Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Design and Modeling of Vacuum Pumping for Steady-State Pellet Fueling Systems

We report that future long-pulse magnetic confinement fusion reactors will require density and isotopic mixture control using steady-state repeating pellet injectors. For high-energy density burning plasmas, pellet velocities of 1 km/s and above will be required for sufficient plasma penetration to achieve high fueling efficiency. Currently, steady-state repeating injection systems utilize cryogenic extruder systems to produce an extrusion of solid deuterium or deuterium-tritium. In repeating light gas gun injectors, the solid extrusion is cut and simultaneously loaded into a barrel. Once loaded, a fast operating gas valve delivers a high pressure burst of gas to accelerate the pellet down the barrel and into the machine. This process takes ~10 ms to achieve. Adequate gas pumping of the extruder exhaust and injection line propellant gas collection chambers is necessary for optimal operation of the pellet fueling system. Excess solid from the extruder sublimates in an exhaust chamber. The gas pressure in the extruder exhaust chamber must remain low to maintain low heating loads on the cooling mechanism (cryorefrigerators or liquid helium flow) and to reduce thermal conduction to the extrusion. Pumping the injection line chambers is necessary to limit propellant gas flow into the machine. A numerical simulation code was created to predict temporal pumping performance for these repeating pellet injection systems. Lastly, this paper outlines the methods and assumptions used to create this model and compares results to the pellet injection system currently employed on DIII-D, the steady-state pellet injection system planned for the Wendelstein 7-X, and a brief analysis of the ITER conceptual pellet fueling system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Tokamak Discharge Shutdown with Shell Pellet Payload Impurity Dispersal

The first rapid tokamak discharge shutdown using dispersive core payload deposition with shell pellets has been achieved in the DIII-D tokamak. Shell pellets are being investigated as a possible new path toward achieving tokamak disruption mitigation with both low conducted wall heat loads and slow current quench. Conventional disruption mitigation injects radiating impurities into the outer edge of the tokamak plasma, which tends to result in poor impurity assimilation and creates a strong edge cooling and outward heat flow, thus requiring undesirable high-$Z$ impurities to achieve low conducted heat loads. The shell pellet technique aims to produce a hollow temperature profile by using a thin, low-ablation shell surrounding a dispersive payload, giving a greatly increased impurity ablation (and radiation) rate when the payload is released in the plasma core. This principle was demonstrated successfully using 3.6 mm outer diameter, 40 μ m thickness diamond shells holding boron powder. The pellets caused rapid (<10 ms) discharge shutdown with low conducted divertor heat fluence (~0.1 MJ/m 2 ). Confirmation of massive release of the boron powder payload into the plasma core was obtained spectroscopically. Some evidence for the formation of a hollow temperature profile during the shutdown was observed. Furthermore, these first results open a new avenue for disruption mitigation research, hopefully enabling development of highly effective methods of avoiding disruption wall damage in future reactor-scale tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Requirements for self-magnetically insulated transmission lines

Self-magnetically insulated transmission lines (MITLs) connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i) electron retrapping in coupling MITLs to loads, (ii) the applicability of collisionless versus collisional electron flow, (iii) power transport efficiency as a function of the geometry at the beginning of the MITL, (iv) gap closure and when gap closure can be neglected, and (v) the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.

43 PARTICLE ACCELERATORS↗

High Explosive Detonation–Confiner Interactions

The primary purpose of a detonation in a high explosive (HE) is to provide the energy to drive a surrounding confiner, typically for mining or munitions applications. The details of the interaction between an HE detonation and its confinement are essential to achieving the objectives of the explosive device. For the high pressures induced by detonation loading, both the solid HE and confiner materials will flow. The structure and speed of a propagating detonation, and ultimately the pressures generated in the reaction zone to drive the confiner, depend on the induced flow both within the confiner and along the HE–confiner material interface. The detonation–confiner interactions are heavily influenced by the material properties and, in some cases, the thickness of the confiner. This review discusses the use of oblique shock polar analysis as a means of characterizing the possible range of detonation–confiner interactions. Computations that reveal the fluid mechanics of HE detonation–confiner interactions for finite reaction-zone length detonations are discussed and compared with the polar analysis. Furthermore this includes cases of supersonic confiner flow; subsonic, shock-driven confiner flow; subsonic, but shockless confiner flow; and sonic flow at the intersection of the detonation shock and confiner material interface. We also summarize recent developments, including the effects of geometry and porous material confinement, on detonation–confiner interactions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Use of radial self-field geometry for intense pulsed ion beam generation above 6 MeV on Hermes III.

