In aqua vivo EPID dosimetry

Purpose: At the Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the original back-projection dose-reconstruction algorithm uses water-based scatter-correction kernels and therefore does not account for tissue inhomogeneities accurately. The aim of this study was to test a new method, in aqua vivo EPID dosimetry, for fast dose verification of lung cancer irradiations during actual patient treatment. Methods: The key feature of our method is the dose reconstruction in the patient from EPID images, obtained during the actual treatment, whereby the images have been converted to a situation as if the patient consisted entirely of water; hence, the method is termed in aqua vivo. This is done by multiplying the measured in vivo EPID image with the ratio of two digitally reconstructed transmission images for the unit-density and inhomogeneous tissue situation. For dose verification, a comparison is made with the calculated dose distribution with the inhomogeneity correction switched off. IMRT treatment verification is performed for each beam in 2D using a 2D {gamma} evaluation, while for the verification of volumetric-modulated arc therapy (VMAT) treatments in 3D a 3D {gamma} evaluation is applied using the same parameters (3%, 3 mm). The method was tested using two inhomogeneous phantoms simulating a tumor in lung and measuring its sensitivity for patient positioning errors. Subsequently five IMRT and five VMAT clinical lung cancer treatments were investigated, using both the conventional back-projection algorithm and the in aqua vivo method. The verification results of the in aqua vivo method were statistically analyzed for 751 lung cancer patients treated with IMRT and 50 lung cancer patients treated with VMAT. Results: The improvements by applying the in aqua vivo approach are considerable. The percentage of {gamma} values {<=}1 increased on average from 66.2% to 93.1% and from 43.6% to 97.5% for the IMRT and VMAT cases, respectively. The corresponding mean {gamma} value decreased from 0.99 to 0.43 for the IMRT cases and from 1.71 to 0.40 for the VMAT cases, which is similar to the accepted clinical values for the verification of IMRT treatments of prostate, rectum, and head-and-neck cancers. The deviation between the reconstructed and planned dose at the isocenter diminished on average from 5.3% to 0.5% for the VMAT patients and was almost the same, within 1%, for the IMRT cases. The in aqua vivo verification results for IMRT and VMAT treatments of a large group of patients had a mean {gamma} of approximately 0.5, a percentage of {gamma} values {<=}1 larger than 89%, and a difference of the isocenter dose value less than 1%. Conclusions: With the in aqua vivo approach for the verification of lung cancer treatments (IMRT and VMAT), we can achieve results with the same accuracy as obtained during in vivo EPID dosimetry of sites without large inhomogeneities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-P-33: Combining Research and Professional Practice in the Clinical Setting: A Medical Physicist Personal Experience

Purpose: To initiate a discussion on the current and evolving role of Medical Physicists based on author’s professional and research experience in patient safety and quality control. Methods: Several professionals of the departments of Medical Physics and Radiation Oncology, chiefly devoted to clinical tasks, began a research program on patient safety and quality control in a framework provided by the implementation of intraoperative radiotherapy (IORT). We performed studies on virtual simulation for IORT, in vivo dosimetry, failure mode and effect analysis (FMEA), statistical process control (SPC), and receiver operating characteristics of dosimetric equipment. This was done with the support of our research foundation and different grants while continuing with our departmental clinical routine involving about 1600 annual treatments with two linacs and different brachytherapy techniques. Results: We published 5 papers in international journals in the last two years. This author conducted a doctoral research which resulted in a dissertation in 2015. The extra time spent after treatments was essential to succeed. Funding and support achieved via our foundation played a crucial role; but this would have not been possible without punctual external mentoring and partnership. FMEA conclusions were able to be implemented only with staff commitment; however, conclusions concerning equipment cannot be easily communicated to manufacturers. These tasks required extra training in the appropriated methods. Conclusion: Research needed the support of a dedicated foundation, which would have been very difficult to obtain with the sole participation of our departments. FMEA and SPC results may need engagement of staff and manufacturers, respectively, hard to achieve without strong recommendations or even a regulatory framework. All these fields need evolution of Medical Physicists’ roles and additional training. Devotion to both clinical tasks and research could be unfeasible for Medical Physicists in the clinical setting without the appropriate rearrangement of their schedules and tasks. Supported by grants IPT-300000-2010-3 and PI11/01659. ERDF funds and Spanish Government.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-01: Dual Energy CT Proton Stopping Power Ratio Calibration and Validation with Animal Tissues

