Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DEMAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Leveling Intermittent Renewable Energy Production Through Biomass Gasification-Based Hybrid Systems

The increased use of intermittent renewable power in the United States is forcing utilities to manage increasingly complex supply and demand interactions. This paper evaluates biomass pathways for hydrogen production and how they can be integrated with renewable resources to improve the efficiency, reliability, dispatchability, and cost of other renewable technologies. Two hybrid concepts were analyzed that involve co-production of gaseous hydrogen and electric power from thermochemical biorefineries. Both of the concepts analyzed share the basic idea of combining intermittent wind-generated electricity with a biomass gasification plant. The systems were studied in detail for process feasibility and economic performance. The best performing system was estimated to produce hydrogen at a cost of $1.67/kg. The proposed hybrid systems seek to either fill energy shortfalls by supplying hydrogen to a peaking natural gas turbine or to absorb excess renewable power during low-demand hours. Direct leveling of intermittent renewable electricity production is accomplished with either an indirectly heated biomass gasifier, or a directly heated biomass gasifier. The indirect gasification concepts studied were found to be cost competitive in cases where value is placed on controlling carbon emissions. A carbon tax in the range of $26-40 per metric ton of CO{sub 2} equivalent (CO{sub 2}e) emission makes the systems studied cost competitive with steam methane reforming (SMR) to produce hydrogen. However, some additional value must be placed on energy peaking or sinking for these plants to be economically viable. The direct gasification concept studied replaces the air separation unit (ASU) with an electrolyzer bank and is unlikely to be cost competitive in the near future. High electrolyzer costs and wind power requirements make the hybridization difficult to justify economically without downsizing the system. Based on a direct replacement of the ASU with electrolyzers, hydrogen can be produced for $0.27 premium per kilogram. Additionally, if a non-renewable, grid-mix electricity is used, the hybrid system is found to be a net CO{sub 2}e emitter.

08 HYDROGEN↗

Preliminary Techno-Economic Assessment of Gas Switching Reforming (GSR) of Natural Gas for Pure Hydrogen Production and Power Generation with Integrated CO2 Capture

The increasing demand for hydrogen and the CO2 intensity of natural gas (NG) reforming motivate the development of low-carbon-emission hydrogen production technologies. Gas Switching Reforming (GSR) is an advanced auto-thermal reforming technology that produces hydrogen or syngas from natural gas. It integrates inherent CO2 capture by utilizing a specialized oxygen carrier in a single fluidized bed reactor, eliminating the need for complex, energy-intensive post-combustion separation. GSR technology builds upon Chemical Looping Reforming (CLR), an experimentally proven technology with strong potential for scaling up. In this study, select oxygen carriers (OC) (NiO/Al2O3, Fe2O3-CeO2/Al2O3, and magnetite) were tested in methane steam reforming in a fixed bed reactor to determine their relative reactivities under relevant conditions for GSR (800 °C, 7 bar total pressure). Process models were then developed to perform techno-economic analysis (TEA) of GSR for hydrogen production (GSR-H₂) and a combined cycle (GSR-CC) in which high-purity H₂ is fired in a gas turbine to produce electricity. Operating at 10 bar and 1100 °C and with the additional recovery steps implemented increased H₂ production by ~30% and improved efficiency relative to prior studies. For GSR-H₂, the levelized cost of hydrogen (LCOH) is 1.61–1.64 $/kg-H₂, competitive with a reference SMR case, though operating and maintenance costs are higher due to increased electricity demand. GSR-CC has a significantly higher levelized cost of electricity (LCOE) than its reference NGCC (natural gas combined cycle) plant, suggesting it is less competitive; however, increasing production scale could make it more attractive. Life-cycle results for GSR-H2 indicate NG consumption drives ~75% of total global warming impacts (~2.3 kg CO2 eq/kg H2). An environmental, health, and safety screening suggests iron-based carriers are comparatively safer, whereas NiO may pose greater risks. Overall, GSR-H2 is a scalable, competitive option for hydrogen production using nickel and non-nickel OC.

