Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Finite Volume Based Computer Program for Ground Source Heat Pump System

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled "Finite Volume Based Computer Program for Ground Source Heat Pump Systems." The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time.

15 GEOTHERMAL ENERGY↗

Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

15 GEOTHERMAL ENERGY↗

High-efficiency Commercial Cold Climate Heat Pump

United Technologies Research Center (UTRC) proposed in 2012 to design, develop and demonstrate an air-source 10TR high-efficiency commercial cold climate heat pump (CCCHP). The proposed heat pump would be scalable beyond 40TR, cost effective with a simple payback of < 3 years upon commercialization and would reduce annual electricity use for building space heating in cold climates by at least 20%. This would represent an annual savings of $2.3 billion and a 20% displacement of total greenhouse gases generated upon full commercialization. The primary objective was to develop a highly integrated system that shall meet or exceed DOE capacity and efficiency targets at key conditions and is scalable, cost-effective and simple relative to the state-of-the-art. Specifically, the goal of the project was to design, develop and demonstrate a CCCHP that exceeds DOE capacity degradation requirements at +17F and -13F conditions (0 and <15% degradation vs. 10 and 25% DOE requirements, respectively) while meeting or exceeding DOE capacity and system efficiency requirements at all other conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Mini-split heat pumps are being proposed as a new retrofit option to replace resistance heating in the Pacific Northwest. NREL has previously developed a field test protocol for mini-split systems to ensure consistent results from field tests. This report focuses on the development of detailed system performance maps for mini-split heat pumps so that the potential benefits of mini-split systems can be accurately analyzed for different climate regions and housing types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Air-Conditioner and Heat Pump Modeling [Slides]

This presentation describes a new approach to modeling residential air conditioners and heat pumps, which allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted “behind-the-scenes” without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Heat Pump System for New Student Housing Project at the University at Albany Main Campus

University at Albany successfully designed, constructed and is operating a new student housing building that utilizes ground source heat pump (GSHP) for heating and cooling the entire 191,500SF building. The installed system consists of a well field with 150 bores, 450 feet deep and (189) terminal heat pump units for a total capacity of 358 Tons cooling and 4,300 MBtu/h heating. The building opened in Fall 2012. The annual energy use and cost intensity of the building, after the changes made during the first 2 years’ of operation is 57kBtu/SF/Year and $1.30/SF/Year respectively. This is approximately 50% lower than the other residential quads on campus, despite the fact that the quads are not air-conditioned. The total project cost from design through 3-years of operations is approximately $6 Million, out of which $5.7 Million is for construction of the GSHP system including the well field. The University received a $2.78 Million grant from the Department of Energy. The estimated utility cost savings, compared to a baseline building with conventional HVAC system, is approximately $185,000. The estimated simple payback, after grant incentives, is 15 years. Additionally, the project has created 8.5FTE equivalent jobs.

15 GEOTHERMAL ENERGY↗

Two 175 ton geothermal chiller heat pumps for leed platinum building technology demonstration project. Operation data, data collection and marketing

The activities funded by this grant helped educate and inform approximately six thousand individuals who participated in guided tours of the geothermal chiller plant at Johnson Controls Corporate Headquarters in Glendale, Wisconsin over the three year term of the project. In addition to those who took the formal tour, thousands more were exposed to hands-on learning at the self-service video kiosks located in the headquarters building and augmented reality tablet app that allowed for self-guided tours. The tours, video, and app focused on the advantages of geothermal heat pump chillers, including energy savings and environmental impact. The overall tour and collateral also demonstrated the practical application of this technology and how it can be designed into a system that includes many other sustainable technologies without sacrificing comfort or health of building occupants Among tour participants were nearly 1,000 individuals, representing 130 organizations identified as potential purchasers of geothermal heat pump chillers. In addition to these commercial clients, tours were well attended by engineering, facilities, and business trade groups. This has also been a popular tour for groups from Universities around the Midwest and K-12 schools from Wisconsin and Northern Illinois A sequence of operations was put into place to control the chillers and they have been tuned and maintained to optimize the benefit from the geothermal water loop. Data on incoming and outgoing water temperature and flow from the geothermal field was logged and sent to DOE monthly during the grant period to demonstrate energy savings.

