Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Study center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

An extended N-H bond, driven by a conserved second-order interaction, orients the flavin N5 orbital in cholesterol oxidase

The protein microenvironment surrounding the flavin cofactor in flavoenzymes is key to the efficiency and diversity of reactions catalysed by this class of enzymes. X-ray diffraction structures of oxidoreductase flavoenzymes have revealed recurrent features which facilitate catalysis, such as a hydrogen bond between a main chain nitrogen atom and the flavin redox center (N5). A neutron diffraction study of cholesterol oxidase has revealed an unusual elongated main chain nitrogen to hydrogen bond distance positioning the hydrogen atom towards the flavin N5 reactive center. Investigation of the structural features which could cause such an unusual occurrence revealed a positively charged lysine side chain, conserved in other flavin mediated oxidoreductases, in a second shell away from the FAD cofactor acting to polarize the peptide bond through interaction with the carbonyl oxygen atom. Double-hybrid density functional theory calculations confirm that this electrostatic arrangement affects the N-H bond length in the region of the flavin reactive center. We propose a novel second-order partial-charge interaction network which enables the correct orientation of the hydride receiving orbital of N5. The implications of these observations for flavin mediated redox chemistry are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

UC Davis Fuel Cell, Hydrogen, and Hybrid Vehicle (FCH2V) GATE Center of Excellence

This is the final report of the UC Davis Fuel Cell, Hydrogen, and Hybrid Vehicle (FCH2V) GATE Center of Excellence which spanned from 2005-2012. The U.S. Department of Energy (DOE) established the Graduate Automotive Technology Education (GATE) Program, to provide a new generation of engineers and scientists with knowledge and skills to create advanced automotive technologies. The UC Davis Fuel Cell, Hydrogen, and Hybrid Vehicle (FCH2V) GATE Center of Excellence established in 2005 is focused on research, education, industrial collaboration and outreach within automotive technology. UC Davis has had two independent GATE centers with separate well-defined objectives and research programs from 1998. The Fuel Cell Center, administered by ITS-Davis, has focused on fuel cell technology. The Hybrid-Electric Vehicle Design Center (HEV Center), administered by the Department of Mechanical and Aeronautical Engineering, has focused on the development of plug-in hybrid technology using internal combustion engines. The merger of these two centers in 2005 has broadened the scope of research and lead to higher visibility of the activity. UC Davis's existing GATE centers have become the campus's research focal points on fuel cells and hybrid-electric vehicles, and the home for graduate students who are studying advanced automotive technologies. The centers have been highly successful in attracting, training, and placing top-notch students into fuel cell and hybrid programs in both industry and government.

30 DIRECT ENERGY CONVERSION↗

Synthesis and X-ray diffraction study of [UO{sub 2}(NO{sub 3}){sub 2}(H{sub 2}O){sub 2}] {center_dot} 2C{sub 12}H{sub 18}O

The compound [UO{sub 2}(NO{sub 3}){sub 2}(H{sub 2}O){sub 2}] {center_dot} 2C{sub 12}H{sub 18}O was synthesized and studied by IR spectroscopy and X-ray diffraction. The structure consists of the neutral island groups [UO{sub 2}(NO{sub 3}){sub 2}(H{sub 2}O){sub 2}], which belong to the crystal-chemical group AB{sup 01}{sub 2}M{sup 1}{sub 2} (A = UO{sub 2}{sup 2+}, B{sup 01} = NO{sub 3}{sup -}, M{sup 1} = H{sub 2}O) of uranyl complexes, and 1-adamantyl methyl ketone molecules. The characteristic features of the association of the complexes [UO{sub 2}(NO{sub 3}){sub 2}(H{sub 2}O){sub 2}] and 1-adamantyl methyl ketone molecules in the crystal structure via hydrogen bonds are considered with the use of Voronoi-Dirichlet polyhedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clinical Long-Term Outcome and Reinterventional Rate After Uterine Fibroid Embolization with Nonspherical Versus Spherical Polyvinyl Alcohol Particles

