Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

XRCF Testing Capabilities

The Space Optics Manufacturing Technology Center's X-ray Calibration Facility has been recently modified to test Next Generation Space Telescope (NGST) developmental mirrors at cryogenic temperatures (35 degrees Kelvin) while maintaining capability for performance testing of x-ray optics and detectors. The facility's current cryo-optical testing capability and potential modifications for future support of NGST will be presented.

Reily, Cary↗

Anaerobic Psychrophiles from Alaska, Antarctica, and Patagonia: Implications to Possible Life on Mars and Europa

Microorganisms preserved within the permafrost, glaciers, and polar ice sheets of planet Earth provide analogs for microbial life forms that may be encountered in ice or permafrost of Mars, Europa, Callisto, Ganymede, asteroids, comets or other frozen worlds in the Cosmos. The psychrophilic and psychrotolerant microbes of the terrestrial cryosphere help establish the thermal and temporal limitations of life on Earth and provide clues to where and how we should search for evidence of life elsewhere in the Universe. For this reason, the cold-loving microorganisms are directly relevant to Astrobiology. Cryo-preserved microorganisms can remain viable (in deep anabiosis) in permafrost and ice for millions of years. Permafrost, ice wedges, pingos, glaciers, and polar ice sheets may contain intact ancient DNA, lipids, enzymes, proteins, genes, and even frozen and yet viable ancient microbiota. Some microorganisms carry out metabolic processes in water films and brine, acidic, or alkaline channels in permafrost or ice at temperatures far below 0 T. Complex microbial communities live in snow, ice-bubbles, cryoconite holes on glaciers and ancient microbial ecosystems are cryopreserved within the permafrost, glaciers, and polar caps. In the Astrobiology group of the NASA Marshall Space Flight Center and the University of Alabama at Huntsville, we have employed advanced techniques for the isolation, culture, and phylogenetic analysis of many types of microbial extremophiles. We have also used the Environmental Scanning Electron Microscope to study the morphology, ultra-microstructure and chemical composition of microorganisms in ancient permafrost and ice. We discuss several interesting and novel anaerobic microorganisms that we have isolated and cultured from the Pleistocene ice of the Fox Tunnel of Alaska, guano of the Magellanic Penguin, deep sea sediments from the vicinity of the Rainbow Hydrothermal Vent and enrichment cultures from ice of the Patriot Hills of Antarctica. The microbial extremophiles recovered from permafrost, ice, cold pools and deep sea sediments may provide information relevant to the question of how and where we should search for evidence of extant or extinct microbial life elsewhere in the Cosmos.

Hoover, Richard B.↗

Sulfate- and Sulfur-Reducing Bacteria as Terrestrial Analogs for Microbial Life on Jupiter's Satellite Io

Observations from the Voyager and Galileo spacecraft have revealed Jupiter's moon Io to be the most volcanically active body of our Solar System. The Galileo Near Infrared Imaging Spectrometer (NIMS) detected extensive deposits of sulfur compounds, elemental sulfur and SO2 frost on the surface of Io. There are extreme temperature variations on Io's surface, ranging from -130 C to over 2000 C at the Pillan Patera volcanic vent. The active volcanoes, fumaroles, calderas, and lava lakes and vast sulfur deposits on this frozen moon indicate that analogs of sulfur- and sulfate-reducing bacteria might inhabit Io. Hence Io may have great significance to Astrobiology. Earth's life forms that depend on sulfur respiration are members of two domains: Bacteria and Archaea. Two basic links of the biogeochemical sulfur cycle of Earth have been studied: 1) the sulfur oxidizing process (occurring at aerobic conditions) and 2) the process of sulfur-reduction to hydrogen sulfide (anaerobic conditions). Sulfate-reducing bacteria (StRB) and sulfur-reducing bacteria (SrRB) are responsible for anaerobic reducing processes. At the present time the systematics of StRB include over 112 species distributed into 35 genera of Bacteria and Archaea. Moderately thermophilic and mesophilic SrRB belong to the Bacteria. The hyperthermophilic SrRB predominately belong to the domain Archaea and are included in the genera: Pyrodictium, Thermoproteus, Pyrobaculum, Thermophilum, Desulfurococcus, and Thermodiscus. The StRB and SrRB use a wide spectrum of substrates as electron donors for lithotrophic and heterotrophic type nutrition. The electron acceptors for the StRB include: sulfate, thiosulfate, sulfite, sulfur, arsenate, dithionite, tetrathionate, sulfur monoxide, iron, nitrite, selenite, fumarate, oxygen, carbon dioxide, and chlorine-containing phenol compounds. The Sulfate- and Sulfur-reducing bacteria are widely distributed in anaerobic ecosystems, including extreme environments like hot springs, deepsea hydrothermal vents, soda and high salinity lakes, and cryo-environments. Furthermore, the StRB and SrRB have Astrobiological significance as these anaerobic extremophiles may represent the dominant relic life forms that inhabited our planet during the extensive volcanic activity in the Earth's early evolutionary period.

