Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Low-Rank Solution Methods for Stochastic Eigenvalue Problems

In this report, we study efficient solution methods for stochastic eigenvalue problems arising from discretization of self-adjoint partial differential equations with random data, where the underlying operators depend linearly on the random parameters. With the stochastic Galerkin approach, the solutions are represented as generalized polynomial chaos expansions. When these solutions can be approximated well by low-rank objects, we introduce a low-rank variant of the inverse subspace iteration algorithm for computing one or several minimal eigenvalues and corresponding eigenvectors of parameter-dependent matrices. In the algorithm, the iterates are approximated by low-rank matrices, which leads to significant cost savings. Furthermore, the algorithm is tested on two benchmark problems, a stochastic diffusion problem with some poorly separated eigenvalues, and an operator derived from a discrete stochastic Stokes problem whose minimal eigenvalue is related to the inf-sup stability constant. Numerical experiments show that the low-rank algorithm produces accurate solutions compared to the Monte Carlo method, and it uses much less computational time than the original algorithm without low-rank approximation.

97 MATHEMATICS AND COMPUTING↗

Discovery of Geographically Robust Hybrid Poplar Clones

Hybrid poplar clonal growth in the states (regions) of Minnesota (MN), Indiana (IN), Michigan (MI), and New York (NY) USA was analyzed to discover 10 geographically robust (geo-robust) clones, all P. deltoides x P. nigra (D x N) hybrids previously tested and screened in MN, that were broadly adapted across latitudinal and longitudinal ranges of 9 and 20 degrees, respectively. The clonal effect for growth explained 25 to 36 % of the total variance, 2.5–4.1 times the clone x site interaction. Clone explained 24 to 46 % of total variation in canker occurrence on two sites. Genetic gain in growth was calculated relative to commercial check clones. Genetic gain in growth of geo-robust clones exceeded that of random clones by 24 to 44 %. Geo-robust clones and the best clones on each site were not significantly different on the MN sites, but best clones outperformed geo-robust clones on the other sites by 10 to 39 % genetic gain. Geo-robust clones grew faster than commercial check clones on all but the MI site. The reduction in genetic gain for growth due to using broadly adapted clones relative to the best clones has to be compared to the additional costs and benefits of multiple breeding zones.

59 BASIC BIOLOGICAL SCIENCES↗

Fast Characterization of Inducible Regions of Atrial Fibrillation Models With Multi-Fidelity Gaussian Process Classification

Computational models of atrial fibrillation have successfully been used to predict optimal ablation sites. A critical step to assess the effect of an ablation pattern is to pace the model from different, potentially random, locations to determine whether arrhythmias can be induced in the atria. In this work, we propose to use multi-fidelity Gaussian process classification on Riemannian manifolds to efficiently determine the regions in the atria where arrhythmias are inducible. We build a probabilistic classifier that operates directly on the atrial surface. We take advantage of lower resolution models to explore the atrial surface and combine seamlessly with high-resolution models to identify regions of inducibility. We test our methodology in 9 different cases, with different levels of fibrosis and ablation treatments, totalling 1,800 high resolution and 900 low resolution simulations of atrial fibrillation. When trained with 40 samples, our multi-fidelity classifier that combines low and high resolution models, shows a balanced accuracy that is, on average, 5.7% higher than a nearest neighbor classifier. We hope that this new technique will allow faster and more precise clinical applications of computational models for atrial fibrillation. All data and code accompanying this manuscript will be made publicly available at: https://github.com/fsahli/AtrialMFclass.

59 BASIC BIOLOGICAL SCIENCES↗

Supernova Driving. IV. The Star-formation Rate of Molecular Clouds

We compute the star-formation rate (SFR) in molecular clouds (MCs) that originate ab initio in a new, higher-resolution simulation of supernova-driven turbulence. Because of the large number of well-resolved clouds with self-consistent boundary and initial conditions, we obtain a large range of cloud physical parameters with realistic statistical distributions, which is an unprecedented sample of star-forming regions to test SFR models and to interpret observational surveys. We confirm the dependence of the SFR per free-fall time, SFR{sub ff}, on the virial parameter, α {sub vir}, found in previous simulations, and compare a revised version of our turbulent fragmentation model with the numerical results. The dependences on Mach number, M, gas to magnetic pressure ratio, β, and compressive to solenoidal power ratio, χ at fixed α {sub vir} are not well constrained, because of random scatter due to time and cloud-to-cloud variations in SFR{sub ff}. We find that SFR{sub ff} in MCs can take any value in the range of 0 ≤ SFR{sub ff} ≲ 0.2, and its probability distribution peaks at a value of SFR{sub ff} ≈ 0.025, consistent with observations. The values of SFR{sub ff} and the scatter in the SFR{sub ff}–α {sub vir} relation are consistent with recent measurements in nearby MCs and in clouds near the Galactic center. Although not explicitly modeled by the theory, the scatter is consistent with the physical assumptions of our revised model and may also result in part from a lack of statistical equilibrium of the turbulence, due to the transient nature of MCs.

