Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Simulation of vortex breakdown in tubes

The breakdown of a vortex flow in a tube is studied for a slightly diverging tube by means of a numerical solution of the Navier-Stokes equations for a quasi-stationary, incompressible, laminar flow. Numerical results are compared to experiments of Faler and Leibovich. The numerical data display features similar to the experimental results concerning breakdown conditions, location, and structure.

Menne, Stefan↗

Pressure drop and temperature rise in He II flow in round tubes, Venturi flowmeters and valves

Pressure drops in highly turbulent He II flow were measured in round tubes, valves, and Venturi flowmeters. Results are in good agreement with single-phase flow correlations for classical fluids. The temperature rise in flow in a round tube was measured, and found to agree well with predictions for isenthalpic expansion. Cavitation was observed in the venturis under conditions of low back pressure and high flow rate. Metastable superheating of the helium at the venturi throat was observed before the helium made a transition to saturation pressure.

Walstrom, P. L.↗

Development and experimental test of an analytical model of the orifice pulse tube refrigerator

An analytical model for the orifice pulse tube is developed, in which the system is described in terms of average enthalpy flow with such simplifying assumptions as an ideal gas and sinusoidal pressure variation. Phasor analysis is used to represent temperature, pressure, and mass-flow rate waves in vector form. The model predictions, namely, that the refrigeration power of a pulse-tube refrigerator is proportional to the average pressure, the pulse frequency, the mass-flow ratio, and the square of the dynamic pressure ratio, were verified by experimental measurements. It was found that, as a result of the simplifying assumptions, the magnitudes of the refrigeration power predicted by the model were between three and five times greater than experimental values.

Storch, Peter J.↗

Calibration-Tube Dewar

Container maintains reference material for gas chromatography at constant temperature for extended periods. Developed for holding peroxyacetylnitrate (PAN), material unstable at room temperature but stable at 0 degree C. Keeps vial of PAN at this temperature by immersing in mixture of water and ice. Perforated tube surrounds vial, protects from damage by ice but allows cold water to circulate around. Plug with handle removable so ice added through filler tube. O-rings seal joints around removable parts. Substances undergoing phase changes at other temperatures substituted for ice and water if different reference materials and storage temperatures used. Used on research aircraft collecting and analyzing air samples in troposphere and stratosphere.

Herlth, Donald B.↗

Development of a 39.5 GHz Karp traveling wave tube for use in space

A millimeter-wave TWT was developed using a dispersive, high-impedance forward wave interaction structure based on a ladder, with non-space-harmonic interaction, for a tube with high gain per inch and high efficiency. The 'Tunneladder' interaction structure combines ladder properties modified to accommodate Pierce gun beam optics on a radially magnetized PM focusing structure. The development involved the fabrication of chemically milled, shaped ladders diffusion brazed to each ridge of a double ridged waveguide. Cold-test data are presented, representing the omega-Beta and impedance characteristics of the modified ladder circuit These results were used in small and large-signal computer programs to predict TWT gain and efficiency. A laboratory model tube was designed and fabricated, including all major subassemblies.

Jacquez, A.↗

Transient hot-film sensor response in a shock tube

Shock tube experiments were performed to determine the response of a hot-film sensor, mounted flush on the side wall of a shock tube, to unsteady flow behind a normal shock wave. The present experiments attempt to isolate the response of the anemometer due only to the change in convective heat transfer at the hot-film surface. The experiments, performed at low supersonic shock speeds in air, are described along with the data acquisition procedure. The change in convective heat transfer is deduced from the data and the results are compared with those from transient boundary layer theory and another set of experimental results. Finally, a transient local heat transfer coefficient is formulated for use as the forcing function in a hot-film sensor instrument model simulation.

Roberts, A. S., Jr.↗

Use of an expansion tube to examine scramjet combustion at hypersonic velocities

Combustion testing at total enthalpy conditions corresponding to flight Mach numbers in excess of 12 requires the use of impulse facilities. The expansion tube is the only operational facility of its size which can provide these conditions without excessive oxygen dissociation or driver gas contamination. Expansion tube operation is described herein and the operational parameters having the largest impact on its performance are determined. These are: driver-to-intermediate chamber pressure ratio, driver gas molecular weight and specific heat ratio, and driver gas temperature. Increases in the last-named parameter will markedly affect the test section static pressure. Preliminary calibration tests are discussed and test gas conditions which have been achieved are presented. Calculated and experimental test times are compared and the parameters affecting test time are discussed. The direction of future work using this important experimental tool is indicated.

