Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “O3”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Infrared spectroscopic measurements of tropospheric trace gases

Absorption features of several trace gases have been detected in 0.017-cm-resolution infrared spectra recorded over surface-level paths of 0.5 and 1.5 km at the National Solar Observatory on Kitt Peak, near Tucson, Arizona. Measurements of O3, HCOOH, NH3, and H2CO are briefly discussed.

Rinsland, Curtis P.↗

Improved spectroscopic line parameters for the ozone molecule

Recently available spectral O3 line parameters are summarized and progress in remote sensing based on these parameters is discussed. Particular attention is given to covering line positions, line intensities and linewidths for both the main isotopic species (O-16)3 and the isotopic variants (O-16)(O-18)(O-16) and (O-16)(O-16)(O-18).

Flaud, J.-M.↗

Calibration, testing and orbital performance of the halogen occultation experiment (HALOE) on the upper atmosphere research satellite

HALOE is an occultation viewing radiometer that requires part per million signal precision and characterization. Gas correlation radiometry is used to infer HF HCl, CH4 and NO concentrations, while broad band radiometry is used for temperature, pressure, O3, H2O and NO2. Validated results verify that goals have been met or exceeded in all channels. This was achieved through a comprehensive instrument analysis and calibration process on the ground and in orbit. Components and systems were put through a battery of tests in the lab. In orbit, a variety of exoatmospheric solar disk measurements are used for precise real time inferral of critical calibration parameters. In the end, technical success was based on the close interaction of scientist, engineer and data analysts. The accuracy and precision of HALOE species profiles are equal to any ever achieved from orbiting sensors.

Gordley, Larry L.↗

Cryogenic Limb Array Etalon Spectrometer (CLAES) - Experiment description

The CLAES measurement concept, instrument design, and performance are presented, and the scientific capabilities and measurement modes are discussed. The CLAES experiment involves remote measurement of earth-limb emission spectra. Characteristic vibration-rotation line spectral radiances are obtained between 3.5 and 13 microns and inverted through an iterative relaxation process to yield pressure, temperature, and species mixing ratio. The UARS limb-viewing instruments, including CLAES, combined with the 57-deg orbit inclination, allow for measurements to 80-deg latitudes. CLAES requires high spectral resolution and high radiometric sensitivity to isolate and accurately measure weak emissions from trace species such as HCl and NO against intense backgrounds from abundant emitters such as CO2, H2O, and O3. Accuracy and precision of retrieved quantities, observational modes, and calibration modes are also discussed.

Roche, Aidan E.↗

Stratospheric spectroscopy with the far-infrared spectrometer (FIRS-2) - Overview and recent results

The Smithsonian Astrophysical Observatory's program of balloon-borne stratospheric spectroscopic measurements is described, including instrumentation, recent scientific results, and future plans. The design and operation of the FIRS-2 far-infrared spectrometer is discussed. The current status of our efforts to recover mixing-ratio profiles with about 1 percent precision is presented. Representative recent results are shown giving mixing-ratio profiles from 20 to 50 km, selected from the suite HOCl, HCl, HF, NO2, N2O, HNO3, OH, HO2, H2O2, H2O (and isotopes), O2 (and isotopes), O3 (and isotopes), and CO2 (and isotopes). The utility of O2 and CO2 spectral lines for information on view angle or temperature and pressure is discussed. Future plans are mentioned, including the use of FIRS-2 on a balloon platform for UARS correlative measurements, the use of FIRS-2 on the NASA DC-8 platform for polar measurements, and the potential benefits of a FIRS instrument on a Shuttle platform.

Traub, Wesley A.↗

Measurement of atmospheric composition by the ATMOS instrument from Table Mountain Observatory

Following its first flight on board the Space Shuttle 'Challenger' as part of the Spacelab 3 payload, the Atmospheric Trace Molecule Spectroscopy (ATMOS) instrument has been operated at the Jet Propulsion Laboratory's Table Mountain Observatory (TMO; 34.4 deg N, 117.7 deg W, 2.23 km altitude) in the San Gabriel Mountains of Southern California. With the delay in the resumption of regular Shuttle flights, ATMOS has acquired a large number of high-quality, high-resolution infrared solar absorption spectra, spanning a period between late-1985 and mid-1990. These spectra are being analyzed to derive the column abundances of several atmospheric species including O3, HCl, HF, and HNO3. Although limited in temporal coverage, the preliminary results for these gases are discussed here in the context of the requirement and contribution to be made by similar instruments in detecting long term changes in stratospheric composition.

