Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Portable, Low-Cost, Column Carbon Dioxide and Methane Measurements for Validating Satellite Observations in Remote Locations

We present a low-cost (~$10K per instrument), portable solution to ground-based validation of satellite observations for difficult to reach locations with precisions of 1 ppm XCO2 and 10 ppb XCH4 for hourly data products. While Total Carbon Column Observing Network (TCCON) is the gold-standard for ground validation, there are locations where a ground column validation data point would be useful but conditions are not conducive to a permanent station. Examples include wetlands, thawing permafrost, the tropics, the Amazon, sub-Saharan Africa, as well as locations without a power grid or with geopolitical conflict. In addition, the low-cost and portability mean a geographical region can be studied in depth with multiple instruments. This passive, sun-pointing instrument is a miniaturized, laser heterodyne radiometer (mini-LHR) that has been under development by our team since 2009. It can be operated either in tandem with AERONET (a global network of 500 instruments that measure aerosol optical depth), or as a stand-alone instrument with a low-cost (~$3K), light-weight sun tracker. One of the main benefits of the mini-LHR is that it can quickly reach remote locations and provide a validation measurement even if there is limited or no infrastructure at the site. The instrument weighs ~10 lbs, fits into a backpack, and is powered by two folding solar panels and a battery pack. In clear conditions, the instrument can be set-up in under an hour. Portability means that mini-LHRs can be easily moved for side-by-side comparisons with other mini-LHRs and with TCCON which simplifies assessing instrument bias as well as accuracy. Like TCCON, the mini-LHR points directly at the sun with a narrow field-of-view and is its insensitivity to cloud and aerosol scattering that is common to nadir-pointing passive satellite approaches. Here we present a collection of sample data sets to demonstrate performance from locations that vary in climate, altitude, solar zenith angle, hours of sun per day, etc., as well as data from side-by-side TCCON comparisons. Retrievals of CO2 and CH4 were completed using the NASA/Goddard's Planetary Spectrum Generator (PSG) that incorporates meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set.

Wilson, Emily W.↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗

Interfractional variation in bladder volume and its impact on cervical cancer radiotherapy: Clinical significance of portable bladder scanner

Purpose: A constant bladder volume (BV) is essential to direct the radiotherapy (RT) of pelvic tumors with precision. The purpose of this study was to investigate changes in BV and their impact on cervical cancer RT and to assess the clinical significance of a portable bladder scanner (BS) in achieving a constant BV. Methods: A standard bladder phantom (133 ml) and measurements of actual urine volume were both used as benchmarks to evaluate the accuracy of the BS. Comparisons of BS with computed tomography (CT), cone-beam CT (CBCT), and an ultrasound diagnostic device (iU22) were made. Twenty-two consecutive patients with cervical cancer treated with external beam radical RT were divided into an experimental group (13 patients) and a control group (9 patients). In the experimental group, the BV was measured multiple times by BS pre-RT until it was consistent with that found by planning CT. Then a CBCT was performed. The BV was measured again immediately post-RT, after which the patient’s urine was collected and recorded. In the control group, CBCT only was performed pre-RT. Interfractional changes in BV and their impact on cervical cancer RT were investigated in both groups. The time of bladder filling was also recorded and analyzed. Results: In measuring the volume of the standard bladder phantom, the BS deviated by 1.4% in accuracy. The difference between the measurements of the BS and the iU22 had no statistical significance (linear correlation coefficient 0.96, P < 0.05). The BV measured by the BS was strongly correlated with the actual urine volume (R = 0.95, P < 0.05), planning CT (R = 0.95, P < 0.05), or CBCT (R = 0.91, P < 0.05). Compared with the BV at the time of CT, its value changed by −36.1% [1 SD (standard deviation) 42.3%; range, −79.1%–29.4%] in the control group, and 5.2% (1 SD 21.5%; range, −13.3%–22.1%) in the experimental group during treatment. The change in BV affected the target position in the superior–inferior (SI) direction but had little or no effect in the anterior–posterior and right–left directions. Based on the collected data, the target displacement in the SI direction was reduced from 2.0 to 0.4 mm, while the CTV-to-PTV (CTV: clinical target volume; PTV: planning target volume) margin in the SI direction was reduced from 11.1 to 6.4 mm. The BV increased by 3.7 ± 1.0 ml/min (range, 1.7–4.7 ml/min), which depended on the amount of water ingested by the patient (R = 0.96, P < 0.05). No correlation was found between the rate of urinary inflow and the patient’s body mass. The authors were able to reduce the workload of measuring by using individual patient information including the patient’s age, the water-drinking amount, time at which water-drinking began, and patient’s diet. Conclusions: Changes in the BV have an influence on the RT of cervical cancer. A consistent and reproducible BV is acquired by using a portable BS, whereby the target displacement and CTV-to-PTV margin can be both reduced in the SI direction.

