Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Real time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Atmospheric Infrared Sounder Version 7 Near-Real-Time Product and Imagery Released by NASA GES DISC

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of data processing, archive, and distribution services for data from the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002. The GES DISC provides service to both AIRS routine and Near Real-Time (NRT) products. The AIRS NRT products are an important element in the Land, Atmosphere Near real-time Capability for EOS (LANCE). In collaboration with AIRS Project, the GES DISC has just released products from the Version 7 algorithm. The new version algorithm provides significant improvements over the previous version. The most substantial advances are: improved consistency between day and night water vapor; improved total column ozone and temperature; improved infrared-only (IR-only) retrievals, especially in high latitude regions; an improved Stochastic Cloud Clearing Neural Network used as a first guess at the initial value in the iterative retrieval process; and removal of ambiguity in surface classification in the IR-only retrieval algorithm. In addition, the GES DISC produces AIRS NRT imagery. The AIRS NRT imagery are generated by mosaicking and mapping the available AIRS 6-minute retrieval granules to a global projection. The images are constantly refreshed when new granules are produced. The AIRS NRT Viewer and LANCE Worldview provide visualization services to online users for AIRS NRT imagery. The data products used to generate this imagery include atmospheric temperature, humidity, precipitation, cloud, Dust Score, CO, and SO2. In this presentation, we will demonstrate visualization of the AIRS NRT imagery from the new Version 7, and demonstrate some improvements over the previous version. Progress on improving the AIRS NRT imagery, a collaboration project with the AIRS Applications Development Team at NASA Jet Propulsion Laboratory (JPL), will also be presented.

Feng Ding↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

MONITORING SPENT NUCLEAR FUEL REPROCESSING CONDITIONS NON-DESTRUCTIVELY AND IN NEAR-REAL-TIME USING THE MULTI-ISOTOPE PROCESS (MIP) MONITOR

Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, nondestructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory testing is currently under way and significant results are available. Recent experimental results, along with an overview of the method are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-time remote scientific model validation

This paper describes flight results from the use of a CLIPS-based validation facility to compare analyzed data from a space life sciences (SLS) experiment to an investigator's preflight model. The comparison, performed in real-time, either confirms or refutes the model and its predictions. This result then becomes the basis for continuing or modifying the investigator's experiment protocol. Typically, neither the astronaut crew in Spacelab nor the ground-based investigator team are able to react to their experiment data in real time. This facility, part of a larger science advisor system called Principal Investigator in a Box, was flown on the space shuttle in October, 1993. The software system aided the conduct of a human vestibular physiology experiment and was able to outperform humans in the tasks of data integrity assurance, data analysis, and scientific model validation. Of twelve preflight hypotheses associated with investigator's model, seven were confirmed and five were rejected or compromised.

Frainier, Richard↗

Real-Time X-Ray Microscopy of Al-Cu Eutectic Solidification

Recent improvements in the resolution of the X-ray Transmission Microscope (XTM) for Solidification Studies provide microstructure feature detectability down to 5 micrometers during solidification. This presentation will show the recent results from observations made in real-time of the solid-liquid interfacial morphologies of the Al-CuAI2 eutectic alloy. Lamellar dimensions and spacings, transitions of morphology caused by growth rate changes, and eutectic grain structures are open to measurements. A unique vantage point viewing the face of the interface isotherm is possible for the first time with the XTM due to its infinite depth of field. A video of the solid-liquid interfaces seen in-situ and in real-time will be shown.

Kaukler, William F.↗

Development of a Real-Time Neutron Noise Analysis System for Fuel Debris Removal at Fukushima Daiichi

The decommissioning of Units 1, 2, and 3 at Fukushima Daiichi presents unique challenges, particularly in mitigating the risk of re-criticality during fuel debris removal. Disturbing previously stable debris configurations has the potential to cause changes in the multiplication of the system, necessitating real-time monitoring to ensure operational safety. Current neutron detection systems, primarily passive, are not optimized for continuous real-time analysis and are limited in their ability to detect rapid changes in system reactivity.