Gunson, Michael R.↗

Algorithms and sensitivity analyses for Stratospheric Aerosol and Gas Experiment II water vapor retrieval

The operational inversion algorithm used for the retrieval of the water-vapor vertical profiles from the Stratospheric Aerosol and Gas Experiment II (SAGE II) occultation data is presented. Unlike the algorithm used for the retrieval of aerosol, O3, and NO2, the water-vapor retrieval algorithm accounts for the nonlinear relationship between the concentration versus the broad-band absorption characteristics of water vapor. Problems related to the accuracy of the computational scheme, the accuracy of the removal of other interfering species, and the expected uncertainty of the retrieved profile are examined. Results are presented on the error analysis of the SAGE II water vapor retrieval, indicating that the SAGE II instrument produced good quality water vapor data.

Chu, W. P.↗

Atmospheric distribution and sources of nonmethane hydrocarbons

The paper discusses the atmospheric distribution of natural and man-made nonmethane hydrocarbons (NMHCs), the major species of airborne NMHCs, and their sources and sinks. Particular attention is given to the techniques for measuring atmospheric NMHCs; diurnal and seasonal variations of atmospheric NMHCs and differences between rural, urban, and marine environments; latitudinal and vertical distributions; and available stratospheric NMHC measurements. A formula defining the atmospheric lifetime of a NMHC from its reaction rates with OH and O3 is presented.

Singh, Hanwant B.↗

Stratospheric Wind Infrared Limb Sounder

The Stratospheric Wind Infrared Limb Sounder (SWIRLS), which measures wind, temperature, and the abundance of O3 and N2O in the stratosphere from earth orbit is selected as one of the complement of atmospheric sounders that will fly on the Earth Observing System B platform series. This paper outlines the SWIRLS investigation and describes laboratory experiments demonstrating SWIRLS wind measurement capabilities.

Rider, David M.↗

Aircraft laser infrared absorption spectrometer (ALIAS) for polar ozone studies

The ALIAS instrument is a very high resolution (0.0003/cm) scanning, tunable diode laser spectrometer designed to make direct, simultaneous measurements of NO2, HNO3, HCl, CH4, and either O3 or N2O (including vertical profiles of CH4 and N2O) in the polar stratosphere at sub-part-per-billion level sensitivities over integration times from 3 to 30 s. Unique features include a sample inlet/throttle system designed to achieve near-isokinetic sampling, in PSC events, an in-flight wavelength reference cell rack, mechanical fringe-spoilers, a four-laser/four-detector dewar with 24-hr hold-time operating at a fixed temperature without electrical regulation, and in-flight fast correlation routines for spectral drift compensation prior to spectral addition. Instrument design and test flight results are discussed in the light of ALIAS's role in the Winter 1991 Arctic aircraft stratospheric ozone campaigns out of Fairbanks, Alaska, and Bangor, Maine.

Webster, C. R.↗

Derivation of scaled surface reflectances from AVIRIS data

A method for retrieving 'scaled surface reflectances' assuming horizontal surfaces having Lambertian reflectances from spectral data collected by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is presented here. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94 micron and 1.14 micron water vapor absorption features. The transmission spectra of H2O, CO2, O3, N2O, CO, CH4, and O2 in the 0.4-2.5 micron region are simulated. The scattering effect due to atmospheric molecules and aerosols is modeled with the 5S computer code. The AVIRIS radiances are divided by solar irradiances above the atmosphere to obtain the apparent reflectances. The scaled surface reflectances are derived from the apparent reflectances using the simulated atmospheric gaseous transmittances and the simulated molecular and aerosol scattering data. The scaled surface reflectances differ from the real surface reflectances by a multiplicative factor. In order to convert the scaled surface reflectances into real surface reflectances, the slopes and aspects of the surfaces must be known.

