Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

A Numerical Study of Cracks Appearance on Tungsten Surface After High Intense Pulsed Ion Beam Irradiation

Due to the outstanding physical properties, Tungsten has been proposed for use in the divertor of future fusion devices. However, tungsten shall face strong particle bombardment from the plasma, which causes severe damage to the material. The purpose of this work is to build such an accurate analytical model which can predict the damages in target material like crack production and propagation after high intense pulsed ion beam irradiation. Hence, a two-dimensional finite element method is used to study the effect of high intense pulsed ion beam on tungsten surface numerically. To judge temperature and stress distribution in material, thermal conduction model is combined with non-linear fracture mechanics model and J-Integral parameter is used as a criterion to judge the crack propagation. Simulation results reveal that different crack heights and sizes can affect the results and there is a critical depth for crack propagation. The model gives good results to real experimental observations and has potential applications for different intense pulsed electron/plasma beams and different target materials as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Development of Polarized Electron Sources - Physics and History

Polarized electron sources have been actively developed since about 1960. Six separate methods have been developed to provide useful polarized beams. We review the underlying physics and the history surrounding the development of these sources.

43 PARTICLE ACCELERATORS↗

Fluctuations of the orbital angular momentum of a laser beam, carrying an optical vortex, in the turbulent atmosphere

The evolution of the orbital angular momentum (OAM) of a Laguerre-Gaussian beam interacting with turbulent inhomogeneities of the atmosphere is studied theoretically. The integral representations are obtained for the OAM in terms of the distributions of the random intensity and random field of the permittivity of the medium, and also for OAM statistical characteristics in terms of corresponding correlation functions. It is found that the average OAM value is preserved during the propagation of the laser beam in a random medium. The dependence of the dispersion of OAM fluctuations on the atmospheric turbulence and beam parameters is calculated. It is shown that the dependence of the OAM dispersion on the initial angular momentum of the laser beam disappears in the case of very strong turbulence. (laser beams)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thin-Foil Heating with Intense Relativistic Electron Beams

Thin-metal foils are used in intense relativistic beam experiments for various purposes. In planning these experiments and analyzing the results it is often desirable to have an estimate of the temperature reached during the beam pulse. This can be deduced from an estimate of the energy deposited by the beam, and the specific heat capacity of the material, which depends on the temperature. The methodology for doing this is explained herein, and a metric for foil survivability under heating by an intense relativistic electron beam is suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physical performance and image optimization of megavoltage cone-beam CT

Megavoltage cone-beam CT (MVCBCT) is the most recent addition to the in-room CT systems developed for image-guided radiation therapy. The first generation MVCBCT system consists of a 6 MV treatment x-ray beam produced by a conventional linear accelerator equipped with a flat panel amorphous silicon detector. The objective of this study was to evaluate the physical performance of MVCBCT in order to optimize the system acquisition and reconstruction parameters for image quality. MVCBCT acquisitions were performed with the clinical system but images were reconstructed and analyzed with a separate research workstation. The geometrical stability and the positioning accuracy of the system were evaluated by comparing geometrical calibrations routinely performed over a period of 12 months. The beam output and detector intensity stability during MVCBCT acquisition were also evaluated by analyzing in-air acquisitions acquired at different exposure levels. Several system parameters were varied to quantify their impact on image quality including the exposure (2.7, 4.5, 9.0, 18.0, and 54.0 MU), the craniocaudal imaging length (2, 5, 15, and 27.4 cm), the voxel size (0.5, 1, and 2 mm), the slice thickness (1, 3, and 5 mm), and the phantom size. For the reconstruction algorithm, the study investigated the effect of binning, averaging and diffusion filtering of raw projections as well as three different projection filters. A head-sized water cylinder was used to measure and improve the uniformity of MVCBCT images. Inserts of different electron densities were placed in a water cylinder to measure the contrast-to-noise ratio (CNR). The spatial resolution was obtained by measuring the point-spread function of the system using an iterative edge blurring technique. Our results showed that the geometric stability and accuracy of MVCBCT were better than 1 mm over a period of 12 months. Beam intensity variations per projection of up to 35.4% were observed for a 2.7 MU MVCBCT acquisition. These variations did not cause noticeable reduction in the image quality. The results on uniformity suggest that the cupping artifact occurring with MVCBCT is mostly due to off-axis response of the detector and not scattered radiation. Simple uniformity correction methods were developed to nearly eliminate this cupping artifact. The spatial resolution of the baseline MVCBCT reconstruction protocol was approximately 2 mm. An optimized reconstruction protocol was developed and showed an improvement of 75% in CNR with a penalty of only 8% in spatial resolution. Using this new reconstruction protocol, large adipose and muscular structures were differentiated at an exposure of 9 MU. A reduction of 36% in CNR was observed on a larger (pelvic-sized) phantom. This study demonstrates that soft-tissue visualization with MVCBCT can be substantially improved with proper system settings. Further improvement is expected from the next generation MVCBCT system with an optimized megavoltage imaging beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical and Physical Simulation of the Fluid Flow in a Beam Blank Mold Fed Through the Center of the Web

