This yields 9 ps of time-resolved data from a single laser shot, filling a gap in currently employed measurement methods. We can now monitor ultrafast irreversible dynamics in solid-state materials or other samples that cannot be flowed or replenished between laser shots, circumventing limitations of conventional pump-probe methods due to sample damage or product buildup. Despite the absence of signal-averaging in the single-shot measurement, an acceptable signal-to-noise level has been achieved via background and reference calibration procedures. Pump-induced changes in relative reflectivity as small as 0.2%−0.5% are demonstrated in semimetals, with both electronic and coherent phonon dynamics revealed by the data. The optical arrangement and the space-to-time conversion and calibration procedures necessary to achieve this level of operation are described. Sources of noise and approaches for dealing with them are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Damping constant estimation in magnetoresistive readers

The damping constant is a key design parameter in magnetic reader design. Its value can be derived from bulk or sheet film ferromagnetic resonance (FMR) line width. However, dynamics of nanodevices is usually defined by presence of non-uniform modes. It triggers new damping mechanisms and produces stronger damping than expected from traditional FMR. This work proposes a device-level technique for damping evaluation, based on time-domain analysis of thermally excited stochastic oscillations. The signal is collected using a high bandwidth oscilloscope, by direct probing of a biased reader. Recorded waveforms may contain different noise signals, but free layer FMR is usually a dominating one. The autocorrelation function is a reflection of the damped oscillation curve, averaging out stochastic contributions. The damped oscillator formula is fitted to autocorrelation data, producing resonance frequency and damping constant values. Restricting lag range allows for mitigation of the impact of other phenomena (e.g., reader instability) on the damping constant. For a micromagnetically modeled reader, the technique proves to be much more accurate than the stochastic FMR line width approach. Application to actual reader waveforms yields a damping constant of ∼0.03.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Montana Cropland Enrolled Farm Fields Carbon Sequestration Field Sampling, Measurement, Monitoring, and Verification: Application of Visible-Near Infrared Diffuse Reflectance Spectroscopy (VNIR) and Laser-induced Breakdown Spectroscopy (LIBS)

