Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring Systems

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

Bentley, Nicole↗

Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring System

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

On the correlation between plastic strain and misorientation in polycrystalline body-centered-cubic microstructures with an emphasis on the grain size, loading history, and crystallographic orientation

In this work, the correlation between plastic strain and crystallographic misorientation, grain size, grain orientation, distance from grain boundary, and loading history were investigated experimentally and numerically for body-centered-cubic (BCC) polycrystalline microstructures based on a misorientation deviation (MD) approach. Nine monotonic tensile experiments were performed on two BCC titanium alloys inside a scanning electron microscope (SEM). The influence of reference orientation was explored both at the grain scale and at the mesoscale using electron backscattered diffraction (EBSD). The correlation between global plastic strain and the MD was quantified. The tendency for orientation change was quantified as a function of plastic strain and grain orientation for three crystallographic orientations (i.e., [100], [110], and [111]) with respect to tensile direction. The subpopulation of small grains exhibited a lower level of misorientation dispersion compared with larger grains, and this discrepancy became more pronounced at higher strains. An empirical equation was proposed to estimate the level of misorientation dispersion for individual grains as a function of grain size and global plastic strain level. Two interrupted in-situ SEM experiments were performed, and this resulted in a significantly increased misorientation compared with uninterrupted tests performed to similar plastic strain levels.

36 MATERIALS SCIENCE↗

Development of a 6LiF/ZnS-based Neutron Multiplicity Counter

Abstract–Neutron multiplicity counters are used in safeguards to provide rapid assay of samples which contain an unknown amount of plutonium in a potentially unknown configuration. A project at PNNL is using regular and nickel-quenched 6LiF/ZnS neutron-scintillator sheets and wavelength shifting plastic for light pipes in place of 3He. A combination of laboratory and modeling work predicts a LiF/ZnS-based system to be able to match or exceed the performance of the best 3He-based systems available. Also, the Ni-quenched material is expected to allow for improved neutron/gamma-ray discrimination at twice the event rate relative to the non-Ni-quenched LiF/ZnS. A new system based on the LiF/ZnS material is under construction and components are being used to optimize the detection efficiency and neutron/gamma-ray discrimination properties. Components of the new system are partially constructed and undergoing performance testing utilizing high-speed digitizers with field programmable gate arrays to perform the neutron/gamma-ray discrimination. The expected performance of the full-scale system is expected to be nearly the same as for 3He-based systems and is due for completion in 2016.

Stave, Sean C.↗

Multi-Purpose, Application-Centric, Scalable I/O Proxy Application

MACSio is a Multi-purpose, Application-Centric, Scalable I/O proxy application. It is designed to support a number of goals with respect to parallel I/O performance testing and benchmarking including the ability to test and compare various I/O libraries and I/O paradigms, to predict scalable performance of real applications and to help identify where improvements in I/O performance can be made within the HPC I/O software stack.

Miller, M.C.↗

2012 Groundwater Monitoring and Inspection Report Gnome-Coach, New Mexico, Site

Gnome-Coach was the site of a 3-kiloton underground nuclear test conducted in 1961. Surface and subsurface contamination resulted from the underground nuclear testing, post-test drilling, and a groundwater tracer test performed at the site. Surface reclamation and remediation began after the underground testing. A Completion Report was prepared, and the State of New Mexico is currently proceeding with a conditional certificate of completion for the surface. Subsurface corrective action activities began in 1972 and have generally consisted of annual sampling and monitoring of wells near the site. In 2008, the annual site inspections were refined to include hydraulic head monitoring and collection of samples from groundwater monitoring wells onsite using the low-flow sampling method. These activities were conducted during this monitoring period on January 18, 2012. Analytical results from this sampling event indicate that concentrations of tritium, strontium-90, and cesium-137 were generally consistent with concentrations from historical sampling events. The exceptions are the decreases in concentrations of strontium-90 in samples from wells USGS-4 and USGS-8, which were more than 2.5 times lower than last year's results. Well USGS-1 provides water for livestock belonging to area ranchers, and a dedicated submersible pump cycles on and off to maintain a constant volume in a nearby water tank. Water levels in wells USGS-4 and USGS-8 respond to the on/off cycling of the water supply pumping from well USGS-1. Well LRL-7 was not sampled in January, and water levels were still increasing when the transducer data were downloaded in September. A seismic reflection survey was also conducted this year. The survey acquired approximately 13.9 miles of seismic reflection data along 7 profiles on and near the site. These activities were conducted from February 23 through March 10, 2012. The site roads, monitoring well heads, and the monument at surface ground zero were in good condition at the time of the site inspection. However, it was reported in September 2012 that the USGS-1 well head had been damaged by a water truck in April 2012.