03 NATURAL GAS↗

Preliminary techno-economic assessment of gas switching reforming (GSR) of natural gas for pure hydrogen production and power generation with integrated CO2 capture

The increasing demand for hydrogen and the CO2 intensity of natural gas (NG) reforming motivate the development of low-carbon-emission hydrogen production technologies. Gas Switching Reforming (GSR) with integrated CO2 capture, a technology based on Chemical Looping Reforming (CLR), has been experimentally proven and shows potential for scale-up. In this study, select oxygen carriers (OC) (NiO/Al2O3, Fe2O3-CeO2/Al2O3, and magnetite) were tested in methane steam reforming in a fixed bed reactor to determine their relative reactivities under relevant conditions for GSR (800 °C, 7 bar total pressure). Process models were then developed to perform techno-economic analysis (TEA) of GSR for hydrogen production (GSR-H2) and a combined cycle (GSR-CC) in which high-purity H2 is fired in a gas turbine to produce electricity. Operating at 10 bar and 1100 °C and with the additional recovery steps implemented increased H2 production by ∼ 30% and improved efficiency relative to prior studies. For GSR-H2, the levelized cost of hydrogen (LCOH) is 1.61–1.64 $/kg-H2, competitive with a reference SMR case, though operating and maintenance costs are higher due to increased electricity demand. GSR-CC has a significantly higher levelized cost of electricity (LCOE) than its reference NGCC (natural gas combined cycle) plant, suggesting it is less competitive; however, increasing production scale could make it more attractive. Life-cycle results for GSR-H2 indicate NG consumption drives ∼ 75% of total global warming impacts (∼2.3 kg CO2 eq/kg H2). An environmental, health, and safety screening suggests iron-based carriers are comparatively safer, whereas NiO may pose greater risks. Overall, GSR-H2 is a scalable, competitive option for hydrogen production using nickel and non-nickel OC.

03 NATURAL GAS↗

TPSAS-NF1676L-19524-DND

Distributed propulsion is being proposed as an approach to achieve greater aircraft efficiency. An added benefit which might be realized with a distributed propulsion configuration is a reduction in radiated sound power. A reduction in radiated sound power could relieve concerns related to an increase in community noise that would accompany the adaptation of a fleet of many small aircraft fielded to meet increased travel demand. However, a reduction in radiated sound power does not necessarily translate into community acceptance of the new noise signature. Some characteristics of distributed propulsion configurations can create aural effects that people would find more annoying even though the sound is at a lower power level. To understand the community response to the new class of noise that a distributed propulsion system would present requires the prediction, synthesis and auralization of the noise in a controlled environment. Representative members of the community can then be exposed to the noise and queried for their reaction. These are the types of tests performed in NASA Langley’s Exterior Effects Room. This report summarizes preliminary results obtained using isolated propeller predictions. The sound pressure level of a single ‘large’ propeller is compared to that of two ‘smaller’ propellers of equivalent total thrust. The aural effects of different implementations of the two propellers are also considered. The different implementations include rotation direction and blade passage frequency separation.

Stephen A Rizzi↗

TPSAS-NF1676L-19003-DND

Distributed propulsion is being proposed as an approach to achieve greater aircraft efficiency. An added benefit which might be realized with a distributed propulsion configuration is a reduction in radiated sound power. A reduction in radiated sound power could relieve concerns related to an increase in community noise that would accompany the adaptation of a fleet of many small aircraft fielded to meet increased travel demand. However, a reduction in radiated sound power does not necessarily translate into community acceptance of the new noise signature. Some characteristics of distributed propulsion configurations can create aural effects that people would find more annoying even though the sound is at a lower power level. To understand the community response to the new class of noise that a distributed propulsion system would present requires the prediction, synthesis and auralization of the noise in a controlled environment. Representative members of the community can then be exposed to the noise and queried for their reaction. These are the types of tests performed in NASA Langley’s Exterior Effects Room. This report summarizes preliminary results obtained using isolated propeller predictions. The sound pressure level of a single ‘large’ propeller is compared to that of two ‘smaller’ propellers of equivalent total thrust. The aural effects of different implementations of the two propellers are also considered. The different implementations include rotation direction and blade passage frequency separation.

Daniel L Palumbo↗

TPSAS-NF1676L-17844-DND

Distributed propulsion is being proposed as an approach to achieve greater aircraft efficiency. An added benefit which might be realized with a distributed propulsion configuration is a reduction in radiated sound power. A reduction in radiated sound power could relieve concerns related to an increase in community noise that would accompany the adaptation of a fleet of many small aircraft fielded to meet increased travel demand. However, a reduction in radiated sound power does not necessarily translate into community acceptance of the new noise signature. Some characteristics of distributed propulsion configurations can create aural effects that people would find more annoying even though the sound is at a lower power level. To understand the community response to the new class of noise that a distributed propulsion system would present requires the prediction, synthesis and auralization of the noise in a controlled environment. Representative members of the community can then be exposed to the noise and queried for their reaction. These are the types of tests performed in NASA Langley’s Exterior Effects Room. This report summarizes preliminary results obtained using isolated propeller predictions. The sound pressure level of a single ‘large’ propeller is compared to that of two ‘smaller’ propellers of equivalent total thrust. The aural effects of different implementations of the two propellers are also considered. The different implementations include rotation direction and blade passage frequency separation.