PurposeThis study was designed to evaluate the long-term clinical outcome and frequency of reinterventions in patients with uterine fibroids treated with embolization at a single center using polyvinyl alcohol microparticles.MethodsThe study included all patients with symptomatic uterine fibroids treated with uterine fibroid embolization (UFE) with spherical (s-PVA) and nonspherical (ns-PVA) polyvinyl alcohol microparticles during the period January 2001 to January 2011. Clinical success and secondary interventions were examined. Hospital records were reviewed during follow-up, and symptom-specific questionnaires were sent to all patients.ResultsIn total, 515 patients were treated with UFE and 350 patients (67 %) were available for long-term clinical follow-up. Median time of follow-up was 93 (range 76–120.2) months. Eighty-five patients (72 %) had no reinterventions during follow-up in the group embolized with ns-PVA compared with 134 patients (58 %) treated with s-PVA. Thirty-three patients (28 %) underwent secondary interventions in the ns-PVA group compared with 98 patients (42 %) in s-PVA group (χ{sup 2} test, p < 0.01).ConclusionsSpherical PVA particles 500–700 µm showed high reintervention rate at long-term follow-up, and almost one quarter of the patients underwent secondary interventions, suggesting that this type of particle is inappropriate for UFE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of lift-to-drag ratio in pilot rating of the HL-20 landing task

A man-in-the-loop simulation study of the handling qualities of the HL-20 lifting-body vehicle was made in a fixed-base simulation cockpit at NASA Langley Research Center. The purpose of the study was to identify and substantiate opportunities for improving the original design of the vehicle from a handling qualities and landing performance perspective. Using preliminary wind-tunnel data, a subsonic aerodynamic model of the HL-20 was developed. This model was adequate to simulate the last 75-90 s of the approach and landing. A simple flight-control system was designed and implemented. Using this aerodynamic model as a baseline, visual approaches and landings were made at several vehicle lift-to-drag ratios. Pilots rated the handling characteristics of each configuration using a conventional numerical pilot-rating scale. Results from the study showed a high degree of correlation between the lift-to-drag ratio and pilot rating. Level 1 pilot ratings were obtained when the L/D ratio was approximately 3.8 or higher.

Jackson, E. B.↗

Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up to 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Intraluminal Recanalization of Long, Chronic Superficial Femoral and Popliteal Occlusions Using the Frontrunner XP CTO Device: A Single-Center Experience

The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 {+-} 8.8 years). Sixty-seven percent of patients had severe claudication. Critical lower limb ischemia with rest pain or minor tissue loss was present in three and eight patients, respectively. All the lesions were considered complex (TASC B, C, and D); 68% of the lesions were heavily calcified. The mean lesion length was 17.6 cm (range, 10-42 cm). The initial attempt to cross the occlusion with the CTO guidewire V18 was unsuccessful in 26 of 76 limbs (34.26%). A secondary attempt using the Frontrunner catheter (crossover approach, 27%; antegrade, 73%) performed in all 26 failed cases was successful in 17 limbs (65.38%), increasing the technical success rate to 88.12%. The main reasons for failure with the Frontrunner were inability to cross the lesion due to heavy calcification (six of nine) and inability to re-enter the true lumen after subintimal passage of the occluded segment (three of nine). The mean fluoroscopy time was 22.9 min. Minor complications included one distal extension of the dissection with involvement of the first popliteal segment and one perforation in the occluded segment. No major complications were seen. In conclusion, recanalization with the Frontrunner CTO catheter is a simple and safe method with a high technical success rate in the endovascular treatment of long superficial femoral artery occlusions and should be an alternative method after guidewire failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Antibiotic Prophylaxis for Percutaneous Radiofrequency Ablation (RFA) of Primary Liver Tumors Necessary? Results From a Single-Center Experience