54 ENVIRONMENTAL SCIENCES↗

ION Advanced Solvent CO 2 Capture Pilot Project

This final report to DOE/NETL presents all the work and tests performed during ION Engineering’s (ION) carbon dioxide (CO 2 ) capture pilot test campaign: “ION Advanced Solvent CO 2 Capture Project”. This project is comprised of three budget periods (BP): BP1 – Design of a 0.6 MWe system, BP2 – 0.5 MWe National Carbon Capture Center (NCCC) Testing Campaign, and BP3 – 12 MWe Technology Center at Mongstad (TCM) Testing Campaign. The program began in October 2013 and continued until December 2017. The campaign at NCCC, which took place from June to August of 2015, resulted in 1,116 operational hours where ~350 tonnes of CO 2 were captured from the 0.5 MWe coal-fired flue gas slipstream. The follow-up campaign at TCM took place from Oct 2016 to April 2017, where 2,775 hours of operation resulted in the capture of 14,820 tonnes of CO 2 , which is a cumulative of capturing CO 2 from the natural gas-fired Combined Heat and Power (CHP) plant, and a residue fluid catalytic cracker gas (RFCC) from Statoil at Mongstad. ION has conducted a thoughtful, comprehensive, and successful program in close collaboration with all its partners. CO 2 was successfully removed and captured for extended periods of time using three gas sources (NCCC Coal-fired Power plant, TCM CHP flue gas with and without CO 2 recycle, and TCM RFCC flue gas with air dilution) at various slipstream flows ranging from 0.5 MWe to 12 MWe. The data gathered on its solvent continues to strengthen the development of ION’s advanced solvent and positive track record in executing on-site test campaigns in highly industrialized settings. These existing pilot plants do not include the necessary process modifications that ION requires to obtain the lowest possible regeneration energy; processes such as a cold-rich bypass and intercooling, would allow for lowering the demonstrated specific reboiler duty. The resulting data was also used to validate the process model, and, in the absence of testing on a custom test rig specifically designed for ION’s advanced solvent, the results of the process model have shown specific reboiler duties under 2.5 MJ/kg CO 2 (1075 BTU/lb CO 2 ). When these regeneration energies are factored into the Techno-Economic Analysis (TEA), where ION’s technology is compared to the DOE/NETL BBS Case 12, which integrates a highly optimized and commercially available CO 2 capture technology, ION’s technology shows: 38% incremental reduction in capital cost of CO 2 capture; 28% incremental reduction in annual operating and maintenance costs of CO 2 capture; and $35-44 per tonne of CO 2 capture, which is a 20% to 40% reduction in cost of CO 2 capture. Throughout pilot testing, ION has confirmed its understanding of process improvements and analytics that will enable successful operation of its advanced solvent at significantly lower L/G circulation rates, packing heights and regeneration energies than MEA. ION has identified routes to further develop its technology and is looking forward to testing a fully optimized solvent and capture system in the near future.

