Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

CLM5 Simulations of Soil Moisture and Grain Carbon for CONUS at 0.125 degrees

This dataset provides 0.125° gridded simulations of soil moisture and crop grain carbon for the Contiguous United States (CONUS), generated using the Community Land Model version 5 (CLM5) with the biogeochemistry module enabled. The data covers a historical baseline (1980–2015) and mid-century future projections (2020–2055). Future projections are organized into two sets of scenarios to distinguish the impacts of different drivers: (1) Atmospheric Only (ATM-only): These scenarios apply future atmospheric forcings while holding land use and land cover change (LULCC) at historical baseline levels. The atmospheric forcings represent moderately versus severely hotter/drier atmospheric conditions (dynamically downscaled perturbed thermodynamics simulations based on CMIP6 SSP245 and SSP585 warming signals), each with cooler versus hotter Earth System Model temperature sensitivity instantiations. These scenarios are identified in the file names as atm45cooler, atm45hotter, atm85cooler, and atm85hotter. (2) Coupled Atmospheric and Land-Use (LAND+ATM): These scenarios apply future atmospheric forcing together with future LULCC by pairing atmospheric pathways with lower versus higher population/economic growth scenarios representing Shared Socioeconomic Pathways 3 and 5 (SSP3 and SSP5). These scenarios are identified in the file names as atm45cooler_ssp3, atm45hotter_ssp3, atm45cooler_ssp5, atm45hotter_ssp5, atm85cooler_ssp3, atm85hotter_ssp3, atm85cooler_ssp5, and atm85hotter_ssp5. Please refer to the README file for detailed information on file structure, variables, units, and data formats.

Yao, Lili [Pacific Northwest National Laboratory] ↗

CLM5 Simulations of Soil Moisture and Gross Primary Productivity for CONUS at 0.125 degrees

This dataset provides 0.125-degree gridded simulations of soil moisture and gross primary productivity (GPP) for the Contiguous United States (CONUS), generated using the Community Land Model version 5 (CLM5) with the biogeochemistry module enabled. The data covers a historical baseline (1980-2015) and mid-century future projections (2020-2055). Future projections are organized into two sets of scenarios to distinguish the impacts of different drivers: (1) Atmospheric Only (ATM): These scenarios apply future atmospheric forcings while holding land use and land cover (LULC) at historical baseline levels. The atmospheric forcings represent moderately versus severely hotter/drier atmospheric conditions (dynamically downscaled perturbed thermodynamics simulations based on CMIP6 SSP245 and SSP585 warming signals), each with cooler versus hotter Earth System Model temperature sensitivity instantiations. These scenarios are identified in the folder names as rcp45_cooler_near, rcp45_hotter_near, rcp85_cooler_near, and rcp85_hotter_near. (2) Coupled Atmospheric and Land-Use (LAND+ATM): These scenarios apply future atmospheric forcing together with future LULC by pairing atmospheric pathways with lower versus higher population/economic growth scenarios representing Shared Socioeconomic Pathways 3 and 5 (SSP3 and SSP5). These scenarios are identified in the file names as ssp3_rcp45_cooler_near, ssp3_rcp45_hotter_near, ssp5_rcp85_cooler_near, and ssp5_rcp85_hotter_near. Please refer to the "README_first.md" file for detailed information on file structure, variables, units, and data formats.

drought↗

Upper atmospheric probing by resonance fluorescence excited by tunable laser radiation.

Consideration of the application of the measurement of resonance fluorescence radiation excited by tunable laser radiation to the detection of atomic, molecular, and ionic species in the upper atmosphere. The species considered are N2, N2(+), NO, NO(+), O2(+), CO, CO(+), CH, Na, K, and Ca. Calculations of the resonance scattering cross sections, photon returns, and signal-to-noise ratios are given for these species for a range of conditions. Based on a probing altitude of 100 km, the detections of N2, NO, CO, CH, O2, and the trace metals appear feasible with state-of-the-art systems and within the concentration range present in the atmosphere.