60 APPLIED LIFE SCIENCES↗

Dynamic Isotope Surface Power Systems

The Dynamic Isotope Power Systems (DIPS) demonstration program, sponsored by the U.S. Department of Energy (DOE) with support funding from the National Aeronautics and Space Administration (NASA), is currently focused on the development of a standardized 2.5 kWe portable generator for multiple applications on the lunar or Martian surface. A variety of potential remote and mobile applications has been identified by NASA including surface rovers for both short and extended duration missions, remote power to science packages, and backup to central base power. Recent work focused on refining the 2.5 kWe design including assessing compatibility with the Martian environment to assure the design is suitable while imposing only a minor mass penalty on lunar operations. Additional work included a study performed to compare the DIPS with regenerative fuel cell systems for lunar mobile and remote power systems. Power requirements were reviewed and a modular system chosen for the comparison. Finally, a plan and cycle schematic were generated for an early demonstration of a prototypic isotope power Brayton system using the Antarctic as the test bed.

Hunt, Maribeth E.↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

The force on the flex: Global parallelism and portability

A parallel programming methodology, called the force, supports the construction of programs to be executed in parallel by an unspecified, but potentially large, number of processes. The methodology was originally developed on a pipelined, shared memory multiprocessor, the Denelcor HEP, and embodies the primitive operations of the force in a set of macros which expand into multiprocessor Fortran code. A small set of primitives is sufficient to write large parallel programs, and the system has been used to produce 10,000 line programs in computational fluid dynamics. The level of complexity of the force primitives is intermediate. It is high enough to mask detailed architectural differences between multiprocessors but low enough to give the user control over performance. The system is being ported to a medium scale multiprocessor, the Flex/32, which is a 20 processor system with a mixture of shared and local memory. Memory organization and the type of processor synchronization supported by the hardware on the two machines lead to some differences in efficient implementations of the force primitives, but the user interface remains the same. An initial implementation was done by retargeting the macros to Flexible Computer Corporation's ConCurrent C language. Subsequently, the macros were caused to directly produce the system calls which form the basis for ConCurrent C. The implementation of the Fortran based system is in step with Flexible Computer Corporations's implementation of a Fortran system in the parallel environment.

Jordan, H. F.↗

Direct recycling of spent nickel-rich cathodes in reciprocal ternary molten salts

Lithium-ion batteries (LIBs) have revolutionized portable electronics and electric vehicles (EVs), but the growing accumulation of end-of-life (EOL) batteries poses environmental challenges. Recycling high-value cathodes from EOL LIBs can minimize waste and reduce the need for mining critical minerals. Here, this study focuses on the direct recycling of Ni-rich cathodes, particularly lithium-manganese-cobalt-oxide (NMC) 622 in a “reciprocal ternary molten salts (RTMS)" system. The ionothermal relithiation in the RTMS system successfully restores the layered structure, lithium content, and electrochemical performance of the NMC 622 cathode, comparable to the pristine material. The cost analysis reveals that cathode regeneration through ionothermal relithiation is more economical than virgin production or conventional recycling methods.

25 ENERGY STORAGE↗

In-field alpha spectrometry system for uranium enrichment verification of uranium hexafluoride

A portable In-Field Alpha Spectrometry (IFAS) system was developed to support on-site uranium enrichment determination for samples taken at facilities working with gaseous UF 6 . It consists of a modified commercial alpha spectrometer, a vacuum pump, a laptop computer, and associated connectors and cables. The IFAS uses specially designed Single-Use Destructive Assay (SUDA) samplers to capture gaseous UF 6 and convert and store it as UO 2 F 2 in a thin-film zeolite. To examine the quantitative performance of the IFAS system a large number of replicate SUDA samples was acquired for natural uranium (NU, 0.72 wt%, 23 samples), low enriched uranium 1 (LEU1, 2.33 wt% 235 U, 10 samples), and low enriched uranium 2 (LEU2, 4.62 wt% 235 U, 10 samples). The standard deviation (SD) values for uranium enrichment determination with the IFAS for NU, LEU1, and LEU2, in 20-hour assays, were 0.037 wt% 235 U, 0.063 wt% 235 U, and 0.072 wt% 235 U, respectively. In addition, a separate analysis suggests that comparable SD values can be achieved in less time, approximately 8-10 hours. For context, these SD values are well below the International Atomic Energy Agency’s International Target Values for the determination of uranium enrichment in non-destructive assay measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Inspection for Friction Stir Welds for Rocket Fuel Tanks

