Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Predictive Models for Advanced Reactor Autonomous Control

Advanced reactor designs including microreactors and small modular reactors will contribute to the clean production of cheap energy, and autonomous control for advanced reactors is an appealing option for reducing cost. However, there is a lack of industry experience applying autonomous control for advanced nuclear reactors. To accelerate the development and industry acceptance of autonomous control software for nuclear reactors, we aim to demonstrate autonomous control of the Purdue University research reactor (PUR-1) using INL-developed model predictive control (MPC) methods. To prepare for this demonstration, data-driven predictive models based on process data collected from PUR-1 have been developed and integrated with MPC and used to control a physics-based model of PUR-1. A data-driven dynamics model and a gated recurrent unit (GRU) network were both trained on process data from PUR-1. The dynamics model was shown to effectively control the reactor model with MPC when provided reactivity as a control variable but failed to control the model through the control rod positions. The GRU network produced more accurate predictions than the dynamics model when evaluated on operational data, and future work will include the evaluation of the GRU network in the controller.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Coordinated Control of DFIG Based Wind Farms and SGs for Improving Transient Stability

This paper proposes a coordinated control of doubly fed induction generator (DFIG)-based wind farms' (WFs) post-fault active power and synchronous generators' (SGs) tripping with the aim of improving transient stability of both the first swing and multi swings. To achieve it, the impact mechanism of the WFs' post-fault active power and SGs' tripping on the stability margin of each swing is first presented by using extended equal area criterion (EEAC). Based on this, a principle of the coordinated control is put forward. The WFs' control period is designed as six stages, and the value of post-fault active power in each stage is suggested to improve the stability of the first five swings and maintain the post-fault steady state. To decrease the tripping amount of the SGs, the SGs are tripped only when WFs' control effect is not sufficient to avoid the instability. Then, by utilizing an “online pre-decision and real-time matching”scheme, an engineering application method for the control principle is proposed, where the control procedures and detailed parameters calculation are demonstrated. The numerical simulations show that the coordinated control has a better damping effect and a less control cost (less amount of tripped SGs) than the traditional DFIG control or traditional SG tripping.

17 WIND ENERGY↗

Computer System for Unattended Control of Negative Ion Source

The computer system for control of cw surface-plasma source of negative ions is described. The system provides an automatic handling of source parameters by the specified scenario. It includes the automatic source start and long-term operation with switching and control of the power supplies blocks, setting and reading of source parameters like hydrogen feed, cesium seed, electrodes' temperature, checking of the protection and blockings elements like vacuum degradation, absence of cooling water, etc. The semi-automatic mode of control is also available, where the order of steps and magnitude of parameters, included to scenario, is corrected in situ by the operator. Control system includes the main controller and a set of peripheral local controllers. Commands execution is carried out by the main controller. Each peripheral controller is driven by the stand-alone program, stored in its ROM. Control system is handled from PC via Ethernet. The PC and controllers are connected by fiber optic lines, which provide the high voltage insulation and the stable system operation in spite the breakdowns and electromagnetic noise of cross-field discharge. The PC program for data setting and information display is developed under the LabView.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural Networks for Modeling and Control of Particle Accelerators

Particle accelerators are host to myriad nonlinear and complex physical phenomena. They often involve a multitude of interacting systems, are subject to tight performance demands, and should be able to run for extended periods of time with minimal interruptions. Often times, traditional control techniques cannot fully meet these requirements. One promising avenue is to introduce machine learning and sophisticated control techniques inspired by artificial intelligence, particularly in light of recent theoretical and practical advances in these fields. Within machine learning and artificial intelligence, neural networks are particularly well-suited to modeling, control, and diagnostic analysis of complex, nonlinear, and time-varying systems, as well as systems with large parameter spaces. Consequently, the use of neural network-based modeling and control techniques could be of significant benefit to particle accelerators. For the same reasons, particle accelerators are also ideal test-beds for these techniques. Many early attempts to apply neural networks to particle accelerators yielded mixed results due to the relative immaturity of the technology for such tasks. The purpose of this paper is to re-introduce neural networks to the particle accelerator community and report on some work in neural network control that is being conducted as part of a dedicated collaboration between Fermilab and Colorado State University (CSU). We describe some of the challenges of particle accelerator control, highlight recent advances in neural network techniques, discuss some promising avenues for incorporating neural networks into particle accelerator control systems, and describe a neural network-based control system that is being developed for resonance control of an RF electron gun at the Fermilab Accelerator Science and Technology (FAST) facility, including initial experimental results from a benchmark controller.