PurposeThe purpose of this study was to evaluate need for antibiotic prophylaxis for radiofrequency ablation (RFA) of liver tumors in patients with no significant co-existing risk factors for infection.Materials and MethodsFrom January 2004 to September 2013, 83 patients underwent 123 percutaneous RFA procedures for total of 152 hepatocellular carcinoma (HCC) lesions. None of the patients had pre-existing biliary enteric anastomosis (BEA) or any biliary tract abnormality predisposing to ascending biliary infection or uncontrolled diabetes mellitus. No pre- or post-procedure antibiotic prophylaxis was provided for 121 procedures. Data for potential risk factors were reviewed retrospectively and analyzed for the frequency of infectious complications, including abscess formation.ResultsOne patient (1/121 (0.8 %) RFA sessions) developed a large segment 5 liver abscess/infected biloma communicating with the gallbladder 7 weeks after the procedure, successfully treated over 10 weeks with IV and PO antibiotic therapy and percutaneous catheter drainage. This patient did not receive any antibiotics prior to RFA. During the procedure, there was inadvertent placement of RFA probe tines into the gallbladder. No other infectious complications were documented.ConclusionThese data suggest that the routine use of prophylactic antibiotics for liver RFA is not necessary in majority of the patients undergoing liver ablation for HCC and could be limited to patients with high-risk factors such as the presence of BEA or other biliary abnormalities, uncontrolled diabetes mellitus, and large centrally located tumors in close proximity to central bile ducts. Larger randomized studies are needed to confirm this hypothesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Shunt Fraction prior to Yttrium-90 Radioembolization Predicts Survival in Patients with Neuroendocrine Liver Metastases: Single-Center Prospective Analysis

ObjectiveTo investigate survival outcomes following radioembolization with Yttrium-90 (Y90) for neuroendocrine tumor liver metastases (NETLMs). This study was designed to assess the efficacy of Y90 radioembolization and to evaluate lung shunt fraction (LSF) as a predictor for survival.MethodsA single-center, prospective study of 44 consecutive patients (median age: 58.5 years, 29.5 % male) diagnosed with pancreatic (52.3 %) or carcinoid (47.7 %) NETLMs from 2006 to 2012 who underwent Y90 radioembolization was performed. Patients’ baseline characteristics, including LSF and median overall survival (OS) from first Y90 radioembolization, were recorded and compared between patients with high (≥10 %) and low (<10 %) LSF. Baseline comparisons were performed using Fisher’s exact tests for categorical and Mann–Whitney U test for continuous variables. Survival was calculated using the Kaplan–Meier method. Univariate (Wilcoxon rank-sum test) and multivariate analyses (Cox Proportional Hazard Model) for risk factor analysis were performed.ResultsThere was no statistically significant difference in age, gender, race, tumor properties, or previous treatments between patients with high (n = 15) and low (n = 29) LSF. The median OS was 27.4 months (95 %CI 12.73–55.23), with 4.77 months (95 %CI 2.87–26.73) for high and 42.77 months (95 %CI 18.47–59.73) for low LSF (p = 0.003). Multivariate analysis identified high LSF (p = 0.001), total serum bilirubin >1.2 mg (p = 0.016), and lack of pretreatment with octreotide (p = 0.01) as independent prognostic factors for poorer survival. Tumor type and total radiation dose did not predict survival.ConclusionsLSF ≥10 %, elevated bilirubin levels, and lack of pretreatment with octreotide were found to be independent prognostic factors for poorer survival in patients with NETLMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Treatment Strategy for Primary Budd–Chiari Syndrome with Both Inferior Vena Cava and Hepatic Vein Involvement: Patients from Two Centers in China