79 ASTRONOMY AND ASTROPHYSICS↗

Image processing of multiphase images obtained via X-ray microtomography: A review

Easier access to X-ray microtomography (μCT) facilities has provided much new insight from high-resolution imaging for various problems in porous media research. Pore space analysis with respect to functional properties usually requires segmentation of the intensity data into different classes. Image segmentation is a nontrivial problem that may have a profound impact on all subsequent image analyses. This review deals with two issues that are neglected in most of the recent studies on image segmentation: (i) focus on multiclass segmentation and (ii) detailed descriptions as to why a specific method may fail together with strategies for preventing the failure by applying suitable image enhancement prior to segmentation. In this way, the presented algorithms become very robust and are less prone to operator bias. Three different test images are examined: a synthetic image with ground-truth information, a synchrotron image of precision beads with three different fluids residing in the pore space, and a μCT image of a soil sample containing macropores, rocks, organic matter, and the soil matrix. Image blur is identified as the major cause for poor segmentation results. Other impairments of the raw data like noise, ring artifacts, and intensity variation can be removed with current image enhancement methods. Bayesian Markov random field segmentation, watershed segmentation, and converging active contours are well suited for multiclass segmentation, yet with different success to correct for partial volume effects and conserve small image features simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voronoi Meshing to Accurately Capture Geological Structure in Subsurface Simulations

Mesh generation lies at the interface of geological modeling and reservoir simulation. Highly skewed or very small grid cells may be necessary to accurately capture the geometry of geological features, but the resulting poorly scaled or small grid cells can have a substantial negative impact on simulator accuracy and speed. One way to minimize numerical errors caused by gridding complex structures is to simulate on high-quality Voronoi meshes, which reduce grid orientation effects in fluid flow. This work presents a complete methodology to create Voronoi simulation grids, model fluid flow in complex geological systems, and visualize the results. A recently developed Voronoi meshing method that can automatically generate provably good unstructured meshes that conform to input surfaces creating closed volumes is used. Initially an analytical benchmark simulation is presented to validate the quality of the meshes and simulation results and demonstrate the superiority of simulation results using Voronoi meshes over flexed-hexahedral meshes on a domain with internal features. Next, meshes are created for test structures representing four of the most common geological features in the subsurface: layering, pinch-out, an interior lens that tapers to zero thickness on all sides and a fault with offset. Two benchmark flow simulations are run for each test structure. Finally, a realistic geological example for CO 2 injection into an anticline is simulated. Three realizations of the Voronoi mesh at the same resolution are generated for the simulations. Each mesh is highly refined near the injection wells and coarse in areas of less interest. These three meshes are used to model the CO 2 plume in the subsurface as it migrates to the top of the structure and then fills downward. Simulations on the meshes with randomly generated elements inside the input volumes each give slightly different fingering patterns for the viscous-unstable buoyant gas flow. The results presented in this work show a promising step towards utilizing fully automated Voronoi meshing for subsurface flow simulations in complex geology.

58 GEOSCIENCES↗

Defining the Optimal Planning Target Volume in Image-Guided Stereotactic Radiosurgery of Brain Metastases: Results of a Randomized Trial

Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. Conclusions: SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assimilating irregularly spaced sparsely observed turbulent signals with hierarchical Bayesian reduced stochastic filters

In this paper, we consider a practical filtering approach for assimilating irregularly spaced, sparsely observed turbulent signals through a hierarchical Bayesian reduced stochastic filtering framework. The proposed hierarchical Bayesian approach consists of two steps, blending a data-driven interpolation scheme and the Mean Stochastic Model (MSM) filter. We examine the potential of using the deterministic piecewise linear interpolation scheme and the ordinary kriging scheme in interpolating irregularly spaced raw data to regularly spaced processed data and the importance of dynamical constraint (through MSM) in filtering the processed data on a numerically stiff state estimation problem. In particular, we test this approach on a two-layer quasi-geostrophic model in a two-dimensional domain with a small radius of deformation to mimic ocean turbulence. Our numerical results suggest that the dynamical constraint becomes important when the observation noise variance is large. Second, we find that the filtered estimates with ordinary kriging are superior to those with linear interpolation when observation networks are not too sparse; such robust results are found from numerical simulations with many randomly simulated irregularly spaced observation networks, various observation time intervals, and observation error variances. Third, when the observation network is very sparse, we find that both the kriging and linear interpolations are comparable.