01 COAL, LIGNITE, AND PEAT↗

Multi-Cycle Cesium Ion Exchange Testing Using Spherical Resorcinol-Formaldehyde Resin with Diluted Hanford Tank Waste 241-AP-105

Washington River Protection Solutions requested that at least 4 L of Hanford tank waste collected from tank 241-AP-105 and diluted to approximately 5.6 M Na (AP-105DF) be prepared for use in vitrification studies. Cesium removal was required to meet this objective and the waste pretreatment platform, established at Pacific Northwest National Laboratory, was used to create the vitrification feed. The Test Platform mimicked the Low-Activity Waste Pretreatment System (LAWPS) facility planned to pretreat Hanford tank waste supernate by removing solids in a cross flow filter apparatus and processing the supernate through ion exchange columns to remove cesium. At the time of testing, the ion exchange media was targeted to be spherical resorcinol-formaldehyde (SRF) resin. The SRF resin has been tested with a wide array of simulants and process scales, but column performance testing with actual tank waste had been somewhat limited to two Hanford tank wastes (AP-101 and AN-102) in up to two process cycles. This report describes testing conducted in a total of six load elute cycles with the AP-105DF tank waste. The column system was first tested with simulant and was previously described; this report describes the six process cycle results with the AP-105DF tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical and Scientific Report: Advanced Control of the Azura Wave Energy Device

The objective of the project was to develop a model predictive controller and associated hydraulic PTO for the Azura wave energy device to improve the annual energy production (AEP) and reduce the levelized cost of electricity (LCOE) of the device. Performance of the controller and hydraulic PTO were validated in a 1/15th scale wave tank test performed at the University of Maine. Three controllers, with three corresponding PTOs, were developed and tested as part of the project. The three controllers are an ideal MPC controller paired with an ideal PTO, an MPC controller with a heuristic paired with a directional force control hydraulic PTO, and a preliminary study of an MPC controller applied to a variable force hydraulic PTO. Experimental data was used to estimate the controller paired with the directional force control would increase the annual energy production of the Azura at WETS by 12%, with a corresponding reduction in LCOE of 10.8%. Preliminary testing of the variable force hydraulic PTO paired with a MPC shows this configuration has the potential to increase the AEP of the Azura at WETS by at least 33%. Further design and development work is necessary to develop the PTO technology to achieve these gains. Additionally, all control schemes require additional work to address the short-term wave prediction method needed to implement the control. In addition to validation of these control methods, NWEI demonstrated careful design of a wave tank test model, PTO, and instrumentation yields high quality test data, and the ability to test advanced control algorithms and include complex PTO dynamics via hardware-in-the-loop testing techniques.

16 TIDAL AND WAVE POWER↗

FY23 Drone RFID (Final Report)

The Drone RFID project successfully completed proof-of-concept testing to demonstrate the potential of a drone-based inventory system for high value remote materials at Los Alamos National Laboratory. Multiple drone platforms were procured, flight authorizations were received, and the vehicles were flown demonstrating what was initially perceived as the most difficult part of the project, successfully flying drones at the lab. Three commercial RFID inventory systems were also purchased, and ground testing performed to determine their suitability. Ultimately, one system was chosen for flight testing and successfully demonstrated the drone's ability to execute inventory with great potential for a relatively low-cost implementation.

42 ENGINEERING↗

Baseline tests of the AM General DJ-5E electruck electric delivery van

An electric quarter ton truck designed for use as a postal delivery vehicle was tested to characterize the state of the art of electric vehicles. Vehicle performance test results are presented. It is powered by a single-module, 54 volt industrial battery through a silicon controlled rectifier continuously adjustable controller with regenerative braking applied to a direct current compound wound motor.

Dustin, M. O.↗

Test and evaluation of a solar-heating system

Report documents results of evaluation tests performed on components of commerical solar heating and hot water system. Subsystems tested include flat plate solar collector, energy transport module, and control panel. Tests conducted include snow and wind loads, flame spread, and smoke classification as well as solar heating operation.

Source record↗

Applications of satellite data relay to problems of field seismology

A seismic signal processor was developed and tested for use with the NOAA-GOES satellite data collection system. Performance tests on recorded, as well as real time, short period signals indicate that the event recognition technique used is nearly perfect in its rejection of cultural signals and that data can be acquired in many swarm situations with the use of solid state buffer memories. Detailed circuit diagrams are provided. The design of a complete field data collection platform is discussed and the employment of data collection platforms in seismic network is reviewed.

