Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twin Model for Advanced Manufacture of a Rotating Detonation Engine Injector

A digital twin material model (DTMM) of an additive manufacturing (AM) process was created to advance the state of the art in rotating detonation engine (RDE) injector design. Current RDE injectors are designed with large pressure drops, enabling a stable and repeatable combustion process. However, this comes at the cost of system efficiency. For the technology to transition to commercial fossil-based power generation, it is important to develop injectors with reduced flow losses. Low-loss injectors are difficult to design and manufacture with conventional manufacturing techniques. AM enables new design options, but the AM manufacturing process must be thoroughly understood to result in a robust design. A DTMM provides the necessary insight by defining the cause-effect relationships between process parameters, microstructure features, and properties. Therefore, a DTMM to support the design and manufacturing process was developed and applied to the design of a new additively manufactured low-loss injector. The injector combustion behavior was characterized through hot-fire tests, and mechanical performance was compared to the DTMM predictions. The two project goals were the successful development of the DTMM and the demonstration of an improved RDE injector design. The RDE injector design and DTMM developments occurred on parallel but dependent paths. The injector was designed to reduce pressure drop by increasing the cross-sectional flow area ratio between the injector air passages and the combustor annulus. This resulted in less structural material, raising the concern that thin members would be susceptible to high-cycle fatigue (HCF) under the periodic loading inherent to an RDE. It was most important for the DTMM to predict behavior in these features; therefore, the injector design concept guided the material thicknesses used in fatigue tests. The DTMM development started by manufacturing a series of coupons over the range of possible AM process variations. A design-of-experiment approach was used to select which process variable combinations gave the most efficient coverage relevant to the injector design space. The microstructure in each of these coupons was characterized, and then computational methods were used to create a numerical model of the correlation between process variables and microstructure. Next, a set of HCF samples were tested to calibrate existing models that map microstructure to HCF performance. Together, these two links formed the DTMM that calculates HCF behavior from AM process variables. Two injector prototypes were additively manufactured. The first injector design strategy aggressively pursued low-loss performance by substantially increasing the oxidizer flow area. The combination of manufacturing lead times and the fatigue testing schedule meant that the DTMM was not available when building this first prototype. Therefore, its process parameters were chosen based on a manual review of the available coupon data. This prototype was built successfully and evaluated in 58 combustion tests. Sustained detonation was achieved with remarkably reduced pressure loss, and some tests even displayed pressure loss characteristics similar to conventional gas turbine combustors. This achieved the project goal of improving RDE injector design. The second injector was manufactured according to the optimized parameters predicted by the DTMM. The flow area modifications of this injector were less aggressive than the first injector since demonstrating low pressure loss was not an objective of the second hot-fire test series. Rather, the test objective was to cause high cycle fatigue failure in the part due to periodic loading from the rotating detonation wave. The observed number of cycles to failure was to be compared to the number predicted by the DTMM and thereby assess the utility of the DTMM in component design. However, the required level of vibration was not obtained during combustion. Therefore, high cycle fatigue was not experienced in the hot-fire tests of the second injector. Fatigue data was obtained by further testing the second injector in a conventional HCF test apparatus. The injector demonstrated HCF strength above the DTMM prediction. In fact, it did not fail and testing was only discontinued due to reaching the end of the period of performance. This points to some success in the project’s primary goal of successfully developing and applying the DTMM to a component design. Implementing the DTMM recommendations for optimal processing parameters led to a part with acceptable properties. The DTMM was also shown to be an efficient correlator of data and to provide insight into the relationship between process settings, microstructure, and property performance. However, the failure of the DTMM prediction to match the experimental result of the injector fatigue test also points to the need to include significantly more data in the model development. In this project, coupons made with identical processing parameters exhibited drastically different properties from each other and from the injector part, which clearly influences the accuracy of a model that predicts performance based on parameters. Uncertainties in the build process must be quantified to develop more robust models. A denser and broader matrix of coupon process and geometry variations, several repeated builds of every point, more in-situ build process measurements, and direct observation of tensile and HCF sample microstructure (as opposed to separate microstructure specimens) are recommendations to improve future AM modeling efforts.