Purpose: The conversion of Hounsfield Unit (HU) to proton stopping power ratio (SPR) is a main source of uncertainty in proton therapy. In this study, the SPRs of animal tissues were measured and compared with prediction from dual energy CT (DECT) and single energy CT (SECT) calibrations. Methods: A stoichiometric calibration method for DECT was applied to predict the SPR using CT images acquired at 80 kVp and 140 kVp. The dual energy index was derived based on the HUs of the paired spectral images and used to calculate the SPRs of the materials. Tissue surrogates with known chemical compositions were used for calibration, and animal tissues (pig brain, liver, kidney; veal shank, muscle) were used for validation. The materials were irradiated with proton pencil beams, and SPRs were deduced from the residual proton range measured using a multi-layer ion chamber device. In addition, Gafchromic EBT3 films were used to measure the distal dose profiles after irradiation through the tissue samples and compared with those calculated by the treatment planning system using both DECT and SECT predicted SPRs. Results: The differences in SPR between DECT prediction and measurement were −0.31±0.36% for bone, 0.47±0.42% for brain, 0.67±0.15% for liver, 0.51±0.52% for kidney, and −0.96±0.15% for muscle. The corresponding results using SECT were 3.1±0.12%, 1.90±0.45%, −0.66±0.11%, 2.33±0.21%, and −1.70±0.17%. In the film measurements, average distances between film and calculated distal dose profiles were 0.35±0.12 mm for DECT calibration and −1.22±0.12 mm for SECT calibration for a beam with a range of 15.79 cm. Conclusion: Our study indicates that DECT is superior to SECT for proton SPR prediction and has the potential to reduce the range uncertainty to less than 2%. DECT may permit the use of tighter distal and proximal range uncertainty margins for treatment, thereby increasing the precision of proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamic parameters of helium under shock-wave and quasi-isentropic compressions at pressures up to 4800 GPa and compression ratios up to 900

The thermodynamic parameters of a strongly nonideal helium plasma obtained in experimental devices of hemispherical and spherical geometries are presented. Under shock-wave loading in the hemispherical device, the helium plasma was compressed to a density ρ ≈ 0.76 g cm{sup –3} by a pressure P ≈ 83 GPa at a temperature T ≈ 51000 K. Two-cascade spherical experimental devices of two types were used under quasi-isentropic helium plasma compression. In the devices of the first type at the same initial gas pressure in both cavities of the shells, the helium plasma was compressed approximately by a factor of 200 to a density ρ ≈ 8 g cm{sup –3} by a pressure P ≈ 4800 GPa. In the devices of the second type at a ratio of the initial gas pressures in the cavities of about 9: 1, the thermodynamic parameters of a nonideal helium plasma compressed by a factor of 900 to a density ρ ≈ 5 g cm{sup –3} by a pressure P ≈ 3700 GPa were determined. The compressed-plasma pressure was determined from the results of gasdynamic computations. An X-ray radiograph consisting of three betatrons and a multichannel optoelectronic X-ray imaging system was used to determine the positions of the boundaries of the gaseous-helium-compressing steel shell.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Readout system of TPC/MPD NICA project

The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noise charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Advanced Strategy Guideline: Air Distribution Basics and Duct Design

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amountof conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.

cesium ion exchange↗

Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on the SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.