97 MATHEMATICS AND COMPUTING↗

On a framework for generating PoD curves assisted by numerical simulations

The Probability of Detection (PoD) curve method has emerged as an important tool for the assessment of the performance of NDE techniques, a topic of particular interest to the nuclear industry where inspection qualification is very important. The conventional experimental means of generating PoD curves though, can be expensive, requiring large data sets (covering defects and test conditions), and equipment and operator time. Several methods of achieving faster estimates for PoD curves using physics-based modelling have been developed to address this problem. Numerical modelling techniques are also attractive, especially given the ever-increasing computational power available to scientists today. Here we develop procedures for obtaining PoD curves, assisted by numerical simulation and based on Bayesian statistics. Numerical simulations are performed using Finite Element analysis for factors that are assumed to be independent, random and normally distributed. PoD curves so generated are compared with experiments on austenitic stainless steel (SS) plates with artificially created notches. We examine issues affecting the PoD curve generation process including codes, standards, distribution of defect parameters and the choice of the noise threshold. We also study the assumption of normal distribution for signal response parameters and consider strategies for dealing with data that may be more complex or sparse to justify this. These topics are addressed and illustrated through the example case of generation of PoD curves for pulse-echo ultrasonic inspection of vertical surface-breaking cracks in SS plates.

36 MATERIALS SCIENCE↗

Mechanical responses of 316L stainless steel printed by wire arc additive manufacturing with different thermal histories

In this paper, 316L stainless steel walls were printed using single-bead pass and multiple-bead pass wire arc additive manufacturing (WAAM), which represent the internal basket wall and external wall of a spent nuclear fuel (SNF) canister; respectively. Scanning electron microscopy (SEM) microstructure characterization and tensile tests at room temperature (21 °C) and elevated temperature (250 °C) were performed on specimens extracted along the length and height directions of the printed walls. Results showed that grain morphology, grain angles, and retained ferrite are different between the two printed walls, which received different heat input in WAAM. The single-bead pass printed wall exhibited higher yield strength than the multiple-bead pass printed wall because of more retained ferrite and larger portion of random-high angle boundaries (RHAB) grains.

Tang, Wei↗

The ASSIST trial: Acute effects of manipulating strength exercise volume on insulin sensitivity in obese adults: A protocol for a randomized controlled, crossover, clinical trial

Type 2 diabetes mellitus is a disease in which insulin action is impaired, and an acute bout of strength exercise can improve insulin sensitivity. Current guidelines for strength exercise prescription suggest that 8 to 30 sets could be performed, although it is not known how variations in exercise volume impact insulin sensitivity. Additionally, this means an almost 4-fold difference in time commitment, which might directly impact an individual’s motivation and perceived capacity to exercise. This study will assess the acute effects of high- and low-volume strength exercise sessions on insulin sensitivity. After being thoroughly familiarized, 14 obese individuals of both sexes (>40 year old) will undergo 3 random experimental sessions, with a minimum 4-day washout period between them: a high-volume session (7 exercises, 3 sets per exercise, 21 total sets); a low-volume session (7 exercises, 1 set per exercise, 7 total sets); and a control session, where no exercise will be performed. Psychological assessments (feeling, enjoyment, and self-efficacy) will be performed after the sessions. All sessions will be held at night, and the next morning, an oral glucose tolerance test will be performed in a local laboratory, from which indexes of insulin sensitivity will be derived. We believe this study will aid in strength exercise prescription for individuals who claim not to have time to exercise or who perceive high-volume strength exercise intimidating to adhere to. This trial was prospectively registered.

