High Performance Scintillator for Nuclear Physics Research
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Multiplicity counters for neutron assay have been extensively used in materials control and accountability for nonproliferation and nuclear safeguards. Typically, neutron coincidence counters are utilized in these fields. In this work, we present a measurement system that makes use not only of neutron (n) multiplicity counting but also of gamma-ray (g) multiplicity counting and the combined higher-order multiples containing both neutrons and gamma rays. The benefit of this approach is in using both particle types available from the sample, leading to a reduction in measurement times needed when using more measurables. We present measurement results of n, g, nn, ng, gg, nnn, nng, ngg, and ggg multiples emitted by Mixed-Oxide (MOX) samples measured at Idaho National Laboratory (INL). The MOX measurement is compared to initial validation of the detection system done using a 252Cf source. The dual radiation measuring system proposed here uses extra measurables to improve the statistics when compared to a neutron-only system and allows for extended analysis and interpretation of sample parameters. New challenges such as the effect of very high intrinsic gamma-ray sources in the case of MOX samples is discussed. Successful measurements of multiples rates can be performed also when using high-Z shielding.
Not Available
Not Available
Not Available
Not Available
No abstract prepared.
This paper presents the design techniques of a monolithic multichannel front-end readout chip integrated with both high-accuracy TDC and high-resolution ADC for the PET using LYSO(Ce) crystals read out by MCP PMT at both ends. In the front-end readout chain, a regulated cascade (RGC) preamplifier is employed in every channel for amplifying the current signals generated from MCP detector. A gain-adjustment stage, an integrator and a pulse shaper are employed for pulse height analysis which changes the width of the pulses. A discriminator is placed after the preamplifier to generate triggers. These triggers are sent to a sub-nanosecond TDC for measurement and digitizing. The peak values of the shaped pulses are digitized by a multichannel time-based ADC for measurement. Three prototype chips are designed in AMS 0.35 {mu}m CMOS technology. In the front-end readout prototype chip, the dynamic range, the linearity, and the power dissipation are optimized. The input dynamic range from few fC to more than 100 pC can be achieved. The analog output range of the front-end readout circuits is from 1.2 V to 3.2 V. The shaping time is 280 ns and the power dissipation is reduced to less than 15 mW. In the TDC chip based on a DLL array, the RMS jitter and the peak-to-peak jitter of the used DLL are reduced to 7 ps and 21 ps, respectively. The bin size of the TDC has been reduced to 71 ps with a reference clock of 100 MHz. In the multichannel time-based ADC chip, a maximum resolution of 12 bits, a sampling rate of {approx}1 MS/s, and the power dissipation of 3 mW deg. 0.2 mW/channel are achieved. (authors)
We regard the possibility of detecting the antineutrino flux producing by the {sup 40}K placing inside the Earth. Thermal flux of the Earth could be better understood with observing such a flux. Lower and upper limitations on the {sup 40}K antineutrino flux are presented.
Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Direct determination of rare earth location and local environment in NaYP{sub 2}O{sub 7} are presented. Undoped and Ln-doped NaYP{sub 2}O{sub 7} (Ln=Eu, Ce) were produced via PVA-assisted sol–gel method. Lattice parameters were determined from Rietveld refinement, showing monoclinic structure. XAS results suggested Eu{sup 3+} and Ce{sup 3+} are incorporated into NaYP{sub 2}O{sub 7} host in substitution to Y{sup 3+} site, with first coordination shell formed by six oxygen ions. Measurements at Eu edge showed a single peak in R space for Eu–O distribution. In this case, uniform interatomic distances implied to absence of significant disorder. Analysis at Ce edge presented different behavior, with Ce–O distribution characterized by a split peak in R space. Nearest neighborhood was found to be distributed with Ce occupying an off-center position in Y site. Under X-ray excitation, {sup 5}D{sub 0}→{sup 7}F{sub J} emission lines of Eu{sup 3+} were identified for NaYP{sub 2}O{sub 7}:Eu. NaYP{sub 2}O{sub 7}:Ce presented a broad emission formed by 5d→{sup 2}F{sub J} transitions of Ce{sup 3+}, with the superposition attributed to the effect of distorted oxygen octahedra around the dopant ions. - Graphical abstract: EuO{sub 6} and CeO{sub 6} octahedral arrangement relative to Y site in NaYP{sub 2}O{sub 7} host, and XEOL emission of corresponding doped samples. - Highlights: • Lattice parameters of NaYP{sub 2}O{sub 7} undoped sample confirmed monoclinic structure. • Dopants Eu and Ce are incorporated in the trivalent state. • Local order of Eu{sup 3+} and Ce{sup 3+} dopants substituting Y{sup 3+} consist of octahedral symmetry. • Off-center displacement in the case of Ce{sup 3+} position was discussed. • Luminescent properties under X-ray excitation may allow practical applications.