Saunders, A. R.↗

Skylab S-193 Radscat microwave measurements of sea surface winds

The S-193 Radscat made extensive measurements of many sea conditions. Measurements were taken in a tropical hurricane (Ava), a tropical storm (Christine), and in portions of extratropical cyclones. Approximately 200 scans of ocean data at 105 kilometer spacings were taken during the first two Skylab missions and another 200 during the final mission when the characteristics of the measurements changed due to damage of the antenna. Backscatter with four transmit/receive polarization combinations and emissions with horizontal and vertical receive polarizations were measured. Other surface parameters investigated for correlation with the measurements included sea temperature, air/sea temperature difference, and gravity-wave spectrum. Methods were developed to correct the microwave measurements for atmospheric effects. The radiometric data were corrected accurately for clear sky and light cloud conditions only. The radiometer measurements were used to recover the surface scattering characteristics for all atmospheric conditions excluding rain. The radiometer measurements also detected the presence of rain which signaled when the scattering measurement should not be used for surface wind estimation. Regression analysis was used to determine empirically the relation between surface parameters and the microwave measurements, after correction for atmospheric effects. Results indicate a relationship approaching square-law at 50 deg between differential scattering coefficient and wind speed with horizontally polarized scattering data showing slightly more sensitivity to wind speed than vertically polarized data.

Moore, R. K.↗

Ray propagation path analysis of acousto-ultrasonic signals in composites

The most important result was the demonstration that acousto-ultrasonic (AU) energy introduced into a laminated graphite/resin propagates by two modes through the structure. The first mode, along the graphite fibers, is the faster. The second mode, through the resin matrix, besides being slower is also more strongly attenuated at the higher frequencies. This demonstration was accomplished by analyzing the time and frequency domain of the composite AU signal and comparing them to the same for a neat resin specimen of the same chemistry and geometry as the composite matrix. Analysis of the fine structure of AU spectra was accomplished by various geometrical strategies. It was shown that the multitude of narrow peaks associated with AU spectra are the effect of the many pulse arrivals in the signal. The shape and distribution of the peaks is mainly determined by the condition of nonnormal reflections of ray paths. A cepstrum analysis was employed which can be useful in detecting characteristic times. Analysis of propagation modes can be accomplished while ignoring the fine structure.

Kautz, Harold E.↗

A comparison of frequency estimation techniques for high-dynamic trajectories

A comparison is presented for four different estimation techniques applied to the problem of continuously estimating the parameters of a sinusoidal Global Positioning System (GPS) signal, observed in the presence of additive noise, under extremely high-dynamic conditions. Frequency estimates are emphasized, although phase and/or frequency rate are also estimated by some of the algorithms. These parameters are related to the velocity, position, and acceleration of the maneuvering transmitter. Estimated performance at low carrier-to-noise ratios and high dynamics is investigated for the purpose of determining the useful operating range of an approximate Maximum Likelihood (ML) estimator, an Extended Kalman Filter (EKF), a Cross-Product Automatic Frequency Control (CPAFC) loop, and a digital phase-locked loop (PPL). Numerical simulations are used to evaluate performance while tracking a common trajectory exhibiting high dynamics.

Vilnrotter, V. A.↗

Prototype FAGE determination of NO2

A low pressure laser-excited-fluorescence technique for the direct determination of atmospheric NO2 has been developed. Using a frequency-doubled Nd-YAG pump laser and a signal collection time of 20 s (10 s each signal and background), a detection limit of 450 pptv is calculated under laboratory conditions. Improved sensitivities will be possible with a higher repetition rate laser and lower fluorescence cell pressures.

George, L. A.↗

Generalized probability model for calculation of interference to the Deep Space Network due to circularly Earth-orbiting satellites

The probability of exceeding interference power levels and the duration of interference at the Deep Space Network (DSN) antenna is calculated parametrically when the state vector of an Earth-orbiting satellite over the DSN station view area is not known. A conditional probability distribution function is derived, transformed, and then convolved with the interference signal uncertainties to yield the probability distribution of interference at any given instant during the orbiter's mission period. The analysis is applicable to orbiting satellites having circular orbits with known altitude and inclination angle.

Ruggier, C. J.↗

A potassium Faraday anomalous dispersion optical filter

The characteristics of a potassium Faraday anomalous dispersion optical filter operating on the blue and near infrared transitions are calculated. The results show that the filter can be designed to provide high transmission, very narrow pass bandwidth, and low equivalent noise bandwidth. The Faraday anomalous dispersion optical filter (FADOF) provides a narrow pass bandwidth (about GHz) optical filter for laser communications, remote sensing, and lidar. The general theoretical model for the FADOF has been established in our previous paper. In this paper, we have identified the optimum operational conditions for a potassium FADOF operating on the blue and infrared transitions. The signal transmission, bandwidth, and equivalent noise bandwidth (ENBW) are also calculated.

