Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Conspicuity of target lights: The influence of flash rate and brightness

The stimulus characteristics of lights that might aid a pilot to see and avoid, by alerting him to a potential threat were studied. The relative conspicuity of foveally equated, point-source, steady and flashing lights of several brightnesses, seen against a star background was examined. From the subject's viewpoint, these target lights could appear anywhere within a large (40 deg horizontal by 35 deg vertical) field of view. The lights appeared at random time intervals while the subject was periodically distracted by a simulated cockpit task. The results indicate that correct target detection increases and reaction time decreases with increased target intensity. Steady lights are missed more frequently and acquired more slowly than flashing lights, but no significant differences are found among the wide range of flash rates employed. The intensity of the light has a greater effect on both detection and reaction time to steady lights than to flashing lights. These results are compared with results of other researchers who used targets which appeared at fixed locations. The longest reaction times were recorded to lights which appeared either at the extremes or at the very center of the visual field.

Connors, M. M.↗

Systematic study of target localization for bioluminescence tomography guided radiation therapy

Purpose: To overcome the limitation of CT/cone-beam CT (CBCT) in guiding radiation for soft tissue targets, the authors developed a spectrally resolved bioluminescence tomography (BLT) system for the small animal radiation research platform. The authors systematically assessed the performance of the BLT system in terms of target localization and the ability to resolve two neighboring sources in simulations, tissue-mimicking phantom, and in vivo environments. Methods: Multispectral measurements acquired in a single projection were used for the BLT reconstruction. The incomplete variables truncated conjugate gradient algorithm with an iterative permissible region shrinking strategy was employed as the optimization scheme to reconstruct source distributions. Simulation studies were conducted for single spherical sources with sizes from 0.5 to 3 mm radius at depth of 3–12 mm. The same configuration was also applied for the double source simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two self-illuminated sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single-source at 6 and 9 mm depth, two sources at 3 and 5 mm separation at depth of 5 mm, or three sources in the abdomen were also used to illustrate the localization capability of the BLT system for multiple targets in vivo. Results: For simulation study, approximate 1 mm accuracy can be achieved at localizing center of mass (CoM) for single-source and grouped CoM for double source cases. For the case of 1.5 mm radius source, a common tumor size used in preclinical study, their simulation shows that for all the source separations considered, except for the 3 mm separation at 9 and 12 mm depth, the two neighboring sources can be resolved at depths from 3 to 12 mm. Phantom experiments illustrated that 2D bioluminescence imaging failed to distinguish two sources, but BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single-source case at 6 and 9 mm depth, respectively. For the 2 sources in vivo study, both sources can be distinguished at 3 and 5 mm separations, and approximately 1 mm localization accuracy can also be achieved. Conclusions: This study demonstrated that their multispectral BLT/CBCT system could be potentially applied to localize and resolve multiple sources at wide range of source sizes, depths, and separations. The average accuracy of localizing CoM for single-source and grouped CoM for double sources is approximately 1 mm except deep-seated target. The information provided in this study can be instructive to devise treatment margins for BLT-guided irradiation. These results also suggest that the 3D BLT system could guide radiation for the situation with multiple targets, such as metastatic tumor models.

60 APPLIED LIFE SCIENCES↗

Management of the interplay effect when using dynamic MLC sequences to treat moving targets

