Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Nuclear Fission Investigation with Twin Ionization Chamber

The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron tagging following atmospheric neutrino events in a water Cherenkov detector

We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218±9 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of SiC neutron sensor spectrum unfolding process based on Bayesian inference

This paper deals with SiC detector signal interpretation in neutron radiation measurements in mixed neutron gamma radiation fields, which is called the detector inverse problem or the spectrum unfolding, and it aims in finding a representation of the primary radiation, based on the measured detector signals. In our novel methodology we resort to Bayesian inference approach. In the developed procedure the resultant spectra is unfolded form detector channels reading, where the estimated neutron fluence in a group structure is obtained with its statistical characteristic comprising of standard deviation and correlation matrix. In the paper we present results of unfolding process for case of D-T neutron source in neutron moderating environment. Discussions of statistical properties of obtained results are presented as well as of the physical meaning of obtained correlation matrix of estimated group fluence. The presented works has been carried out within the I-SMART project, which is part of the KIC InnoEnergy R and D program. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RadMAP: The Radiological Multi-sensor Analysis Platform

The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. Here we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

47 OTHER INSTRUMENTATION↗

Calculational Model of the Radiation Calibration Lab (RCL) and the Neutron Measurements performed at the Facility, with a 252 Cf Source

Calibration of detectors measuring gamma, neutron, alpha and beta radiation, and of personal dosimeters used at Lawrence Livermore National Laboratory (LLNL), is performed at the Radiation Calibration Lab (RCL). The calibrations done with a standard calibrated 252 Cf source are a function of the energy spectra, fluence and dose of the source. A detailed calculational model of the RCL has been carried out with the MCNP6 code. The calculations have also reproduced quite well the measurements of the fluence and dose rates for the bare and moderated 252 Cf source carried out by R. Radev using the Rospec Spectrometer and by Clark and Wilson using a Passive Neutron Spectrometer. The importance of having the calculational model of the RCL facility is to calculate the dose rates expected for a given planned measurement, optimizing the choice of detectors, design and shielding materials before the actual measurement are carried out, resulting in a more efficient and time saving measurement. Furthermore, an accurate model of the facility allows to detect possible problems with the measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute measurement of the 242 Pu neutron-capture cross section

Here, the absolute neutron-capture cross section of 242 Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. The first direct measurement of the 242 Pu(n,γ) cross section was made over the incident neutron energy range from thermal to ≈ 6 keV, and the absolute scale of the (n,γ) cross section was set according to the known 239 Pu(n,f) resonance at E n,R = 7.83 eV. This was accomplished by adding a small quantity of 239 Pu to the 242 Pu sample. The relative scale of the cross section, with a range of four orders of magnitude, was determined for incident neutron energies from thermal to ≈ 40 keV. Our data, in general, are in agreement with previous measurements and those reported in ENDF/B-VII.1; the 242 Pu(n,γ) cross section at the E n,R = 2.68 eV resonance is within 2.4% of the evaluated value. However, discrepancies exist at higher energies; our data are ≈30% lower than the evaluated data at E n ≈ 1 keV and are approximately 2σ away from the previous measurement at E n ≈ 20 keV.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the Am 242 m neutron-induced reaction cross sections

The neutron-induced reaction cross sections of 242m Am were measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. A new neutron-capture cross section was determined, and the absolute scale was set according to a concurrent measurement of the well-known 242m Am(n,f) cross section. The (n,γ) cross section was measured from thermal energy to an incident energy of 1 eV at which point the data quality was limited by the reaction yield in the laboratory. Our new 242m Am fission cross section was normalized to ENDF/B-VII.1 to set the absolute scale, and it agreed well with the (n,f) cross section from thermal energy to 1 keV. Lastly, the average absolute capture-to-fission ratio was determined from thermal energy to E n = 0.1 eV, and it was found to be 26(4)% as opposed to the ratio of 19% from the ENDF/B-VII.1 evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First neutron spectroscopy measurements with a pixelated diamond detector at JET

A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order of magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of AmLi neutron sources for the LZ experiment

In this paper we describe the development, testing, and characterization of three low-emission rate AmLi neutron sources. The sources are used to calibrate the nuclear recoil response of the LUX-ZEPLIN (LZ) dark matter experiment. Furthermore, the sources' neutron emission rate was measured using 3He proportional tubes. The sources' gamma emissions were characterized using a high-purity germanium (HPGe) detector. Source-validated Geant4Monte Carlo simulations allowed to calibrate the Ge and neutron detectors' responses.