Yin, B.↗

Flux-focusing eddy current probe and method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material is presented. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗

Flux-focusing eddy current probe and rotating probe method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Buzz A.↗

Demonstration of Berry Phase in Optical Spectroscopy

In this paper we demonstrate that the observed phase shift of the RF signal and its intensity dependence under extreme low pump and probe laser field conditions are dominated by Berry phase effect in optical spectroscopy with good adiabatic approximation, which provides all features' agreements between the theoretical and the experimental results.

Xia, Hui-Rong↗

Rubidium Ultra-Stable Oscillators at Titan: The Huygens Doppler Wind Experiment

The Doppler Wind Experiment (DWE) is one of six investigations to be performed during the Titan atmospheric descent of the ESA Huygens Probe. The primary scientific objective is to measure the direction and strength of Titan's zonal winds with an accuracy better than 1 m/s. The Probe's wind-induced horizontal motion will be derived from the residual Doppler shift of its S-band radio link to the Cassini Orbiter, corrected for all known orbit and propagation effects, from the beginning of the mission (altitude: approx. 160 km) down to impact on the surface. The DWE Instrumentation consists of Rb-based Ultra-Stable Oscillators used to: (1) generate the transmitted signal from the Probe and (2) extract the frequency of the received signal on the Orbiter. The capabilities of these USOs under the rugged experimental conditions on Titan and some results from the DWE pre-launch test program are described.

Bird, M. K.↗

Eddy Current Method for Fatigue Testing

Flux-focusing electromagnetic sensor using a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. A ferrous shield isolates a high-turn pick-up coil from an excitation coil. Use of the magnetic shield produces a null voltage output across the receiving coil in presence of an unflawed sample. Redistribution of the current flow in the sample caused by the presence of flaws. eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. Maximum sensor output is obtained when positioned symmetrically above the crack. By obtaining position of maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. Accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output resulting in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip enabling the search region to be clearly defined. Under low frequency operation, material thinning due to corrosion causes incomplete shielding of the pick-up coil. Low frequency output voltage of the probe is therefore a direct indicator of thickness of the test sample. Fatigue testing a conductive material is accomplished by applying load to the material, applying current to the sensor, scanning the material with the sensor, monitoring the sensor output signal, adjusting material load based on the sensor output signal of the sensor, and adjusting position of the sensor based on its output signal.

Simpson, John W.↗

Sleep and Rest Requirements: Physiological Considerations

Sleep is a vital physiological need which must be met to insure optimal functioning. A single night of significantly shortened sleep negatively impacts performance, alertness, and mood. Restricted sleep studies have shown that even a relatively small amount of sleep loss over several consecutive days can be additive and result in a cumulative sleep debt with similar detrimental effects. Compounding the problem of sleep loss in the operational environment is the poor correlation between subjective reports of sleepiness and objective measures of physiological sleep need. Some of the factors determining how sleepy an individual is at a given point in time are: (1) individual characteristics (e.g., amount of prior sleep and wakefulness, circadian phase, age), (2) environmental conditions (e.g., noise, temperature, amount of social interaction), and (3) task variables (e.g., signal rate, workload). Although sleep need can be masked with medications, the only way to reduce it is with sleep itself. The timing of the sleep period can affect sleep duration and quality and thus its restorative strength. The data are clear that increasing sleep time results in improved alertness. This paper will briefly review the scientific findings on sleep need, the effects of sleep loss, napping strategies, and the implications of incorporating physiologically sound sleep and rest strategies into the operational aviation environment.

Neri, David F.↗

Human Tissue Stimulator

Neurodyne Corporation Human Tissue Stimulator (HTS) is a totally implantable system used for treatment of chronic pain and involuntary motion disorders by electrical stimulation. It was developed by Pacesetter Systems, Inc. in cooperation with the Applied Physics Laboratory. HTS incorporates a nickel cadmium battery, telemetry and command systems technologies of the same type as those used in NASA's Small Astronomy Satellite-3 in microminiature proportions so that the implantable element is the size of a deck of cards. The stimulator includes a rechargeable battery, an antenna and electronics to receive and process commands and to report on its own condition via telemetry, a wireless process wherein instrument data is converted to electrical signals and sent to a receiver where signals are presented as usable information. The HTS is targeted to nerve centers or to particular areas of the brain to provide relief from intractable pain or arrest involuntary motion. The nickel cadmium battery can be recharged through the skin. The first two HTS units were implanted last year and have been successful. Extensive testing is required before HTS can be made available for general use.

Source record↗

Microelectronic DNA assay for the detection of BRCA1 gene mutations

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).

Validation Studies↗