Experimental investigation of nozzle critical flow characteristics of sodium vapor
Critical flow characteristics and pressure ratios of sodium vapor flowing through axisymmetrical convergent-divergent nozzle
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Critical flow characteristics and pressure ratios of sodium vapor flowing through axisymmetrical convergent-divergent nozzle
Silicon carbide (SiC) and silicon nitride (Si3N4) are proposed for applications in high temperature combustion environments containing water vapor. Both SiC and Si3N4 react with water vapor to form a silica (SiO2) scale. It is therefore important to understand the durability of SiC, Si3N4 and SiO2 in water vapor. Thermogravimetric analyses, furnace exposures and burner rig results were obtained for these materials in water vapor at temperatures between 1100 and 1450 C and water vapor partial pressures ranging from 0.1 to 3.1 atm. First, the oxidation of SiC and Si3N4 in water vapor is considered. The parabolic kinetic rate law, rate dependence on water vapor partial pressure, and oxidation mechanism are discussed. Second, the volatilization of silica to form Si(OH)4(g) is examined. Mass spectrometric results, the linear kinetic rate law and a volatilization model based on diffusion through a gas boundary layer are discussed. Finally, the combined oxidation and volatilization reactions, which occur when SiC or Si3N4 are exposed in a water vapor-containing environment, are presented. Both experimental evidence and a model for the paralinear kinetic rate law are shown for these simultaneous oxidation and volatilization reactions.
In spite of a superficial similarity with gas bubbles, the intimate coupling between dynamical and thermal processes confers to oscillating vapor bubbles some unique characteristics. This paper examines numerically the validity of some asymptotic-theory predictions such as the existence of two resonant radii and a limit size for a given sound amplitude and frequency. It is found that a small vapor bubble in a sound field of sufficient amplitude grows quickly through resonance and continues to grow thereafter at a very slow rate, seemingly indefinitely. Resonance phenomena therefore play a role for a few cycles at most, and reaching a limit size-if one exists at all-is found to require far more than several tens of thousands of cycles. It is also found that some small bubbles may grow or collapse depending on the phase of the sound field. The model accounts in detail for the thermo-fluid-mechanic processes in the vapor. In the second part of the paper, an approximate formulation valid for bubbles small with respect to the thermal penetration length in the vapor is derived and its accuracy examined, The present findings have implications for acoustically enhanced boiling heat transfer and other special applications such as boiling in microgravity.
Large size monolayer Molybdenum disulphide (MoS{sub 2}) was successfully grown by chemical vapor deposition method under an atmospheric pressure. The electrical transport properties of the fabricated back-gate monolayer MoS{sub 2} field effect transistors (FETs) were investigated under low temperatures; a peak field effect mobility of 59 cm{sup 2}V{sup −1}s{sup −1} was achieved. With the assist of Raman measurement under low temperature, this work identified the mobility limiting factor for the monolayer MoS{sub 2} FETs: homopolar phonon scattering under low temperature and electron-polar optical phonon scattering at room temperature.
In a sodium thermal electrochemical converter (Na-TEC), the transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle. This pumping can be typically achieved via capillary action. A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > π/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are required to model the coupled momentum and thermal transport processes within this porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is applied for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). The permeability of the porous structure is modeled using the Blaze-Kozeny expression, with an additional factor that accounts for this change in Kn. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented. The design of an experiment to validate the results from this modeling effort is also described. The main design features of the experimental set-up are presented, and the method used to measure the low sodium mass flowrates is discussed. Initial experimental results demonstrating sodium pumping for a range of temperatures (850K – 1150K) will be presented and compared against the model predictions. A number of challenges affecting the successful completion of this experiment will also be discussed. Primarily, the sodium vapor must be superheated to prevent condensation anywhere except within the porous structure. Other challenges include the requirement to keep the condensation interface above ~ 675K to prevent transition to a wetting regime, and the control of the transient heating rate so that vapor flows slower than the quasi steady-state mass flowrate, which would otherwise lead to a flooding condition that prevents pumping. Specific strategies used to address these challenges are presented, and the experimental procedures used to gather data are discussed.
The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is required to complete the thermodynamic cycle of a sodium thermal electrochemical converter (Na-TEC). A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > pi/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are used to model the coupled momentum and thermal transport processes within this non-wetting porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is also considered for situations where there is a substantial presence of non-condensable argon in the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. The main design features of an experimental set-up used to demonstrate this capillary pumping is also described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. Finally, several of the challenges with this experiment will be discussed, and specific strategies used to address these are presented.
The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.