During development of the Ares I weld processes nondestructive and destructive testing were used to identify and characterize defects that occurred. These defects were named and character noted. This catalogue of defects and characteristics was then used to develop inspection methods for Self Reacting Friction Stir Welds (SR ]FSW) and Conventional Friction Stir Welds (C ]FSW). Dye penetrant, eddy current, x ]radiography, single element ultrasonic, and phased array ultrasonic (PAUT) inspection procedures were developed to target the expected defects. Once the method procedure was developed a comparison was performed to allow for selection of the best inspection method. Tests of the effectiveness of the inspection were performed on purposely fabricated flawed specimens and electrodischarge machined notches. The initial test results prompted a revisit of the PAUT procedure and a redesign of the inspection. Subsequent testing showed that a multi ]angle PAUT inspection resulted in better detection capability. A discussion of the most effective orientations of the PAUT transducer will be presented. Also, the implementation of the inspection on production hardware will be presented. In some cases the weld tool is used as the transducer manipulator and in some cases a portable scanner is used

Russell, Samuel S.↗

ProperCAD: A portable object-oriented parallel environment for VLSI CAD

Most parallel algorithms for VLSI CAD proposed to date have one important drawback: they work efficiently only on machines that they were designed for. As a result, algorithms designed to date are dependent on the architecture for which they are developed and do not port easily to other parallel architectures. A new project under way to address this problem is described. A Portable object-oriented parallel environment for CAD algorithms (ProperCAD) is being developed. The objectives of this research are (1) to develop new parallel algorithms that run in a portable object-oriented environment (CAD algorithms using a general purpose platform for portable parallel programming called CARM is being developed and a C++ environment that is truly object-oriented and specialized for CAD applications is also being developed); and (2) to design the parallel algorithms around a good sequential algorithm with a well-defined parallel-sequential interface (permitting the parallel algorithm to benefit from future developments in sequential algorithms). One CAD application that has been implemented as part of the ProperCAD project, flat VLSI circuit extraction, is described. The algorithm, its implementation, and its performance on a range of parallel machines are discussed in detail. It currently runs on an Encore Multimax, a Sequent Symmetry, Intel iPSC/2 and i860 hypercubes, a NCUBE 2 hypercube, and a network of Sun Sparc workstations. Performance data for other applications that were developed are provided: namely test pattern generation for sequential circuits, parallel logic synthesis, and standard cell placement.

Ramkumar, Balkrishna↗

Intelligent tutoring using HyperCLIPS

HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.

Hill, Randall W., Jr.↗

Portable Medical System

Portable Medical Status and Treatment System (PMSTS) is designed for use in remote areas where considerable time may elapse before a patient can be transported to a hospital. First units were delivered to the Department of Transportation last year and tested in two types of medical emergency environments: one in a rural Pennsylvania community and another aboard a U.S. Coast Guard rescue helicopter operating along Florida's Gulf Coast. The system has the capability to transmit vital signs to a distantly located physician, who can perform diagnosis and relay treatment instructions to the attendant at the scene. The battery powered PMSTS includes a vital signs monitor and a defibrillator. Narco has also developed a companion system, called Porta-Fib III designed for use in a hospital environment with modifications accordingly. Both systems are offshoots of an earlier NASA project known as the Physician's Black Bag developed by Telecare, Inc., a company now acquired by NARCO.

Source record↗

NASA Tech Briefs, December 2009

Topics include: A Deep Space Network Portable Radio Science Receiver; Detecting Phase Boundaries in Hard-Sphere Suspensions; Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery; Very-Long-Distance Remote Hearing and Vibrometry; Using GPS to Detect Imminent Tsunamis; Stream Flow Prediction by Remote Sensing and Genetic Programming; Pilotless Frame Synchronization Using LDPC Code Constraints; Radiometer on a Chip; Measuring Luminescence Lifetime With Help of a DSP; Modulation Based on Probability Density Functions; Ku Telemetry Modulator for Suborbital Vehicles; Photonic Links for High-Performance Arraying of Antennas; Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration; Hardware-Efficient Monitoring of I/O Signals; Video System for Viewing From a Remote or Windowless Cockpit; Spacesuit Data Display and Management System; IEEE 1394 Hub With Fault Containment; Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph; Waveguide Transition for Submillimeter-Wave MMICs; Magnetic-Field-Tunable Superconducting Rectifier; Bonded Invar Clip Removal Using Foil Heaters; Fabricating Radial Groove Gratings Using Projection Photolithography; Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates; Method for Measuring the Volume-Scattering Function of Water; Method of Heating a Foam-Based Catalyst Bed; Small Deflection Energy Analyzer for Energy and Angular Distributions; Polymeric Bladder for Storing Liquid Oxygen; Pyrotechnic Simulator/Stray-Voltage Detector; Inventions Utilizing Microfluidics and Colloidal Particles; RuO2 Thermometer for Ultra-Low Temperatures; Ultra-Compact, High-Resolution LADAR System for 3D Imaging; Dual-Channel Multi-Purpose Telescope; Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting; CMOS Camera Array With Onboard Memory; Quickly Approximating the Distance Between Two Objects; Processing Images of Craters for Spacecraft Navigation; Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System; Rover Slip Validation and Prediction Algorithm; Safety and Quality Training Simulator; Supply-Chain Optimization Template; Algorithm for Computing Particle/Surface Interactions; Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images; and Thermal Transport Model for Heat Sink Design.