47 OTHER INSTRUMENTATION↗

Application of Triple Coincidence for the Detection of Small Amounts of Special Nuclear Materials

We constructed a device that measures two {gamma}-rays and one neutron from spontaneous fission and any resulting multiplication chains. It extends the associated particle technique based upon correlated counting of the multiplicity of gamma-rays and neutrons released in spontaneous- or neutron-induced fission. There are two advantages in incorporating a third detector in the design over the standard two-detector version. First, we found that random uncorrelated events dominate the background of coincident counting with a gamma-ray and neutron detector. These might be suppressed by requiring an additional coincidence. Second, the time history of gamma-ray emission between the two gamma-ray detectors is related to multiplication in the target media. Multiplication in highly enriched uranium is much greater than in depleted uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

Non-Statistical Effects in Neutron Capture

There have been many reports of non-statistical effects in neutron-capture measurements. However, reports of deviations of reduced-neutron-width ({gamma}{sub n}{sup 0}) distributions from the expected Porter-Thomas (PT) shape largely have been ignored. Most of these deviations have been reported for odd-A nuclides. Because reliable spin (J) assignments have been absent for most resonances for such nuclides, it is possible that reported deviations from PT might be due to incorrect J assignments. We recently developed a new method for measuring spins of neutron resonances by using the DANCE detector at the Los Alamos Neutron Science Center (LANSCE). Measurements made with a {sup 147}Sm sample allowed us to determine spins of almost all known resonances below 1 keV. Furthermore, analysis of these data revealed that the {gamma}{sub n}{sup 0} distribution was in good agreement with PT for resonances below 350 eV, but in disagreement with PT for resonances between 350 and 700 eV. Our previous (n,{alpha}) measurements had revealed that the {alpha} strength function also changes abruptly at this energy. There currently is no known explanation for these two non-statistical effects. Recently, we have developed another new method for determining the spins of neutron resonances. To implement this technique required a small change (to record pulse-height information for coincidence events) to a much simpler apparatus: A pair of C{sub 6}D{sub 6}{gamma}-ray detectors which we have employed for many years to measure neutron-capture cross sections at the Oak Ridge Electron Linear Accelerator (ORELA). Measurements with a {sup 95}Mo sample revealed that not only does the method work very well for determining spins, but it also makes possible parity assignments. Taken together, these new techniques at LANSCE and ORELA could be very useful for further elucidation of non-statistical effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collinear Cluster Tripartition as a Neutron Source--Evaluation of the Setup Parameters

Forthcoming experiments aimed at studying the mechanism of collinear cluster tripartition are planning to be performed with the new facility. Charged products will be registered with the double arm time-of-flight spectrometer composed of mosaics of PIN -diodes and MCP (micro channel plates) based timing detectors. Several tens of {sup 3}He-filled counters will be gathered round the {sup 252}Cf source. In order to choose an optimal configuration of the neutron detector and other parameters of the experiment special modeling has performed using both 'neutron barrel' and known MCNP code. The first test run of the new facility is in progress also its 'neutron skin' in under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Simulations for Geometric Optimization of a High-Energy Delayed Gamma Spectrometer for Direct Assay of Pu in Spent Nuclear Fuel

High-energy, beta-delayed gamma-ray spectroscopy is under investigation as part of the Next Generation Safeguard Initiative effort to develop non-destructive assay instruments for plutonium mass quantification in spent nuclear fuel assemblies. Results obtained to date indicate that individual isotope-specific signatures contained in the delayed gamma-ray spectra can potentially be used to quantify the total fissile content and individual weight fractions of fissile and fertile nuclides present in spent fuel. Adequate assay precision for inventory analysis can be obtained using a neutron generator of sufficient strength and currently available detection technology. In an attempt to optimize the geometric configuration and material composition for a delayed gamma measurement on spent fuel, the current study applies MCNPX, a Monte Carlo radiation transport code, in order to obtain the best signal-to-noise ratio. Results are presented for optimizing the neutron spectrum tailoring material, geometries to maximize thermal or fast fissions from a given neutron source, and detector location to allow an acceptable delayed gamma-ray signal while achieving a reasonable detector lifetime while operating in a high-energy neutron field. This work is supported in part by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.