20 FOSSIL-FUELED POWER PLANTS↗

Imagery Applications for Advanced Event Analytics (WBS 24.3.1.3.3-IDC FY202 Final Project Report)

Accurate event locations and replicability of location analyses are essential for assessing the nature of an event, its context, ambient site conditions, and proximity to relevant facilities and infrastructure. Additionally, accurate event locations provide valuable information that reduce uncertainties, improve confidence in event analyses, and inform in-field verification activities. However, event location/relocation and replicability are difficult due to a number of factors, including spatially-sparse network coverage in some areas of the globe and variability in seismic data processing. This team proposed that the incorporation of high-fidelity imagery as a data backbone to the analytical assessment of a suspected underground explosion and/or an advanced seismic event bulletin produced by the International Data Centre (IDC) of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO PrepCom) could reduce uncertainties and improve confidence in analyses. Specifically, temporally-separated images can reduce uncertainty by identifying areas where change has occurred (e.g., building construction or demolition, road or facilities improvements). The primary goal of this project was to develop an automated geospatial processing script for imagery change detection to better reflect needs of the technical community (including the IDC) and to make the use of such a tool accessible in a variety of settings across platforms. Technical experts at Los Alamos National Laboratory successfully built GAIA: the Geospatial Automated Imagery Analysis tool, to fill this need. GAIA combines five tool components to produce orthorectified time separated imagery and imagery change detection maps. Our toolkit (1) reduces error by providing a standardized workflow for image analyses and (2) significantly reduces processing time from between 7 and 24+ hours to approximately 5 minutes. Technical experts at Sandia National Laboratories supported GAIA via beta-testing and by introducing a web-based system approach for increased applicability. To test the function, performance, broad application, and ease-of-use of GAIA, we applied it to four separate test cases. The results of this preliminary investigation show promise in reducing uncertainty in seismic event locations: if satellite imagery can show regions where operations that produce seismic activity likely occurred, then pursuing imagery to locate epicenters of seismic nuclear events could reduce the time needed to find the true epicenter location.

58 GEOSCIENCES↗

Imagery Applications for Advanced Event Analytics (WBS 24.3.1.3.3-IDC FY2020 Final Project Report)

Accurate event locations and replicability of location analyses are essential for assessing the nature of an event, its context, ambient site conditions, and proximity to relevant facilities and infrastructure. Additionally, accurate event locations provide valuable information that reduce uncertainties, improve confidence in event analyses, and inform in-field verification activities. However, event location/relocation and replicability are difficult due to a number of factors, including spatially-sparse network coverage in some areas of the globe and variability in seismic data processing. This team proposed that the incorporation of high-fidelity imagery as a data backbone to the analytical assessment of a suspected underground explosion and/or an advanced seismic event bulletin produced by the International Data Centre (IDC) of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO PrepCom) could reduce uncertainties and improve confidence in analyses. Specifically, temporally-separated images can reduce uncertainty by identifying areas where change has occurred (e.g., building construction or demolition, road or facilities improvements). The primary goal of this project was to develop an automated geospatial processing script for imagery change detection to better reflect needs of the technical community (including the IDC) and to make the use of such a tool accessible in a variety of settings across platforms. Technical experts at Los Alamos National Laboratory successfully built GAIA: the Geospatial Automated Imagery Analysis tool, to fill this need. GAIA combines five tool components to produce orthorectified time-separated imagery and imagery change detection maps. Our toolkit (1) reduces error by providing a standardized workflow for image analyses and (2) significantly reduces processing time from between 7 and 24+ hours to approximately 5 minutes. Technical experts at Sandia National Laboratories supported GAIA via beta-testing and by introducing a web-based system approach for increased applicability. To test the function, performance, broad application, and ease-of-use of GAIA, we applied it to four separate test cases. The results of this preliminary investigation show promise in reducing uncertainty in seismic event locations: if satellite imagery can show regions where operations that produce seismic activity likely occurred, then pursuing imagery to locate epicenters of seismic nuclear events could reduce the time needed to find the true epicenter location.

58 GEOSCIENCES↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Testing of an Ultrasonic Thermometer Developed at the Idaho National Laboratory

Ultrasonic thermometry has great potential to improve temperature measurements in irradiation experiments performed in nuclear test reactors. The flexibility of the measurement makes it applicable to a wide range of potential test conditions, in terms of temperature, radiation, and chemical environment. However, the range of several typical ultrasonic thermometer configurations are not well defined. The research described in this document attempts to define an operational envelop for multiple configurations and sensor materials.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Mechanical creep testing and characterization of Cr coated Zircaloy

Zirconium based cladding has been developed for use in light water reactor fuel applications due to the material’s desirable low neutron scattering cross section. To help improve corrosion resistance in accident conditions, such as a loss of coolant accident (LOCA), a chromium coating can be applied to the outer diameter of the Zircaloy tube. Cladding strength at reactor relevant temperatures is important for the structural performance. Stress relaxation creep testing was performed on Cr coated Zircaloy-4 to measure strain rate as a function of stress for 350 and 650°C. These were performed at both 5 ± 1 % and 7.5 ± 1 % strain. The lower temperature provides results near normal operating temperature, while the higher temperature provides results relevant to off-normal conditions where recrystallization will take place. Characterization was also performed to analyze the structure of the Cr coating and Zircaloy-4 as well as the interface between the two.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and statistical study on the effect of process parameters on the quality of continuous fiber composites made via additive manufacturing