Dan Palumbo↗

Systems and methods for controlling energy use during a demand limiting period

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental Flow Requirements from FERC Licenses Across the US

Environmental flow requirements included in Federal Energy Regulatory Commission (FERC) hydropower licenses are important for balancing natural properties and benefits of river ecosystems (e.g., healthy species, recreation, water supply, flood control) supporting hydropower production. In some cases, environmental flow requirements may limit operational flexibility given current operational schemes and make a hydropower plant less able to provide power to the electric grid on demand. Hydropower plants may gain some flexibility as hydropower scheduling time periods are made to be more responsive to the short-term needs of an energy grid increasingly reliant on intermittent renewables. However, many flow requirements focus on the daily, monthly, or seasonal flow fluctuations which matches the time scale of most paradigms linking flow alterations to the health of river ecosystems. This dataset seeks to provide a greater understanding of how flexibility in environmental requirements can be leveraged to create positive outcomes for both the power system and the environment. It contains information on environmental flow requirements from the Protection, Mitigation, and Enhancement section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The information on environmental flow requirements was extracted from the PM&E section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The flow requirements were then categorized into flow augmentation categories based on whether the license stated a specific water management purpose for the given requirement called augmentation categories (i.e., fisheries or habitat, recreation or boating, industry, and general or unspecified; Table B). Requirements were also grouped into flow type categories (e.g., minimum flow rate, maximum flow rate, ramping rate). Additional information related to flow requirements such as the augmentation time-period and whether the flow rate was continuous (i.e., condition must be present at all-times) or instantaneous (i.e., condition present at a point in time) was also extracted from the licenses. Some licenses had specific flow requirements based on whether the project was in a wet, dry, or normal water year. If that information was presented in the license, it was also included in the data set. The location within the project was noted, hereafter, zone, in the dataset for flow requirements relating to specific areas of hydropower projects (Dam, Powerhouse, Bypass Reach). Maximum discharge capacities of hydropower facilities were also extracted from both the Existing Hydropower Assets (EHA) data set and the National Inventory of Dams (NID) databases. Each facility was coded with project identification codes from the EHA dataset to facilitate cross-referencing between datasets.

13 HYDRO ENERGY↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Fine-Grained Application Energy and Power Measurements on the Frontier Exascale System

The increasing complexity and power/energy demands of heterogeneous exascale systems, such as the Frontier supercomputer, present significant challenges for measuring and optimizing power consumption in applications. Current tools either lack the resolution to capture fine-grained power and energy measurements, fail to validate in-band measurements against out-of-band power sensors, or cannot integrate this information with application performance events in a scalable manner. This paper introduces a novel open-source performance toolkit that integrates extended PAPI components with Score-P plugins to enable in-band, fine-grained power and energy measurements, while also supporting validation using power meter measurements for both CPUs and GPUs. One key contribution is the ability to perform millisecond-level power and energy measurements for AMD MI250X GPUs, mapping them to application performance events within a single trace and measurement system that scales. Our toolkit combines coarse-grained measurements from cray_pm counters with high-resolution metrics from rocm_smi and RAPL, converting GPU instantaneous accumulated energy into power to capture both transient and steady-state power behavior, a capability often missed by out-of-band and monitoring tools. By mapping these metrics to specific application regions, developers can identify energy hotspots, address inefficiencies in GPU kernel execution, and validate in-band measurements against external measurements. We demonstrate the effectiveness of this approach through case studies using benchmarks such as GPU rocblas_sgemm, BLIS c_blas_dgemm, and rocHPL, highlighting the variability of the measurements and the impact of transient power spikes on kernel-level efficiency.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

Loads as a Resource: Frequency Responsive Demand

Frequency control plays an important role in preserving the power balance of a multi-machine power system. Generators modify their power output when a non-zero frequency deviation is presented in order to restore power balance across the network. However, with plans for large-scale penetration of renewable energy resources, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive, but also technically difficult. Frequency control from the demand side or load control presents a novel and viable way for providing the desired frequency response. Loads can measure frequency locally and change their power consumption after a non-zero frequency deviation is presented in order to achieve power balance between generation and consumption. The specific objectives of this project are to: •Provide a framework to facilitate large-scale deployment of frequency responsive end-use devices •Systematically design decentralized frequency-based load control strategies for enhanced stability performance •Ensure applicability over wide range of operating conditions while accounting for unpredictable end-use behavior and physical device constraints •Test and validate control strategy using large-scale simulations and field demonstrations •Create a level-playing field for smart grid assets with conventional generators