Delayed Gamma Spectroscopy, active interrogation, ↗

Counts in the ORTEC Detective X neutron channel

The ORTEC Detective X is a new radiation detector being produced and sold by AMTEK ORTEC. The main detector (for gamma radiation energy) is a High Purity Germanium (HPGe) crystal. A Geiger-Müller (GM) tube is used for radiation exposure measurements above about 2 mR/hr. As an available option, a Li6 F/ZnS neutron detector module can be attached to the Detective X to measure neutrons.

61 RADIATION PROTECTION AND DOSIMETRY↗

miniTimeCube as a neutron scatter camera

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 – 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino detection, the mTC consists of 24 MultiChannel Plate (MCP) photodetectors surrounding a 13 cm cube of boron-doped plastic scintillator. Our simulation results show that waveform digitization of 1536 optically sensitive channels surrounding the scintillator should allow for spatiotemporal determination of individual neutron-proton scatters in the detector volume to ~ 100 picoseconds and ~5 mm. A Bayesian estimation framework is presented for multiple-scatter reconstruction, and is used to estimate the incoming direction and energy of simulated individual neutrons. Finally, we show how populations of reconstructed neutrons can be used to estimate the direction and energy spectrum of nearby simulated neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Interactions in the CUORE Neutrinoless Double Beta Decay Experiment

Neutrinoless double beta decay (0vDBD) is a lepton-number violating process that can occur only for a massive Majorana neutrino. The search for 0vDBD is currently the only practical experimental way to determine whether neutrinos are identical to their own antiparticles (Majorana neutrinos) or have distinct particle and anti-particle states (Dirac neutrinos). In addition, the observation of 0vDBD can provide information about the absolute mass scale of the neutrino. The Cuoricino experiment was a sensitive search for 0vDBD, as well as a proof of principle for the next generation experiment, CUORE. CUORE will search for 0vDBD of 130 Te with a ton-scale array of unenriched TeO 2 bolometers. By increasing mass and decreasing the background for 0vDBD, the half-life sensitivity of CUORE will be a factor of twenty better than that of Cuoricino. The site for both of these experiments is the Laboratori Nazionali del Gran Sasso, an underground laboratory with 3300 meters water equivalent rock overburden and a cosmic ray muon attenuation factor of 10 -6 . Because of the extreme low background requirements for CUORE, it is important that all potential sources of background in the 0vDBD peak region at 2530 keV are well understood. One potential source of background for CUORE comes from neutrons, which can be produced underground both by (α,n) reactions and by fast cosmic ray muon interactions. Preliminary simulations by the CUORE collaboration indicate that these backgrounds will be negligible for CUORE. However, in order to accurately simulate the expected neutron background, it is important to understand the cross sections for neutron interactions with detector materials. In order to help refine these simulations, I have measured the gamma-ray production cross sections for interactions of neutrons on the abundant stable isotopes of Te using the GEANIE detector array at the Los Alamos Neutron Science Center. In addition, I have used the GEANIE data to set an upper limit for the production of a 2529 keV gamma-ray from the 126 Te(n,n'γ) reaction. This gamma-ray is a potential source of interference for the 0vDBD peak. Based on this measurement, the contribution of this line to the background is expected to be negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron detection using a crystal ball calorimeter

The program of experiments of the A2 Collaboration performed on a beam of tagged photons of the MAMI electron microtron in Mainz (Germany) includes precision measurements of the total and differential cross sections of the pion photoproduction on neutrons of a deuterium target. The determination of the detector ability to detect neutrons is undoubtedly one of the important problems of the experiment. The calorimetric system of the detector contains a segmented NaI Crystal Ball detector, which gives information about the position, energy, and detection time of neutral and charged particles in a wide angular range. In this work, we describe the measurement of the neutron detection efficiency in the energy range from 20 to 400MeV. The results are compared with BNL data obtained on a pion beam and proton target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