Estimates of the effectiveness of an altimetric correction, and interpretation of sea level variability as a response to atmospheric forcing, both depend upon assuming that residual errors in altimetric corrections are uncorrelated among themselves and with residual sea level, or knowing the correlations. Not surprisingly, many corrections are highly correlated since they involve atmospheric properties and the ocean surface's response to them. The full corrections (including their geographically varying time mean values), show correlations between electromagnetic bias (mostly the height of wind waves) and either atmospheric pressure or water vapor of -40%, and between atmospheric pressure and water vapor of 28%. In the more commonly used collinear differences (after removal of the geographically varying time mean), atmospheric pressure and wave height show a -30% correlation, atmospheric pressure and water vapor a -10% correlation, both pressure and water vapor a 7% correlation with residual sea level, and a bit surprisingly, ionospheric electron content and wave height a 15% correlation. Only the ocean tide is totally uncorrelated with other corrections or residual sea level. The effectiveness of three ionospheric corrections (TOPEX dual-frequency, a smoothed version of the TOPEX dual-frequency, and Doppler orbitography and radiopositioning integrated by satellite (DORIS) is also evaluated in terms of their reduction in variance of residual sea level. Smooth (90-200 km along-track) versions of the dual-frequency altimeter ionosphere perform best both globally and within 20 deg in latitude from the equator. The noise variance in the 1/s TOPEX inospheric samples is approximately (11 mm) squared, about the same as noise in the DORIS-based correction; however, the latter has its error over scales of order 10(exp 3) km. Within 20 deg of the equator, the DORIS-based correction adds (14 mm) squared to the residual sea level variance.
Mercury vapor condensation in Rankine cycle power plant from pressure drops - thermodynamics
Static pressures of sodium vapor expansion with inert-gas-injection pressure-measuring technique
The secondary ion mass spectrometry and capacitance-voltage measurements have been used to study the mechanism of formation of the near-surface layer with a low concentration of uncompensated donors in n-GaP grown by vapor-phase epitaxy and subjected to heat treatment at different pressures of phosphorus vapors. The dependence of the thickness of the mentioned layer on the pressure of phosphorus vapors has a minimum at a pressure of (1.5 {+-} 0.5) x 10{sup 3} Pa. It is shown that at vapor pressures above the mentioned value, the interstitial P, which forms a deep electron trap, is a suitable candidate for the role of compensating acceptor. At low pressures, the probable compensating center is the P vacancy giving rise to a deep level with the energy Ec-(0.21 {+-} 0.01) eV. At 700 deg. C, the effective diffusivity of interstitial P is {approx}(3 {+-} 1) s- 10{sup -15} cm{sup 2}/s, while that of the P vacancy is {approx}(3 {+-} 1) x 10{sup -14} cm{sup 2}/s.
The results of studying the diffusion of Cr impurity in GaAs according to electrical measurements are reported. Dependences of the diffusion coefficient and limiting solubility of electrically active Cr atoms in GaAs on temperature (at fixed pressures of As vapors) and on the pressure of As vapors (at fixed temperatures) are determined. The dependence of the Cr diffusion coefficient in GaAs on the ratio between the volume of the sample under study to the volume of the cell in the case of pronounced deviation from the crystal's stoichiometry towards Ga excess is established. The obtained experimental data are analyzed on the basis of concepts concerning the dissociative mechanism of migration of Cr atoms in the GaAs crystal lattice; according to this mechanism, the diffusion coefficient depends heavily on the concentration of Ga vacancies.
The results of studying the diffusion of Cr impurity in GaAs according to electrical measurements are reported. Dependences of the diffusion coefficient and limiting solubility of electrically active Cr atoms in GaAs on temperature (at fixed pressures of As vapors) and on the pressure of As vapors (at fixed temperatures) are determined. The dependence of the Cr diffusion coefficient in GaAs on the ratio between the volume of the sample under study to the volume of the cell in the case of pronounced deviation from the crystal's stoichiometry towards Ga excess is established. The obtained experimental data are analyzed on the basis of concepts concerning the dissociative mechanism of migration of Cr atoms in the GaAs crystal lattice; according to this mechanism, the diffusion coefficient depends heavily on the concentration of Ga vacancies.