There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laboratory based soil characterization typically requires significant soil processing, which is time and resource intensive. This severely limits application for large-region soil characterization. Thus, development of rapid and accurate methods for characterizing soils are needed to map soil properties for precision agriculture applications, improve regional and global soil carbon (C) stock and flux estimates and efficiently map sub-surface metal contamination, among others. The greatest gains for efficient soil characterization will come from collecting soil data in situ, thus minimizing soil sample transportation, processing, and lab-based measurement costs. Visible and near-infrared diffuse reflectance spectroscopy (VisNIR) and laser-induced breakdown spectroscopy (LIBS) are two complementary, yet fundamentally different spectroscopic techniques that have the potential to meet this need. These sensors have the potential to be mounted on a soil penetrometer and deployed for rapid soil profile characterization at field and landscape scales. Details of sensor interaction, efficient data management, and appropriate statistical analysis techniques for model calibrations are first needed. In situ or on-the-go VisNIR spectroscopy has been proposed as a rapid and inexpensive tool for intensively mapping soil texture and organic carbon (SOC). While lab-based VisNIR has been established as a viable technique for estimating various soil properties, few experiments have compared the predictive accuracy of on-the-go and lab-based VisNIR. Eight north central Montana wheat fields were intensively interrogated using on-the-go and lab-based VisNIR. Lab-based spectral data consistently provided more accurate predictions than on-the-go data. However, neither in situ nor lab-based spectroscopy yielded even semi-quantitative SOC predictions. There was little SOC variability to explain across the eight fields, and on-the-go VisNIR was not able to capture the subtle SOC variability in these Montana soils. With more variation in soil clay content compared to SOC, both lab and on-the-go VisNIR showed better explanatory power. There are several potential explanations for poor on-the-go predictive accuracy: soil heterogeneity, field moisture, consistent sample presentation, and a difference between the spatial support of on-the-go measurements and soil samples collected for laboratory analyses. Though the current configuration of a commercially available on-the-go VisNIR system allows for rapid field scanning, on-the-go soil processing (i.e. drying, crushing, and sieving) could improve soil carbon predictions. Laser-induced breakdown spectroscopy (LIBS) is an emerging elemental analysis technology with the potential to provide rapid, accurate and precise analysis of soil constituents, such as carbon, in situ across landscapes. The research team evaluated the accuracy of LIBS for measuring soil profile carbon in field-moist, intact soil cores simulating conditions that might be encountered by a probe-mounted LIBS instrument measuring soil profile carbon in situ. Over the course of three experiments, more than120 intact soil cores from eight north central Montana wheat fields and the Washington State University (WSU) Cook Agronomy Farm near Pullman, WA were interrogated with LIBS for rapid total carbon (TC), inorganic carbon (IC), and SOC determination. Partial least squares regression models were derived and independently validated at field- and regional scales. Researchers obtained the best LIBS validation predictions for IC followed by TC and SOC. Laser-induced breakdown spectroscopy is fundamentally an elemental analysis technique, yet LIBS PLS2 models appeared to discriminate IC from TC. Regression coefficients from initial models suggested a reliance upon stoichiometric relationships between carbon (247.8 nm) and other elements related to total and inorganic carbon in the soil matrix [Ca (210.2 nm, 211.3 nm, and 220.9 nm), Mg (279.55-280.4 nm, 285.26 nm), and Si (251.6 nm, 288.1 nm)]. Expanding the LIBS spectral range to capture emissions from a broader range of elements related to soil organic matter was explored using two spectrometer systems to improve SOC predictions. Results for increasing the spectral range of LIBS to the full 200-800 nm found modest gains in prediction accuracy for IC, but no gains for predicting TC or SOC. Poor SOC predictions are likely a function of (1) the lack of a consistent/definable molecular composition of SOC, (2) relatively little variation in SOC across field sites, and (3) inorganic carbon constituting the primary form of soil carbon, particularly for Montana soils.

54 ENVIRONMENTAL SCIENCES↗

Interactions of cationic polystyrene nanoparticles with marine bivalve hemocytes in a physiological environment: Role of soluble hemolymph proteins

The bivalve Mytilus galloprovincialis has proven as a suitable model invertebrate for evaluating the potential impact of nanoparticles (NPs) in the marine environment. In particular, in mussels, the immune system represents a sensitive target for different types of NPs. In environmental conditions, both NP intrinsic properties and those of the receiving medium will affect particle behavior and consequent bioavailability/uptake/toxicity. However, the evaluation of the biological effects of NPs requires additional understanding of how, once within the organism, NPs interact at the molecular level with cells in a physiological environment. In mammalian systems, different NPs associate with serum soluble components, organized into a “protein corona”, which affects particle interactions with target cells. However, no information is available so far on the interactions of NPs with biological fluids of aquatic organisms. In this work, the influence of hemolymph serum (HS) on the in vitro effects of amino modified polystyrene NPs (PS-NH{sub 2}) on Mytilus hemocytes was investigated. Hemocytes were incubated with PS-NH{sub 2} suspensions in HS (1, 5 and 50 µg/mL) and the results were compared with those obtained in ASW medium. Cell functional parameters (lysosomal membrane stability, oxyradical production, phagocytosis) were evaluated, and morphological changes were investigated by TEM. The activation state of the signalling components involved in Mytilus immune response (p38 MAPK and PKC) was determined. The results show that in the presence of HS, PS-NH{sub 2} increased cellular damage and ROS production with respect to ASW medium. The effects were apparently mediated by disregulation of p38 MAPK signalling. The formation of a PS-NH{sub 2}-protein corona in HS was investigated by centrifugation, and 1D- gel electrophoresis and nano-HPLC-ESI-MS/MS. The results identified the Putative C1q domain containing protein (MgC1q6) as the only component of the PS-NH{sub 2} hard protein corona in Mytilus hemolymph. These data represent the first evidence for the formation of a NP bio-corona in aquatic organisms and underline the importance of the recognizable biological identity of NPs in physiological exposure medium when testing their potential impact environmental model organisms. Although the results obtained in vitro do not entirely reflect a realistic exposure scenario and the more complex formation of a bio-corona that is likely to occur in vivo, these data will contribute to a better understanding of the effects of NPs in marine invertebrates. - Highlights: • The effects of PS-NH2 NPs on Mytilus hemocytes were compared in serum-HS and ASW. • HS increased cellular/lysosomal damage, ROS production and p-p38MAPK levels. • NP-corona proteins in HS were isolated and identified by MS. • NP-protein coronas in biological fluids can affect NP impact in marine species.