Interplay between organ motion and leaf motion has been shown to generally have a small dosimetric impact for most clinical intensity-modulated radiation therapy treatments. However, it has also been shown that for some MLC sequences there can be large daily variations in the delivered dose, depending on details of patient motion or the number of fractions. This study investigates guidelines for dynamic MLC sequences that will keep daily dose variations due to the interplay between organ motion and leaf motion within 10%. Dose distributions for a range of MLC separations (0.2-5.0 cm) and displacements between adjacent MLCs (0-1.5 cm) were exported from ECLIPSE to purpose-written software, which simulated the dose distribution delivered to a moving target. Target motion parallel and perpendicular to the MLC motion was investigated for a range of amplitudes (0.5-4.0 cm), periods (1.5-10 s), and MLC speeds (0.1-3.0 cm/s) with target motions modeled as sin{sup 6}. Results were confirmed experimentally by measuring the dose delivered to an ion chamber array in a moving phantom for different MLC sequences. The simulation results were used to identify MLC sequences that kept dose variations within 10% compared to the dose delivered with no motion. The maximum allowable MLC speed, when target motion is parallel to the MLC motion, was found to be a simple function of target period and MLC separation. When the target motion is perpendicular to MLC motion, the maximum allowable MLC speed can be described as a function of MLC separation and the displacement of adjacent MLCs. These guidelines were successfully applied to two-dimensional motion, and a simple program was written to import MLC sequence files and evaluate whether the maximum daily dose discrepancy caused by the interplay effect will be larger than 10%. This software was experimentally evaluated, and found to conservatively predict whether a given MLC sequence could give large daily dose discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi frame radiography of supersonic water jets interacting with a foil target

Pulsed-power-driven underwater electrical explosion of cylindrical or conical wire arrays produces supersonic water jets that emerge from a bath, propagating through the air above it. Interaction of these jets with solid targets may represent a new platform for attaining materials at high pressure (>1010 Pa) conditions in a university-scale laboratory. However, measurements of the internal structure of such jets and how they interact with targets are difficult optically due to large densities and density contrasts involved. We utilized multi-frame x-ray radiographic imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility to explore the water jet and its interaction with a 50 μm thick copper foil placed a few mm from the surface of water. The jet was generated with a ∼130 kA-amplitude current pulse of ∼450 ns rise time applied to a conical wire array. X-ray imaging revealed a droplet-type structure of the jet with an average density of <400 kg/m3 propagating with a velocity of ∼1400 m/s. Measurements of deformation and subsequent perforation of the target by the jet suggested pressures at the jet–target interface of ∼5 × 109 Pa. The results were compared to hydrodynamic simulations for better understanding of the jet parameters and their interaction with the foil target. These results can be used in future research to optimize the platform, and extend it to larger jet velocities in the case of higher driving currents supplied to the wire array.

Physics↗

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studying the effect of drug-to-excipient ratio on drug release profile for drug coated balloons

Drug-coated balloons (DCB) have emerged as the alternative procedure for restenosis because of their ability to treat a variety of occlusion types with a uniform dose of anti-proliferative drugs. DCB are balloons coated with antiproliferative drugs encapsulated in a polymer matrix. There are several types of coating matrices used to produce DCB. In this study, the relationship between coating composition and drug release under physiologically relevant conditions was examined to understand how differences in coating composition impacts the drug transfer from the balloon surface to the simulated body fluids. To conduct the experiments, the balloons were coated with different paclitaxel (drug)-to-iopromide (excipient) ratios (3:1, 3:2 and 1:2) using an in-house developed micro-pipetting method. Scanning electron microscopy (SEM) images showed that the 3:1 PTX:IOP ratio produced a more uniform, crystalline microstructure with a thinner coating throughout the balloon surface compared to the other drug-to-excipient ratios. The 1:2 PTX:IOP ratio showed the least crystalline microstructure among the three ratios evaluated in this study. Three different drug elution conditions were tested. The amount of drug released to the medium was quantified by high performance liquid chromatography (HPLC). Our soaking study and submerge & deploy study showed that ~20% of the drug transferred to the target site under physiological conditions. A track and deploy method was performed using a “mock” artery, to simulate an in vitro environment. Coated balloons were passed through the mock artery to mimic tracking turns the balloon within the arteries during the angioplasty procedures. Seven elution samples were collected at different stages of the procedure. Finally, drug release results suggest that the higher excipient ratio helps to deliver the lipophilic drug to the target site under simulated conditions but causes higher drug loss during the balloon transfer process.