The Global Positioning System (GPS) enables positioning with a very small receiver. The signals transmitted by the GPS satellites are sensitive to the atmosphere and can be used to perform soundings with the radio occultation technique (e.g., Kursinski et al., 1997). The GPS signal can be converted to refractivity N via the Abel transform. The refractivity can then be related to atmospheric pressure P, temperature T, and water vapor partial pressure P (sub w) the GPS measurement, (between 0.5 and 1.5 km), its self-calibration, and it's nearly all-weather capabilities make it a good candidate for use in data assimilation systems (DAS) and numerical weather prediction (NWP). In order to demonstrate its usefulness in a DAS or NWP system, a first step is to assess its impact oil the analysis. A one-dimensional variational off-line analysis (1DVAR), meaning the data are not assimilated 'In the 3D DAS, constitutes a starting approach to which further enhancements can be made. The chosen observable to be analyzed in this study is the refractivity. One way to extract temperature (humidity) from the refractivity, is to assume a humidity (temperature) profile. One variable may then be retrieved without any a priori information. The 1DVAR approach used here resolves the ambiguity problem raised in the interpretation of these data. It enables retrieving these two atmospheric variables at a reasonable computing cost.
Tables of thermodynamic properties of nitrogen are presented for the liquid and vapor phases for temperatures from the freezing line to 2000K and pressures to 10,000 bar. The tables include values of density, internal energy, enthalpy, entropy, isochoric heat capacity, isobaric heat capacity velocity of sound, the isotherm derivative, and the isochor derivative. The thermodynamic property tables are based on an equation of state, P=P (p,T), which accurately represents liquid and gaseous nitrogen for the range of pressures and temperatures covered by the tables. Comparisons of property values calculated from the equation of state with measured values for P-p-T, heat capacity, enthalpy, latent heat, and velocity of sound are included to illustrate the agreement between the experimental data and the tables of properties presented here. The coefficients of the equation of state were determined by a weighted least squares fit to selected P-p-T data and, simultaneously, to isochoric heat capacity data determined by corresponding states analysis from oxygen data, and to data which define the phase equilibrium criteria for the saturated liquid and the saturated vapor. The vapor pressure equation, melting curve equation, and an equation to represent the ideal gas heat capacity are also presented. Estimates of the accuracy of the equation of state, the vapor pressure equation, and the ideal gas heat capacity equation are given. The equation of state, derivatives of the equation, and the integral functions for calculating derived thermodynamic properties are included.
An analysis of the time response of a propellant supply system operating in the blowdown mode is presented. The supply system is part of a pump-fed propulsion system intended for use on interplanetary spacecraft. As such, the supply system must provide the pump with propellant at sufficient pressure to avoid pump cavitation. The system, consisting of the tank, the liquid propellant, the pressurant gas and propellant vapor mixture, and a film layer separating the liquid and vapor phases, is analyzed using the principles of mass and energy conservation. The resulting set of ordinary, coupled, nonlinear differential equations for the thermodynamic state variables is integrated as an initial value problem. The resulting histories of total pressure, propellant vapor pressure, propellant liquid temperature, film layer temperature, propellant vapor/pressurant gas temperature, propellant vapor mass, and propellant liquid mass enable the calculation of the net positive suction head available at the pump which determines the viability of the pump-fed system concept when operated in the blowdown mode.
The nucleation and growth kinetics of single-wall carbon nanotubes in aligned arrays have been measured using fast pulses of acetylene and in situ optical diagnostics in conjunction with low pressure chemical vapor deposition (CVD). Increasing the acetylene partial pressure is shown to decrease nucleation times by three orders of magnitude, permitting aligned nanotube arrays to nucleate and grow to microns lengths within single gas pulses at high (up to 7 micron/s) peak growth rates and short ~ 0.5 s times.Low-frequency Raman scattering (> 10 cm-1) and transmission electron microscopy measurements show that increasing the feedstock flux in both continuous-CVD and pulsed-CVD shifts the product distribution to large single-wall carbon nanotube diameters > 2.5 nm. Sufficiently high acetylene partial pressures in pulsed-CVD appear to temporarily terminate the growth of the fastest- growing, small-diameter nanotubes by overcoating the more catalytically-active, smaller catalyst nanoparticles within the ensemble with non-nanotube carbon in agreement with a growth model. The results indicate that subsets of catalyst nanoparticle ensembles nucleate, grow, and terminate growth within different flux ranges according to their catalytic activity.
Self-organization of SiO{sub 2} nanodots is obtained by chemical vapor deposition out of hexamethyldisiloxane (HMDSO) and atmospheric pressure remote Ar-O{sub 2} plasma operating at high temperature (1200-1600 K). The dewetting of the film being deposited when it is still thin enough (<500 nm) is found to be partly responsible for this self-organization. When the coating becomes thicker (approx1 mum), and for relatively high contents in HMDSO, SiO{sub 2} walls forming hexagonal cells are obtained on a SiO{sub 2} sublayer. For thicker coatings (>1 mum), droplet-shaped coatings with a Gaussian distribution in thickness over their width are deposited. The coatings are submitted to high compressive stress. When it is relaxed, 'nestlike structures' made of nanoribbons are synthesized.