Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lab data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Technology Development in Support of Hyperspectral Infrared Atmospheric Sounding in a CubeSat

Hyperspectral infrared sounding in a CubeSat will provide a new dimension to the current suite of IR sounders by allowing measurements at multiple times of day and enabling formation flying of IR sounders for new data products such as Atmospheric Motion Vector (AMV) winds. This paper focuses on technology development during the CubeSat Infrared Atmospheric Sounder (CIRAS) project sponsored by the NASA Earth Science Technology Office (ESTO), and coincident studies by the NOAA Office of Projects, Planning, and Analysis (OPPA). The CIRAS approach incorporates key new instrument technologies developed at JPL’s Microdevices Lab (MDL) including a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The second key technology is an MWIR Grating Spectrometer (MGS) designed by Ball Aerospace with a JPL MDL slit and immersion grating to provide hyperspectral infrared imaging in a CubeSat volume. The third key technology is a blackbody calibration target fabricated with MDL’s black silicon to have very high emissivity in a flat plate construction. JPL has completed design and breadboard of the mechanical, electronic and thermal subsystems for CIRAS payload including a HOT-BIRD FPA, with filters in a dewar and a breadboard of the electronics and scan mirror assembly. Blue Canyon Technologies, developer of the CIRAS 6U CubeSat, completed the Final Design Review for the spacecraft.

Yee, Karl↗

Design of a Low-Cost, Submersible, Digital Holographic Microscope for in Situ Microbial Imaging

The methodologies for studying marine microbiology typically consist of utilizing instrumentation within a laboratory. This typically requires extracting a sample from its place of origin prior to examination, which may be days after collection. Oftentimes, the solution is to bring the lab to the ocean, which may be costly and provide further limitations for a sterile and stable laboratory environment. Here we present a low-cost, submersible, digital holographic microscope (DHM) designed to image marine microorganisms (such as bacteria and plankton) in their natural underwater environment. Our instrument eliminates the need to transport samples and allows for instantaneous data collection of microbes in-situ. The DHM achieves sub-micron spatial resolution and is paired with artificial intelligence for the detection and tracking of specimens to reduce the overall collected data. This instrument also aims to reduce the cost of manufacturing and field expenses relative to marine microbiological research. “Off the shelf” components were selected in the design process of this instrument which allows us to achieve precise results without sacrificing data quality. The DHM itself costs under one thousand dollars and features a low-cost high-resolution camera, the Arducam MT9J001. Included in the design were five main subsystems: optical, mechanical, electrical, power, and machine learning. Our on board computer and artificial intelligence consist of a Raspberry Pi 4 (8 Gb) and Google Coral USB Tensorflow accelerator. Instrument testing has successfully proven our abilities of data acquisition for at least two hours in depths of at least forty meters below sea level. Additionally, our artificial intelligence system is currently capable of tracking up to ten areas of interest in a fraction of a second with over ninety percent confidence via the neural net driven by the tensor cores on the Google Coral. Furthermore, we have demonstrated the versatility of our instrument by mounting it on an ocean-going ROV, the BlueRov2 by BlueRobotics. Our tests on the BlueRov2 exemplified the cost-effective nature of a submersible and reusable instrument that can be implemented in moderate environments and on most vessels.

Wallace, James Kent↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

A Survey of Open Source Software Repositories in the U.S. Department of Energy’s National Laboratories

There are 17 national laboratory systems in the United States operating under the auspices of the U.S. Department of Energy (DOE). These government labs employ tens of thousands of people engaging in research software engineering activities across a variety of missions. To support this work, many open source projects are maintained. Further, many of these projects have broad utility to the computing community at large and domain scientists in a variety of fields. However, the complexity and decentralized nature of the laboratory system has resulted in a situation where no one entity even knows about all the open source software projects in this ecosystem, let alone crude metrics of their health. In this article, we do the first external inventory of open source software repositories with a nexus to DOE labs. We posit that a project’s need for sustainability support can be determined by comparing measures of active use to measures of active maintenance.

