Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Low Probability Tail Event Analysis and Mitigation in the BPA Control Area

This report investigated the uncertainties with the operations of the power system and their contributions to tail events, especially under high penetration of wind. A Bayesian network model is established to quantify the impact of these uncertainties on system imbalance. The framework is presented for a decision support tool, which can help system operators better estimate the need for balancing reserves and prepare for tail events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Explainable AI for Multivariate Time Series Pattern Exploration: Latent Space Visual Analytics With Temporal Fusion Transformer and Variational Autoencoders in Power Grid Event Diagnosis

Detecting and analyzing complex patterns in multivariate time-series data is crucial for decision-making in urban and environmental system operations. However, challenges arise from the high dimensionality, intricate complexity, and interconnected nature of complex patterns, which hinder the understanding of their underlying physical processes. Existing AI methods often face limitations in interpretability, computational efficiency, and scalability, reducing their applicability in real-world scenarios. This paper proposes a novel visual analytics framework that integrates two generative AI models, Temporal Fusion Transformer (TFT) and Variational Autoencoders (VAEs), to reduce complex patterns into lower-dimensional latent spaces and visualize them in 2D using dimensionality reduction techniques such as PCA, t-SNE, and UMAP with DBSCAN. These visualizations, presented through coordinated and interactive views and tailored glyphs, enable intuitive exploration of complex multivariate temporal patterns, identifying patterns’ similarities and uncover their potential correlations for a better interpretability of the AI outputs. The framework is demonstrated through a case study on power grid signal data, where it identifies multi-label grid event signatures, including faults and anomalies with diverse root causes. Additionally, novel metrics and visualizations are introduced to validate the models and assess the performance, efficiency, and consistency of latent maps generated by VAE, which have been utilized in prior studies for latent space cartography and used as a benchmark in this study, and the emerging TFT architecture under various configurations. These analyses provide actionable insights for model parameter tuning and reliability improvements. Comparative results highlight that TFT achieves shorter run times and superior scalability to diverse time-series data shapes compared to VAE. This work advances fault diagnosis in multivariate time series, fostering explainable AI to support critical system operations.

Explainable AI↗

Prognostic Analysis System and Methods of Operation

A prognostic analysis system and methods of operating the system are provided. In particular, a prognostic analysis system for the analysis of physical system health applicable to mechanical, electrical, chemical and optical systems and methods of operating the system are described herein.

MacKey, Ryan M. E.↗

Upgrading NASA/DOSE laser ranging system control computers

Laser ranging systems now managed by the NASA Dynamics of the Solid Earth (DOSE) and operated by the Bendix Field Engineering Corporation, the University of Hawaii, and the University of Texas have produced a wealth on interdisciplinary scientific data over the last three decades. Despite upgrades to the most of the ranging station subsystems, the control computers remain a mix of 1970's vintage minicomputers. These encompass a wide range of vendors, operating systems, and languages, making hardware and software support increasingly difficult. Current technology allows replacement of controller computers at a relatively low cost while maintaining excellent processing power and a friendly operating environment. The new controller systems are now being designed using IBM-PC-compatible 80486-based microcomputers, a real-time Unix operating system (LynxOS), and X-windows/Motif IB, and serial interfaces have been chosen. This design supports minimizing short and long term costs by relying on proven standards for both hardware and software components. Currently, the project is in the design and prototyping stage with the first systems targeted for production in mid-1993.

Ricklefs, Randall L.↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Demonstration of a Highly Efficient Solid Oxide Fuel Cell Power System Using Adiabatic Steam Reforming and Anode Gas Recirculation

Solid oxide fuel cells (SOFC) are currently being developed for a wide variety of applications because of their high efficiency at multiple power levels. Applications for SOFCs encompass a large range of power levels including 1-2 kW residential combined heat and power applications, 100-250 kW sized systems for distributed generation and grid extension, and MW-scale power plants utilizing coal. This paper reports on the development of a highly efficient, small-scale SOFC power system operating on methane. The system uses adiabatic steam reforming of methane and anode gas recirculation to achieve high net electrical efficiency. The anode exit gas is recirculated and all of the heat and water required for the endothermic reforming reaction are provided by the anode gas emerging from the SOFC stack. Although the single-pass fuel utilization is only about 55%, because of the anode gas recirculation the overall fuel utilization is up to 93%. The demonstrated system achieved gross power output of 1650 to 2150 watts with a maximum net LHV efficiency of 56.7% at 1720 watts. Overall system efficiency could be further improved to over 60% with use of properly sized blowers.