60 APPLIED LIFE SCIENCES↗

THE EFFECTS OF SPATIAL SMOOTHING ON SOLAR MAGNETIC HELICITY PARAMETERS AND THE HEMISPHERIC HELICITY SIGN RULE

The hemispheric preference for negative/positive helicity to occur in the northern/southern solar hemisphere provides clues to the causes of twisted, flaring magnetic fields. Previous studies on the hemisphere rule may have been affected by seeing from atmospheric turbulence. Using Hinode /SOT-SP data spanning 2006–2013, we studied the effects of two spatial smoothing tests that imitate atmospheric seeing: noise reduction by ignoring pixel values weaker than the estimated noise threshold, and Gaussian spatial smoothing. We studied in detail the effects of atmospheric seeing on the helicity distributions across various field strengths for active regions (ARs) NOAA 11158 and NOAA 11243, in addition to studying the average helicities of 179 ARs with and without smoothing. We found that, rather than changing trends in the helicity distributions, spatial smoothing modified existing trends by reducing random noise and by regressing outliers toward the mean, or removing them altogether. Furthermore, the average helicity parameter values of the 179 ARs did not conform to the hemisphere rule: independent of smoothing, the weak-vertical-field values tended to be negative in both hemispheres, and the strong-vertical-field values tended to be positive, especially in the south. We conclude that spatial smoothing does not significantly affect the overall statistics for space-based data, and thus seeing from atmospheric turbulence seems not to have significantly affected previous studies’ ground-based results on the hemisphere rule.

79 ASTRONOMY AND ASTROPHYSICS↗

Melt extruded versus extrusion compression molded glass-polypropylene long fiber thermoplastic composites

Long fiber thermoplastic (LFT) composites are processed either with extrusion compression or fiber injection processes. The properties of LFT materials are highly influenced by processing techniques, which lead to different porosity contents, fiber length distributions, and fiber orientation distributions. It is important to understand the various LFT processing techniques and their effects on mechanical, thermal, and microscopic properties. This work considered LFT sheets processed via extrusion, which offers highly aligned fibers (referred to as “Tecnogor composites”), and LFT composites produced via extrusion compression molding (ECM), which offers a random distribution of fibers. Tecnogor composites exhibited higher flexural strength (35–65%), flexural modulus (132–172%), tensile strength (39–52%), tensile modulus (67–75%), and Izod impact resistance (195–220%) than the random LFT composites. This response was attributed to the aligned fibers in Tecnogor composites. Mathematical models including Halpin-Tsai and Lavengood-Goettler were used to predict and compare the Young’s modulus of Tecnogor and ECM composites, respectively.

mechanical testing↗

Radiographic stool quantification: an equivalence study of 484 symptomatic and asymptomatic subjects

Purpose: To determine if symptomatic patients referred for radiographic stool quantification have equivalent stool burden to asymptomatic patients. Method: This was an IRB-approved HIPAA-compliant retrospective equivalence cohort study. An a priori equivalence power calculation was performed. Consecutive abdominal radiographs performed in adult outpatients with bloating, constipation, diarrhea, or abdominal pain to assess “fecal loading” [n = 242 (fecal cohort)] were compared to those performed in asymptomatic adult outpatients to assess “renal stones” [n = 242 (renal cohort)]. Radiographs were randomized and reviewed by two blinded independent abdominal radiologists. Exclusion criteria, designed to avoid unblinding, included urinary tract calculi ≥ 0.5 cm, multiple urinary tract calculi, and ureteral stent(s). Readers scored all radiographs (n = 484) for stool burden using validated Leech criteria [scale: 0 (none) to 15 (extreme diffuse)]. Mean Leech scores and 95% confidence intervals were calculated. Multivariable generalized linear modeling was performed to adjust for baseline medication use, age, and gender. The adjusted parameter estimate was used to test for equivalence in the mean difference between cohorts using Schuirmann’s method of two one-sided t-tests. Inter-reader agreement was assessed with intraclass correlation coefficients. Results: Overall mean Leech scores for fecal [6.9 (95% CI 6.7, 7.2)] and renal [7.3 (95% CI 7.1, 7.5)] cohorts were equivalent within a margin of 0.75 (adjusted mean difference: − 0.4 [90% CI − 0.7, − 0.04]; p value = 0.02). Inter-reader agreement was good [ICC: 0.62 (95% CI 0.56, 0.68)]. Conclusion: Radiographic stool quantification produces equivalent results in symptomatic and asymptomatic adults and is of uncertain value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subgroup analysis of efficacy and safety of orantinib in combination with TACE in Japanese HCC patients in a randomized phase III trial (ORIENTAL)