43 PARTICLE ACCELERATORS↗

Application of step-response lambda tuning to proportional-integral controllers in water resource recovery facilities

Proportional-integral-derivative (PID) controllers in water resource recovery facilities (WRRFs) feedback control loops are commonplace. While simple to implement, such control loops are rarely tuned optimally or systematically. Heuristic tuning approaches are commonly applied with varying degrees of success using trial-and-error, ad hoc tuning rules, or duplication of tuning values from a similar system. However, there are effective methods, such as lambda tuning, produce acceptable tuning with limited effort. These are based on the step-response method, where a manual process perturbation is used to define the relationship between the manipulated and controlled variables. Based on such an experiment, a simple process model is constructed and used to determine the controller tuning values. In this work, we used the step-response method and lambda tuning for two control systems in full-scale WRRFs. This led to responsive and stable behavior of the controlled system as defined by the absolute average error of the controlled variable to setpoint and standard deviation of the manipulated variable. Tuning of feedback control loops can be completed successfully through a systematic approach, and this work suggests that tuning tools, like lambda, should be part of all wastewater treatment control engineers' toolbox.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies

Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bridging the gap: adapting advanced display technologies for use in hybrid control rooms

The Institute for Energy Technology (IFE), runs the OECD Halden Reactor Project (HRP), featuring a state-of-the-art research simulator facility in Halden, Norway, called HAMMLAB. HAMMLAB serves two main purposes: the study of human behaviour in interaction with complex process systems; and the development, test and evaluation of prototype control centres and their individual systems. By studying operator performance in HAMMLAB and integrating the knowledge gained into new designs, the HRP contributes to improving operational safety, reliability, efficiency and productivity. The U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program has contracted IFE to assist DOE national laboratory staff at Idaho National Laboratory (INL) in adapting HAMMLAB design concepts for the purpose of control room modernization at nuclear power plants in the U.S. In support of this effort, the DOE has built a simulator research facility at INL called the Human Systems Simulation Laboratory (HSSL). The HSSL is centered on control room modernization, in which industry provided plant instrumentation and controls are modified for upgrade opportunities. The HSSL houses the LWRS simulator, which is a reconfigurable full-scale and full-scope control room simulator. Consisting of 45 large touchscreens on 15 panels, the LWRS simulator is currently using this glass top technology to digitally represent and replicate the functionality of the analog I&C systems in existing control rooms. The LWRS simulator is reconfigurable in that different plant training simulator models obtained from the utilities can be run on the panels, and the panels can be physically moved and arranged to mimic the layout of those control rooms. The glass top technology and reconfigurability capabilities allow the LWRS simulator to be the research platform that is necessary to design, prototype, and validate human-system interface (HSI) technologies that can replace existing analog I&C. IFE has recently assisted INL in establishing the technical infrastructure for implementation of HSI prototypes from HAMMLAB into the HSSL to demonstrate relevant control room replacement systems in support of the LWRS program. In March, 2014, IFE delivered the first HSI prototype utilizing this infrastructure — a large screen overview display for INL's simulator. The co-operation now continues by developing Procedure Support Displays targeted for operators in hybrid control room settings. These prototypes are being validated with U.S. reactor operators in the HSSL and optimized to enhance their performance. This research serves as a crucial stepping stone toward incorporation of advanced display technologies into conventional main control rooms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Refurbishment program of HANARO control computer system