Gao, Bo-Cai↗

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.↗

The cryogenic limb array etalon spectrometer (CLAES) on UARS - Experiment description and performance

The design and the performance of the cryogenic limb array spectrometer (CLAES) aboard the NASA Upper Atmosphere Research Satellite are discussed. CLAES measures altitude profiles of temperature, pressure, O3, H2O, CH4, N2O, NO, NO2, N2O5, HNO3, ClONO2, HCl, CFC 11, CFC 12, and aerosol absorption coefficients for atmospheric layer between 10 and 60 km. Examples of atmospheric spectral emission profiles for a number of constituents are presented as well as responsivity and noise parameters.

Roche, A. E.↗

The Halogen Occultation Experiment

The Halogen Occultation Experiment (HALOE) uses solar occultation to measure vertical profiles of O3, HCl, HF, CH4, H2O, NO, NO2, aerosol extinction, and temperature versus pressure with an instantaneous vertical field of view of 1.6 km at the earth limb. Latitudinal coverage is from 80 deg S to 80 deg N over the course of 1 year and includes extensive observations of the Antarctic region during spring. The altitude range of the measurements extends from about 15 km to about 60-130 km, depending on channel. Experiment operations have been essentially flawless, and all performance criteria either meet or exceed specifications. Internal data consistency checks, comparisons with correlative measurements, and qualitative comparisons with 1985 atmospheric trace molecule spectroscopy (ATMOS) results are in good agreement. Examples of pressure versus latitude cross sections and a global orthographic projection for the September 21 to October 15, 1992, period show the utility of CH4, HF, and H2O as tracers, the occurrence of dehydration in the Antarctic lower stratosphere, the presence of the water vapor hygropause in the tropics, evidence of Antarctic air in the tropics, the influence of Hadley tropical upwelling, and the first global distribution of HCl, HF, and NO throughout the stratosphere. Nitric oxide measurements extend through the lower thermosphere.

Russell, James M., III↗

Cryogenic limb array etalon spectrometer (CLAES) - Experiment description and initial results

The primary objective of the CLAES experiment is to measure the altitude profiles of temperature and of a series of minor and trace species important to stratospheric ozone layer photochemistry and radiative structure. Ways in which the species to be measured by CLAES are distributed among the broad categories of source, radical, and reservoir species involved in ozone production and loss are illustrated. CLAES requires high spectral resolution and high radiometric sensitivity to isolate and accurately measure weak emissions from trace species such as HCl and NO against intense backgrounds from abundant emitters such as CO2, H2O, and O3. Spectroscopy is performed by tilt scanning one of the four solid etalons between 0 and 23 deg in conjunction with one or more of the nine selectable discrete interference filters.

Roche, Aidan E.↗

Rate constants for the reactions of OH with HFC-134a (CF3CH2F) and HFC-134 (CHF2CHF2)

Measurements of rate constants for HFC-134 (CF2HCF2H) relative to CH3CCl3, HFC-125, and HFC-134a are reported. The measurements were made in a slow-flow, temperature controlled photochemical reactor, and were based on relative rates of disappearance of the parent compounds as measured by FTIR spectroscopy. Hydroxyl radicals were generated by 254-nm photolysis of O3 in the presence of water vapor. NASA/JPL rate constants for the reference compounds are used to derive temperature-dependent rate constants of both compounds. Rate constants obtained from the different reference compounds are in excellent agreement. The presently recommended rate constant for HFC-134a is about 25 percent too high.

Demore, W. B.↗

Airborne eddy correlation gas flux measurements - Design criteria for optical techniques

Although several methods exist for the determination of the flux of an atmospheric species, the airborne eddy correlation method has the advantage of providing direct flux measurements that are representative of regional spatial domains. The design criteria pertinent to the construction of chemical instrumentation suitable for use in airborne eddy correlation flux measurements are discussed. A brief overview of the advantages and limitations of the current instrumentation used to obtain flux measurements for CO, CH4, O3, CO2, and water vapor are given. The intended height of the measurement within the convective boundary layer is also shown to be an important design criteria. The sensitivity, or resolution, which is required in the measurement of a scalar species to obtain an adequate species flux measurement is discussed. The relationship between the species flux resolution and the more commonly stated instrumental resolution is developed and it is shown that the standard error of the flux estimate is a complicated function of the atmospheric variability and the averaging time that is used. The use of the recently proposed intermittent sampling method to determine the species flux is examined. The application of this technique may provide an opportunity to expand the suite of trace gases for which direct flux measurements are possible.

Ritter, John A.↗