01 COAL, LIGNITE, AND PEAT↗

A scalable infrastructure for the performance analysis of passive target synchronization

Partitioned global address space (PGAS) languages combine the convenient abstraction of shared memory with the notion of affinity, extending multi-threaded programming to large-scale systems with physically distributed memory. However, in spite of their obvious advantages, PGAS languages still lack appropriate tool support for performance analysis, one of the reasons why their adoption is still in its infancy. Some of the performance problems for which tool support is needed occur at the level of the underlying one-sided communication substrate, such as the Aggregate Remote Memory Copy Interface (ARMCI). One such example is the waiting time in situations where asynchronous data transfers cannot be completed without software in- tervention at the target side. This is not uncommon on systems with reduced operating-system kernels such as IBM Blue Gene/P where the use of progress threads would double the number of cores necessary to run an application. In this paper, we present an extension of the Scalasca trace-analysis infrastructure aimed at the identification and quantification of progress-related waiting times at larger scales. We demonstrate its utility and scalability using a benchmark running with up to 32,768 processes.

performance analysis, event tracing, one-sided com↗

Modelling and control coordination scheme of a wind‐to‐hydrogen set for future renewable‐based power systems

New challenges regarding system stability and efficiency arise when power systems operate with a high penetration level of inverter‐based renewable sources (IBRSs) and few synchronous generators. Since IBRSs have been on the rise, to secure the stable operation of future power systems, IBRSs will be required to support systems without having to rely on remaining synchronous generators. Also, to efficiently manage the uncertainty of renewable production, power‐to‐gas technology can provide the required flexibility. This study proposes modelling and a control coordination scheme (CCS) of a wind‐to‐hydrogen (W2H) set to optimise electricity production from a variable‐speed wind turbine generator (WTG) while helping balance between supply and demand in a system. To achieve this, a grid‐forming (GFM) inverter‐based WTG is modelled and a set of electrolyser and fuel cell is integrated at the DC circuit of a GFM‐WTG to be coordinated. Furthermore, the CCS offers an opportunity to reduce the investment cost for deploying a W2H set by utilising the control capabilities of a WTG and reducing the need for an additional device. The performance of the proposed W2H set with the CCS was verified considering the variations in system load and wind speed by using Power System Computer Aided Design (PSCAD)/ElectroMagnetic Transients including Direct Current (EMTDC).

Kim, Jinho↗

Fast phase stabilization of a low frequency beat note for atom interferometry

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the {sup 87}Rb recoil frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involving the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EVIDENCE OF POSSIBLE SPIN-ORBIT MISALIGNMENT ALONG THE LINE OF SIGHT IN TRANSITING EXOPLANET SYSTEMS

Of the 26 transiting exoplanet systems with measurements of the Rossiter-McLaughlin (RM) effect, eight have now been found to be significantly spin-orbit misaligned in the plane of the sky (i.e., RM misalignment angle |{lambda}| {approx}> 30{sup 0} and inconsistent with {lambda} = 0{sup 0}). Unfortunately, the RM effect does not constrain the complement misalignment angle between the orbit of the planet and the spin of its host star along the line of sight (LOS). I use a simple model of stellar rotation benchmarked with observational data to statistically identify 10 exoplanet systems from a sample of 75 for which there is likely a significant degree of spin-orbit misalignment along the LOS: HAT-P-7, HAT-P-14, HAT-P-16, HD 17156, Kepler-5, Kepler-7, TrES-4, WASP-1, WASP-12, and WASP-14. All 10 systems have host stellar masses M {sub *} in the range 1.2 M {sub sun} {approx}< M {sub *} {approx}< 1.5 M {sub sun}, and the probability of this occurrence by chance is less than one in ten thousand. In addition, the planets in the candidate-misaligned systems are preferentially massive and eccentric. The coupled distribution of misalignment from the RM effect and from this analysis suggests that transiting exoplanets are more likely to be spin-orbit aligned than expected given predictions for a transiting planet population produced entirely by planet-planet scattering or Kozai cycles and tidal friction. For that reason, there are likely two populations of close-in exoplanet systems: a population of aligned systems and a population of apparently misaligned systems in which the processes that lead to misalignment or to the survival of misaligned systems operate more efficiently in systems with massive stars and planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Anticipatory Monitoring and Control of Complex Systems using a Fuzzy based Fusion of Support Vector Regressors