Neutron Detection Systems↗

Method for Real-Time Salt Aerosol Concentration and Size Measurements for Molten Salt Reactor Safety Assessments

Licensing a new nuclear reactor involves evaluating credible accident scenarios by developing models that simulate accident progression to predict possible outcomes and their impact on safety. The formation of radionuclide-bearing aerosols in the respirable size range can significantly affect dose consequence and threaten human health and is therefore a focus of nuclear reactor safety assessments. Recent reviews of the literature identified a lack of existing experimental data describing the mechanisms of formation and properties (size, concentration, and composition) of radionuclide-bearing aerosols that may be produced from molten salt reactor (MSR) facilities during postulated accident scenarios. Experiments on aerosol formation from molten salt systems are a high priority need that will support MSR licensing by indicating the radiological consequences of aerosol formation and providing the data required for model development and validation. The evolving conditions that occur during a MSR accident, such as a spill of molten fuel salt, may affect aerosol formation mechanisms and aerosol properties over time. There is a need to conduct experiments that simulate credible MSR accidents in a laboratory to generate aerosols with realistic characteristics and behaviors and a need to measure these aerosols in real time under accident-relevant conditions. This report describes the development of a method that can be used to quantify the size and concentration of salt aerosol particles that form from molten salt systems in real time. This method will be employed in future integral effects tests that are conducted at an engineering scale to simulate realistic MSR accidents and in future separate effects tests that will provide mechanistic insight into aerosol formation and properties to support process model development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Image processing with cellular nonlinear networks implemented on field-programmable gate arrays for real-time applications in nuclear fusion

In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested in an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A real-time simulation evaluation of an advanced detection. Isolation and accommodation algorithm for sensor failures in turbine engines

An advanced sensor failure detection, isolation, and accommodation (ADIA) algorithm has been developed for use with an aircraft turbofan engine control system. In a previous paper the authors described the ADIA algorithm and its real-time implementation. Subsequent improvements made to the algorithm and implementation are discussed, and the results of an evaluation presented. The evaluation used a real-time, hybrid computer simulation of an F100 turbofan engine.

Merrill, W. C.↗

A real-time simulation evaluation of an advanced detection, isolation and accommodation algorithm for sensor failures in turbine engines

An advanced sensor failure detection, isolation, and accommodation (ADIA) algorithm has been developed for use with an aircraft turbofan engine control system. In a previous paper the authors described the ADIA algorithm and its real-time implementation. Subsequent improvements made to the algorithm and implementation are discussed, and the results of an evaluation presented. The evaluation used a real-time, hybrid computer simulation of an F100 turbofan engine.

Merrill, W. C.↗

Real time quantum dynamics preaveraged over imaginary time path integral: A formal basis for both Centroid Molecular Dynamics and Ring Polymer Molecular Dynamics

An exact real time quantum dynamics preaveraged over imaginary time path integral is formulated for general condensed phase equilibrium ensemble. This formulation results in the well-known centroid dynamics approach upon filtering of centroid constraint, and provides a rigorous framework to understand and analyze a related quantum dynamics approximation method called ring polymer molecular dynamics. The formulation also serves as the basis for developing new kinds of quantum dynamics that utilize the cyclic nature of the imaginary time path integral.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral decontamination of a real-time helicopter simulation

Nonlinear mathematical models of a rotor system, referred to as rotating blade-element models, produce steady-state, high-frequency harmonics of significant magnitude. In a discrete simulation model, certain of these harmonics may be incompatible with realistic real-time computational constraints because of their aliasing into the operational low-pass region. However, the energy is an aliased harmonic may be suppressed by increasing the computation rate of an isolated, causal nonlinearity and using an appropriate filter. This decontamination technique is applied to Sikorsky's real-time model of the Black Hawk helicopter, as supplied to NASA for handling-qualities investigations.