Fluid flow inside a beam blank mold fed through a three-port SEN (two lateral ports and one bottom port), positioned at the center of the mold, has been investigated. Literature survey shows that this kind of configuration is not frequently used. It had been shown that it is possible to get a symmetrical flow with this configuration. The downward inclination of the ports should influence the transient fluid flow. The greater the downward inclination, the greater is the instability of the jet and of the interface between the immiscible fluids that simulate the slag/metal behavior. The flow characterization was made by dye dispersion, PIV technique, measurement of the meniscus oscillation using ultrasonic sensors, and CFD simulations. The slag/metal behavior was simulated using water and oils with different physical properties. The results from PIV as well as from observations of the water–oil interface have been used to validate the CFD simulations. Oils with density close to water resulted in more instability at the interface with entrainment starting from fluid flow rate of 125 L/min (equivalent to casting speed of 1 m/min). Decreasing the viscosity of slag (oils) and increasing the casting velocity (water flow rate) result in reduction of the interfacial stability.

36 MATERIALS SCIENCE↗

Measurement of surface stay times for physical adsorption of gases

A molecular beam time-of-flight technique is studied as a means of determining surface stay times for physical adsorption. The experimental approach consists of pulsing a molecular beam, allowing the pulse to strike an adsorbing surface and detecting the molecular pulse after it has subsequently desorbed. The technique is also found to be useful for general studies of adsorption under nonequilibrium conditions including the study of adsorbate-adsorbate interactions. The shape of the detected pulse is analyzed in detail for a first-order desorption process. For mean stay times, tau, less than the mean molecular transit times involved, the peak of the detected pulse is delayed by an amount approximately equal to tau. For tau much greater than these transit times, the detected pulse should decay as exp(-t/tau). However, for stay times of the order of the transit times, both the molecular speed distributions and the incident pulse duration time must be taken into account.

Wilmoth, R. G.↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

Enhancement of room temperature dislocation-related photoluminescence of electron irradiated silicon

In this paper, we have investigated the room temperature dislocation-related photoluminescence of electron irradiated silicon. It is found that high temperature annealing can enhance the D1 line emission measured at room temperature. The abnormal peak shift of D1 line on the dependence of temperatures reveals the reconstruction of D1 luminescence center. It is suggested that the high temperature annealing could cause the transformation of the dislocation-point defect structure, so that the D1 luminescence is enhanced and stabilized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photonic nanojet effect in multilayer micrometre-sized spherical particles

The spatial and amplitude characteristics of photonic nanojets from micrometre-sized composite particles consisting of a nucleus and several shells with different refractive indices were considered. We investigated the longitudinal and transverse dimensions of the photon jet as well as the dependence of its peak intensity on the optical contrast of the shells. It was shown that, by varying the refractive index of the neighbouring shells in composite spherical microparticles, it is possible to manipulate the photonic nanojet parameters, in particular, increase its length or raise the peak intensity of the photon flux. (interaction of laser radiation with matter. laser plasma)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental parameters for plasma wakefield acceleration in a narrow plasma column

