Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Combining multiple lower-fidelity models for emulating complex model responses for CCS environmental risk assessment

Numerical modeling is essential to support natural resource management and environmental policy-making. In the context of CO 2 geological sequestration, these models are indispensible parts of risk assessment tools. However, because of increasing complexity, modern numerical models require a great computational effort, which in some cases may be infeasible. An increasingly popular approach to overcome computational limitations is the use of surrogate models. This paper presents a new surrogate modeling approach to reduce the computational cost of running a complex, high-fidelity model. The approach is based on the simplification the high-fidelity model into computationally efficient, lower-fidelity models and on linking them with a mathematical function (linking function) that addresses the discrepancies between outputs from models with different levels of fidelity. The resulting linking function model, which can be developed with small computational effort, can be efficiently used in numerical applications where multiple runs of the original high-fidelity model are required, such as for uncertainty quantification or sensitivity analysis. The proposed approach was then applied to the development of a reduced order model for the prediction of groundwater quality impacts from CO 2 and brine leakage for the National Risk Assessment Partnership (NRAP) project.

54 ENVIRONMENTAL SCIENCES↗

Toxicity of Gamma Knife Radiosurgery in the Treatment of Intracranial Tumors in Patients With Collagen Vascular Diseases or Multiple Sclerosis

Purpose: To assess toxicity in patients with either a collagen vascular disease (CVD) or multiple sclerosis (MS) treated with intracranial radiosurgery. Methods and Materials: Between January 2004 and April 2009, 6 patients with MS and 14 patients with a CVD were treated with Gamma Knife radiosurgery (GKRS) for intracranial tumors. Treated lesions included 15 total brain metastases in 7 patients, 11 benign brain tumors, 1 low grade glioma, and 1 cavernous malformation. Toxicities were graded by the Radiation Therapy Oncology Group Acute/Late Radiation Morbidity Scoring Criteria. 'Rare toxicities' were characterized as those reported in the scientific literature at an incidence of <5%. Results: Median follow-up time was 16 months. Median dose to the tumor margin was 13.0 Gy (range, 12-21 Gy). Median size of tumor was 5.0 cm{sup 3} (range, 0.14-7.8 cm{sup 3}). Of the 14 patients with CVD, none experienced a Grade 3 or 4 toxicity or a toxicity characterized as rare. Of the 6 patients with MS, 3 experienced rare toxicities, and two of these were Grade 3 toxicities. Rare complications included a patient experiencing both communicating hydrocephalus and facial nerve palsy, as well as 2 additional patients with motor cranial nerve palsy. High-grade toxicities included the patient with an acoustic neuroma requiring ventriculoperitoneal shunt placement for obstructive hydrocephalus, and 1 patient with a facial nerve schwannoma who experienced permanent facial nerve palsy. Interval between radiosurgery and high-grade toxicities ranged from 1 week to 4 months. Conclusions: Our series suggests that patients with MS who receive GKRS may be at increased risk of rare and high-grade treatment-related toxicity. Given the time course of toxicity, treatment-related edema or demyelination represent potential mechanisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course

Purpose: To investigate the impact of primary tumor and involved lymph node (LN) geometry (centroid, shape, volume) on internal target volume (ITV) throughout treatment for locally advanced non-small cell lung cancer using weekly four-dimensional computed tomography (4DCT). Methods and Materials: Eleven patients with advanced non-small cell lung cancer were treated using image-guided radiotherapy with acquisition of weekly 10-Phase 4DCTs (n = 51). Initial ITV was based on planning 4DCT. Master-ITV incorporated target geometry across the entire treatment (all 4DCTs). Geographic miss was defined as the % Master-ITV positioned outside of the initial planning ITV after registration is complete. Registration strategies considered were bony (B), primary tumor soft tissue alone (T), and registration based on primary tumor and involved LNs (T{sub L}N). Results: The % geographic miss for the primary tumor, mediastinal, and hilar lymph nodes based on each registration strategy were (1) B: 30%, 30%, 30%; (2) T: 21%, 40%, 36%; and (3) T{sub L}N: 26%, 26%, 27%. Mean geographic expansions to encompass 100% of the primary tumor and involved LNs were 1.2 {+-} 0.7 cm and 0.8 {+-} 0.3 cm, respectively, for B and T{sub L}N. Primary and involved LN expansions were 0.7 {+-} 0.5 cm and 1.1 {+-} 0.5 cm for T. Conclusion: T is best for solitary targets. When treatments include primary tumor and LNs, B and T{sub L}N provide more comprehensive geographic coverage. We have identified high % geographic miss when considering multiple registration strategies. The dosimetric implications are the subject of future study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment

Purpose: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. Methods and Materials: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. Results: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 {+-} 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means ({mu}eff) +/- systematic ({Sigma}eff) intrafraction motion ({mu}{sub eff} {+-} {Sigma}{sub eff}) was 0.9 {+-} 1.1 mm and 0.6 {+-} 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion ({sigma}{sub eff}) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). Conclusion: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase I Study of Short-Course Accelerated Whole Brain Radiation Therapy for Multiple Brain Metastases

Purpose: To define the maximum tolerated dose (MTD) of a SHort-course Accelerated whole brain RadiatiON therapy (SHARON) in the treatment of patients with multiple brain metastases. Methods and Materials: A phase 1 trial in 4 dose-escalation steps was designed: 12 Gy (3 Gy per fraction), 14 Gy (3.5 Gy per fraction), 16 Gy (4 Gy per fraction), and 18 Gy (4.5 Gy per fraction). Eligibility criteria included patients with unfavorable recursive partitioning analysis (RPA) class > or =2 with at least 3 brain metastases or metastatic disease in more than 3 organ systems, and Eastern Cooperative Oncology Group (ECOG) performance status {<=}3. Treatment was delivered in 2 days with twice-daily fractionation. Patients were treated in cohorts of 6-12 to define the MTD. The dose-limiting toxicity (DLT) was defined as any acute toxicity {>=}grade 3, according to the Radiation Therapy Oncology Group scale. Information on the status of the main neurologic symptoms and quality of life were recorded. Results: Characteristics of the 49 enrolled patients were as follows: male/female, 30/19; median age, 66 years (range, 23-83 years). ECOG performance status was <3 in 46 patients (94%). Fourteen patients (29%) were considered to be in recursive partitioning analysis (RPA) class 3. Grade 1-2 acute neurologic (26.4%) and skin (18.3%) toxicities were recorded. Only 1 patient experienced DLT (neurologic grade 3 acute toxicity). With a median follow-up time of 5 months (range, 1-23 months), no late toxicities have been observed. Three weeks after treatment, 16 of 21 symptomatic patients showed an improvement or resolution of presenting symptoms (overall symptom response rate, 76.2%; confidence interval 0.95: 60.3-95.9%). Conclusions: Short-course accelerated radiation therapy in twice-daily fractions for 2 consecutive days is tolerated up to a total dose of 18 Gy. A phase 2 study has been planned to evaluate the efficacy on overall survival, symptom control, and quality of life indices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Freedom From Progression for Standard-Risk Medulloblastoma: A Mathematical Tumor Control Model With Multiple Modes of Failure

Purpose: As pediatric medulloblastoma (MB) is a relatively rare disease, it is important to extract the maximum information from trials and cohort studies. Here, a framework was developed for modeling tumor control with multiple modes of failure and time-to-progression for standard-risk MB, using published pattern of failure data. Methods and Materials: Outcome data for standard-risk MB published after 1990 with pattern of relapse information were used to fit a tumor control dose-response model addressing failures in both the high-dose boost volume and the elective craniospinal volume. Estimates of 5-year event-free survival from 2 large randomized MB trials were used to model the time-to-progression distribution. Uncertainty in freedom from progression (FFP) was estimated by Monte Carlo sampling over the statistical uncertainty in input data. Results: The estimated 5-year FFP (95% confidence intervals [CI]) for craniospinal doses of 15, 18, 24, and 36 Gy while maintaining 54 Gy to the posterior fossa was 77% (95% CI, 70%-81%), 78% (95% CI, 73%-81%), 79% (95% CI, 76%-82%), and 80% (95% CI, 77%-84%) respectively. The uncertainty in FFP was considerably larger for craniospinal doses below 18 Gy, reflecting the lack of data in the lower dose range. Conclusions: Estimates of tumor control and time-to-progression for standard-risk MB provides a data-driven setting for hypothesis generation or power calculations for prospective trials, taking the uncertainties into account. The presented methods can also be applied to incorporate further risk-stratification for example based on molecular biomarkers, when the necessary data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Grade Glioma Radiation Therapy Target Volumes and Patterns of Failure Obtained From Magnetic Resonance Imaging and {sup 18}F-FDOPA Positron Emission Tomography Delineations From Multiple Observers