60 APPLIED LIFE SCIENCES↗

Uniform Distribution Technique for Neutrino Beam Scan Simulation

In Fermilab's neutrino facilities such as the Neutrinos at the Main Injector (NuMI) and the upcoming Long Baseline Neutrino Facility (LBNF), a proton beam strikes high-power target, producing positively and negatively charged pions and kaons. There is a need for detailed simulations in order to capture all particle interactions and beam propagation from protons on target to short-lived mesons decaying into muons and neutrinos. The generation of individual beam simulations is a resource-intensive and time-consuming process. In this paper, we describe a method through which many simulation samples with high statistics can be generated to study the effects of beam scan across a target for given beam configurations.

43 PARTICLE ACCELERATORS↗

Instrument design optimization with computational methods

Using Finite Element Analysis to approximate the solution of differential equations, two different instruments in experimental Hall C at the Thomas Jefferson National Accelerator Facility are analyzed. The time dependence of density uctuations from the liquid hydrogen (LH2) target used in the Q wea k experiment (2011-2012) are studied with Computational Fluid Dynamics (CFD) and the simulation results compared to data from the experiment. The 2.5 kW liquid hydrogen target was the highest power LH2 target in the world and the first to be designed with CFD at Jefferson Lab. The first complete magnetic field simulation of the Super High Momentum Spectrometer (SHMS) is presented with a focus on primary electron beam deflection downstream of the target. The SHMS consists of a superconducting horizontal bending magnet (HB) and three superconducting quadrupole magnets. The HB allows particles scattered at an angle of 5:5 deg to the beam line to be steered into the quadrupole magnets which make up the optics of the spectrometer. Without mitigation, remnant fields from the SHMS may steer the unscattered beam outside of the acceptable envelope on the beam dump and limit beam operations at small scattering angles. A solution is proposed using optimal placement of a minimal amount of shielding iron around the beam line.

43 PARTICLE ACCELERATORS↗

Standardization of accelerator irradiation procedures for simulation of neutron induced damage in reactor structural materials

Self-ion irradiation is widely used as a method to simulate neutron damage in reactor structural materials. Accelerator-based simulation of void swelling, however, introduces a number of neutron-atypical features which require careful data extraction and in some cases introduction of innovative irradiation techniques to alleviate these issues. We briefly summarize three such atypical features: defect imbalance effects, pulsed beam effects, and carbon contamination. The latter issue has just been recently recognized as being relevant to simulation of void swelling and is discussed here in greater detail. It is shown that carbon ions are entrained in the ion beam by Coulomb force drag and accelerated toward the target surface. Beam-contaminant interactions are modeled using molecular dynamics simulation. By applying a multiple beam deflection technique, carbon and other contaminants can be effectively filtered out, as demonstrated in an irradiation of HT-9 alloy by 3.5 MeV Fe ions.

Environmental Molecular Sciences Laboratory↗

SU-E-J-189: Credentialing of IGRT Equipment and Processes for Clinical Trials

Purpose: Current dosimetry phantoms used for clinical trial credentialing do not directly assess IGRT processes. This work evaluates a custom-built IGRT phantom for credentialing of multiple IGRT modalities and processes. Methods: An IGRT phantom was built out of a low-density body with two inserts. Insert A is used for the CT simulation. Insert B is used for the actual treatment. The inserts contain identical targets in different locations. Relative positions are unknown to the user. The user simulates the phantom (with insert A) as they would a patient, including marking the phantom. A treatment plan is created and sent to the treatment unit. The phantom (with insert B) is then positioned using local IGRT practice. Shifts (planned isocenter, if applicable, and final isocenter) are marked on the phantom using room lasers. The mechanical reproducibility of re-inserting the inserts within the phantom body was tested using repeat high-resolution CT scans. The phantom was tested at 7 centers, selected to include a wide variety of imaging equipment. Results: Mechanical reproducibility was measured as 0.5-0.9mm, depending on the direction. Approaches tested to mark (and transfer) simulation isocenter included lasers, fiducials and reflective markers. IGRT approaches included kV imaging (Varian Trilogy, Brainlab ExacTrac), kV CT (CT-on-rails), kV CBCT (Varian Trilogy, Varian Truebeam, Elekta Agility) and MV CT (Tomotherapy). Users were able to successfully use this phantom for all combinations of equipment and processes. IGRT-based shifts agreed with the truth within 0.8mm, 0.8mm and 1.9mm in the LR, AP, and SI directions, respectively. Conclusion: Based on these preliminary results, the IGRT phantom can be used for credentialing of clinical trials with an action level of 1mm in AP and LR directions, and 2mm in the SI direction, consistent with TG142. We are currently testing with additional institutions with different equipment and processes, including Cyberknife. This project was funded by the Cancer Prevention Research Institute of Texas.