Pikuta, Elena V.↗

Fatigue Crack Measurement in Composite Materials by Ultrasonic Methods

The nondestructive detection of intra-ply microcracking in unlined pressure vessels fabricated from composite materials is critical to ensuring mission success. Microcracking in composite structures due to combined fatigue and cryogenic thermal loading can be very troublesome to detect in-service and when it begins to link through the thickness can cause leakage and failure of the structure. These leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. The work presented herein develops a method and an instrument to locate and measure intraply fatigue cracking through the thickness of laminated composite material by means of correlation with ultrasonic resonance. Resonant ultrasound spectroscopy provides measurements which are, sensitive to both the microscopic and macroscopic properties of an object. Elastic moduli, acoustic attenuation, and geometry can all be probed. The approach is based on the premise of half-wavelength resonance. The method injects a broadband ultrasonic wave into the test structure using a swept frequency technique. This method provides dramatically increased energy input into the test article, as compared to conventional spike pulsed ultrasonics. This relative energy increase improves the ability to measure finer details in the materials character, such as micro-cracking and porosity. As the micro-crack density increases, more interactions occur with the higher frequency (small wavelength) components of the signal train causing the spectrum to shift toward lower frequencies. Preliminary experiments have verified a measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking. Methods involving self organizing neural networks and other clustering algorithms show that the resonance ultrasound signatures from composites vary with the degree of microcracking and can be separated and identified.

Walker, James L.↗

Current Status of High Performance Large Format Si:As IBC Detectors for SOFIA-like Applications

Airborne and space telescope astronomical observations in the 5-25 micrometer wavelength region, are critical for understanding the physical conditions, composition, chemistry, and excitation of many environments in the interstellar medium, external galaxies, solar system objects, extra-solar systems, and stars. The scientific impact is particularly unique in the 5-8 micrometer and 14-25 micrometer regions which are inaccessible or poorly observed from ground-based observatories. Large-format area mid-infrared (MIR) detectors sensitive over these wavelengths and operable under moderate backgrounds (greater than 10(circumflex)6 e-/s at R=2000, 10(micrometers)) are essential for efficient large-area survey imaging and for taking moderate resolution spectra over a large spectral range. Both SOFIA and passively cooled Explorer observatories could benefit from this technology. Current first-light SOFIA instruments use small-format MIR FPA's of sizes 128x128 and 256x256, With the collaboration of Raytheon Infrared Operations (RIO), NASA-ARC has been testing the first device of this kind, a combination of 1) the ALADDIN III readout multiplexer, cryo-processed for 6K operation, with 2) SIRTF IRAC-like Sides IBC detector material. designed for higher QE and low dark current. Here we report requirements. design, and initial fabrication and testing of the first 1024x1024 Si:As IBC mid-IR detector array for these conditions. This device has exhibited low dark current, moderate noise levels, and greater than 200,000 electron linear well size at 6K operation. We conclude with suggestions for future device development for optimal performance under moderate background, SOFIA- and low Earth orbit observing conditions.

Ennico, Kimberly↗

MSFC Test Results for Selected Mirrors: Brush-Wellman/Goodrich 0.5 meter Joined-Beryllium Mirror; IABG 0.5 meter C/SiC Mirror; Xinetics 0.5 meter SiC Mirror; and Kodak 0.23 meter SiO2 Mirror

The results of cryo tests performed at the XRCF on the above mirrors will be presented. Each mirror was tested from room-temperature to around 30 K. The first three were tested together on a 3-mirror stand in the large chamber using the PhaseCam interferometer, while the Kodak mirror was tested in the small chamber using the EPI interferometer.

Hadaway, James↗

MSFC/Ball Space-Act Test Results of SBMD

The results of two cryo tests of the SBMD that were funded by Ball Aerospace through a Space-Act Agreement with MSFC will be discussed. These tests followed the formal completion of the SBMD program. The PhaseCam interferometer, rather than the Wavescope Shack-Hartmann sensor, was used during these tests.