97 MATHEMATICS AND COMPUTING↗

Greggd

greg(g)d - Global runtime for eBPF-enabled gathering (w/ gumption) daemon Recently the linux kernel has added support for low-level kernel monitoring and profiling through a in-kernel virtual machine. The tooling around these new features (the extended Berkley Packet Filter or eBPF for short) is not mature and is difficult to use. Benefits from eBPF are especially hard to realize while trying to do large scale deployments and integrate with existing metric analysis stacks. A tool was needed to enable loading and collecting data from eBPF programs on large scale HPC systems. Given the problems above it was obvious we needed some wrapper program to compile, load, and collect data from eBPF programs running in the kernel. This tool needed to be lightweight without a heavy set of dependencies, relatively stable between different kernel versions, and integrate nicely with existing widely used metric collection tools. We wrote a program that wraps the eBPF tooling and sends data to our metric gathering tool. eBPF programs are either compiled using the host compiler stack, or loaded in the kernel directly from an object file. These programs are then attached to the system calls that we want to profile. Whenever these system calls are run, the eBPF program collects information of interest and writes that to memory. Our wrapper program polls these memory locations, reads and formats the data, then sends the information to a local unix socket. Our other monitoring tools are configured to read from that socket and send it to the rest of our metric monitoring stack for analysis.

Voss, Joseph [Oak Ridge National Lab. (ORNL), Oak ↗

Kinetic Deep Learning v0.1

Here, we present a method that uses protein levels to predict times series of metabolite concentrations. Understanding this type of pathway dynamics is important in order to predict the behavior of the pathway and, more pragmatically, to be able to design biological systems (such as strains bioengineered to produce chemical products) reliably. Typically, for this purpose, kinetic models consisting of differential equations based on the Michaelis-Menten dynamics have been used in the past. However, these methods can rarely produce good fits to measured data time series. Possibly, this happens because the kinetic constants are unknown or are different from the ones measured in vivo, or perhaps because Michaelis-Menten dynamics is not a satisfactory description. In order to improve the predictive nature of these kinetic models we have eliminated the Michaelis-Menten description of pathway dynamics and we have substituted it by algorithms that automatically learn these dynamics from previously obtained metabolomics and proteomics data using machine learning approaches. Specifically, kinetic deep learning uses deep learning to map proteomics time series to metabolite concentration time series, instead of learning the first metabolite derivative and integrating in (as in the first version of kinetic learning). This approach is shown to provide good to excellent results with a data set specifically collected for this purpose.

Garcia Martin, Hector [Joint BioEnergy Institute (↗

A Curated Dataset of Regional Meteor Events with Simultaneous Optical and Infrasound Observations (2006–2011)

We present a curated, openly accessible dataset of 71 regional meteor events simultaneously recorded by optical and infrasound instrumentation between 2006 and 2011. These events were captured during an observational campaign using the all-sky cameras of the Southern Ontario Meteor Network and the co-located Elginfield Infrasound Array. Each entry provides optical trajectory measurements, infrasound waveforms, and atmospheric specification profiles. The integration of optical and acoustic data enables robust linkage between observed acoustic signals and specific points along meteor trajectories, offering new opportunities to examine shock wave generation, propagation, and energy deposition processes. This release fills a critical observational gap by providing the first validated, openly accessible archive of simultaneous optical–infrasound meteor observations that supports trajectory reconstruction, acoustic propagation modeling, and energy deposition analyses. By making these data openly available in a structured format, this work establishes a durable reference resource that advances reproducibility, fosters cross-disciplinary research, and underpins future developments in meteor physics, atmospheric acoustics, and planetary defense.

astrometry↗

Challenges in predicting protein-protein interactions of understudied viruses: Arenavirus-human interactions