Fire Safety↗

California Hydrogen Infrastructure Project

Air Products and Chemicals, Inc. has completed a comprehensive, multiyear project to demonstrate a hydrogen infrastructure in California. The specific primary objective of the project was to demonstrate a model of a real-world retail hydrogen infrastructure and acquire sufficient data within the project to assess the feasibility of achieving the nation's hydrogen infrastructure goals. The project helped to advance hydrogen station technology, including the vehicle-to-station fueling interface, through consumer experiences and feedback. By encompassing a variety of fuel cell vehicles, customer profiles and fueling experiences, this project was able to obtain a complete portrait of real market needs. The project also opened its stations to other qualified vehicle providers at the appropriate time to promote widespread use and gain even broader public understanding of a hydrogen infrastructure. The project engaged major energy companies to provide a fueling experience similar to traditional gasoline station sites to foster public acceptance of hydrogen. Work over the course of the project was focused in multiple areas. With respect to the equipment needed, technical design specifications (including both safety and operational considerations) were written, reviewed, and finalized. After finalizing individual equipment designs, complete station designs were started including process flow diagrams and systems safety reviews. Material quotes were obtained, and in some cases, depending on the project status and the lead time, equipment was placed on order and fabrication began. Consideration was given for expected vehicle usage and station capacity, standard features needed, and the ability to upgrade the station at a later date. In parallel with work on the equipment, discussions were started with various vehicle manufacturers to identify vehicle demand (short- and long-term needs). Discussions included identifying potential areas most suited for hydrogen fueling stations with a focus on safe, convenient, fast-fills. These potential areas were then compared to and overlaid with suitable sites from various energy companies and other potential station operators. Work continues to match vehicle needs with suitable fueling station locations. Once a specific site was identified, the necessary agreements could be completed with the station operator and expected station users. Detailed work could then begin on the site drawings, permits, safety procedures and training needs. Permanent stations were successfully installed in Irvine (delivered liquid hydrogen), Torrance (delivered pipeline hydrogen) and Fountain Valley (renewable hydrogen from anaerobic digester gas). Mobile fueling stations were also deployed to meet short-term fueling needs in Long Beach and Placerville. Once these stations were brought online, infrastructure data was collected and reported to DOE using Air Products Enterprise Remote Access Monitoring system. Feedback from station operators was incorporated to improve the station user's fueling experience.

08 HYDROGEN↗

Advanced Strategy Guideline: Air Distribution Basics and Duct Design

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The New Solar System: China’s Evolving Solar Industry and Its Implications for Competitive Solar Power in the United States and the World

Solar power is undergoing a revolution. Over the past decade, an energy source as old as the planet and theoretically all but limitless has plummeted in cost and begun in some places to be harnessed in large volume. This dynamic is disrupting the modern energy system and, as energy disruptions always do, rattling the geopolitical order. In the process, the industry that produces the equipment to convert sunlight into electricity is simultaneously reeling, consolidating, and surging. These twin transformations—one of the global energy system, one of the global solar industry—carry profound implications for national economies and for the planet. At the center of both transformations sits China. The New Solar System illuminates key and little- understood changes that are remaking the solar enterprise—in China and thus in the world. Based on this analysis, it recommends changes in U.S. solar policy—particularly timely with a new U.S. administration and Congress—that would put solar power on a more economically sensible path toward environmentally significant growth. The New Solar System does not seek to enable any country to beat another in the global solar industry. It seeks instead to help all countries find their most effective places. By better understanding and playing to their comparative strengths in the solar business, countries would achieve two key objectives. They would reduce the cost for the world of scaling up solar power. And they would be better positioned to fashion policies that maximized the long-term benefit to their own economies from solar’s global growth.

14 SOLAR ENERGY↗

Data Locality Enhancement of Dynamic Simulations for Exascale Computing (Final Report)