This paper places itself in the realm of anticipatory systems and envisions monitoring and control methods being capable of making predictions over system critical parameters. Anticipatory systems allow intelligent control of complex systems by predicting their future state. In the current work, an intelligent model aimed at implementing anticipatory monitoring and control in energy industry is presented and tested. More particularly, a set of support vector regressors (SVRs) are trained using both historical and observed data. The trained SVRs are used to predict the future value of the system based on current operational system parameter. The predicted values are then inputted to a fuzzy logic based module where the values are fused to obtain a single value, i.e., final system output prediction. The methodology is tested on real turbine degradation datasets. The outcome of the approach presented in this paper highlights the superiority over single support vector regressors. In addition, it is shown that appropriate selection of fuzzy sets and fuzzy rules plays an important role in improving system performance.

47 OTHER INSTRUMENTATION↗

Developing a Distributed Trust Model for Distributed Energy Resources

Electric power system operators can manage distribution system reliability by coordinating end customer usage of distributed energy resources. The end customers in this regard are Service Provisioning Customers, who provide their energy resources to a Grid Service Provider, which in turn dispatches large aggregations of distributed energy resources to provide reliable service to the power system.The security of this system relies upon information protection mechanisms, as described in IEEE 2030.5. However, in addition to preventive security measures, a monitoring function is required to ensure trustworthiness. Trust models are a method to detect and respond to both expected and unexpected behavior. Different trust models are required for various types and characteristics of each situation. This paper will describe the topics that must be considered when developing a trust model as it applies to distributed energy resources. The major contribution of this paper is the creation and application of a Distributed Trust Model applied to distributed energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Band Uncertainty Set Based Robust SCUC With Spatial and Temporal Budget Constraints

The dramatic increase of renewable energy resources in recent years, together with the long-existing load forecast errors and increasingly involved price sensitive demands, has introduced significant uncertainties into power systems operation. In order to guarantee the operational security of power systems with such uncertainties, robust optimization has been extensively studied in security-constrained unit commitment (SCUC) problems, for immunizing the system against worst uncertainty realizations. However, traditional robust SCUC models with single-band uncertainty sets may yield over-conservative solutions in most cases. This paper proposes a multi-band robust model to accurately formulate various uncertainties with higher resolution. By properly tuning band intervals and weight coefficients of individual bands, the proposed multi-band robust model can rigorously and realistically reflect spatial/temporal relationships and asymmetric characteristics of various uncertainties, and in turn could effectively leverage the tradeoff between robustness and economics of robust SCUC solutions. The proposed multi-band robust SCUC model is solved by Benders decomposition (BD) and outer approximation (OA), while taking the advantage of integral property of the proposed multi-band uncertainty set. In addition, several accelerating techniques are developed for enhancing the computational performance and the convergence speed. Numerical studies on a 6-bus system and the modified IEEE 118-bus system verify the effectiveness of the proposed robust SCUC approach for enhancing uncertainty modeling capabilities and mitigating conservativeness of the robust SCUC solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neural Lyapunov Control for Power System Transient Stability: A Deep Learning-Based Approach

We report that power system control and transient stability analysis play essential roles in secure system operation. Control of power systems typically involves highly nonlinear and complex dynamics. Most of the existing works address such problems with additional assumptions in system dynamics, leading to a requirement for a complete and general solution. This paper, therefore, proposes a novel control framework for various power system control and stability problems leveraging a learning-based approach. The proposed framework includes a two-module structure that iteratively and jointly learns the candidate Lyapunov function and control law via deep neural networks in a learning module. Meanwhile, it guides the learning procedure towards valid results satisfying Lyapunov conditions in a falsification module. The introduced termination criteria ensure provable system stability. This control framework is verified through several studies handling different types of power system control problems. The results show that the proposed framework is generalizable and can simplify the control design for complex power systems with the stability guarantee and enlarged region of attraction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Holistic Operations Planning System (HOPS)

Our research showed that combining low-level performance data from existing network monitoring tools is a viable and low-cost approach to gain insight on a network. The combined information can be used to evaluate purchasing decisions, support long-term planning, and visualize the network. These reports can help organizations create more efficient and reliable networks, and to more easily consolidate networks when two organizations merge.

Davis, Ryan↗