Purpose: The objective of this study was to compare recurrent tumor locations after radiation therapy with pretreatment delineations of high-grade gliomas from magnetic resonance imaging (MRI) and 3,4-dihydroxy-6-[{sup 18}F]fluoro-L-phenylalanine ({sup 18}F-FDOPA) positron emission tomography (PET) using contours delineated by multiple observers. Methods and Materials: Nineteen patients with newly diagnosed high-grade gliomas underwent computed tomography (CT), gadolinium contrast-enhanced MRI, and {sup 18}F-FDOPA PET/CT. The image sets (CT, MRI, and PET/CT) were registered, and 5 observers contoured gross tumor volumes (GTVs) using MRI and PET. Consensus contours were obtained by simultaneous truth and performance level estimation (STAPLE). Interobserver variability was quantified by the percentage of volume overlap. Recurrent tumor locations after radiation therapy were contoured by each observer using CT or MRI. Consensus recurrence contours were obtained with STAPLE. Results: The mean interobserver volume overlap for PET GTVs (42% ± 22%) and MRI GTVs (41% ± 22%) was not significantly different (P=.67). The mean consensus volume was significantly larger for PET GTVs (58.6 ± 52.4 cm{sup 3}) than for MRI GTVs (30.8 ± 26.0 cm{sup 3}, P=.003). More than 95% of the consensus recurrence volume was within the 95% isodose surface for 11 of 12 (92%) cases with recurrent tumor imaging. Ten (91%) of these cases extended beyond the PET GTV, and 9 (82%) were contained within a 2-cm margin on the MRI GTV. One recurrence (8%) was located outside the 95% isodose surface. Conclusions: High-grade glioma contours obtained with {sup 18}F-FDOPA PET had similar interobserver agreement to volumes obtained with MRI. Although PET-based consensus target volumes were larger than MRI-based volumes, treatment planning using PET-based volumes may not have yielded better treatment outcomes, given that all but 1 recurrence extended beyond the PET GTV and most were contained by a 2-cm margin on the MRI GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Single- versus Multiple-Fraction Palliative Radiation Therapy for Bone Metastases: Population-Based Analysis of 16,898 Courses in a Canadian Province

Purpose: There is abundant evidence that a single fraction (SF) of palliative radiation therapy (RT) for bone metastases is equivalent to more protracted and costly multiple fraction courses. Despite this, there is low utilization of SFRT internationally. We sought to determine the utilization of SFRT in a population-based, publicly funded health care system. Methods and Materials: All consecutive patients with bone metastases treated with RT during 2007 to 2011 in British Columbia (BC) were identified. Associations between utilization of SFRT and patient and provider characteristics were investigated. Results: A total of 16,898 courses of RT were delivered to 8601 patients. SFRT was prescribed 49% of the time. There were positive relationships among SFRT utilization and primary tumor group (P<.001; most commonly in prostate cancer), worse prognosis (P<.001), increasing physician experience (P<.001), site of metastases (P<.001; least for spine metastases), and area of training (P<.001; most commonly for oncologists trained in the United Kingdom). There was wide variation in the prescription of SFRT across 5 regional cancer centers, ranging from 25.5% to 73.4%, which persisted after controlling for other, potentially confounding factors (P<.001). Conclusions: The large variability in SFRT utilization across BC Cancer Agency (BCCA) cancer centers suggests there is a strong cultural effect, where physicians' use of SFRT is influenced by their colleagues' practice. SFRT use in BC was similar to that in other Canadian and western European reports but strikingly higher than in the United States. Further work is needed to standardize SFRT prescribing practices internationally for this common indication for RT, with the potential for huge health system cost savings and substantial improvements in patients' quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do Coordinated Knowledge Translation Campaigns Persuade Radiation Oncologists to Use Single-Fraction Radiation Therapy Compared With Multiple-Fraction Radiation Therapy for Bone Metastases?