Objective: This retrospective study evaluated interventional treatments (recanalization, balloon dilation, and/or stent placement) for Budd–Chiari syndrome (BCS), caused by combined obstruction of the inferior vena cava (IVC) and hepatic veins (HVs). Methods: Before and after interventional therapy, patients with BCS (n = 162; asymptomatic 105.2 ± 103.3 mo; follow-up 15 [6–24] mo) underwent imaging studies (color Doppler ultrasound, CT, or MRI), and inferior vena cavography and manometry. Venous lesions were characterized by occlusion features, and presence of thrombosis and peripheral collateral vessels. Results: One, 2, and 3 main HV occlusions were observed, respectively, in 25 (15.4%), 61 (37.7%), and 76 (46.9%) patients. Eighty-three (51.2%), 98 (60.5%), and 104 (64.2%) patients had, respectively, large accessory HVs, venous collaterals formed between the HVs, or venous communicating branches between the HV and the peritoneal veins. The middle, left, and right HV was patent in 32 (19.8%), 35 (21.6%), and 44 (27.2%) patients. Recanalization of both hepatic and caval occlusions was successful in 96% (51/53) of those attempted; recanalization of IVC occlusion was successful in 97% (106/109). Among 157 patients successfully treated, 146 were cured and 11 showed clinical improvement. Clinical symptoms were relieved in 82.4% after the initial intervention, and 94.2% after the second intervention. Conclusion: Recanalization and balloon angioplasty was effective for the management of BCS with concurrent HV and IVC occlusions. The majority of patients required only IVC recanalization. The outcome of patients treated only by IVC intervention was similar to that of patients given combined HV and IVC intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Sentinel Lymph Node Biopsy Using Indocyanine Green Fluorescence Plus Radioisotope Method Compared With the Radioisotope-Only Method for Breast Cancer Patients After Neoadjuvant Chemotherapy: A Prospective, Randomized, Open-Label, Single-Center Phase 2 Trial

Background: This study aimed to compare the sentinel lymph node (SLN) identification rates for breast cancer patients after neoadjuvant chemotherapy (NAC) between the dual method (DM) of indocyanine green fluorescence (ICG-F) plus a radioisotope (RI) and RI alone. Methods: This randomized study enrolled 130 patients who received NAC for breast cancer and 122 patients who received SLN biopsy (SLNB) using either DM (n = 58) or RI only (n = 64). The study compared the identification rate, number of SLNs, and detection time of SLNB. Results: Among the 122 patients, 113 (92.6%) were clinically node-positive before NAC. The SLN identification rate was 98.3% in the DM group and 93.8% in the RI group (p = 0.14). The DM group and the RI group were similar in the average number of SLNs (2.2 ± 1.13 vs. 1.9 ± 1.33; p = 0.26) and the time to detection of the first SLN (8.7 ± 4.98 vs. 8.3 ± 4.31 min; p = 0.30). In the DM group, transcutaneous lymphatic drainage was visualized by fluorescence imaging for 65.5% (38 of 58) of the patients. The SLN identification rate was 94.7% using ICG-F and 93% using RI (p = 0.79). During and after the operation, no complications, including allergic reactions or skin necrosis, occurred. Conclusions: This study is the first randomized trial to use ICG-F for SLNB in breast cancer patients after NAC. The DM including ICG-F could be a feasible and safe method for SLNB in initially node-positive breast cancer patients with NAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Energy Efficiency Potential of Cloud-Based Software: A U.S. Case Study

The energy use of data centers is a topic that has received much attention, given that data centers currently account for 1-2% of global electricity use. However, cloud computing holds great potential to reduce data center energy demand moving forward, due to both large reductions in total servers through consolidation and large increases in facility efficiencies compared to traditional local data centers. However, analyzing the net energy implications of shifts to the cloud can be very difficult, because data center services can affect many different components of society’s economic and energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LAMP Manufacturing Survey [Slides]

The LANL Accelerator Strategy Office (ASO) requires the support of AOT-MDE to perform a trade study on the current manufacturing capabilities required to modernize the Los Alamos Neutron Science Center (LANSCE). The purpose of the study will be to identify and potentially minimize cost and schedule risks that could impact the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

Review of Kaufman thruster development at the Lewis Research Center, 1973

Two thruster sizes are studied. One, a small 5-cm or 8-cm size is for spacecraft station keeping. The other, 30-cm (130 mN thrust), is for a thruster array to do primary solar electric propulsion. A 5-cm thruster (1.8 mN) has recently completed 9715 hr of life testing. Use of dished grids in the 30-cm thruster has increased beam current from 2 to 5 A. The total thrust system mass is compared for present small thrusters at different operating conditions for station keeping of synchronous satellites.

Kerslake, W. R.↗