Understanding protein-protein interactions (PPIs) between viruses and host organisms is crucial for uncovering infection mechanisms and identifying potential therapeutic targets. The ability to generalize PPI predictive models across understudied viruses presents a significant challenge. In this work, we use arenavirus-human PPIs to illustrate the difficulties associated with model generalization, which are compounded by a lack of both positive and negative data. We employ a Transfer Learning approach to investigate arenavirus-human PPIs by utilizing models trained on better-studied virus-human and human-human PPIs. Additionally, we curate and assess four types of negative sampling datasets to evaluate their impact on model performance. Despite the overall high accuracies (93–99 %) and AUPRC scores (0.8–0.9) appearing promising, further analysis indicates that these performance metrics can be misleading due to data leakage, data bias, and overfitting, especially concerning under-represented viral proteins. We reveal these gaps and assess the impact of data imbalance using standard k-fold cross-validation and Independent Blind Testing with a Balanced Dataset, resulting in a drop in accuracy below 50 %. We propose a viral protein-specific evaluation framework that categorizes viral proteins into majority and minority classes based on their representation in the dataset, enabling comparison of model performance across these groups using balanced accuracies. This framework offers a more robust evaluation of model generalizability, addressing biases inherent in standard evaluation techniques and paving the way for more reliable PPI prediction models for understudied viruses.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of digital fringe projection operational parameters on detecting powder bed defects in additive manufacturing

Additive manufacturing is a technology transforming traditional production timelines. Specifically, metal additive manufacturing (MAM) has been increasingly adopted by a variety of industries, not only to prototype, but also to fulfill full production scale applications with much lower lead times. Like any maturing manufacturing technology, developments in verifying and validating processes are necessary to support continuous growth. Due to the complex nature of MAM, part quality and repeatability remain integral challenges that inhibit further adoption of MAM for critical component production. In this study, we present data taken from a developing in-process monitoring system designed to measure and detect powder bed defects (PBDs) in powder bed fusion MAM systems using surface height maps created with structured light illumination. We showcase the feasibility of the monitoring technique for in-process implementation by detecting streak PBDs with varying severities (height, width) created in a lab environment. We present results of powder bed measurements for varying experimental parameters of the structured light system such as illumination angle, illumination pattern, and number of illuminations. We also present an expression used to determine experimental height noise based on input parameters for PBD detection based on the instrument transfer function of the structured light monitoring system for arbitrary pixel intensity noise contributions. In conclusion, with the results of PBD detection across multiple experimental measurement parameters, we provide a best practices approach to in-process implementation of the monitoring system in powder bed fusion manufacturing.

36 MATERIALS SCIENCE↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

A 15-Year Retrospective on Immersive Visualization Lessons from the Applied Visualization Laboratory

This article shares the experiences of operating an immersive visualization laboratory over a 15-year period. The paper discusses valuable insights into the lessons learned from various projects, including the challenges they faced, such as technical difficulties, user adoption, and opportunities, and practical solutions for overcoming them. One crucial element for successful immersive visualization projects is interdisciplinary collaboration. The paper presents the advantages of immersive visualization technology, such as improved data comprehension, enhanced communication, and increased engagement in complex scenarios. We present the dynamic realm of virtual and augmented truth (VR/AR) technology in the context of a immersive laboratory system. We spotlight rising trends inside the integration of VR/AR tools for visualization. We also present our experience in dealing with the hardware and software additives in an immersive VR/AR labs, dropping light on the demanding situations and successes encountered throughout everyday operations. Furthermore, it offers practical knowledge and guidance based on years of experience in the field, which can help you overcome challenges and achieve success in your project.

