Risk Management of NPP Incidents

A diagnostic model for managing the risk of NPP incidents attending different irregularities of equipment operation is examined for the example of the oil delivery system of the main circulation pump. The model includes the construction of a graph of the operation of the oil system and ranking in order to obtain indices of priority for monitoring information flow that reflect the actuation probability of each form of protection. The results of the analysis can used as input data for predicting the duration of a stable state of a technological system in the course of operation on the basis of stochastic extrapolation of the parameters by means of single-channel queuing systems with finite storage – technological protection and blocking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

Microgravity fluid management in two-phase thermal systems

Initial studies have indicated that in comparison to an all liquid single phase system, a two-phase liquid/vapor thermal control system requires significantly lower pumping power, demonstrates more isothermal control characteristics, and allows greater operational flexibility in heat load placement. As a function of JSC's Work Package responsibility for thermal management of space station equipment external to the pressurized modules, prototype development programs were initiated on the Two-Phase Thermal Bus System (TBS) and the Space Erectable Radiator System (SERS). JSC currently has several programs underway to enhance the understanding of two-phase fluid flow characteristics. The objective of one of these programs (sponsored by the Microgravity Science and Applications Division at NASA-Headquarters) is to design, fabricate, and fly a two-phase flow regime mapping experiment in the Shuttle vehicle mid-deck. Another program, sponsored by OAST, involves the testing of a two-phase thermal transport loop aboard the KC-135 reduced gravity aircraft to identify system implications of pressure drop variation as a function of the flow quality and flow regime present in a representative thermal system.

Parish, Richard C.↗

Operational processing and cloud boundary detection from micro pulse lidar data

Micro Pulse Lidar (MPL) was developed at NASA Goddard Space Flight Center (GSFC) as the result of research on space-borne lidar techniques. It was designed to provide continuous, unattended observations of all significant atmospheric cloud and aerosol structure with a rugged, compact system design and the benefit of eye safety (Spinhirne 1993). The significant eye safety feature is achieved by using low pulse energies and high pulse repetition rates compared to standard lidar systems. MPL systems use a diode pumped 10 microj, 2500 Hz doubled Nd:YLF laser. In addition, a solid state Geiger mode avalanche photo diode (GAPD) photon counting detector is used allowing for quantum efficiencies approaching 70%. Other design features have previously been noted by Spinhirne (1995). Though a commercially available instrument, with nearly 20 systems operating around the world, the most extensive MPL work has come from those operated by the Atmospheric Radiation Measurement (ARM) (Stokes and Schwartz 1994) program. The diverse ability of the instrument relating to the measurement of basic cloud macrophysical structure and both cloud and aerosol radiative properties well suits the ARM research philosophy. MPL data can be used to yield many parameters including cloud boundary heights to the limit of signal attenuation, cloud scattering cross sections and optical thicknesses, planetary boundary layer heights and aerosol scattering profiles, including those into the stratosphere in nighttime cases (Hlavka et al 1996). System vertical resolution ranges from 30 m to 300 m (i.e. high and low resolution respectively) depending on system design. The lidar research group at GSFC plays an advisory role in the operation, calibration and maintenance of NASA and ARM owned MPL systems. Over the past three years, processing software and system correction techniques have been developed in anticipation of the increasing population of systems amongst the community. Datasets produced by three ARM-owned systems have served as the basis for this development. With two operating at the southern Great Plains Cloud and Radiation Testbed Site (SGP CART) since December 1993 and another at the Manus Island Atmospheric Radiation and Cloud Station (TWP ARCS) location in the tropical western Pacific since February 1997, the ARM archive contains over 4 years of observations. In addition, high resolution systems planning to come on-line at the North Slope, AK CART shortly with another scheduled to follow at the TWP ARCS-II will diversify this archive with more extensive observations.

Campbell, James R.↗

UTEMPRA - Unitary Thermal Energy Management for Propulsion Range Augmentation

Key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10 degrees C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor), (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

33 ADVANCED PROPULSION SYSTEMS↗

A System Level Mass and Energy Calculation for a Temperature Swing Adsorption Pump Used for In-Situ Resource Utilization (ISRU) on Mars

Mars ISRU converts atmospheric CO2 to generate O2 and CH4. Reduces launch mass, thus mission cost. Increases mission duration and independence. CO2 acquisition system must: a) Reliably extract CO2 over the varying Martian environment. 1) approx. 0.67-0.93 kPa pressure and 2) 125 C to 40 C. b) Provide and compress high purity gas to chemical plants. 1) Separate N2, Ar2, etc. from approx. 95% CO2 atmosphere and 2) Current pressure targets: 50 kPa-500 kPa.

Propellants↗

Repowering Coal Plants as Pumped Thermal Energy Storage

This conference presentation presents the results from a DOE FE funded study on the integration of a Malta Pumped Heat Energy Storage system with a retiring coal-fired power plant, and the economic benefits to the asset owner and the local community.

