Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy efficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

PANTHER: A Programmable Architecture for Neural Network Training Harnessing Energy-Efficient ReRAM

The wide adoption of deep neural networks has been accompanied by ever-increasing energy and performance demands due to the expensive nature of training them. Additionally, numerous special-purpose architectures have been proposed to accelerate training: both digital and hybrid digital-analog using resistive RAM (ReRAM) crossbars. ReRAM-based accelerators have demonstrated the effectiveness of ReRAM crossbars at performing matrix-vector multiplication operations that are prevalent in training. However, they still suffer from inefficiency due to the use of serial reads and writes for performing the weight gradient and update step. A few works have demonstrated the possibility of performing outer products in crossbars, which can be used to realize the weight gradient and update step without the use of serial reads and writes. However, these works have been limited to low precision operations which are not sufficient for typical training workloads. Moreover, they have been confined to a limited set of training algorithms for fully-connected layers only. To address these limitations, we propose a bit-slicing technique for enhancing the precision of ReRAM-based outer products, which is substantially different from bit-slicing for matrix-vector multiplication only. We incorporate this technique into a crossbar architecture with three variants catered to different training algorithms. To evaluate our design on different types of layers in neural networks (fully-connected, convolutional, etc.) and training algorithms, we develop PANTHER, an ISA-programmable training accelerator with compiler support. Our design can also be integrated into other accelerators in the literature to enhance their efficiency. Our evaluation shows that PANTHER achieves up to 8.02×, 54.21×, and 103× energy reductions as well as 7.16×, 4.02×, and 16× execution time reductions compared to digital accelerators, ReRAM-based accelerators, and GPUs, respectively.

42 ENGINEERING↗

Energy-Efficient Capacitive Deionization through Electrode Modification and Process Development

Electrochemical separation technologies, such as capacitive deionization (CDI), are promising for addressing global energy and water challenges. However, there is a need to improve the performance, better understand property-performance relationships, and evaluate the longevity of CDI electrodes. This study explores the chemical modification of electrodes and the adjustment of CDI operating parameters. Results indicate that nitric acid (HNO3) conditioning of activated carbon cloth (ACC) electrodes removes metal oxides, introduces oxygen and nitrogen functionalities, and increases the specific capacitance (16% at 1 mV/s). Moreover, these changes in electrode properties positively impact device-level CDI performance. Through HNO3-conditioning of the ACC and tuning of the operational parameters, this work demonstrates higher electrosorption capacity (4.0x), greater charge efficiency (90% vs 24%), and lower energy consumption (3.8x). Despite these enhancements, limitations of the HNO 3 -conditioned ACC include decreased desorption kinetics and a 32% loss in electrosorption capacity after 200 cycles. Overall, this work provides guidance on using oxidative pretreatment via HNO 3 to modify ACC electrodes for CDI and evaluates the trade-offs associated with varying operational parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficient Mobility Systems 2021 Annual Progress Report

DOE conducts research to understand how the changing mobility landscape will affect transportation energy consumption and identifies opportunities to create more efficient, affordable, reliable, accessible, equitable, and secure transportation options that enhance mobility for individuals and businesses. Within EERE, the EEMS Program is responsible for this research portfolio. This APR describes work that the EEMS Program conducted during FY 2021 in support of the EEMS Program goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Mobility Systems (2022 Annual Progress Report)

DOE conducts research to understand how the changing mobility landscape will affect transportation energy consumption and identifies opportunities to create more efficient, affordable, reliable, accessible, equitable, and secure transportation options that enhance mobility for individuals and businesses. Within EERE, the EEMS Program is responsible for this research portfolio. This APR describes work that the EEMS Program conducted during FY 2022 in support of the EEMS Program goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-efficient modification of reduction-melting for lead recovery from cathode ray tube funnel glass

Highlights: • We recovered Pb from cathode ray tube funnel glass using reduction melting process. • We modified the melting process to achieve Pb recovery with low energy consumption. • Pb in the funnel glass is efficiently recovered at 1000 °C by adding Na{sub 2}CO{sub 3}. • Pb remaining in the glass after reduction melting is extracted with 1 M HCl. • 98% of Pb in the funnel glass was recovered by reduction melting and HCl leaching. - Abstract: Lead can be recovered from funnel glass of waste cathode ray tubes via reduction melting. While low-temperature melting is necessary for reduced energy consumption, previously proposed methods required high melting temperatures (1400 °C) for the reduction melting. In this study, the reduction melting of the funnel glass was performed at 900–1000 °C using a lab-scale reactor with varying concentrations of Na{sub 2}CO{sub 3} at different melting temperatures and melting times. The optimum Na{sub 2}CO{sub 3} dosage and melting temperature for efficient lead recovery was 0.5 g per 1 g of the funnel glass and 1000 °C respectively. By the reduction melting with the mentioned conditions, 92% of the lead in the funnel glass was recovered in 60 min. However, further lead recovery was difficult because the rate of the lead recovery decreased as with the recovery of increasing quantity of the lead from the glass. Thus, the lead remaining in the glass after the reduction melting was extracted with 1 M HCl, and the lead recovery improved to 98%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilationstrategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costs are $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings betweenSalishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report to the Department of Energy Renewable Energy and Energy Efficiency

The Pala Band of Mission Indians was awarded a DOE-EERE Solar Energy Grant for FY 2016 and 2017. The project involved installing a 94.8 kW DC photovoltaic (PC) solar system on the Pala Fire Station to offset up to 95% of grid-derived energy and reduce overall CO 2 generation from the facility. Pala successfully installed rooftop and carport-mounted solar panels at the fire station, and to date has generated of 219,227 kWh of energy and offset 274,034 pounds of CO 2 . The project was successfully executed, and we recommend other tribes to undertake similar projects if they are located in areas with sufficient solar exposure. DOE should continue to make these funds available to tribes.

14 SOLAR ENERGY↗

Adaptive real-time methodology for optimizing energy-efficient computing

Dynamic voltage and frequency scaling (DVFS) is an effective way to reduce energy and power consumption in microprocessor units. Current implementations of DVFS suffer from inaccurate modeling of power requirements and usage, and from inaccurate characterization of the relationships between the applicable variables. A system and method is proposed that adjusts CPU frequency and voltage based on run-time calculations of the workload processing time, as well as a calculation of performance sensitivity with respect to CPU frequency. The system and method are processor independent, and can be applied to either an entire system as a unit, or individually to each process running on a system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive real-time methodology for optimizing energy-efficient computing

Dynamic voltage and frequency scaling (DVFS) is an effective way to reduce energy and power consumption in microprocessor units. Current implementations of DVFS suffer from inaccurate modeling of power requirements and usage, and from inaccurate characterization of the relationships between the applicable variables. A system and method is proposed that adjusts CPU frequency and voltage based on run-time calculations of the workload processing time, as well as a calculation of performance sensitivity with respect to CPU frequency. The system and method are processor independent, and can be applied to either an entire system as a unit, or individually to each process running on a system.

97 MATHEMATICS AND COMPUTING↗