99 GENERAL AND MISCELLANEOUS↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

Universal Solvent Viscosity Reduction via Hydrogen Bonding Disruptors

Liquid Ion Solutions LLC (DBA RoCo Global) in partnership with Carnegie Mellon University and Carbon Capture Scientific LLC, has performed lab-scale development and evaluation of novel additives that lower the viscosity of water-lean amine solvents for post-combustion carbon dioxide capture. This project focuses on developing additives that minimize the formation of long-range electrostatic and hydrogen bonding (HB) networks, decreasing the solvent viscosity, improving diffusion, and improving the process economics. The project objectives included: 1) performing computer simulation to understand the molecular interactions of the additive molecules in water-lean CO 2 capture solvents, 2) design and synthesis of HB disruptors additives, 3) performance testing with additive molecules on model amine solvents, and 4) demonstration of the effectiveness of the optimized additives in the presence of synthetic flue gas. To meet the abovementioned objectives, the project team utilized a holistic approach that combines molecular simulation, experimental testing, and economic analysis studies. The project team developed ab initio molecular model and then perform computer simulation to develop relationship between hydrogen bonding, viscosity, and performed quantitative analysis of additive on the viscosity of the solvent. The team completed computational comparative study on a range of organic functional groups such as ethers, esters, cyclic carbonates, alkanes, and ammonium salts for their effect on viscosity gaining key insights into molecular interactions and the impact of various functional groups and molecular shapes on viscosity. Assisted with molecular simulation insights, the project team conducted additive synthesis and testing, including a proof-of-concept study, additive screening, optimization, and synthetic flue gas testing. The experimental proof-of-concept study proved that the hydrogen bonding acceptors result in significant decrease of viscosities. Detailed additive screening (exploring various functionalities and molecular structures) has been performed. Several promising additives showed excellent reduction in viscosity (30-41%) at 5% additive loading, and over 50% viscosity reduction at 10% additive loading for the model solvents. The team also performed complex screening studies on additive loadings and mixing effect among additives using the design of experiments. Based on multiple screening experiments, one additive-solvent candidate was down-selected for synthetic flue gas testing. A 100-hour continuous absorption/desorption study was conducted under simulated flue gas using a lab-scale continuous capture and separation system. No degradation (for both solvent and additive) was observed based on the GC results of the solvent samples collected from the continuous study. The team conducted preliminary engineering analyses and cost-benefit analyses to quantify the potential economic benefits of the additive approach for solvent viscosity reduction. Based on the experimental data, CO 2 capture cost savings from the capital and operating cost savings are estimated at $\$$4.7/tonne and $\$$0.3/tonne CO 2 captured, respectively. Considering the additive cost, the net benefit is estimated to be between $\$$4.32~$\$$4.86/tonne CO 2 captured.

20 FOSSIL-FUELED POWER PLANTS↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

Data reduction by computer processing

The automated analysis of remote sensing data, specifically digital processing of LANDSAT or other image data in numerical form was considered in a technical workshop which covered the teaching of digital image processing, including both theoretical and applied subjects and laboratory experience, and also reviewed NASA developed image processing software, and hardware/software systems employed at NASA-Ames Research Center in support of the Western Regional Applications Program (WRAP). A course titled Image Processing Lab, one of two courses required for a graduate minor in remote sensing at Arizona is examined as well as the rationale, content, and hardware/software support for this course.

Lumb, D. R.↗

Soft X Ray Telescope (SXT) focus error analysis

The analysis performed on the soft x-ray telescope (SXT) to determine the correct thickness of the spacer to position the CCD camera at the best focus of the telescope and to determine the maximum uncertainty in this focus position due to a number of metrology and experimental errors, and thermal, and humidity effects is presented. This type of analysis has been performed by the SXT prime contractor, Lockheed Palo Alto Research Lab (LPARL). The SXT project office at MSFC formed an independent team of experts to review the LPARL work, and verify the analysis performed by them. Based on the recommendation of this team, the project office will make a decision if an end to end focus test is required for the SXT prior to launch. The metrology and experimental data, and the spreadsheets provided by LPARL are used at the basis of the analysis presented. The data entries in these spreadsheets have been verified as far as feasible, and the format of the spreadsheets has been improved to make these easier to understand. The results obtained from this analysis are very close to the results obtained by LPARL. However, due to the lack of organized documentation the analysis uncovered a few areas of possibly erroneous metrology data, which may affect the results obtained by this analytical approach.

Ahmad, Anees↗

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