The development of modern processors exhibits two trends that complicate the optimizations of modern software. The first is the increasing sensitivity of processors' throughput to irregularities in computation. With more processors produced through a massive integration of simple cores, future systems will increasingly favor regular data-level parallel computations, but deviate from the needs of applications with complex patterns. Some evidences are already shown on Graphic Processing Units (GPU): Irregular data accesses (e.g., indirect references A[D[i]]) and conditional branches are limiting many GPU applications' performance at a level an order of magnitude lower than the peak of GPU. The second hardware trend is the growing gap between memory bandwidth and the aggregate speed—that is, the sum of all cores' computing power—of a Chip Multiprocessor (CMP). Despite the capped growth of the peak CPU speed, the aggregate speed of a CMP keeps increasing as more cores get into a single chip. It is expected that by 2018, node concurrency in an exascale system will increase by hundreds of times, whereas, memory bandwidth will expand by only 10 to 20 times. Consequently, data movement and storage is expected to consume more than 70% of the total system power. Bridging this gap is difficult; the complexities of modern CMP memory hierarchy make it even harder: Data cache becomes shared among computing units, and the sharing is often non-uniform—whether two computing units share a cache depends on their proximity and the level of the cache. On the recent IBM Power7 architecture, for instance, four hardware contexts (or SMT threads) in a core share the entire memory hierarchy, all cores in one chip share an on-chip L3 cache, and cores across chips share L3 and main memory through off-chip connections. These two trends complicate the translation of computing power into performance, especially for a program with either intensive data accesses or complex patterns in data accesses or control flow paths. Unfortunately, both attributes present and will persist in a class of important applications. For instance, many scientific simulations deal with a large volume of data. And meanwhile, as most real-world processes are non-uniform and evolving (e.g., the evolution of a galaxy or the process of a drug injection), both the computations and data accesses of these programs tend to be irregular and dynamically changing. Currently, the lack of support to these applications on modern CMP severely limits their performance. On GPU, as our recent study shows and other studies echo, performance enhancement of a factor of integers is possible when memory accesses or control flows are streamlined for a set of GPU applications. On multicore CPU, our studies show that traditional locality enhancement, for being oblivious to the new features of multicore memory hierarchy, may even cause large slowdown to data-intensive dynamic applications. The severity of the issues is expected to worsen as the two hardware trends continue. Some recent studies try to match software with the trends, but in a limited scope or manner. For irregularities on GPU, most studies focus on irregularities analyzable through static analysis (e.g., data accesses in regular loops). Dynamic irregularities are harder to address because the needed analysis and transformations typically have to happen at run time. Some other research resorts to hardware extensions, an actual adoption of which is unclear for the entailed space cost and complexity. For data locality, recent years have seen some exploitations of the new memory hierarchy on multicore for performance, but most of them are on process or thread scheduling, rather than program transformations. Our recent study reveals that program-level transformations may magnify the scheduling benefits by a factor of seven, concluding that program-level transformation should play a central role for data locality enhancement on modern CMP. But research in this direction has been sparse, and most have focused on data layout or cache performance modeling, rather than program transformations to match with the new memory hierarchy features. Overall, it is still an open question how to bridge the gap between dynamic computations and the two prominent properties of modern processors. The goal of this project is to develop a set of techniques and software tools to enhance the matching between memory accesses in dynamic simulations and the prominent features of modern and future CMP, alleviating the memory performance issues for petascale and exascale computing. This report summarizes the discoveries and products produced throughout this project. It includes free launch, a new software approach to overcoming the shortcomings of both methods; coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution; algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Supporting dynamic parallelism is important for GPU to benefit a broad range of applications. There are currently two fundamental ways for programs to exploit dynamic parallelism on GPU: a software-based approach with software-managed worklists, and a hardware-based approach through dynamic subkernel launches. Neither is satisfactory. The former is complicated to program and is often subject to some load imbalance; the latter suffers large runtime overhead. In this work, we propose free launch, a new software approach to overcoming the shortcomings of both methods. It allows programmers to use subkernel launches to express dynamic parallelism. It employs a novel compiler-based code transformation named subkernel launch removal to replace the subkernel launches with the reuse of parent threads. Coupled with an adaptive task assignment mechanism, the transformation reassigns the tasks in the subkernels to the parent threads with a good load balance. The technique requires no hardware extensions, immediately deployable on existing GPUs. It keeps the programming convenience of the subkernel launch-based approach while avoiding its large runtime overhead. Meanwhile, its superior load balancing makes it outperform manual worklist-based techniques by 3X on average. The work was published at the 48th Annual IEEE/ACM International Symposium on Microarchitecture (Micro'2015). A Graphic Processing Unit (GPU) system is typically equipped with many types of memory (e.g., global, constant, texture, shared, cache). Data placement determines what data are placed on which type of memory, essential for GPU memory performance. Prior optimizations of data placement always require a single view of a data object on memory, which limits the optimization effectiveness. In this work, we propose coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution. We demonstrate that under certain conditions, the multiple views can remain incoherent while facilitating enhanced data placement. We present a theorem and some compiler support to ensure the soundness of the usage of coherence-free multiview. We further develop reference-discerning data placement, a new way to enhance data placements on GPU. It enables more flexible data placements by using coherence-free multiview to leverage the slack in coherence requirement of some GPU programs. Experiments on three types of GPU systems show that, with less than 200KB space cost, the new data placement technique can provide a 1.6X average (up to 4.27X) speedup. In addition, we have examined algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Computing distances among data points is an essential part of many important algorithms in data analytics, graph analysis, and other domains. In each of these domains, developers have spent significant manual effort optimizing algorithms, often through novel applications of the triangle equality, in order to minimize the number of distance computations in the algorithms. In this work, we observe that many algorithms across these domains can be generalized as an instance of a generic distance-related abstraction. Based on this abstraction, we derive seven principles for correctly applying the triangular inequality to optimize distance-related algorithms. Guided by the findings, we develop Triangular OPtimizer (TOP), the first software framework that is able to automatically produce optimized algorithms that either matches or outperforms manually designed algorithms for solving distance-related problems. TOP achieves up to 237x speedups and 2.5X on average. The work has been published at the 32nd International Conference on Machine Learning (ICML'15) and the 41st International Conference on Very Large Data Bases (VLDB'15).

