Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Precision Projector Laboratory: Detector Characterization with an Astronomical Emulation Testbed

As astronomical observations benefit from improved sensitivity, the effectiveness of scientific programs is becoming limited by systematics that often originate in poorly understood image sensor behavior. Traditional, bottom-up detector characterization methods provide one way to model underlying detector physics, and generate ever more faithful numerical simulations, but this approach is vulnerable to preconceptions and over-simplification. The alternative top-down approach is laboratory emulation, which enables observation, calibration, and analysis scenarios to be tested without relying on a complete understanding of the underlying physics. This complements detector characterization and simulation efforts by testing their validity. We describe a laboratory facility and experimental testbed that supports the emulation of a wide range of mission concepts such as gravitational weak lensing measurements by WFIRST and high precision spectrophotometry of transiting exoplanets by JWST. An Offner relay projects readily customizable "scenes" (e.g. stars, galaxies, spectra) with very low optical aberration over the full area of a typical optical or near infrared image sensor. f/8 and slower focal ratios may be selected, spanning those of most proposed space missions and approximating the point spread function (PSF) size of seeing limited ground based surveys. Diffraction limited PSFs are projected over a wide field of view and wavelength range to deliver highly predictable image patterns down to sub-pixel scales with stable intensity and fine motion control. The testbed enables realistic validation of detector performance on science-like images, which aids mission design and survey strategy, as well as targeted investigations of various detector effects.

Seshadri, Suresh↗

Position-Sensitive Detector with GaAs photocathode and high time resolution

The Position-Sensitive Detector (PSD) on base of GaAs photocathode and microchannel plate set has been developed. PSD consists of thick semi-conductor photocathode with quantum efficiency about 48% in the range of 4000-7500 A, two micro-channel plates, and 16-electrode collector. The detector has spatial resolution of 20-40 microns for about 5{center_dot}10{sup 2} pixels, time resolution of 1 {mu}s and effective sensitivity up to 35%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗

ALICE inner tracking system readout electronics prototype testing with the CERN "Giga Bit Transceiver''

The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.

47 OTHER INSTRUMENTATION↗

The LCLS variable-energy hard X-ray single-shot spectrometer

The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10 -5 or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

Rich, David↗

Accuracy of measurement of star images on a pixel array

Algorithms are developed for predicting the accuracy with which the brightness of a star can be determined from its image on a digital detector array, as a function of the brightness of the background. The assumption is made that a known profile is being fitted by least squares. The two profiles used correspond to ST images and to ground-based observations. The first result is an approximate rule of thumb for equivalent noise area. More rigorous results are then given in tabular form. The size of the pixels, relative to the image size, is taken into account. Astronometric accuracy is also discussed briefly; the error, relative to image size, is very similar to the photometric error relative to brightness.

King, I. R.↗

Development of a Precision Scanning Optical Pulser for Low-Temperature Particle Detectors

Gamma-ray spectroscopy using low-temperature microcalorimeter arrays has demonstrated breakthrough energy resolution, establishing an important new technique for the precise characterization of radioactive samples. However, the extraordinary dynamic range of these pixels, spanning tens of electronvolts to hundreds of kiloelectronvolts, places stringent requirements on the calibration accuracy of each pixel. In this paper, we describe the design, development, and initial reflectivity-map testing of a new optical pulser intended for the precise determination of energy calibrations of microcalorimeter pixels and pixel arrays. A high-resolution XYZ scanner combined with 3 K optics achieving a 3-μm focused spot permit in situ imaging and precise placement of the energy deposition on the detector. Lastly, absolute absorbed power can be calibrated via a precision measurement of detector thermal stand-off.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting THz Camera with GaAs‐JFET Cryogenic Readout Electronics

We describe the development of large format array of superconducting tunnel junction detectors that is readout by SONY GaAs‐JFET cryogenic integrated circuits. High quality SIS photon detectors have high dynamic impedance that can be readout by low gate leakage GaAs‐JFET circuits. Our imaging array design, with niobium SIS photon detectors and GaAs‐JFET cryogenics electronics, uses integrating amplifiers, multiplexers and shift‐registers to readout large number of pixels that is similar to CMOS digital cameras. We have designed and fabricated GaAs‐JFET cryogenic integrated circuits, such as AC‐coupled capacitive trans‐impedance amplifier, multiplexers with sample‐and‐holds and shift‐registers, for 32‐channel readout module. The Advanced Technology Center of National Astronomical Observatory of Japan have started extensive development program for large format array of SIS photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