60 APPLIED LIFE SCIENCES↗

Incident exercise in a virtual environment

An incident simulation system supports an incident exercise in a virtual environment. The incident simulation system accesses a simulation plan defining an incident within a theater of operation. The incident simulation system simulates the incident exercise by displaying, to a participant in the incident exercise, images representing what the participant would see within the theater of operation as the participant moves within the theater of operation. The incident simulation system further simulates the incident by generating incident data indicating effects of the incident at target locations and at target times as the participant moves within the theater of operation. The incident simulation system further simulates the incident by displaying to the participant images representing the user experience that a detector would provide based on the generated incident data.

97 MATHEMATICS AND COMPUTING↗

Incident exercise in a virtual environment

An incident simulation system supports an incident exercise in a virtual environment. The incident simulation system accesses a simulation plan defining an incident within a theater of operation. The incident simulation system simulates the incident exercise by displaying, to a participant in the incident exercise, images representing what the participant would see within the theater of operation as the participant moves within the theater of operation. The incident simulation system further simulates the incident by generating incident data indicating effects of the incident at target locations and at target times as the participant moves within the theater of operation. The incident simulation system further simulates the incident by displaying to the participant images representing the user experience that a detector would provide based on the generated incident data.

White, Gregory K.↗

Incident exercise in a virtual environment

An incident simulation system supports an incident exercise in a virtual environment. The incident simulation system accesses a simulation plan defining an incident within a theater of operation. The incident simulation system simulates the incident exercise by displaying, to a participant in the incident exercise, images representing what the participant would see within the theater of operation as the participant moves within the theater of operation. The incident simulation system further simulates the incident by generating incident data indicating effects of the incident at target locations and at target times as the participant moves within the theater of operation. The incident simulation system further simulates the incident by displaying to the participant images representing the user experience that a detector would provide based on the generated incident data.

White, Gregory K.↗

SU-F-T-211: Evaluation of a Dual Focusing Magnet System for the Treatment of Small Proton Targets

Purpose: To investigate magnetic focusing for small volume proton targets using a doublet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Monte Carlo computer simulations were performed using the Geant4 toolkit to compare dose depositions of proton beams transported through two focusing magnets or in their absence. Proton beams with energies of 127 MeV and initial diameters of 5, 8 and 10 mm were delivered through two identical focusing magnets similar to those currently in experimental use at Loma Linda University Medical Center. Analogous experiments used optimized configurations based on the simulation results. Dose was measured by a diode detector and Gafchromic EBT3 film and compared to simulation data. Based on results from the experimental data, an additional set of simulations was performed with an initial beam diameter of 18 mm and a two differing length magnets (40mm & 68mm). Results: Experimental data matched well with Monte Carlo simulations. However, under conditions necessary to produce circular beam spots at target depth, magnetically focused beams using two identical 40 mm length magnets did not meet all of our performance criteria of circular beam spots, improved peak to entrance (P/E) dose ratios and dose delivery efficiencies. The simulations using the longer 68 mm 2nd magnet yielded better results with 34% better P/E dose ratio and 20–50% better dose delivery efficiencies when compared to unfocused 10 mm beams. Conclusion: While magnetic focusing using two magnets with identical focusing power did not yield desired results, ongoing Monte Carlo simulations suggest that increasing the length of the 2nd magnet to 68 mm could improve P/E dose ratios and dose efficiencies. Future work includes additional experimental validation of the longer 2nd magnet setup as well as experiments with triplet magnet systems. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10-1).