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensemble of Thermostatically Controlled Loads: Statistical Physics Approach

Thermostatically Controlled Loads (TCL), e.g. air-conditioners and heaters, are by far the most wide-spread consumers of electricity. Normally the devices are calibrated to provide the so-called bang-bang control of temperature - changing from on to off , and vice versa, depending on temperature. Aggregation of a large group of similar devices into a statistical ensemble is considered, where the devices operate following the same dynamics subject to stochastic perturbations and randomized, Poisson on/off switching policy. We analyze, using theoretical and computational tools of statistical physics, how the ensemble relaxes to a stationary distribution and establish relation between the re- laxation and statistics of the probability flux, associated with devices' cycling in the mixed (discrete, switch on/off , and continuous, temperature) phase space. This allowed us to derive and analyze spec- trum of the non-equilibrium (detailed balance broken) statistical system. and uncover how switching policy affects oscillatory trend and speed of the relaxation. Relaxation of the ensemble is of a practical interest because it describes how the ensemble recovers from significant perturbations, e.g. forceful temporary switching o aimed at utilizing flexibility of the ensemble in providing "demand response" services relieving consumption temporarily to balance larger power grid. We discuss how the statistical analysis can guide further development of the emerging demand response technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Process Developed for Fabricating Engineered Pore Structures for High- Fuel-Utilization Solid Oxide Fuel Cells

Solid oxide fuel cells (SOFCs) have tremendous commercial potential because of their high efficiency, high energy density, and flexible fuel capability (ability to use fossil fuels). The drive for high-power-utilizing, ultrathin electrolytes (less than 10 microns), has placed an increased demand on the anode to provide structural support, yet allow sufficient fuel entry for sustained power generation. Concentration polarization, a condition where the fuel demand exceeds the supply, is evident in all commercial-based anode-supported cells, and it presents a significant roadblock to SOFC commercialization.

Sofie, Stephen W.↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Reliability and Resiliency in South Asia's Power Sector - Pathways for Research, Modeling, and Implementation

Reliability and resilience are the core principles of power system planning and operations around the world. Power systems in South Asia are transforming with increasing penetration of clean energy generation resources, emerging technologies, increasing electricity demand and electrification. At the same time, these power systems are facing challenges posed by extreme weather events and climate change. All these factors would add furthermore importance to the reliability and resilience of future power systems in South Asia. This has motivated us to better understand the country specific challenges and chalk out the pathways for research, modelling and implementation in South Asia. Our research, experience in the region and feedback from key stakeholders indicate following as the key areas where more work is needed to improve reliability and resilience of power systems in the region: Renewable energy Data for power system studies, New Tools and Studies, Resilience Planning, Resource Adequacy, Advanced RE Forecasting, Cybersecurity, Load Forecasting, and Coordinated Planning and Operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and Integration of Flexible Demand in Heat and Electricity Integrated Energy System

This paper is focused on utilizing customers' flexible energy demand, including both heat demand and electricity demand, to provide balancing resources and relieve the difficulties of integrating variable wind power with the combined heat and power. The integration of heat and electricity energy systems providing customers with multiple options for fulfilling their energy demand is described. Customer aggregators are introduced to supply downstream demand in the most economical way. Controlling customers' energy consumption behaviors enables aggregators to adjust their energy demand in response to supply conditions. Incorporating aggregators' flexible energy demand into the centralized energy dispatch model, a two-level optimization problem (TLOP) is first formed where the system operatormaximizes social welfare subject to aggregators' strategies, which minimize the energy purchase cost. Furthermore, the subproblems are linearized based on several reasonable assumptions. Optimal conditions of the subproblems are then transformed as energy demands to be described as explicit piecewise-linear functions of electricity prices corresponding to the demand bid curves. In this way, the TLOP is transformed to a standard optimization problem, which requires aggregators to only submit a demand bid to run the centralized energy dispatch program. All the parameters pertaining to the aggregators' energy consumption models are internalized in the bid curves. The proposed technique is illustrated in a modified testing system.

combined heat and power (CHP)↗