A Compact, Modular Superconducting Bolometer Array Package

We have designed a detector package to house a superconducting bolometer array, SQUID multiplexers, bias and integration circuitry, optical filtering, electrical connectors, and thermal/mechanical interfaces. This package has been used successfully in the GISMO 2mm camera, a 128-pixel camera operating at a base temperature of 270mK. Operation at lower temperatures is allowed by providing direct heat sinking to the SQUIDS and bias resistors, which generate the bulk of the dissipation in the package. Standard electrical connectors provide reliable contact while enabling quick installation and removal of the package. Careful design has gone into the compensation for differing thermal expansions, the need for heat sinking of the bolometer array, and the placement of magnetic shielding in critical areas. In this presentation, we detail the design and performance of this detector package and describe its scalability to 1280- pixel arrays in the near future.

Benford, Dominic J.↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Focal-plane detector system for the KATRIN experiment

Here, the local plane detector system for the KArlsiuhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high vacuum system, a high vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system, It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral characterisation of aperiodic normal-incidence Sb/B{sub 4}C multilayer mirrors for the λ < 124 Å range

Three broadband aperiodic Sb/B{sub 4}C multilayer mirrors were synthesised for the purposes of soft X-ray optics and spectroscopy in the wavelength range beyond the L-edge of Si (λ < 124 Å), and their reflection spectra were measured. The multilayer structures were optimised for maximum uniform reflectivity in the ranges 100 – 120 Å, 95 – 105 Å and 90 – 100 Å. The reflection spectra were recorded using a laboratory laser-plasma radiation source and an electronic detector with a 2D spatial resolution (a CCD matrix with 13 × 13 μm sized pixels). The experimental spectra are compared with theoretical calculations. The effect of lower antimony and B{sub 4}C layer densities on the reflection spectra is discussed. (invited paper)

36 MATERIALS SCIENCE↗

Argonne Pixel Tracking Telescope at the Fermilab Test Beam Facility

The Argonne Pixel Tracking Telescope is installed at the Fermilab Test Beam Facility. The telescope consists of six planar n + -in-n silicon sensors with a pixel size of 250 × 50 μm 2 . The instrumentation of the telescope is described including the electrical and mechanical setups. A 120 GeV proton beam is used to evaluate the telescope performance using criteria such as cluster size, pixel tracking efficiency, and spatial resolution. The spatial resolution of the telescope is measured to be 72 μm × 13 μm and is consistent with the resolution determined from the simulation. In conclusion, this telescope will be used to test the performance of the various silicon pixel technology as well as to study the effects and the performance of the detectors after being irradiated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction and calibration of atmospheric impact observations in GOES GLM data

The Earth's atmosphere is impacted daily by both meteoroids and artificial objects. Calibrated observations of the emitted light at sufficiently high sampling rates can enable or improve the estimation of impactor attributes such as size, cohesion, trajectory, and composition, but are difficult to obtain owing to the unpredictability, brevity, and high dynamic (brightness) range of impacts. Ground-based camera systems have successfully monitored small regions of the atmosphere at video frame rates and with limited radiometric capabilities, but most impacts occur over the 70% of the Earth's surface covered by water and are therefore missed by these networks. The Geostationary Lightning Mapper (GLM) instruments aboard Geostationary Operational Environmental Satellites 16 and 17 provide near-hemispherical coverage at 500 frames per second. These data have been shown to contain the signatures of many independently confirmed impacts, often from both viewing angles simultaneously, and constitute an observational resource that is currently unparalleled in the public domain. NASA's Asteroid Threat Assessment Project has implemented an automated impact detection pipeline that processes data from GLM daily. Given a detected impact, the GLM data contain a wealth of information for use in quantitative follow-up analyses. However, impact events differ from lightning in ways that violate key assumptions built into GLM's design. The result is that GLM's onboard processing introduces errors into pixel observations of impact events and the calibrated energies near the periphery of the detector may be substantially overestimated. We present methods for mitigating these and other issues to produce a data product more suitable for impact analyses than the existing GLM lightning product.

58 GEOSCIENCES↗