Ongoing research in additive manufacturing towards structural and industrial application has led to the use of commingled roving as a manufacturing feedstock for printing high fiber volume fraction composites. The prospects of using this technology for high performance applications necessitates the need for a comprehensive experimental investigation into the effects of processing parameters on the quality of an additively manufactured composite printed from commingled roving feedstock. Here, in this work, transverse flexure and void fraction matrix pyrolysis testing are both performed to evaluate composite quality. The transverse flexure test is a testing approach that evaluates the quality of the interfacial fiber-matrix bond while the void fraction test estimates the void content in the printed composite. A full observational study consisting of 27 different test combinations is done to investigate the effects of three different process parameters namely, temperature, pressure, and print speed across three different levels. Composite samples were made from commingled roving of E-glass and amorphous PET using an in-house built continuous fiber composite digital manufacturing system. Least squares regression analysis is performed to study the main, interaction and quadratic effects of process parameters. A statistical regression model having an R2 adjusted value of 80.1% is generated from the transverse flexure study, which is used to explain main and interaction effects and also predict performance. Response surface plots are also generated and are used to optimize process parameters which can subsequently be of help in scaling up composite manufacturing. Results show that all three process parameters are highly statistically significant at the 0.01 level of significance. Pressure * Temperature and Pressure * Printspeed are significant interaction terms. Pressure plays a weightier role when print speed is increased or temperature is decreased as it closes more voids that would ordinarily have been introduced because of drop in polymer melt viscosity. Micrographic analysis is also performed.

36 MATERIALS SCIENCE↗

Prototype SSR2 Tuner Procurement and Testing at IJCLab for PIP-II Project

IJCLab is involved in the PIP-II project on the design and development of accelerator components for the SSR2 (Single Spoke Resonator type 2) section of the superconducting linac. Five prototype tuners have been built and are being tested at IJCLab. After a short description of the tuner, this paper reports on the procurement strategy and the performance observed at both room and low temperatures in vertical cryostat test with SSR2 prototype cavities. This paper will also share results on accelerated lifetime tests performed in a dedicated nitrogen-cooled cryostat.

43 PARTICLE ACCELERATORS↗

Numerical implementation of the MOOSE subchannel module (SCM) algorithm

The subchannel module of moose (SCM), previously referred to as Pronghorn-SC, is a subchannel code designed to resolve single-phase flow fields and calculate the relevant flow variables, in nuclear reactor fuel-pin assemblies. The assemblies it models are: water-cooled, with bare fuel-pins in a square ducted, quadrilateral lattice and liquid-metal/water-cooled, with bare/wire-wrapped fuel pins in a hexagonal ducted, triangular lattice. Previous publications have presented the development, validation and verification of SCM. This work presents an comparative overview of the different solvers implemented within SCM. This includes the solver algorithm description, and a performance comparison. The two test cases chosen to demonstrate the solver performance were taken from the PSBT enthalpy mixing benchmark and the ORNL-19 pin benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel Microshear Geometry for Exploring the Influence of Void Swelling on the Mechanical Properties Induced by MeV Heavy Ion Irradiation

Small disks are often the specimen of choice for exposure in nuclear reactor environments, and this geometry invariably limits the types of mechanical testing that can be performed on the specimen. Recently, shear punch testing has been utilized to evaluate changes arising from neutron irradiation in test reactor environments on these small disk specimens. As part of a broader effort to link accelerated testing using ion irradiation and conventional neutron irradiation techniques, a novel microshear specimen geometry was developed for use with heavy-ion irradiated specimens. The technique was demonstrated in pure Cu irradiated to 11 and 110 peak dpa with 10 MeV Cu ions. At 11 peak dpa, the Cu specimen had a high density of small voids in the irradiated region, while at 110 peak dpa, larger voids with an average void swelling of ~20% were observed. Micropillar and microshear specimens both exhibited hardening at 11 dpa, followed by softening at 110 dpa. The close alignment of the new microshear technique and more conventional micropillar testing, and the fact that both follow intuition, is a good first step towards applying microshear testing to a wider range of irradiated materials.