Source record↗

Scientific Benefits of Space Science Models Archiving at Community Coordinated Modeling Center

The Community Coordinated Modeling Center (CCMC) hosts a set of state-of-the-art space science models ranging from the solar atmosphere to the Earth's upper atmosphere. CCMC provides a web-based Run-on-Request system, by which the interested scientist can request simulations for a broad range of space science problems. To allow the models to be driven by data relevant to particular events CCMC developed a tool that automatically downloads data from data archives and transform them to required formats. CCMC also provides a tailored web-based visualization interface for the model output, as well as the capability to download the simulation output in portable format. CCMC offers a variety of visualization and output analysis tools to aid scientists in interpretation of simulation results. During eight years since the Run-on-request system became available the CCMC archived the results of almost 3000 runs that are covering significant space weather events and time intervals of interest identified by the community. The simulation results archived at CCMC also include a library of general purpose runs with modeled conditions that are used for education and research. Archiving results of simulations performed in support of several Modeling Challenges helps to evaluate the progress in space weather modeling over time. We will highlight the scientific benefits of CCMC space science model archive and discuss plans for further development of advanced methods to interact with simulation results.

Kuznetsova, Maria M.↗

Development of a prototype regenerable carbon dioxide absorber for portable life support systems

The design and development of a prototype carbon dioxide absorber using potassium carbonate (K2CO3) is described. Absorbers are constructed of thin, porous sheets of supported K2CO3 that are spirally wound to form a cylindrical reactor. Axial gas passages are formed between the porous sheets by corrugated screen material. Carbon dioxide and water in an enclosed life support system atmosphere react with potassium carbonate to form potassium bicarbonate. The potassium carbonate is regenerated by heating the potassium bicarbonate to 150 C at ambient pressure. The extravehicular mission design conditions are for one man for 8 h. Results are shown for a subunit test module investigating the effects of heat release, length-to-diameter ratio, and active cooling upon performance. The most important effect upon carbon dioxide removal is the temperature of the potassium carbonate.

Onischak, M.↗

TaskWorks v1.0

TaskWorks is a portable, high-level, task engine designed for HPC workloads. Applications can create tasks and define dependencies between them with the task engine. Once the task is defined and submitted to TaskWorks, the TaskWorks engine will execute it according to the specified dependencies, without additional input from the application. TaskWorks has an integrated event manager monitors files, sockets, timers, and MPI operations, and these events can be used as task dependencies. TaskWorks is compatible with MPI and is designed to work efficiently with HPC applications that perform.

Koziol, Quincey↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Enabling Exploration of Deep Space: High Density Storage of Antimatter

Portable electromagnetic antiproton traps are now in a state of realization. This allows facilities like NASA Marshall Space Flight Center to conduct antimatter research remote to production sites. MSFC is currently developing a trap to store 10(exp 12) antiprotons for a twenty-day half-life period to be used in future experiments including antimatter plasma guns, antimatter-initiated microfusion, and the synthesis of antihydrogen for space propulsion applications. In 1998, issues including design, safety and transportation were considered for the MSFC High Performance Antimatter Trap (HiPAT). Radial diffusion and annihilation losses of antiprotons prompted the use of a 4 Tesla superconducting magnet and a 20 KV electrostatic potential at 10(exp -12) Torr pressure. Cryogenic fluids used to maintain a trap temperature of 4K were sized accordingly to provide twenty days of stand-alone storage time (half-life). Procurement of the superconducting magnet with associated cryostat has been completed. The inner, ultra-high vacuum system with electrode structures has been fabricated, tested and delivered to MSFC along with the magnet and cryostat. Assembly of these systems is currently in progress. Testing under high vacuum conditions, using electrons and hydrogen ions will follow in the months ahead.

Smith, Gerald A.↗