Webster, W. J., Jr.↗

High-rate lithium thionyl chloride cells

A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.

Goebel, F.↗

A Study of Mars Dust Environment Simulation at NASA Johnson Space Center Energy Systems Test Area Resource Conversion Test Facility

The dust environment on Mars is planned to be simulated in a 20 foot thermal-vacuum chamber at the Johnson Space Center, Energy Systems Test Area Resource Conversion Test Facility in Houston, Texas. This vacuum chamber will be used to perform tests and study the interactions between the dust in Martian air and ISPP hardware. This project is to research, theorize, quantify, and document the Mars dust/wind environment needed for the 20 foot simulation chamber. This simulation work is to support the safety, endurance, and cost reduction of the hardware for the future missions. The Martian dust environment conditions is discussed. Two issues of Martian dust, (1) Dust Contamination related hazards, and (2) Dust Charging caused electrical hazards, are of our interest. The different methods of dust particles measurement are given. The design trade off and feasibility were studied. A glass bell jar system is used to evaluate various concepts for the Mars dust/wind environment simulation. It was observed that the external dust source injection is the best method to introduce the dust into the simulation system. The dust concentration of 30 Mg/M3 should be employed for preparing for the worst possible Martian atmosphere condition in the future. Two approaches thermal-panel shroud for the hardware conditioning are discussed. It is suggested the wind tunnel approach be used to study the dust charging characteristics then to be apply to the close-system cyclone approach. For the operation cost reduction purpose, a dehumidified ambient air could be used to replace the expensive CO2 mixture for some tests.

Chen, Yuan-Liang Albert↗

Pulmonary Toxicity Study of Lunar and Martian Dust Simulants Intratracheally Instilled in Mice

NASA is contemplating sending humans to Mars and the Moon for further exploration. The properties of Hawaiian and Californian volcanic ashes allow them to be used to simulate Martian and lunar dusts, respectively. NASA laboratories use these dust simulants to test performance of hardware destined for Martian or lunar environments. Workers in these test facilities are exposed to low levels of these dusts. The present study was conducted to investigate the toxicity of these dust simulants. Particles of respirable-size ranges of lunar simulant (LS), Martian simulant (MS), TiO2 (negative control) and quartz (positive control) were each intratracheally instilled (saline as vehicle) to groups of 4 mice (C57BL, male, 2-3 month old) at a single treatment of 1 (Hi dose) or 0.1 (Lo dose) mg/mouse. The lungs were harvested at the end of 7 days or 90 days for histopathological examination. Lungs of the LS-Lo groups had no evidence of inflammation, edema or fibrosis. The LS-Hi-7d group had mild to moderate acute inflammation, and neutrophilic and lymphocytic infiltration; the LS-Hi-90d group showed signs of chronic inflammation and some fibrosis. Lungs of the MS-Lo-7d group revealed mild inflammation and neutrophilic and lymphocytic infiltration; the MS-Lo-90d group showed mild fibrosis and particle-laden macrophages (PLM). Lungs of the MS-Hi-7d group demonstrated mild to moderate inflammation and large foci of PLM; the MS-Hi-90d group showed chronic mild to moderate inflammation and fibrosis. To mimic the effects of the oxidative and reactive properties of Martian soil surface, groups of mice were exposed to ozone (3 hour at 0.5 ppm) prior to MS dust instillation. Lung lesions in the MS group were more severe with the pretreatment. The results for the negative and positive controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of toxic insults to the lungs were TiO2<LS<MS<Quartz. For the mice in the 90-d study, blood samples were taken for immunotoxicity study. Antinuclear antibodies (such as those against Golgi, kinetichore, and centromere) were detected in serum in a greater extent in mice treated with LS than those with quartz, suggesting that LS, like quartz, has the potential of inducing antoimmune disease.

Lam, Chiu-Wing↗