15 GEOTHERMAL ENERGY↗

Human Health Science Building Geothermal Heat Pump Systems

The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

15 GEOTHERMAL ENERGY↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aquifer pumping test report for the burn site groundwater area of concern

The Aquifer Pumping Test Report for the Burn Site Groundwater (BSG) Area of Concern is being submitted by National Technology and Engineering Solutions of Sandia, LLC and the U.S. Department of Energy (DOE)/National Nuclear Security Administration to describe the results of the aquifer pumping test program and related field activities that were completed at the BSG Area of Concern. This report summarizes the results of the field work and data analyses, and is being submitted to the New Mexico Environment Department (NMED) Hazardous Waste Bureau, as required by the April 14, 2016 letter, Summary of Agreements and Proposed Milestones Pursuant to the Meeting of July 20, 2015, (NMED April 2016).

54 ENVIRONMENTAL SCIENCES↗

High-Efficiency Solid State Heat Pump Module

The baseline heat pumping technology today is dominated by vapor compression refrigeration cycle that involves use of global warming potential fluids (e.g. hydrofluorocarbons HFC). Current regulations (e.g. 2016 Kigali agreement) and market needs are driving HVAC&R related building, automotive and aerospace industries to safe, compact and cost-effective systems with low global warming potential (GWP) footprint (i.e. direct GWP impact) and higher efficiencies (i.e. indirect GWP impact) and low life cycle cost. Among the solid-state technology options, electrocaloric heat pumping (ECHP) technology has potential to be more efficient, quiet and compact than vapor compression systems. However, electrocaloric technology is still at low maturity, as expressed by standard technology readiness level (TRL) assessments and hence was the focus of the current effort. During the current research effort, UTRC proved feasibility (TRL2/3) of the direct-air ECHP concept by demonstrating cooling of ambient air by 8.4°C (under no load conditions) in a laboratory environment. To the team’s knowledge this is the largest direct air cooling demonstration using electrocaloric technology. The technology was matured from lab-scale dime-sized materials to module-scale dimensions and further demonstrated the feasibility of integrating these electrocaloric materials into modules for providing direct-air cooling. The use of inexpensive polymer-based materials validates the economic feasibility of the proposed technology. Future effort is required to further mature this promising technology to TRL 4/5 demonstrating module and system performance at full capacity and efficiency. Maturity to beyond TRL4/5 could be done with limited potential field trials. Successful field trials can pave the way for commercialization. At full commercialization, electrocaloric based heating and cooling technologies have the potential to enable annual energy savings upwards of a quadrillion BTUs and reduction of 10s of million metric tons/yr of Green-House Gas (GHG) emissions in the US, leapfrogging emerging technologies and disrupting traditional cooling and heating systems in residential and commercial HVAC applications and enabling new applications. This would result in reduction of energy imports, greenhouse gas (GHG) emissions and help create US jobs in this new technical area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Toughness Cermets for Molten Salt Pumps

The DOE seeks major reductions in the cost of concentrated solar power (CSP) to achieve subsidy-free, cost-competitive solar power by 2020. A significant step in achieving lower cost is the evolution to higher temperature operation. Molten chloride salts, and in particular KCl-MgCl2 currently appear to be to be the materials of choice to operate at these temperatures. The high working temperature and corrosive properties of these salts present an aggressive environment for CSP components. Valves seat and seals, bearings and impellers for pumps have additional requirements because of the dynamic mechanical loads that these components must survive. Alloys do not have good compatibility with salt and are expensive. Ceramic composites are difficult to form. This project offers a proof of concept for the use of ceramic, metal matrix nanocomposite materials to enable the economical construction and operation of molten salt pumps.

14 SOLAR ENERGY↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016

This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strategies and Approaches for Developing Hands-On Training for Cold Climate Heat Pumps

The International Center for Appropriate and Sustainable Technology (ICAST) is in the process of implementing a program funded by the US Department of Energy (DOE) in which they are providing cold climate heat pump (CCHP) curriculum and training to HVAC workers, ranging from entry to experienced levels. They have coordinated with Santa Fe Community College (SFCC) to develop online curricula, and through their involvement with the DOE Better Buildings Workforce Accelerator, they requested technical assistance from the National Renewable Energy Laboratory (NREL) to help them develop programs that incorporate hands-on and on-the-job skills training and job placement services in coordination with local employers. This report offers a step-by step-overview of the process for developing a new workforce development and hands-on training program in a new region, outlining practices to help understand the market, and to effectively recruit, train, and connect people to HVAC jobs installing cold climate heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