We investigate the generation and propagation of intense pulsed ion beams at the 6 MeV level and above using the Hermes III facility at Sandia National Laboratories. While high-power ion beams have previously been produced using Hermes III, we have conducted systematic studies of several ion diode geometries for the purpose of maximizing focused ion energy for a number of applications. A self-field axial-gap diode of the pinch reflex type and operated in positive polarity yielded beam power below predicted levels. This is ascribed both to power flow losses of unknown origin upstream of the diode load in Hermes positive polarity operation, and to anomalies in beam focusing in this configuration. A change to a radial self-field geometry and negative polarity operation resulted in greatly increased beam voltage (> 6 MeV) and estimated ion current. A comprehensive diagnostic set was developed to characterize beam performance, including both time-dependent and time-integrated measurements of local and total beam power. A substantial high-energy ion population was identified propagating in reverse direction, i.e. from the back side of the anode in the electron beam dump. While significant progress was made in increasing beam power, further improvements in assessing the beam focusing envelope will be required before ultimate ion generation efficiency with this geometry can be completely determined.

43 PARTICLE ACCELERATORS↗

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials

Chemical reactions involving ozone of outdoor origin and indoor materials are known to be significant sources of formaldehyde and other irritant gas-phase oxidation products in the indoor environment. HVAC filters are exposed to particularly high ozone concentrations--close to outdoor levels. In this study, we investigated chemical processes taking place on the surface of filters that included fiberglass, polyester, cotton/polyester blend and synthetic (e.g., polyolefin) filter media. Ozone reactions were studied on unused filter media, and on filters that were deployed for 3 months in two different locations: at the Lawrence Berkeley National Laboratory and at the Port of Oakland. Specimens from each filter were exposed to ozone under controlled conditions in a laboratory flow tube at a constant flow of dry or humidified air (50percent relative humidity). Ozone was generated with a UV source upstream of the flow tube, and monitored using a photometric detector. Ozone breakthrough curves were recorded for each sample exposed to ~;;150 ppbv O3 for periods of ~;;1000 min, from which we estimated their uptake rate. Most experiments were performed at 1.3 L/min (corresponding to a face velocity of 0.013 m/s), except for a few tests performed at a higher airflow rate, to obtain a face velocity of 0.093 m/s, slightly closer to HVAC operation conditions. Formaldehyde and acetaldehyde, two oxidation byproducts, were collected downstream of the filter and quantified. Emissions of these volatile aldehydes were consistently higher under humidified air than under dry conditions, at which levels were near the limit of detection. Our results confirm that there are significant reactions of ozone as air containing ozone flows through HVAC filters, particularly when the filters are loaded with particles and the air is humidified. The amount of ozone reacted was not clearly related to the types of filter media, e.g., fiberglass versus synthetic. Specific fiberglass filters that were coated with an impaction oil showed significantly higher formaldehyde emissions than most other samples. Those emissions were magnified in the presence of particles (i.e., in used filters), and were observed even in the absence of ozone, which suggests that hydrolysis of filter binder or tackifier additives may be the reason for those high emissions. Mass balance calculations indicate that the emission rates of formaldehyde and acetaldehyde from the filters are generally not large enough to substantially increase indoor formaldehyde or acetaldehyde concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

8-Plate Multi-Resonant Coupling Using a Class-E 2 Power Converter for Misalignments in Capacitive Wireless Power Transfer

Misalignment is a common issue in wireless power transfer systems. It shifts the resonant frequency away from the operating frequency that affects the power flow and efficiency from the charging station to the load. This work proposes a novel capacitive wireless power transfer (CPT) using an 8-plate multi-resonant capacitive coupling to minimize the effect of misalignments. A single-active switch class-E 2 power converter is utilized to achieve multi-resonance through the selection of different resonant inductors. Simulations show a widening of the resonant frequency band which offers better performance than a regular 4-plate capacitive coupling for misalignments. The hardware results of the 8-plate multi-resonant coupling show an efficiency of 88.5% for the 20.8 W test, which is 18.3% higher than that of the regular 4-plate coupling. Because of the wider resonant frequency band {455–485 kHz}, compared with the regular 4-plate coupling, the proposed design minimized the output voltage drop by 15% for a 10% misalignment. Even for large misalignments, the 8-plate performance improved by 40% compared with the 4-plate coupling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 1: Summary