Rizkalla, O.↗

Thermodynamic and fluid mechanic analysis of rapid pressurization in a dead-end tube

Three models have been applied to very rapid compression of oxygen in a dead-ended tube. Pressures as high as 41 MPa (6000 psi) leading to peak temperatures of 1400 K are predicted. These temperatures are well in excess of the autoignition temperature (750 K) of teflon, a frequently used material for lining hoses employed in oxygen service. These findings are in accord with experiments that have resulted in ignition and combustion of the teflon, leading to the combustion of the stainless steel braiding and catastrophic failure. The system analyzed was representative of a capped off-high-pressure oxygen line, which could be part of a larger system. Pressurization of the larger system would lead to compression in the dead-end line, and possible ignition of the teflon liner. The model consists of a large plenum containing oxygen at the desired pressure (500 to 6000 psi). The plenum is connected via a fast acting valve to a stainless steel tube 2 cm inside diameter. Opening times are on the order of 15 ms. Downstream of the valve is an orifice sized to increase filling times to around 100 ms. The total length from the valve to the dead-end is 150 cm. The distance from the valve to the orifice is 95 cm. The models describe the fluid mechanics and thermodynamics of the flow, and do not include any combustion phenomena. A purely thermodynamic model assumes filling to be complete upstream of the orifice before any gas passes through the orifice. This simplification is reasonable based on experiment and computer modeling. Results show that peak temperatures as high as 4800 K can result from recompression of the gas after expanding through the orifice. An approximate transient model without an orifice was developed assuming an isentropic compression process. An analytical solution was obtained. Results indicated that fill times can be considerably shorter than valve opening times. The third model was a finite difference, 1-D transient compressible flow model. Results from the code show the recompression effect but predict much lower peak temperatures than the thermodynamic model.

Leslie, Ian H.↗

Computer simulation of Alfven resonance in a cylindrical, axially bounded flux tube

The resonant absorption of Alfven waves in an axially bounded cylindrical flux tube is investigated in a dissipative MHD simulation. It is found that in an axially bounded flux tube, in contrast to an infinite periodic model, the resonant frequency is nearly independent of the poloidal component of the magnetic field. This is a consequence of the 'ballooning' structure of the resonant Alfven waves. The scaling with resistivity and viscosity of the width of the resonance layer, the dissipation rate, and the time for steady state absorption to occur, are all in agreement with theory.

Strauss, H. R.↗

Streamtube analysis of supersonic combustion in an in-tube-scramjet

The chemical nonequilibrium flow around a projectile propelled by supersonic combustion inside a tube of premixed, stoichiometric H2-air mixture is examined using a quasi-one-dimensional flow model and a 28-reactions/13 species chemistry model. Two series of calculations have been performed; one at the initial pressure 5 atm and the other 0.01 atm. Three projectile Mach numbers, namely 8, 10 and 5 were used. The minimum cone angle of the projectile forebody needed for triggering ignition can be estimated from the results of the calculations. The numerical results also show that high initial pressure reduces the induction and reaction zones to a single detonation front, and thrust is produced by the high pressure in the combustor and nozzle. Low initial pressure lengthens the reaction zone. In all the cases, the momentum of the flow changes only slightly because the tube in which the projectile travels limits the area for the nozzle flow to expand.

Yip, T. Gary↗

Eddy-current inspection of shuttle heat exchanger tube welds

The goal of this project was to develop the system necessary to demonstrate in the laboratory that an eddy current system can inspect the tubes and welds described, screening for the existence of flaws equal in size to, or larger than, the target flaw. The laboratory system was to include the probe necessary to traverse the tubing, the electronics to drive (i.e., electrically excite) the probe and receive and process signals from it, a data display, data recording, and playback devices, and microprocessor software or firmware necessary to operate the system.

Dodd, Casius V.↗

Pulsed response of a traveling-wave tube

The consequence of frequency-domain multiple access (FDMA) channelization in a satellite communications system is that the ground- and space-based components are often required to operate at reduced output power to prevent the generation of distortions. However, the components of a time-division multiple access (TDMA) satellite system, such as a traveling-wave tube (TWT), can operate at the highest output power because the channelization technique is relatively insensitive to the distortions resulting from saturated operation. A Hughes 30-GHz TWT was tested to determine the suitability of such a device in a TDMA system. Testing was focused on the ability of the TWT to rise up to full power at the leading edge of TDMA bursts, which were simulated by a pulse train. A Wavetek model 8502A peak power meter was used to display and measure the pulsed signal waveform. Measurements of the TWT output signal rise time indicate that the TWT lengthened the rise time by 10 to 20 nsec. Imposing a modulator turn-on time that precedes the data burst by the TWT rise time is a logical approach to coordinating the traveling-wave tube amplifier and modulator specifications.