Recent theoretical advancements propose multiple positron acceleration schemes in plasma wakefield acceleration (PWFA). One of the most promising ideas involves the creation of an electron-driven blowout wake within a finite-radius pre-ionized plasma column. This leads to the formation of an elongated region of sheath electrons at the closing of the first wake period capable of accelerating positrons while simultaneously providing a transverse focusing force. Additionally, the proposed scheme has shown to be a potential means of suppressing instabilities. We present an experimental opportunity to explore the narrow column PWFA at the Facility for Advanced Accelerator Experimental Tests II (FACET-II): the E333 experiment. As a pivotal first step towards achieving positron acceleration in PWFA, we have planned a precursor experiment utilizing the currently available single-bunch electron beam to study the physics of the narrow plasma PWFA scheme. We outline the feasible experimental parameters, including beam and ionization laser parameters, along with the required laser optics for the experiment. The primary observable signatures for this stage of the experiment are the final energy spectrum and transverse position of the electron bunch, anticipating reduced energy loss and enhanced beam guidance in the narrow plasma column compared to the nominal PWFA. Comprehensive simulations are used to detail our experimental plan.

Lee, Valentina [University of Colorado, Boulder, C↗

Current status of conceptual horizontal splitter design for FFA@CEBAF energy Upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations of the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. In order to control the beam parameters through these FFA arcs, horizontal splitters must be used. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

Maximizing Brightness in Photoinjectors

If the laser pulse driving photoinjectors could be arbitrarily shaped, the emittance growth induced by space charge effects could be totally compensated for. In particular, for RF guns the photo-electron distribution leaving the cathode should have a 3D-ellipsoidal shape. The emittance at the end of the injector could be as small as the cathode emittance. We explore how the emittance and the brightness can be optimized for photoinjector based on RF gun depending on the peak current requirements. Techniques available to produce those ideal laser pulse shapes are also discussed. If the laser pulse driving photoinjectors could be arbitrarily shaped, the emittance growth induced by space charge effects could be totally compensated for. In particular, for RF guns, the photo-electron distribution leaving the cathode should be close to a uniform distribution contained in a 3D-ellipsoid contour. For photo-cathodes which have very fast emission times, and assuming a perfectly uniform emitting surface, this could be achieved by shaping the laser in a pulse of constant fluence and limited in space by a 3D-ellipsoid contour. Simulations show that in such conditions, with the standard linear emittance compensation, the emittance at the end of the photo-injector beamline approaches the minimum value imposed by the cathode emittance. Brightness, which is expressed as the ratio of peak current over the product of the two transverse emittance, seems to be maximized for small charges. Numerical simulations also show that for very high charge per bunch (10nC), emittances as small as 2 mm-mrad could be reached by using 3D-ellipsoidal laser pulses in an S-Band gun. The production of 3D-ellipsoidal pulses is very challenging, but seems worthwhile the effort. We briefly discuss some of the present ideas and difficulties of achieving such pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics design of the injector source for ITER neutral beam injector (invited)

Two Neutral Beam Injectors (NBI) are foreseen to provide a substantial fraction of the heating power necessary to ignite thermonuclear fusion reactions in ITER. The development of the NBI system at unprecedented parameters (40 A of negative ion current accelerated up to 1 MV) requires the realization of a full scale prototype, to be tested and optimized at the Test Facility under construction in Padova (Italy). The beam source is the key component of the system and the design of the multi-grid accelerator is the goal of a multi-national collaborative effort. In particular, beam steering is a challenging aspect, being a tradeoff between requirements of the optics and real grids with finite thickness and thermo-mechanical constraints due to the cooling needs and the presence of permanent magnets. In the paper, a review of the accelerator physics and an overview of the whole R and D physics program aimed to the development of the injector source are presented.

43 PARTICLE ACCELERATORS↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗

Dependence of the Electron-Cloud Instability on the Beam Energy

The electron cloud (EC) can be formed in the beam pipe of a circular accelerator if the secondary emission yield (SEY) of the inner surface is larger than 1, and it can detrimentally affect the circulating beam. Understanding the underlying physics and defining the scaling laws of this effect is indispensable to steer the upgrade plans of the existing machines and the design of new ones. The single bunch EC instability (ECI) is shown to be strongly affected by the transverse beam size. Transversely, smaller beams going through an electron cloud generate higher electron peak densities and lower the intensity threshold to make the beam unstable. In particular, since higher energy beams have smaller transverse sizes (for equal normalized transverse emittances), the scaling of the ECI threshold with the beam energy turns out to be surprisingly unfavorable.

43 PARTICLE ACCELERATORS↗