Numerous candidate APU concepts are considered, each meeting the space shuttle APU problem statement. Evaluation of these concepts indicates that the optimum concept is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. A preliminary design of the selected APU concept is presented, placing primary emphasis on the cycle thermal management and the controls. Results for both steady state and transient APU performance are also included, based on digital computer programs developed during the study. The selected APU provides up to 400 hp out of the gearbox, has a fixed weight of about 277 lb, and requires about 2 lb/shp-hr of propellants.

Hamilton, M. L.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 5: Selected system cycle performance data

Detailed cycle steady-state performance data are presented for the final auxiliary power unit (APU) system configuration. The selection configuration is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. The data are given in the form of computer printouts and provide the following: (1) verification of the adequacy of the design to meet the problem statement for steady-state performance; (2) overall system performance data for the vehicle system analyst to determine propellant consumption and hydraulic fluid temperature as a function for varying mission profiles, propellant inlet conditions, etc.; and (3) detailed component performance and cycle state point data to show what is happening in the cycle as a function of the external forcing functions.

Hamilton, M. L.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 3: Details of system analysis, engineering, and design for selected system

Numerous candidate APU concepts, each meeting the space shuttle APU problem statement are considered. Evaluation of these concepts indicates that the optimum concept is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads.

Hamilton, M. L.↗

Investigation of arterial gas occlusions

The effect of noncondensable gases on high-performance arterial heat pipes was investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate, and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, were used to postulate stability criteria for arterial heat pipes under isothermal and non-isothermal condensate flow conditions. A rigorous second-order gas-loaded heat pipe model, incorporating axial conduction and one-dimensional vapor transport, was produced and used for thermal and gas studies. A Freon-22 (CHCIF2) heat pipe was used with helium and xenon to validate modeling. With helium, experimental data compared well with theory. Unusual gas-control effects with xenon were attributed to high solubility.

Saaski, E. W.↗

Comparisons of Theoretical and Experimental Pressure Distributions on an Arrow-Wing Configuration at Subsonic, Transonic, and Supersonic Speeds

A wind tunnel test of an arrow wing body configuration consisting of flat and twisted wings, as well as a variety of leading- and trailing-edge control surface deflection, has been conducted at Mach numbers from 0.40 to 2.50 to provide an experimental data base for comparison with theoretical methods. Theory-to-experiment comparisons of detailed pressure distributions have been made using current state-of-the-art attached- and separated-flow methods. The purpose of these comparisons was to delineate conditions under which these theories are valid for aeroelastic calculations and to explore the use of empirical methods to correct the theoretical methods where theory is deficient. It was determined that current state-of-the-art attached flow and empirical methods were inadequate to predict aeroelastic loads for this configuration.

Manro, M. E.↗

Performance tests with a 4.75 inch bore tapered-roller bearings at high speeds

The tapered-roller bearings were tested at speeds to 15,000 rpm which results in a cone-rib tangential velocity of 130 m/sec. (25,500 ft/min). Lubrication was applied either by jets or directly to the cone-rib, augmented with jets. Additional test parameters included thrust loads to 53,400 N (12,000 lbs), radial loads to 26,700 N (6,000 lbs), lubricant flow rates from 1.9 x 0.000 to 15.1 x 0.001 cubic meter/min. (0.5 to 4.0 gpm), and lubricant inlet temperatures of 350 K and 364 K (170 F and 195 F). Temperature distribution, separator speed, and drive-motor power demand were determined as functions of these test parameters.

Signer, H. R.↗

Nonlinear, unsteady aerodynamic loads on rectangular and delta wings

Nonlinear unsteady aerodynamic loads on rectangular and delta wings in an incompressible flow are calculated by using an unsteady vortex-lattice model. Examples include flows past fixed wings in unsteady uniform streams and flows past wings undergoing unsteady motions. The unsteadiness may be due to gusty winds or pitching oscillations. The present technique establishes a reliable approach which can be utilized in the analysis of problems associated with the dynamics and aeroelasticity of wings within a wide range of angles of attack.

Atta, E. H.↗