36 MATERIALS SCIENCE↗

Leveraging High-Fidelity Datasets for Machine Learning-based Anomaly Detection in Smart Grids

Data-driven intrusion detection systems are increasingly becoming essential for protecting critical cyber-physical infrastructure, such as the power grid, against the growing number of sophisticated cyber-attacks. The development of such tools is reliant on the availability of high-fidelity cyber-physical datasets that cover a diverse variety of potential cyber events. In this work, a high-fidelity smart grid platform is utilized to develop an extensive dataset, which is used to train and test a machine learning-based intrusion detection system. The evaluation of the developed IDS shows robust performance even when tested with statistically diverse test data not used in training.

Hyder, Burhan↗

Testing fast reactor fuels in a thermal reactor: Comparison of transmutation metallic fuel alloys behavior by scanning electron microscopy

To optimize nuclear waste repository performance, the destruction of minor actinide elements, particularly Np and Am, in a neutron fast spectrum reactor is possible by incorporating these elements into nuclear fuel. Evaluating the performance of minor actinide containing fuel is of paramount importance to enabling this technology. However, such a task is challenging without an available domestic fast spectrum test reactor. A comparison of fuel performance tested in an available domestic thermal reactor at the Idaho National Laboratory, the Advanced Test Reactor, and in a fast spectrum reactor in France (Phénix) is presented here in this study. This study evaluates the capability of using a cadmium shrouded test position to mimic the power profile along the fuel radius present in fast spectrum reactors so that thermally driven phenomenon (e.g., constituent redistribution) can be evaluated in a thermal reactor and determined to be prototypical of a fast reactor. Thus, optical microscopy and scanning electron microscopy has been performed on irradiated 35U-29Pu-4Am-2Np-30Zr fuel samples (where the number preceding the element is the weight percent concentration) from the two mentioned reactors that present similar irradiation temperatures and power conditions. The results indicate that fuel performance phenomena are reproducible in the two irradiation conditions. The redistribution of Zr occurred in the same manner for the two samples. Similar partitioning of U-Pu-Zr phases was observed, and the behavior of Am was similar in the analyzed specimens. Finally, the overall microstructure evolution seems not to be affected by minor actinides addition compared to expected behavior of conventional U-19Pu-10Zr ternary metal fuels for both specimens. Slight differences in fuel cladding chemical interaction were, however, observed. This difference is likely driven by difference in cladding composition rather than irradiation conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Wells RWM 6 and RWM 7

Hydrologic tests were conducted on the Lost Lake Aquifer Zone (LLAZ) at recovery wells RWM 6 and RWM 7 in accordance with the approved test plan (Dixon, 2023). The objective of the testing was to determine well performance parameters of RWM 6 and aquifer hydraulic properties near RWM 6 and RWM 7. Tests at RWM 6 consisted of a step-drawdown test to determine well performance parameters, a constant rate pump test to determine aquifer hydraulic properties, and an aquifer recovery test also used to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. Prior to testing at RWM 6, a constant rate pump test was conducted at RWM 7. Data from this testing was used to determine aquifer hydraulic properties near RWM 7.

42 ENGINEERING↗

Wrought FeCrAl alloy (C26M) cladding behavior and burst under simulated loss-of-coolant accident conditions

Cladding burst experiments for FeCrAl cladding were performed in the Severe Accident Test Station facility at Oak Ridge National Laboratory. These experiments were simulated using the BISON fuel performance code to better understand the cladding plastic behavior and failure under simulated loss-of-coolant accident conditions. 3D cladding surface boundary conditions were generated using composite axial and azimuthal profiles from experiment thermocouple data. To improve the simulation analysis capabilities in BISON for cladding burst behavior, new thermal creep, plasticity, and failure stress models specific to C26M, a wrought FeCrAl alloy, were developed and implemented. Initial cladding burst results indicated a general underprediction in the failure temperature of the six cladding burst simulations versus the observed failure temperatures. Close investigation of the experiment timing versus the underlying tensile test data revealed that, compared with the tensile specimens, the cladding tubes did not experience the same long holding time at high temperatures. New tensile tests were performed at high temperatures using a temperature ramp similar to the simulated loss-of-coolant accident experiments. These new tensile curves showed an approximately 80% increase in the ultimate tensile strength of the C26M alloy, indicating that a holding time of 10 min at 700 °C and 800 °C allows annealing to change the material microstructure. Using the updated tensile properties, the burst temperatures and stresses from the simulations showed remarkable agreement with the experimental results. This study was then extended by varying the initial pressure to highlight the burst temperature difference between standard Zircaloy-4 and C26M cladding under equivalent conditions. The results show that C26M has a burst temperature that is approximately 70–130 K greater than that of Zircaloy-4. In conclusion, these modeling predictions can be further improved by collecting high-temperature tensile data for C26M beyond the temperature ranges used in this work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