May, Brian D.↗

Convective response of a wall-mounted hot-film sensor in a shock tube

Shock tube experiments were performed in order to determine the response of a single hot-film element of a sensor array to transiently induced flow behind weak normal shock waves. The experiments attempt to isolate the response due only to the change in convective heat transfer at the hot-film surface mounted on the wall of the shock tube. The experiments are described, the results being correlated with transient boundary layer theory and compared with an independent set of experimental results. One of the findings indicates that the change in the air properties (temperature and pressure) precedes the air mass transport, causing an ambiguity in the sensor response to the development of the velocity boundary layer. Also, a transient, local heat transfer coefficient is formulated to be used as a forcing function in an hot-film instrument model and simulation which remains under investigation.

Roberts, A. Sidney, Jr.↗

ATLS: Catheter and tube placement

The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

Gosbee, John↗

The Marshall Space Flight Center Drop Tube Facility

The structural and instrumentation hardware and the improved experimental capabilities of a 105-m Drop Tube Facility are described. The structure is designed to provide a high-vacuum facility in a vertical orientation. The low-gravity environment obtained during free-fall and the containerless materials processing capabilities are discussed. Two furnaces, an electron-beam and an electromagnetic levitator, are used to melt metallic samples in a process environment ranging from 10 to the -6th torr to 1 atm. Specifics of the vacuum control and gas delivery systems are provided. The experimental instrumentation and data acquisition systems used to perform predrop and in-flight measurements of the melting and solidification process are discussed. Typical experimental results are presented as an indicator of the performance of the Drop Tube Facility.

Rathz, Thomas J.↗

Jet-A fuel evaporation analysis in conical tube injectors

A simple one-dimensional drop-life-history analysis and a multidimensional spray calculation using KIVA-II code are applied to the vaporization of Jet-A fuel in multiple tube injectors. Within the assumptions of the analysis, the one-dimensional results are useful for design purposes. The pressure-atomizer breakup models do not accurately predict the dropsize measured experimentally or deduced from the one-dimensional analysis. Cold flow visualization and dropsize measurements show that capillary wave breakup mechanism plays an important role in the spray angle and droplet impingement on the tube wall.

Lai, M.-C.↗

Average patterns of precipitation and plasma flow in the plasma sheet flux tubes during steady magnetospheric convection

Average patterns of plasma drifts and auroral precipitation in the nightside auroral zone were constructed during a steady magnetospheric convection (SMC) event on February 19, 1978. By comparing these patterns with the measurements in the midtail plasma sheet made by ISEE-1, and using the corresponding magnetic field model, the following features are inferred: (1) the concentration of the earthward convection in the midnight portion of the plasma sheet (convection jet); (2) the depleted plasma energy content of the flux tubes in the convection jet region; and (3) the Region-1 field-aligned currents generated in the midtail plasma sheet. It is argued that these three elements are mutually consistent features appearing in the process of ionosphere-magnetosphere interaction during SMC periods. These configurational characteristics resemble the corresponding features of substorm expansions (enhanced convection and 'dipolarized' magnetic field within the substorm current wedge) and appear to play the same role in regulating the plasma flow in the flux tubes connected to the plasma sheet.

Sergeev, V. A.↗

Convective response of a wall-mounted hot-film sensor in a shock tube

Shock tube experiments were performed in order to determine the response of a single hot-film element of a sensor array to transiently induced flow behind weak normal shock waves. The experiments attempt to isolate the response due only to the change in convective heat transfer at the hot-film surface mounted on the wall of the shock tube. The experiments are described, the results being correlated with transient boundary layer theory and compared with an independent set of experimental results. One of the findings indicates that the change in the air properties (temperature and pressure) precedes the air mass transport, causing an ambiguity in the sensor response to the development of the velocity boundary layer. Also, a transient, local heat transfer coefficient is formulated to be used as a forcing function in a hot-film instrument model and simulation which remains under investigation.

Roberts, A. S., Jr.↗