Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

The Method of Characteristics for 2-D Multigroup and Pointwise Transport Calculations in SCALE/CENTRM

SCALE 6 computes problem-dependent multigroup (MG) cross sections through a combination of the conventional Bondarenko shielding-factor method and a deterministic pointwise (PW) transport calculation of the fine-structure spectra in the resolved resonance and thermal energy ranges. The PW calculation is performed by the CENTRM code using a 1-D cylindrical Wigner-Seitz model with the white boundary condition instead of the real rectangular cell shape to represent a lattice unit cell. The pointwise fluxes computed by CENTRM are not exact because a 1-D model is used for the transport calculation, which introduces discrepancies in the MG self-shielded cross sections, resulting in some deviation in the eigenvalue. In order to solve this problem, the method of characteristics (MOC) has been applied to enable the CENTRM PW transport calculation for a 2-D square pin cell. The computation results show that the new BONAMI/CENTRM-MOC procedure produces very precise self-shielded cross sections compared to MCNP reaction rates.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guidance Detailing Methods to Calculate Criticality Accident Alarm System Detector Response and Coverage

This paper is an extended summary of a guidance document that was produced by Oak Ridge National Laboratory on the subject of computational analyses of Criticality Accident Alarm Systems (CAAS). This full guidance document reviews ANSI/ANS-8.3-1997 and provides examples on how to calculate the fission rate that produces the minimum accident of concern, how to calculate the response of a CAAS detector, and how to evaluate the coverage of a CAAS detector. Discussing a strategy on how to perform CAAS placement analysis concludes the full guidance document. All of the examples in the full guidance document are performed with SCALE 6.1 and MCNP5, and the full input files for both are provided. This extended summary of the full guidance document only reviews ANSI/ANS-8.3-1997, calculates the fission rate that produces the minimum accident of concern for a simple example, and provides an example for one of the approaches suggested in the CAAS placement analysis strategy that uses a forward Monte Carlo transport calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Of Hybrid Methods For Global Variance Reduction In Shielding Calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the relative uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed that create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally.

FW-CADIS↗

Validation of Criticality Safety Calculations with SCALE 6.2

SCALE 6.2 provides numerous updates in nuclear data, nuclear data processing, and computational tools utilized in the criticality safety calculational sequences relative to SCALE 6.1. A new 252-group ENDF/B-VII.0 multigroup neutron library, improved ENDF/B-VII.0 continuous energy data, as well as the previously deployed 238-group ENDF/B-VII.0 neutron library are included in SCALE 6.2 for criticality safety analysis. The performance of all three libraries for keff calculations is examined with a broad sampling of critical experiment models covering a range of fuels and moderators. Critical experiments from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE) that are available in the SCALE Verified, Archived Library of Inputs and Data (VALID) are used in this validation effort. Over 300 cases are used in the validation of KENO V.a, and a more limited set of approximately 50 configurations are used for KENO-VI validation. Additionally, some KENO V.a cases are converted to KENO-VI models so that an equivalent set of experiments can be used to validate both codes. For continuous-energy calculations, SCALE 6.2 provides improved performance relative to SCALE 6.1 in most areas with notable improvements in fuel pin lattice cases, particularly those with mixed oxide fuel. Multigroup calculations with the 252-group library also demonstrate improved performance for fuel lattices, uranium (high and intermediate enrichment) and plutonium metal experiments, and plutonium solution systems. Overall, SCALE 6.2 provides equivalent or smaller biases than SCALE 6.1, and the two versions of KENO provide similar results on the same suite of problems.

97 MATHEMATICS AND COMPUTING↗

CONTINUOUS-ENERGY MONTE CARLO METHODS FOR CALCULATING GENERALIZED RESPONSE SENSITIVITIES USING TSUNAMI-3D

This work introduces a new approach for calculating sensitivity coefficients for generalized neutronic responses to nuclear data uncertainties using continuous-energy Monte Carlo methods. The approach presented in this paper, known as the GEAR-MC method, allows for the calculation of generalized sensitivity coefficients for multiple responses in a single Monte Carlo calculation with no nuclear data perturbations or knowledge of nuclear covariance data. The theory behind the GEAR-MC method is presented here, and proof of principle is demonstrated by using the GEAR-MC method to calculate sensitivity coefficients for responses in several 3D, continuous-energy Monte Carlo applications.