HANARO, an open-tank-in-pool type research reactor with 30 MW thermal power, achieved its first criticality in 1995. The programmable controller system MLC (Multi Loop Controller) manufactured by MOORE has been used to control and regulate HANARO since 1995. We made a plan to replace the control computer because the system supplier no longer provided technical support and thus no spare parts were available. Aged and obsolete equipment and the shortage of spare parts supply could have caused great problems. The first consideration for a replacement of the control computer dates back to 2007. The supplier did not produce the components of MLC so that this system would no longer be guaranteed. We established the upgrade and refurbishment program in 2009 so as to keep HANARO up to date in terms of safety. We designed the new control computer system that would replace MLC. The new computer system is HCCS (HANARO Control Computer System). The refurbishing activity is in progress and will finish in 2013. The goal of the refurbishment program is a functional replacement of the reactor control system in consideration of suitable interfaces, compliance with no special outage for installation and commissioning, and no change of the well-proved operation philosophy. HCCS is a DCS (Discrete Control System) using PLC manufactured by RTP. To enhance the reliability, we adapt a triple processor system, double I/O system and hot swapping function. This paper describes the refurbishment program of the HANARO control system including the design requirements of HCCS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Evidence for scale‐dependent topographic controls on wildfire spread

Abstract Wildfire ecosystems are thought to be self‐regulated through pattern–process interactions between ignition frequency and location, and patterns of burned and recovering vegetation. Yet, recent increases in the frequency of large wildfires call into question the application of self‐organization theory to landscape resilience. Topography represents a stable bottom‐up template upon which fire interacts as both a physical and an ecological process. However, it is unclear how topographic control changes geographically and across spatial scales. We analyzed fire perimeter and topography data from 16 Bailey ecoregions across the State of California to identify spatial correspondence between ecoregional fire event and topographic patch size distributions. We found both sets of distributions followed a power‐law form and were statistically similar across several orders of magnitude, for most ecoregions. As a direct test of topographic controls on fire event perimeters, we used a paired t ‐test across ~11,000 fires to identify differences in topographic attributes at fire boundaries versus fire interiors. Statistical significance was determined using 500 iterations of a neutral landscape model. Level of topographic control varied significantly by ecoregion and across topographic features. For example, north–south aspect breaks, valley bottoms, and roads showed a consistently high degree of spatial control on wildfire perimeters. Topographic controls were most pronounced in mountainous ecoregions and were least influential in arid regions. Ridgetops provided a low‐level control across all ecoregions. Spatial control was strongest for small (10 0 –10 2 ha) to medium (10 3 –10 4 ha) fire sizes, suggesting that controls were scale‐dependent rather than scale‐invariant. Roads were the dominant control across all ecoregions; however, removing roads from the analyses had no significant effect on the overall role of topography on wildfire extinguishment in this analysis. This result suggested that certain topographic settings show strong spatial control on fire growth, despite the presence of roads. Our results support the observation that both bottom‐up and top‐down factors constrain fire sizes and that there are likely scaling regions within fire size distributions wherein the dominance of these spatial controls varies. Human influences on fire spread may either diminish or enhance the role of some bottom‐up and top‐down factors, adding further complexity.

Povak, Nicholas A.↗

Overshadow PLC to Detect Remote Control-Logic Injection Attacks

Programmable logic controllers (PLCs) in industrial control systems (ICS) are vulnerable to remote control logic injection attacks. Attackers target the control logic of a PLC to manipulate the behavior of a physical process such as nuclear plants, power grids, and gas pipelines. Control logic attacks have been studied extensively in the literature, including hiding the transfer of a control logic over the network from both packet header-based signatures, and deep packet inspection. For instance, these attacks transfer a control logic code as data, into small fragments (one-byte per packet), that are further padded with noise data. To detect control logic in ICS network traffic, this paper presents Shade, a novel shadow memory technique that observes the network traffic to maintain a local copy of the current state of a PLC memory. To analyze the memory contents, Shade employs a classification algorithm with 42 unique features categorized into five types at different semantic levels of a control logic code, such as number of rungs, number of consecutive decompiled instructions, and n-grams. We then evaluate Shade against control logic injection attacks on two PLCs, Modicon M221 and MicroLogix 1400 from two ICS vendors, Schneider electric and Allen-Bradley, respectively. The evaluation results show that Shade can detect an attack instance (i.e., identifying at least one attack packet during the transfer of a malicious control logic) accurately without any false alarms.