Hadaway, James↗

Ultrasonic Characterization of Fatigue Cracks in Composite Materials

Microcracking in composite structures due to combined fatigue and cryogenic loading can cause leakage and failure of the structure and can be difficult to detect in-service. In aerospace systems, these leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. The success of nondestructive evaluation to detect intra-ply microcracking in unlined pressure vessels fabricated from composite materials is critical to the use of composite structures in future space systems. The work presented herein characterizes measurements of intraply fatigue cracking through the thickness of laminated composite material by means of correlation with ultrasonic resonance. Resonant ultrasound spectroscopy provides measurements which are sensitive to both the microscopic and macroscopic properties of the test article. Elastic moduli, acoustic attenuation, and geometry can all be probed. The approach is based on the premise of half-wavelength resonance. The method injects a broadband ultrasonic wave into the test structure using a swept frequency technique. This method provides dramatically increased energy input into the test article, as compared to conventional pulsed ultrasonics. This relative energy increase improves the ability to measure finer details in the materials characterization, such as microcracking and porosity. As the microcrack density increases, more interactions occur with the higher frequency (small wavelength) components of the signal train causing the spectrum to shift toward lower frequencies. Several methods are under investigation to correlate the degree of microcracking from resonance ultrasound measurements on composite test articles including self organizing neural networks, chemometric techniques used in optical spectroscopy and other clustering algorithms.

Workman, Gary L.↗

A Mechanical Cryogenic Cooler for the Hubble Space Telescope

This paper presents a description of the Hubble Space Telescope (HST) Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) Cryo Cooler (NCC), the cutting edge technology involved, its evolution, performance, and future space applications. The NCC is the primary hardware component of the NICMOS Cooling System comprised of the NCC, an Electronics Support Module, a Capillary Pumped Loop/Radiator, and associated interface harnessing. The system will be installed during extravehicular activities on HST during Servicing Mission 3B scheduled for launch in February 2002. The NCC will be used to revive the NICMOS instrument, which experienced a reduced operational lifetime due to an internal thermal short in its dewar structure, and restore HST scientific infrared capability to operational status. The NCC is a state-of-the-art reverse Turbo-Brayton cycle cooler employing gas bearing micro turbo machinery, driven by advanced power conversion electronics, operating at speeds up to 7300 revolutions per second (rps) to remove heat from the NICMOS instrument.

Jedrich, Nicholas↗

Miniature Joule Thomson (JT) CryoCoolers for Propellant Management

A proof-of-concept project is proposed here that would attempt to demonstrate how miniature cryocoolers can be used to chill the vacuum jacket line of a propellant transfer line and thus to achieve transfer line pre-chill, zero boil off and possible propellant densification. The project would be performed both at UCF and KSC, with all of the cryogenic testing taking place in the KSC cryogenic test bed. A LN2 line available in that KSC test facility would serve to simulate a LOX transfer line. Under this project, miniature and highly efficient cold heads would be designed. Two identical cold heads will be fabricated and then integrated with a JT-type cryogenic system (consisting of a common compressor and a common external heat exchanger). The two cold heads will be integrated into the vacuum jacket of a LN2 line in the KSC cryo lab, where the testing will take place.

Kapat, Jay↗

Fatigue Crack and Porosity Measurement in Composite Materials by Thermographic and Ultrasonic Methods

Many nondestructive methods exist for the detection of localized material anomalies in an otherwise good composite structure. The problem arises when the material system as a whole has degraded during service or was improperly manufactured. Porosity and intra-ply microcracking are two such conditions that in unlined composite pressure vessels can be very troublesome to detect and when linked through the thickness can be critical to mission success. These leak paths may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. Research sought nondestructive methods for quantifying porosity and microcracking in composite tankage. Both thermographic and resonance ultrasound methods have been utilized with artificial neural network and statistical approaches to analyze the data. Resonant ultrasound spectroscopy provides measurements, which are sensitive to fine details in the materials character, such as micro-cracking and porosity. Here, the higher frequency (shorter wavelength) components of the signal train provide more significant interaction with the defects causing the spectral characteristics to shift toward lower amplitudes at the higher frequencies. As the density of the defects increases more interactions occur and more drastic amplitude changes are observed. From a thermal perspective, the higher the defect density the lower the through thickness thermal diffusivity will be. Utilizing a point heat source, and thermographically recording the heat profile with time, diffusivity calculations can be made which in turn can be related to the relative quality of the material. Preliminary experiments to verify the measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking and for porosity detection thermographically are presented. Methods involving supervised and unsupervised artificial neural networks as well as other clustering algorithms are developed for signal identification.