20 FOSSIL-FUELED POWER PLANTS↗

High Performance Cold Climate Heat Pump (CCHP) – Final Report

In the U. S., there are approximately 2.6 million dwellings that use electricity for heating in very cold and cold regions with an annual energy consumption of 0.16 quads. A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (> 70% compared to strip heating). It can result in an annual primary energy savings of 0.1 Quads when fully deployed, which is equivalent to 5.9 million tons of annual CO2 emissions reduction. The outcome of this project is the development of a split system, cold climate heat pump (CCHP) providing 36,000 Btu/hr (10.6 kW) heating capacity with a COP > 4.0 (at the 47°F (8.3°C) AHRI rating condition) and maximum efficiency degradation of 50% and capacity loss of 25% at -13°F (-25°C) ambient conditions. Between 2012 and 2015, Oak Ridge National Laboratory (ORNL) and Emerson Climate Technologies engaged in a Cooperative Research and Development Agreement (CRADA) to develop a high efficiency, cold climate heat pump for the US residential market. We went through an exhaustive technologies survey to select energy efficient and cost-effective components. We conducted in-depth engineering design and building energy modeling, based on the ORNL Heat Pump Design Model (HPDM) and EnergyPlus, by which we made the final choices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid Metal Pump Technologies for Nuclear Surface Power

Multiple liquid metal pump options are reviewed for the purpose of determining the technologies that are best suited for inclusion in a nuclear reactor thermal simulator intended to test prototypical space nuclear system components. Conduction, induction, and thermoelectric electromagnetic pumps are evaluated based on their performance characteristics and the technical issues associated incorporation into a reactor system. The thermoelectric electromagnetic pump is recommended for inclusion in the present system based on favorable quantitative and qualitative measures relative to the other options under consideration.

Polzin, Kurt A.↗

Quantization of the Higher Berry Curvature and the Higher Thouless Pump

Here, we show that for families of 1d lattice systems in an invertible phase, the cohomology class of the higher Berry curvature can be refined to an integral degree-3 class on the parameter space. Similarly, for families of U(1)-invariant 2d lattice systems in an invertible phase, the higher Thouless pump can be refined to an integral degree-2 class on the parameter space. We show that the 2d Thouless pump can be identified with an excess Berry curvature of a flux insertion.

97 MATHEMATICS AND COMPUTING↗

Microfluidic pumping through miniaturized channels driven by ultra-high frequency surface acoustic waves

Surface acoustic waves (SAWs) are an effective means to pump fluids through microchannel arrays within fully portable systems. The SAW-driven acoustic counterflow pumping process relies on a cascade phenomenon consisting of SAW transmission through the microchannel, SAW-driven fluid atomization, and subsequent coalescence. Here, we investigate miniaturization of device design, and study both SAW transmission through microchannels and the onset of SAW-driven atomization up to the ultra-high-frequency regime. Within the frequency range from 47.8 MHz to 754 MHz, we show that the acoustic power required to initiate SAW atomization remains constant, while transmission through microchannels is most effective when the channel widths w ≳ 10 λ, where λ is the SAW wavelength. By exploiting the enhanced SAW transmission through narrower channels at ultra-high frequencies, we discuss the relevant frequency-dependent length scales and demonstrate the scaling down of internal flow patterns and discuss their impact on device miniaturization strategies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced high-temperature electromagnetic pump

Three phase helical, electromagnetic induction pump for use as boiler feed pump in potassium Rankine-cycle power system is described. Techniques for fabricating components of pump are discussed. Specifications of pump are analyzed.

Gahan, J. W.↗

Experimental findings from zero-tank net positive suction head operation of the J-2 hydrogen pump

The results of a series of liquid hydrogen turbopump tests to demonstrate the feasibility of zero-tank net positive suction head are presented. A J-2 engine hydrogen pump and S-IVB stage fuel feed system were used for this investigation. The pump was operated at flows and speeds equivalent to normal J-2 engine operating conditions and at hydrogen bulk temperatures between 39 and 45 R. These tests show zero-tank not positive suction head to be a realistic operating mode that should be considered for future applications.

Stinson, H. P.↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

Photonic tunneling effect between two coupled single-atom laser cavities imbedded within a photonic-crystal platform

In this paper we investigate the photonic tunneling effect between two coupled one-atom laser cavities. The physical system consists of two coupled photonic crystal microcavities and each cavity contains a coherently pumped two-level atom. The dynamics of the system can be described by the master equation in terms of the reduced density operator. It is shown that the photonic tunneling behavior depends on certain physical conditions of the system. In the absence of the pumping field and without dissipations, the coherent photon number imbalance between two cavities exhibits the alternating-current Josephson effect. However, when the pumping effect and losses of the system are taken into account, the mean photon number imbalance displays a damped oscillation. In addition, the influence of tunneling amplitude and photonic band-gap structure on the oscillations is also studied. The research gives a further insight into the correlated dynamics of two coupled one-atom laser systems and provides an idea for constructing novel photon tunnel devises.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Factors reducing the efficiency of ytterbium fibre lasers and amplifiers operating near 0.98 μm

We have studied the factors that reduce the efficiency of cladding-pumped ytterbium fibre lasers and amplifiers operating in the spectral range around a wavelength of 0.98 μm. It has been shown that the core of the active fibre being not single-mode leads to accelerated development of amplified spontaneous luminescence around λ = 1.03 μm, which reduces the highest possible amplifier efficiency. We have examined the effect of spontaneous luminescence propagating in the first reflective cladding. It has been shown theoretically that the pump-to-signal conversion efficiency is highest when the ratio of the core and cladding diameters in a multimode active fibre lies in the range 0.7 – 1. We have fabricated and characterised an optical fibre with a core-to-cladding diameter ratio of 0.76 (core and cladding diameters of 95 and 125 μm, respectively), which allowed a pump conversion efficiency of 66 % to be reached, a record level for cladding-pumped ytterbium fibre laser systems emitting near 0.98 μm. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System design package for a solar heating and cooling system installed at Akron, Ohio

Information used to evaluate the design of a solar heating, cooling, and domestic hot water system is given. A conventional heat pump provides summer cooling items as the design data brochure, system performance specification, system hazard analysis, spare parts list, and detailed design drawings. A solar system is installed in a single-family dwelling at Akron, Ohio, and at Duffield, Virginia.

Source record↗