60 APPLIED LIFE SCIENCES↗

Simulations of Turbulent Flows with Strong Shocks and Density Variations: (Final Report)

The target of this SciDAC Science Application was to develop a new capability based on high-order and high-resolution schemes to simulate shock-turbulence interactions and multi-material mixing in planar and spherical geometries, and to study Rayleigh-Taylor and Richtmyer-Meshkov turbulent mixing. These fundamental problems have direct application in high-speed engineering flows, such as inertial confinement fusion (ICF) capsule implosions and scramjet combustion, and also in the natural occurrence of supernovae explosions.

42 ENGINEERING↗

A geophysical shock and air blast simulator at the National Ignition Facility

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking Quantum Simulators Using Ergodic Quantum Dynamics

Here we propose and analyze a sample-efficient protocol to estimate the fidelity between an experimentally prepared state and an ideal target state, applicable to a wide class of analog quantum simulators without advanced spatiotemporal control. Our protocol relies on universal fluctuations emerging from generic Hamiltonian dynamics, which we discover in the present work. It does not require fine-tuned control over state preparation, quantum evolution, or readout capability, while achieving near optimal sample complexity: a percent-level precision is obtained with ~103 measurements, independent of system size. Furthermore, the accuracy of our fidelity estimation improves exponentially with increasing system size. We numerically demonstrate our protocol in a variety of quantum simulator platforms, including quantum gas microscopes, trapped ions, and Rydberg atom arrays. We discuss applications of our method for tasks such as multiparameter estimation of quantum states and processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bench Scale Testing of Next Generation Hollow Fiber Membrane Modules

This project seeks to develop a next generation membrane material (PI-2) for application in Air Liquide’s (AL) hybrid process. Combining the cold membrane operation with an integrated CO 2 Compression and Purification Unit (CPU) significantly reduces the overall cost of CO 2 capture. The proposed work will accelerate the membrane bundle fabrication, scale-up and performance validation of this new material. The proposed novel membrane development, combined with the results of the previous Cold Membrane Project, will provide the best opportunity for AL to meet the long term development targets of the DOE with respect to timing, cost, and performance for CO 2 capture. Our previous field test program (DE-FE0013163) showed promising results for the hybrid process utilizing the existing commercial AL membrane bundles (PI-1 material). The project work has also shown the potential for significant improvements through initial laboratory tests with the novel material (PI-2). The initial PI-2 results show a step-change in membrane permeance. This will enable further reduction in the cost of CO 2 capture by reducing the number of membrane modules and associated equipment in the system. In order to capture this value, however, the new material needs to be validated by field testing of large bundles, representative of commercial production. Lastly, a comprehensive evaluation of novel hybrid processes and costs needs to be completed to ensure optimal use of this improved material performance. The current project seeks to develop this next generation membrane to TRL 5 (approximately 600 - 1,000 Nm3/h flue gas, 350 - 600 scfm, 0.2 - 0.3 MWe equivalent). Air Liquide manufacturing methodology will be applied to fabricate prototype (4”) membrane modules from PI-2 material. Once the manufacturing methods prove reliable with the new material, and performance is demonstrated in line with expectation, 6” commercial scale bundles will be fabricated. Recognizing that a low cost membrane solution by itself may not meet DOE’s LCOE target for CO 2 capture, we will also perform simulation studies of novel hybrid processes in combination with the next generation membrane technology. This approach has the best potential for exceeding the DOE targets. The best evaluation of the new commercial units will be performance testing under real flue gas at the NCCC. Finally, a rigorous TEA, which incorporates the novel process studies and field performance, will be completed.

36 MATERIALS SCIENCE↗