Yoo, Hyunguk↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Assessing the structure of classical molecular optimal control landscapes

Here we consider laser-driven optimal control landscape of a molecule from a classical mechanical perspective. The goal of optimal control in the present work is to steer the molecule from an initial state to a target state, denoted by two distinct points in phase space. Thus, a particular control objective is given as the difference between the final achieved phase space point and the target. The corresponding control landscape is defined as the latter control objective as a functional of the control field. While previous examination of the landscape critical points (i.e., a suboptimal point on the landscape where there is a zero gradient) has shown that the landscape topology is generally trap-free, the structure of the landscape away from these critical points is not well understood. We explore the landscape structure by examining an underlying metric defined as the ratio R of the gradient-based optimization path length of the control field evolution to the Euclidean distance between a given initial control field and the resultant optimal control field, where the latter field corresponds to a point at the top of the landscape. We analyze the path length-to-distance ratio R analytically for a linear forced harmonic oscillator and numerically for a nonlinear forced Morse oscillator. For the linear forced harmonic oscillator, we find that R ≤ $\sqrt{2}$ and reaches its minimum value of 1 (i.e., corresponding to “a straight shot” through control space) in the large target time limit, as well as at special finite target times. The ratio R is similarly small for Morse oscillator simulations when following a steepest-ascent path to the top of the landscape, implying that the landscape is quite smooth and devoid of gnarled features. This conclusion is exemplified for a path discovered with R≃ 1.0 where simply following the initial gradient direction takes the climb very close to the top of the landscape. These findings are consistent with a variety of previous like simulations examining R in quantum control scenarios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decentralized control of units in smart grids for the support of renewable energy supply

Due to the significant environmental impact of power production from fossil fuels and nuclear fission, future energy systems will increasingly rely on distributed and renewable energy sources (RES). The electrical feed-in from photovoltaic (PV) systems and wind energy converters (WEC) varies greatly both over short and long time periods (from minutes to seasons), and (not only) by this effect the supply of electrical power from RES and the demand for electrical power are not per se matching. In addition, with a growing share of generation capacity especially in distribution grids, the top-down paradigm of electricity distribution is gradually replaced by a bottom-up power supply. This altogether leads to new problems regarding the safe and reliable operation of power grids. In order to address these challenges, the notion of Smart Grids has been introduced. The inherent flexibilities, i.e. the set of feasible power schedules, of distributed power units have to be controlled in order to support demand–supply matching as well as stable grid operation. Controllable power units are e.g. combined heat and power plants, power storage systems such as batteries, and flexible power consumers such as heat pumps. By controlling the flexibilities of these units we are particularly able to optimize the local utilization of RES feed-in in a given power grid by integrating both supply and demand management measures with special respect to the electrical infrastructure. In this context, decentralized systems, autonomous agents and the concept of self-organizing systems will become key elements of the ICT based control of power units. In this contribution, we first show how a decentralized load management system for battery charging/discharging of electrical vehicles (EVs) can increase the locally used share of supply from PV systems in a low voltage grid. For a reliable demand side management of large sets of appliances, dynamic clustering of these appliances into uniformly controlled appliance sets is necessary. We introduce a method for self-organized clustering for this purpose and show how control of such clusters can affect load peaks in distribution grids. Subsequently, we give a short overview on how we are going to expand the idea of self-organized clusters of units into creating a virtual control center for dynamic virtual power plants (DVPP) offering products at a power market. For an efficient organization of DVPPs, the flexibilities of units have to be represented in a compact and easy to use manner. We give an introduction how the problem of representing a set of possibly 10{sup 100} feasible schedules can be solved by a machine-learning approach. In summary, this article provides an overall impression how we use agent based control techniques and methods of self-organization to support the further integration of distributed and renewable energy sources into power grids and energy markets. - Highlights: • Distributed load management for electrical vehicles supports local supply from PV. • Appliances can self-organize into so called virtual appliances for load control. • Dynamic VPPs can be controlled by extensively decentralized control centers. • Flexibilities of units can efficiently be represented by support-vector descriptions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