A randomized, phase III trial of orantinib in combination with transcatheter arterial chemoembolization (TACE) did not prolong overall survival (OS) over placebo (ORIENTAL study). A subgroup analysis was conducted to evaluate the efficacy and safety of orantinib in Japanese patients enrolled in the ORIENTAL study. The data of Japanese patients from this study were analyzed. The overall survival (OS), time to progression (TTP), and time to TACE failure (TTTF) were compared between orantinib and placebo arms using stratified log-rank test. Since TTTF in patients with Barcelona Clinic Liver Cancer stage B (BCLC-B) showed favor outcome in this study, the OS and TTTF according to BCLC staging system were also analyzed. The subgroup analysis consisted of 219 and 213 patients in the orantinib and placebo arms. Median OS was 32.5 vs 33.0 months (p = 0.906), median TTP was 4.7 vs 3.1 months (p = 0.011), and median TTTF was 25.3 vs 18.2 months (p = 0.160) in the orantinib and placebo groups, respectively. Patients with BCLC-B in the orantinib and placebo groups showed a median OS of 33.7 and 30.1 months, respectively (p = 0.260), while the corresponding median TTTF were 25.3 and 14.0 months (p = 0.125). The Japanese population safety profile was similar to all over population in the ORIENTAL study. No significant differences were observed in the OS and TTTF though the TTP was significantly improved in the orantinib arm. The OS and TTTF showed a tendency to be prolonged following orantinib treatment of Japanese HCC patients with BCLC-B in the ORIENTAL study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-dimensional dataset for two-phase instability in low pressure natural circulation based on direct transient local measurement

Thermal hydraulic instability can challenge the control and the safety of nuclear reactors. This experimental research captures and investigates the instability in a low-pressure (1–10 atmospheres) natural circulation loop with an adiabatic chimney installed above the heated section. Direct transient local measurement of two-phase flow is performed at multiple axial locations along the flow channel with thermocouples and conductivity probes traversed by customized high-precision mechanisms. Based on the periodicity of oscillations, a post-processing method is proposed to align the data captured non-simultaneously to reconstruct the instability behavior in one representative period. The averaging operation over multiple oscillation cycles is performed to reduce the random errors. Cyclic phenomena are clearly demonstrated by the post-processed data, and rapid void fraction change induced by the flashing is observed to be significant in the driving mechanism for low pressure oscillations. Parametric effects of inlet subcooling, heat flux, inlet flow restriction and system pressure are studied within the experiment range, and qualitative results are explained and compared with existing literature. The ratio between the oscillation period and the travelling time of the fluid particle through the test section is compared with the theoretical value for the density wave oscillation. The new dataset contains directly measured transient multi-dimensional two-phase data along the flow channel for natural circulation under density wave oscillations. The generated dataset is valuable for the validation of system analysis codes and CFD codes in the simulation of natural circulation phenomena and dynamic two-phase flow.

42 ENGINEERING↗

Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P<.01). Late skin toxicity was no worse than grade 2 in either group, without significant differences between the 2 groups. In the ipsilateral breast, the areas that received the highest doses (ie, the boost or quadrant) showed the greatest loss of elasticity. WBI resulted in a greater loss of elasticity in the high-dose area compared with APBI (P<.05). Physician assessment showed that >75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with conventional WBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrogen embrittlement of Zircaloy-4 fabricated by ultrasonic additive manufacturing

Ultrasonic additive manufacturing (UAM) was successfully applied to the zirconium material system to create a planar geometry. Following fabrication, SS-J3 type tensile specimens of the UAM and wrought Zircaloy-4 with a nominal gage section of 5×1.2×0.75 mm were machined for hydriding studies and mechanical testing. The SS-J3 type tensile specimens were gas-charged with hydrogen using a custom system that precisely controls hydrogen gas flow rate, hydrogen partial pressure, and temperature. To avoid altering the UAM material, the maximum process temperature was limited to 550°C. Using different initial hydrogen gas pressures and flow rates, various hydrogen contents (70–1755 wppm) were achieved for Zircaloy-4 specimens. Tensile testing shows that, regardless of hydrogen content, all UAM specimens measured yield strengths in the range of 557±16 MPa and ultimate tensile strengths of 660±4MPa. However, total elongation clearly decreased as a function of increasing hydrogen content. Further, at the lowest hydrogen content, the total plastic elongation measured 21.5%, and this value decreased to less than 2% when the hydrogen content was increased to 1000 wppm. Cross-sectional optical microscopy images revealed that the hydride distributions are randomly oriented. For the low hydrogen content specimen, these randomly distributed hydrides are isolated from each other. A sandwiched structure, consisting of high-density and low-density layers, was also observed for the specimens with hydrogen content between 200 and 400 wppm. As the hydrogen content increases, the hydrides diffuse into the low-density hydride layers to form a network across the whole specimen. Although the tensile properties of UAM and wrought Zircaloy-4 exhibit the same behavior with increasing hydrogen content, the distinctions in grain orientations led to differences in the hydride orientations at low and intermediate hydrogen concentrations.

36 MATERIALS SCIENCE↗