Mcfarland, R. E.↗

Study of the impact of pre- and real-time deposition of lithium on plasma performance on NSTX

The efficiency of two lithium (Li) injection methods used on the National Spherical Torus Experiment (NSTX) are compared in terms of the amount of Li used to produce equivalent plasma performance improvements, namely Li evaporation over the divertor plates, prior to the initiation of the discharge, and real-time Li injection directly into the plasma scrape-off layer during the discharge. The measurements show that the real-time method can affect the energy confinement and edge stability of NSTX plasmas in a more efficient way than the Li evaporation method as it requires only a fraction of the amount of Li used by the evaporation method to produce similar improvements.

Lithium↗

Single Stage Rocket Technology's real time data system

The Single Stage Rocket Technology (SSRT) Delta Clipper Experimental (DC-X) Program is a United States Air Force Ballistic Missile Defense Organization (BMDO) rapid prototyping initiative that is currently demonstrating technology readiness for reusable suborbital rockets. The McDonnell Douglas DC-X rocket performed technology demonstrations at the U.S. Army White Sands Missile Range in New Mexico from April-October in 1993. The DC-X Flight Operations Control Center (FOCC) contains the ground control system that is used to monitor and control the DC-X vehicle and its Ground Support Systems (GSS). The FOCC is operated by a flight crew of three operators. Two operators manage the DC-X Flight Systems and one operator is the Ground Systems Manager. A group from McDonnell Douglas Aerospace at KSC developed the DC-X ground control system for the FOCC. This system is known as the Real Time Data System (RTDS). The RTDS is a distributed real time control and monitoring system that utilizes the latest available commercial off-the-shelf computer technology. The RTDS contains front end interfaces for the DC-X RF uplink/downlink and fiber optic interfaces to the GSS equipment. This paper describes the RTDS architecture and FOCC layout. The DC-X applications and ground operations are covered.

Voglewede, Steven D.↗

Non-intrusive, high-resolution, real-time, two-dimensional imaging of multiphase materials using acoustic array sensors

Two parallel multi-element ultrasonic acoustic arrays combined with sets of focal laws for acoustic signal generation and a classical tomographic inversion algorithm are used to generate real-time two-dimensional micro seismic acoustic images of multiphase materials. Proof of concept and calibration measurements were performed for single phase and two phase liquids, uniform polyvinyl chloride (PVC) plates, and aluminum cylinders imbedded in PVC plates. Measurement artefacts, arising from the limited range of viewing angles, and the compromise between data acquisition rate and image quality are discussed. The angle range of scanning and the image resolution were varied, and the effects on the quality of the reproduction of the speed of sound profiles of model solids and liquids with known geometries and compositions were analysed in detail. The best image quality results were obtained for a scanning angle range of [−35°, 35°] at a step size of 2.5° post processed to generate images on a 40 μm square grid. The data acquisition time for high quality images with a 30 mm × 40 mm view field is 10 min. Representation of two-phase solids with large differences in speed of sound between phases and where one phase is dispersed in the form of macroscopic objects (greater than 1 mm in diameter) proved to be the most difficult to image accurately. Liquid-liquid and liquid-vapor phase boundaries, in micro porous solids by contrast, were more readily defined. Displacement of air by water and water by heptane in natural porous limestone provides illustrative kinetic examples. Measurement results with these realistic cases demonstrate the feasibility of the technique to monitor in real time and on the micrometer length scale local composition and flow of organic liquids in inorganic porous media, one of many envisioned engineering applications. Improvement of data acquisition rate is an area for future collaborative study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-18A-07: Towards 6-Degree-Of-Freedom Real-Time Motion Management in Cancer Radiotherapy