Walker, James L.↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

Callisto: A World in its Own Right

Callisto, once unknown and then disregarded after Voyager, has emerged in the post-Galileo era worthy of the same intense scientific scrutiny that is lavished upon her sisters, playing an essential role in our understanding of the evolution of icy moons, and in a larger sense, the grand tapestry of solar system history. Along with the discovery of Callisto’s conducting, probably fluid sub-surface layer, major Gulileo discoveries about Callisto include the complete absence of cryo-volcanic resurfacing, the relatively undifferentiated interior, and the presence of massive landform erosion from sublimation processes. Callisto’s landscape at decameter scales is unique among the Galilean satellites, and might be most akin to that of cometary nuclei. The process of sublimation degradation, previously underappreciated, is now recognized as a major surface modification process on Callisto. Its role in mass wasting and landslide initiation was elemental in creating the bizarre and astonishing scenery imaged by Galileo.

Jeffrey M. Moore↗

Development of a Novel Discontinuously Reinforced Aluminum for Space Applications

The present results indicated that: Al-Sc-Mg-X alloys were selected to provide higher strength from -423 to 450F. SiC and B4C were chosen as reinforcements. Fine spherical powder of Al-Sc-Mg-X was produced using helium gas atomization. Matrix alloy and DRA were processed using vacuum hot processing and extrusion. DRA showed very high strength 100ksi at cryo, RT and hydrogen. Ductility was low. Matrix alloy exhibited high strength and ductility. LCF of matrix was higher than DRA in high strain range.

Pandey, Awadh↗

Which Strategy for a Protein Crystallization Project?

The three-dimensional, atomic-resolution protein structures produced by X-ray crystallography over the past 50+ years have led to tremendous chemical understanding of fundamental biochemical processes. The pace of discovery in protein crystallography has increased greatly with advances in molecular biology, crystallization techniques, cryo-crystallography, area detectors, synchrotrons and computing. While the methods used to produce single, well-ordered crystals have also evolved over the years in response to increased understanding and advancing technology, crystallization strategies continue to be rooted in trial-and-error approaches. This review summarizes the current approaches in protein crystallization and surveys the first results to emerge from the structural genomics efforts.

Kundrot, Craig E.↗

Microcrack Quantification in Composite Materials by a Neural Network Analysis of Ultrasound Spectral Data

Intra-ply microcracking in unlined composite pressure vessels can be very troublesome to detect and when linked through the thickness can provide leak paths that may hinder mission success. The leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping into air pockets within the laminate. Ultrasonic techniques have been shown capable of detecting the presence of microcracking and in this work they are used to quantify the level of microcracking. Resonance ultrasound methods are utilized with artificial neural networks to build a microcrack prediction/measurement tool. Two networks are presented, one unsupervised to provide a qualitative measure of microcracking and one supervised which provides a quantitative assessment of the level of microcracking. The resonant ultrasound spectroscopic method is made sensitive to microcracking by tuning the input spectrum to the higher frequency (shorter wavelength) components allowing more significant interaction with the defects. This interaction causes the spectral characteristics to shift toward lower amplitudes at the higher frequencies. As the density of the defects increases more interactions occur and more drastic amplitude changes are observed. Preliminary experiments to quantify the level of microcracking induced in graphite/epoxy composite samples through a combination of tensile loading and cryogenic temperatures are presented. Both unsupervised (Kohonen) and supervised (radial basis function) artificial neural networks are presented to determine the measurable effect on the resonance spectrum of the ultrasonic data taken from the samples.

Walker, James L.↗

On Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after 5 heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

Galofaro, J.↗

Surface Figure Measurement at 20K: Silicon Carbide and Cesic Mirrors

This report presents the facility, methods, and results of testing cryogenically-cooled spherical mirrors, using standard phase-shifting interferometry, at the Goddard Space Flight Center (GSFC). Two mirrors were supplied to GSFC by the European Space Technology Center, so that GSFC could render a second, independent cryo-measurement of their surface figures at 20K. These mirrors, produced by Galileo Avionica and its partners, demonstrate the technology of silicon carbide and SiC-composite lightweighted mirrors, designed for high accuracy (10 nm rms surface figure error) at both room temperature and 20K. The two mirrors provided for testing at GSFC include one made of sintered silicon carbide (mirror blank by Bettini), and a second made of the C/Si/SiC composite known as Cesic (supplied by ECM). Both mirrors are f/2 spheres with 150 mm clear aperture, and with integral mounts. At GSFC, the mirrors will be measured first at at room temperature, making use of standard techniques, with a predicted uncertainty of 2 nm. Then each mirror will be tested in the cryostat, down to 20K: first freely supported and, second, mounted to a Cesic plate that models a Cesic optical bench. The uncertainty of the resultant surface figure error is predicted to be about 5 nm rms. Details of the uncertainty budget are discussed in a related poster. GSFC's techniques and results can be usefully compared to the measurements performed on the same two mirrors by and for Galileo Avionica, who used a somewhat different test configuration and alignment approach.

Blake, Peter↗