EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Preparation of a membrane-sealed cell for studying catalyst nanoparticles in flowing gas with high vacuum x-ray photoelectron spectrometer

Here a sealing-style x-ray photoelectron spectroscopy study of the surface of a 1.0 wt. %Ni/TiO2 nanoparticle catalyst in a flowing mixture of CO and O2 at 1 bar was performed with a graphene membrane-sealed Si3N4 window-based miniature cell. We report the details on how a commercial Si3N4 window is modified before assembling a graphene membrane, how single-layer graphene membranes are transferred from their metal supports to the modified Si3N4 window, how a modified Si3N4 window covered with a double-layer graphene membrane is assembled onto a blank cell cap, how a nanoparticle catalyst is introduced to the cell cap and then the cell cap is installed onto a cell body to form a complete reaction cell, and how a complete cell is interfaced with a high vacuum chamber of an XPS system before an XPS study of 1.0 wt. %Ni/TiO2 catalyst surface in a flowing mixture for 0.2 bar CO and 0.8 bar O2 is performed. How the characterization of a catalyst using this type of graphene membrane-sealed Si3N4 window-based miniature cell is relevant to the finding of the actual surface chemistry of a catalyst during catalysis is discussed.

Instruments & Instrumentation↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of a Doppler spectrometer for 102 m/s cross-field flows in tokamak divertors

The cross-field transport in the scrape-off-layers (SOLs) and divertors in tokamaks is of a similar size to the poloidal component of the parallel flow, thereby significantly impacting the plasma transport there. However, its direct observation has been challenging because the drift velocity (102–103 m/s) is significantly below the detection limit of conventional diagnostics. To realize cross-field ion flow measurement, a variety of systematic uncertainties in the system must be narrowed down. Here, we develop a conceptual design of the Doppler spectrometry that enables us to measure the impurity flows with 102-m/s accuracy based on an in situ wavelength-calibration technique developed in the astrophysics field, the iodine-cell method. We discuss its properties and applicability. In particular, the scaling relation between wavelength accuracy and various spectroscopic parameters is newly presented, which suggests the high importance of the wavelength resolution of the system. Based on transport simulations for the JT-60SA divertor, the feasibility of the system is assessed.

Fujii, Keisuke↗

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗

On the possibility of designing a high-resolution heterodyne spectrometer for near-IR range on the basis of a tunable diode laser

The results of heterodyning of broadband radiation in the near-IR range are presented. A stabilised DFB laser was used as a local oscillator, while the role of a broadband radiation source was played by another DFB laser, excited by the pump current below its threshold value. A fibre-optical Y-coupler based on the single-mode silica fibre served as a diplexer. The radiation mixed in the singlemode fibre was incident on the photodetector, the role of which was played by a p - i - n photodiode. The signal from the photodiode was amplified by the preamplifier with the feedback resistance 240 k{Omega} and the bandwidth {approx}1 MHz and then digitised using a 16-digit ADC. The frequency scanning was implemented via the variation of the local oscillator frequency. The developed registration system provides the sensitivity {approx}1.4 % of the shot noise value at the acquisition time {approx}40 min.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron DENSITY of active region outflows measured by the EUV imaging spectrometer on board HINODE

In order to better understand the nature of active region outflows, the electron density was measured by using a density-sensitive line pair, Fe xiv 264.78 Å/274.20 Å. Because coronal line profiles of the outflow region are composed of a major component with a Doppler shift of ⩽10 km s{sup −1} and a minor component (enhanced blue wing, EBW) blueshifted by up to 100 km s{sup −1}, we extracted EBW from the line profiles through double-Gaussian fitting. We tried applying the simultaneous fitting to those two Fe xiv lines with several physical restrictions. Electron density for both components (n{sub Major} and n{sub EBW}, respectively) was calculated by referring to the theoretical intensity ratio as a function of electron density as per the CHIANTI database. We studied six locations in the outflow regions around NOAA AR10978. The average electron density was n{sub Major}=10{sup 9.16±0.16} cm{sup −3} and n{sub EBW}=10{sup 8.74±0.29} cm{sup −3}. The magnitude relationship between n{sub Major} and n{sub EBW} was the opposite in the eastern and western outflow regions. The column depth was also calculated for each component, which leads to the result that the outflows possess only a small fraction (∼0.1) in the eastern region, whereas they dominate over the major component in the line profiles by a factor of five in the western region. When taking into account the extended coronal structures, the western region can be thought to represent the mass leakage. In contrast, we suggest a possibility that the eastern region actually contributes to mass supply to coronal loops.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the photon spectrometer PHOS of the ALICE experiment

The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at √s = 13 TeV. After applying all corrections, the achieved mass resolutions for π 0 and η mesons for p T > 1.7 GeV/c are σ m π0 = 4.56 ± 0.03 MeV/c 2 and σ m η = 15.3 ± 1.0 MeV/c 2 , respectively.

47 OTHER INSTRUMENTATION↗