42 ENGINEERING↗

Blockchain Empowered Provenance Framework for Sensor Identity Management and Data Flow Security in Fossil-based Power Plants

The overall goals of this project are divided into 3 important phases. First, a peer-to-peer SCADA network is to be established where identity profile of sensors from fossil-power plants will be stored in an immutable manner in order to verify data flow integrity in real time. Second, it is aimed to develop a Blockchain-based provenance platform to audit equipment operations along with data and process integrity violations. In this phase, various operational rules will be incorporated in the ledger on behalf of the operating sensor so its abnormal use can be easily detected. In addition, it is aimed to achieve provenance when the rate of transactions is exceedingly high, thus enabling to design a scalable provenance scheme that can work in real time when number of data collecting points or sensor units increase in fossil-based power plants. Finally, a working testbed will be developed to integrate the Blockchain platform with sensor-based fossil power plant comprising of Remote Terminal Units (RTU) and SCADA devices. Using multiple Raspberry-PIs mimicking the role of RTUs that are interfaced with multiple sensors devices will be deployed to serve as a critical component of fossil power plant and the performance metrics such as throughput, latency, bootstrapping time, etc., will be evaluated on the testbed.

20 FOSSIL-FUELED POWER PLANTS↗

High Pressure and Two-Sided Mold Surface Solutions (CRADA Final Report)

This project provided surface solutions for highly loaded precision tooling relevant to the automotive industry. Previous development work in coatings for Big Area Additive Manufacturing (BAAM) has produced commercialized coatings for low temperature Acrylonitrile Butadiene Styrene (ABS) tools (TD Coat RT) as well as a soft coating for high temperature applications (TD Seal HT). The team developed these coatings and commercialized them during a prior Manufacturing Demonstration Facility (MDF) technical collaboration (NFE-15-05793). During the prior collaboration, commercialization testing was successfully performed by the Boeing and NAVAIR and resulted in an Awards for Composites Excellence (ACE), award at CAMX – The Composites and Advanced Materials Expo 2016. While this work was clearly successful, gaps in the technology were identified, that prevent widespread adoption of large-scale additive manufacturing in high pressure tooling applications prevalent in the automotive industry. In this project we focused on development of surface solutions for two-sided, compression molding tooling printed on a large-scale polymer AM system in an arbitrary build orientation. We have printed a single cavity extrusion compression molding mold using Polyphenylene sulfide/carbon fiber (PPS/CF) materials, 50% by weight CF samples. These processes are commonly used by Original Equipment Manufacturers (OEM) and Tier 1 suppliers for high volume automotive applications. Several OEMs have identified the need for such technology, indicating significant time and monetary savings could be possible if commercially available surface solutions for high pressure Additive Manufacturing (AM) tooling existed.

36 MATERIALS SCIENCE↗

Laser Welded Burst Disk Weld Tooling

A production run of 5550 hermetically sealed cylinder assemblies with precision pressure relief burst discs will be assembled and laser welded at a manufacturing lab at Sandia National Labs. Production of these cylinder assemblies requires many steps, including piece part machining, geometric inspection, cleaning, subassembly, complete assembly via laser welding, and finally leak checking. While this production run is large enough to invest in process optimization and specialized tooling, it is not quite large enough to dedicate new lab space and specify equipment specifically for this job. This study will investigate process parameters and their effects on quality and process flow time, as well as a fixturing design study with the goal of reducing process time while maintaining quality requirements.

42 ENGINEERING↗