CLUTCH↗

ITER Port Interspace Pressure Calculations

The ITER Vacuum Vessel (VV) is equipped with 54 access ports. Each of these ports has an opening in the bioshield that communicates with a dedicated port cell. During Tokamak operation, the bioshield opening must be closed with a concrete plug to shield the radiation coming from the plasma. This port plug separates the port cell into a Port Interspace (between VV closure lid and Port Plug) on the inner side and the Port Cell on the outer side. This paper presents calculations of pressures and temperatures in the ITER (Ref. 1) Port Interspace after a double-ended guillotine break (DEGB) of a pipe of the Tokamak Cooling Water System (TCWS) with high temperature water. It is assumed that this DEGB occurs during the worst possible conditions, which are during water baking operation, with water at a temperature of 523 K (250 C) and at a pressure of 4.4 MPa. These conditions are more severe than during normal Tokamak operation, with the water at 398 K (125 C) and 2 MPa. Two computer codes are employed in these calculations: RELAP5-3D Version 4.2.1 (Ref. 2) to calculate the blowdown releases from the pipe break, and MELCOR, Version 1.8.6 (Ref. 3) to calculate the pressures and temperatures in the Port Interspace. A sensitivity study has been performed to optimize some flow areas.

Interspace ITER Vacuum vessel↗

Research in Support of TREAT Kinetics Calculations Using Rattlesnake/BISON Coupling Within MAMMOTH

This paper summarizes key aspects of research in evaluation of modeling needs for TREAT transient simulation. Using measured data from transient experiments performed circa 1959 in a small, test core used for startup testing, MAMMOTH multi-physics simulations are per-formed to simulate the core transient behavior. MAMMOTH uses internal libraries from Rattlesnake for time-dependent transport calculations, BISON for fuel performance calcula-tions and the MOOSE multi-physics framework to perform strongly coupled calculations to properly characterize the three-dimensional temperature-driven kinetics performance of the core during rapid power excursions. Early calculations were able to match the general shape of measured transient data but under-predicted peak power. Closer examination of the phys-ics of the core and uncertainty associated with rod positioning led to calculations in which the best estimate of the actual measured reactor period was modeled. This correction resulted in outstanding agreement between measurements and coupled multi-physics simulation results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NEW MATRIX COEFFICIENTS FOR THE LOBE POWER CALCULATION AND INDICATION SYSTEM IN THE ADVANCED TEST REACTOR

Theoretical coefficients are tuned for use in the Advanced Test Reactor (ATR) Lobe Power Calculation and Indication System (LPCIS). The LPCIS indicates localized fission powers in the ATR, used primarily by operators to provide irradiation of various experiments at requested power levels. The LPCIS solves an overdetermined matrix, such that the best-fit solution can be obtained from at least five of up to eleven independent indications selected for input. Hourly data logs are reviewed for three and one-half years (from November 2013 through June 2017) of ATR operation to compare localized powers indicated by LPCIS with powers indicated by an independent indication, the Water Power Calculator (WPC). WPC indications are used for the calibration of LPCIS because of assumed high reliability and theoretical simplicity. WPC is also used for automatic core protective functions, which LPCIS is not. As the WPC provides power only for four quadrants and the LPCIS indicates power in five lobes, a calculated metric is required to compare the two indications. The metric chosen for the current work has been in use for decades at ATR as a metric of LPCIS health. The proposed new coefficients better fit theory of physical phenomena involved and also provide a 40% improvement in the calculated fit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE INFLUENCE OF CHANGES IN NUCLEAR COVARIANCE DATA ON THE CALCULATION OF Ck FOR HIGHLY ENRICHED URANIUM SOLUTION SYSTEMS

Since their initial development nearly 20 years ago, sensitivity/uncertainty (S/U) techniques have been increasingly applied to criticality safety validation. These techniques can generally be applied quickly and for a range of purposes after the initial investment of calculating sensitivities for a safety analysis model and a range of potential benchmark experiments. This paper discusses these applications and how they have been affected by changes in covariance data libraries.Critical experiment selection is the most prominent area in which S/U methods impact validation efforts. These methods allow for rigorous calculation of similarity between safety analysis models and potential benchmarks. The most widely used of these methods is the integral parameter ck, although other integral parameters such as E and some non-integral parameters have also been explored. The ck parameter calculates the fraction of nuclear data–induced uncertainty shared between an application and an experiment; this metric is predicated on the assessment that nuclear data errors are the most likely source of computational bias. Therefore, values of ck are inherently dependent on the nuclear covariance library used to calculate them and inevitably change when these data change.Past studies have shown how much the ck values can vary, especially in difficult validation cases like burnup credit. These significant changes are the result of differences in the relative uncertainties of nuclides with large sensitivities, and they imply differences in benchmark applicability to the safety analysis model. This paper demonstrates that more common criticality safety models involving single fissile species have significantly less variability of ck between covariance libraries, thus enhancing confidence in the application of S/U methods for experiment selection in these scenarios. This paper presents case studies examining the impact of these changes on some hypothetical safety analysis systems.