Although level 1 evidence supports the use of single-fraction radiation therapy (SFRT) compared with multiple-fraction radiation therapy (MFRT) for the palliative management of bone metastases, SFRT is underused. In early 2017, the Canadian Partnership Against Cancer and CancerCare Manitoba undertook a comprehensive knowledge translation campaign in Manitoba, Canada featuring educational outreach visits, local consensus meetings, and audit and feedback interventions to encourage greater use of SFRT. This study assessed the impact of this campaign on SFRT use and identified variables associated with MFRT usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A cost-effective differential mobility analyzer (cDMA) for multiple DMA column applications

In aerosol research and applications, a differential mobility analyzer (DMA) is now considered the standard tool for sizing and classifying monodisperse particles in the sub-micrometer and nanometer size ranges. However, DMA application at the pilot or industrial production scale remains infeasible because of the low mass throughput. A simple way to scale up DMA operation is to use multiple DMA columns. The manufacture and maintenance costs of existing DMAs, however, limit such a scale-up. A cost-effective DMA column (named cDMA) has thus been developed in this work to address the above issue. To reduce its manufacturing cost, the prototype was constructed using parts requiring little machining. The cDMA column was also designed for easy maintenance and easy variation of the classification length for any application-specified size range. In this study, prototypes with two particle classification lengths, 1.75 and 4.50 cm, were constructed and their performance was experimentally evaluated at sheath-to-aerosol flowrate ratios of 5:1, 10:1, and 15:1 via the tandem DMA (TDMA) technique. It was concluded that both prototype cDMAs, operated at a sheath/aerosol flowrate ratio less than 15:1 and with a polydisperse aerosol flowrate of 1.0 lpm, achieved sizing resolution comparable to that offered by Nano-DMA. The longer cDMA had comparable transmission efficiency to that of Nano-DMA, and the shorter cDMA exceeded the performance of Nano-DMA. Hence, the cDMA with the shorter (1.75 cm) classification length is better suited for the characterization of macromolecular samples.

54 ENVIRONMENTAL SCIENCES↗

Efficient bi-directional coupling of 3D computational fluid-particle dynamics and 1D Multiple Path Particle Dosimetry lung models for multiscale modeling of aerosol dosimetry

The development of predictive aerosol dosimetry models has been a major focus of environmental toxicology and pharmaceutical health research for decades. One-dimensional (1D) models successfully predict overall deposition averages but fail to accurately predict local deposition. Computational fluid-particle dynamics (CFPD) models provide site-specific predictions but at a computational cost that prohibits whole lung predictions. Thus, there is a need for developing multiscale strategies to provide a realistic subject-specific picture of the fate of inhaled aerosol in the lungs. CT-based 3D/CFPD models of the large airways were bidirectionally coupled with individualized 1D Navier-Stokes airflow and particle transport based upon the widely used Multiple Path Particle Dosimetry Model (MPPD). Distribution of airflows among lobes was adjusted by measured lobar volume changes observed in CT images between FRC and FRC + 1.5 L. Additionally, as a test of the effectiveness of the coupling procedures, deposition modeling of previous 1 µm aerosol exposure studies was performed. The complete coupled model was run for 3 breaths, with the computation-intense portion being the 3D CFD Lagrangian particle tracking calculation. The average deposition per breath was 11% in the combined multiscale model with site-specific doses available in the CFPD portion of the model and airway- or region-specific deposition available for the MPPD portion. In conclusion, the key methods developed in this study enable predictions of ventilation heterogeneities and aerosol deposition across the lungs that are not captured by 3D or 1D models alone. Overall, these methods can be used as the foundation for multi-scale modeling of the full respiratory system.