60 APPLIED LIFE SCIENCES↗

New Insights from Legacy Seismic Data regarding Basalt Elevations and Variability on the Hanford Site

Migration of groundwater contaminants in the Gable Gap area of the Hanford Site in southeastern Washington State is strongly influenced by the distribution and permeability of basalts that lie beneath an unconfined aquifer. Locally, folding and faulting of the Columbia River Basalt associated with the Yakima fold and thrust belt followed by erosion due to the Lake Missoula floods resulted in a complex basalt surface that represents either an impermeable lower boundary to the unconfined aquifer system or localized regions of increased permeability that potentially promote communication between the unconfined aquifer system and deeper, confined aquifer systems. Paleo-channels carved into the basalt by floodwaters are thought to provide preferential flow paths for groundwater contaminants. In 2011, a seismic landstreamer campaign was carried out to image the basalt surface and produced pre-stack depth migrated p-wave reflection images. The reflection images identified two large troughs that may represent paleo-channels and several areas of possible faulting. Here, the streamer data are re-analyzed using refraction travel-time and Rayleigh wave dispersion analyses to obtain images of compressional and shear wave velocities within the suprabasalt sediment sections and the upper basalt surface. The combined interpretation of reflection and seismic velocity images shows complexity in the basalt velocity and elevation, which varies by 50 m or more within the study area. These results, along with other ongoing geophysical investigations, will be used to inform the site geologic model and potentially guide placement of future boreholes needed to quantify vertical flow between the confined and unconfined aquifers.

58 GEOSCIENCES↗

Marker-free registration of forest terrestrial laser scanner data pairs with embedded confidence metrics

Terrestrial laser scanning (TLS) has emerged as an effective tool for rapid comprehensive measurement of object structure. Registration of TLS data is an important prerequisite to overcome the limitations of occlusion. However, due to the high dissimilarity of point cloud data collected from disparate viewpoints in the forest environment, adequate marker-free registration approaches have not been developed. The majority of studies instead rely on the utilization of artificial tie points (e.g., reflective tooling balls) placed within a scene to aid in coordinate transformation. We present a technique for generating view-invariant feature descriptors that are intrinsic to the point cloud data and, thus, enable blind marker-free registration in forest environments. To overcome the limitation of initial pose estimation, we employ a voting method to blindly determine the optimal pairwise transformation parameters, without an a priori estimate of the initial sensor pose. To provide embedded error metrics, we developed a set theory framework in which a circular transformation is traversed between disjoint tie point subsets. This provides an upper estimate of the Root Mean Square Error (RMSE) confidence associated with each pairwise transformation. Output RMSE errors are commensurate with the RMSE of input tie points locations. Thus, while the mean output RMSE=16.3cm, improved results could be achieved with a more precise laser scanning system. This study 1) quantifies the RMSE of the proposed marker-free registration approach, 2) assesses the validity of embedded confidence metrics using receiver operator characteristic (ROC) curves, and 3) informs optimal sample spacing considerations for TLS data collection in New England forests. Furthermore, while the implications for rapid, accurate, and precise forest inventory are obvious, the conceptual framework outlined here could potentially be extended to built environments.

47 OTHER INSTRUMENTATION↗