Purpose: Lung tumor motion has been identified as a major issue that deteriorates treatment efficacy for radiotherapy, especially for SBRT. As tighter PTV margins are applied due to translational compensation, tumor rotation will become the dominant factor limiting tumor targeting accuracy. This is the world-first study quantifies lung tumor rotation by utilizing kV images with fiducial markers and a step towards 6-degree-of-freedom real-time cancer radiotherapy. Methods: Three or four gold coils were implanted as tumor surrogates in 3 lung cancer patients. 50 fractions of 8- minute, 10 Hz 4D CBCT projections were acquired for the patients immediately prior or after radiotherapy. The fiducial marker positions are segmented, reconstructed and used to determine tumour rotation by the iterative closest point algorithm. Different data acceptance and filtering methods were applied to accept data or smooth the marker trajectory. Results: The average rotation angles around the left/ right (LR), superior/inferior (SI), anterior/posterior (AP) rotations were found to be 0.8±4.2, -0.8±4.5 and 1.7±3.1 degrees respectively. For 28% of the treatment time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotational motion was detected in 2 of the 3 lung patients. This can be explained by the patient developed atelectasis during the treatment period. Interestingly, no heart beating component of rotation was observed in the power spectrum. Different rotational types were observed within the patient cohort with large variations in the magnitude of the rotation between patients. Conclusions: For the first time, continuous tumor rotation has been measured for lung patients with gold fiducial markers. Tumors were found to undergo rotations of more than 5° for almost a third of the total treatment time. The study also demonstrated the feasibility of using continuously kV images for real-time lung tumour motion adaptive radiotherapy which can potentially reduce treatment margins and side effects. The authors acknowledge the financial support of an NHMRC Australia Fellowship.

60 APPLIED LIFE SCIENCES↗

C3PU:Real-Time Predictive Charge Control Software for Battery Management Systems (Code for Charge Control and Predictive Unit) [SWR-21-48]

C3PU sets up a model predictive control formulation for the optimal charging control of battery packs and can be deployed for real-time operation on an embedded microprocessor. C3PU uses electrochemical and thermal models of battery packs to predict the charging trajectories of the battery pack over a time horizon under different operating conditions. It then selects the optimal charging trajectory such that a pre-defined objective is minimized, which in the present state of the code is to minimize the charging duration of the battery pack. The optimal charging trajectory is obtained by solving an underlying mathematical problem. However, C3PU is flexible to incorporate other charging objectives. The underlying battery models can be swapped as well, as long as they follow certain mathematical properties. Mathematically, optimal control problems (in this case, optimally controlling the charging current of the battery pack) are computationally expensive. C3PU implements advanced numerical techniques, namely pseudo-spectral optimization, to reduce the computational burden of the underlying problem to solve. This allows for the problem to be solved in real-time in an embedded system. Once the optimal charging trajectory is computed over a time horizon, C3PU can package such data and send it out via appropriate communication protocols.

Mishra, Partha↗

In vivo real-time dosimetric verification in high dose rate prostate brachytherapy

Purpose: To evaluate the performance of a diode array in the routine verification of planned dose to points inside the rectum from prostate high dose rate (HDR) brachytherapy using a real-time planning system. Methods: A dosimetric study involving 28 patients was undertaken where measured doses received during treatment were compared to those calculated by the treatment planning system (TPS). After the ultrasound imaging required for treatment planning had been recorded, the ultrasound probe was replaced with a geometric replica that contained an 8 mm diameter cylindrical cavity in which a PTW diode array type 9112 was placed. The replica probe was then positioned inside the rectum with the individual diode positions determined using fluoroscopy. Dose was then recorded during the patients' treatment and compared to associated coordinates in the planning system. Results: Factors influencing diode response and experimental uncertainty were initially investigated to estimate the overall uncertainty involved in dose measurements, which was determined to be {+-}10%. Data was acquired for 28 patients' first fractions, 11 patients' second fractions, and 13 patients' third fractions with collection dependent upon circumstances. Deviations between the diode measurements and predicted values ranged from -42% to +35% with 71% of measurements experiencing less than a 10% deviation from the predicted values. If the {+-}10% measurement uncertainty was combined with a tolerated dose discrepancy of {+-}10% then over 95% of the diode results exhibited agreement with the calculated data to within {+-}20%. It must also be noted that when large dose discrepancies were apparent they did not necessarily occur for all five diodes in the one measurement. Conclusions: This technique provided a method that could be utilized to detect gross errors in dose delivery of a real-time prostate HDR plan. Limitations in the detection system used must be well understood if meaningful results are to be achieved.

61 RADIATION PROTECTION AND DOSIMETRY↗