Clarity, Justin↗

Improvement of SCALE-XSPROC Multigroup Cross Section Processing Based on the CENTRM Pointwise Slowing Down Calculation

The SCALE-XSProc multigroup (MG) cross section processing procedure based on the CENTRM pointwise slowing down calculation is the primary procedure to process problem-dependent self-shielded MG cross sections and scattering matrices for neutron transport calculations.This procedure supports various cell-based geometries including slab, 1-D cylindrical, 1-D spherical and 2-D rectangular configurations and doubly heterogeneous particulate fuels. Recently, this procedure has been significantly improved to be applied to any advanced reactor analysis covering thermal and fast reactor systems, and to be comparable to continuous energy (CE) Monte Carlo calculations. Some reactivity bias and reaction rate differences have been observed compared with CE Monte Carlo calculations, and several areas for improvement have been identified in the SCALE-XSProc MG cross section processing: (1) resonance self-shielding calculations within the unresolved resonance range, (2) 10 eV thermal cut-off energy for the free gas model, (3) on-the-fly adjustments to the thermal scattering matrix, (4) normalization of the pointwise neutron flux, and (5) fine MG energy structure. This procedure ensures very accurate MG cross section processing for high-fidelity deterministic reactor physics analysis for various advanced reactor systems.

Kim, Kang Seog↗

Case Study of ISO/TS 6336-22 Micropitting Calculation

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for a method to calculate the risk of micropitting in gear sets. It assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. A sliding parameter is used to adjust the film thickness in the contact zone to the region of highest sliding, which is where micropitting has been observed. The permissible specific film thickness is best determined through experience or testing, but there is an option to estimate it based on the lubricant’s failure load stage in FZG testing. This paper is a case study of how the method behaves when applied to several gear sets and applications that have experienced micropitting in the field.

ENGINEERING,WIND ENERGY↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is also difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

Thermal Neutron Scattering Law for Beryllium Hydride and Critical Mass Calculations

The thermal neutron scattering law (TSL) for crystalline beryllium hydride (BeH 2 ) is developed from first-principles ab initio lattice dynamics calculations and the impact of neutron thermalization in this material on critical mass is estimated. BeH 2 has a body-centered orthorhombic crystal structure with 12 molecules per unit cell and a theoretical density of 0.755 g/cm 3 . The vibrational (phonon) densities of states for H and Be bound in BeH 2 are determined using VASP density functional theory and PHONON lattice dynamics calculations. The TSLs for H bound in BeH 2 , H(BeH 2 ), and Be bound in BeH 2 , Be(BeH 2 ), are then evaluated in the incoherent approximation from the calculated H and Be partial phonon density of states using FLASSH. Finally, critical mass as a function of 235 U loading density for bare and reflected BeH 2 moderated spheres is predicted from MC21 Monte Carlo neutron transport calculations using ENDF/B-VIII.0 cross sections and the H(BeH 2 ) and Be(BeH 2 ) TSL evaluations. Comparisons are made to water (H 2 O), polyethylene (CH 2 ), and beryllium oxide (BeO) as moderators. These critical mass predictions are a refinement upon the prior work by Rao and Srinivasan that neglected thermal neutron scattering effects. The minimum critical mass of a BeH 2 moderated assembly is estimated to be 0.207 kg 235 U for a 0.20 m thick BeO reflected sphere and 0.178 kg 235 U for a 0.40 m thick BeO reflected sphere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Abstract]

The SCALE code package offers several nuclear data libraries to support Monte Carlo (MC) transport, as well as MC-based derivation of $\kappa$ eff sensitivity and uncertainty (S/U) data. The CSAS sequence using the KENO MC code can utilize continuous-energy (CE) cross sections, or pre-generated multigroup (MG) cross section libraries. The use of MG libraries introduces bias into calculations in exchange for faster transport solutions. The TSUNAMI-3D sequence also utilizes KENO MC calculations. TSUNAMI-3D has two CE calculational methods: the Iterated Fission Probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications, e.g., fissionable and polyethylene reflectors

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be physically cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Pressure induced structural phase transition of OsB{sub 2}: First-principles calculations

Orthorhombic OsB{sub 2} was synthesized at 1000 deg. C and its compressibility was measured by using the high-pressure X-ray diffraction in a Diacell diamond anvil cell from ambient pressure to 32 GPa [R.W. Cumberland, et al. (2005)]. First-principles calculations were performed to study the possibility of the phase transition of OsB{sub 2}. An analysis of the calculated enthalpy shows that orthorhombic OsB{sub 2} can transfer to the hexagonal phase at 10.8 GPa. The calculated results with the quasi-harmonic approximation indicate that this phase transition pressure is little affected by the thermal effect. The calculated phonon band structure shows that the hexagonal P 6{sub 3}/mmc structure (high-pressure phase) is stable for OsB{sub 2}. We expect the phase transition can be further confirmed by the experimental work. - Abstract: Graphical Abstract Legend (TOC Figure): Table of Contents Figure Pressure induced structural phase transition from the orthorhombic structure to the hexagonal one for OsB{sub 2} takes place under 10.8 GPa (0 K), 10.35 GPa (300, 1000 K) by the first-principles predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