60 APPLIED LIFE SCIENCES↗

Modeling aerosol bolus inhalations in the human lung with the multiple path particle deposition model: Comparison with experimental data

Existing one-dimensional (1D) models of aerosol dosimetry often ignore mixing mechanisms of inhaled aerosols during their transport in the lung. This mixing or aerosol dispersion results from different physical mechanisms in different regions of the lung. It is a higher order effect, which cannot be directly captured in 1D modeling approaches, and thus is sometimes modeled as a diffusive process. Here, in this study, we improved our recently developed alveolar mixing module incorporated in the multiple path particle dosimetry model (MPPD) to account for flow irreversibility and particle trapping in the alveolar spaces, as well as mixing occurring in the tracheobronchial region. This new version of MPPD was coupled with CFPD-based predictions of aerosol bolus dispersion in the oral airway. The model was used to predict the deposition, dispersion, and mode shift of aerosol bolus inhaled at different penetration depths within the lung for breathing patterns and particle size matching those used in a previous experimental study (Darquenne et al., 2016). Even though a quite simplified approach was used, the computations appear to describe subject-specific and test-specific experimental data reasonably well. The proposed combined dispersion-deposition model can be a useful tool for targeted drug delivery and also for exposure health risk assessment.

MPPD↗

MarK, a Novosphingobium aromaticivorans kinase required for catabolism of multiple aromatic monomers

The aromatic compounds used in a variety of industrial products are currently obtained from nonrenewable petroleum sources. Alternatively, the plant polymer lignin is an abundant renewable source of aromatics, and its depolymerization generates a variety of products that can include acetovanillone, a vanillin derivative containing an acetyl side chain. The Alphaproteobacterium Novosphingobium aromaticivorans DSM12444 can metabolize several chemically modified aromatics in deconstructed lignin, but not acetovanillone. In this work, adaptive laboratory evolution identified a single amino acid change in the previously uncharacterized gene product Saro_1862 that is necessary and sufficient for N. aromaticivorans growth with acetovanillone as a sole growth substrate, as well as other aromatic monomers not metabolized by wild-type cells. We show that a glutamate (E) to lysine (K) substitution at amino acid residue 16 of Saro_1862 results in a ~1600-fold increase in the rate of ATP-dependent acetovanillone phosphorylation. We also find that recombinant Saro_1862 E16K phosphorylates several other aromatic compounds in vitro , defining the first reported catalytic activity for the widespread UPF0261 protein domain contained in Saro_1862. Thus, we propose naming Saro_1862 MarK, for multiple aromatic kinase. A 1.57 Å crystal structure of MarK E16K predicts that the E16K substitution lies in a potential ATP binding site, suggesting how this amino acid change increased catalytic activity. A search for homologs of MarK and other proteins required for acetovanillone degradation predicts that this pathway for aromatic metabolism exists throughout the bacterial phylogeny.

Novosphingobium↗

Evaluation of multiple tracer methods to estimate low groundwater flow velocities

Here, four different tracer methods were used to estimate groundwater flow velocity at a multiple-well site in the saturated alluvium south of Yucca Mountain, Nevada: (1) two single-well tracer tests with different rest or “shut-in” periods, (2) a cross-hole tracer test with an extended flow interruption, (3) a comparison of two tracer decay curves in an injection borehole with and without pumping of a downgradient well, and (4) a natural-gradient tracer test. Such tracer methods are potentially very useful for estimating groundwater velocities when hydraulic gradients are flat (and hence uncertain) and also when water level and hydraulic conductivity data are sparse, both of which were the case at this test location. The purpose of the study was to evaluate the first three methods for their ability to provide reasonable estimates of relatively low groundwater flow velocities in such low-hydraulic-gradient environments. The natural-gradient method is generally considered to be the most robust and direct method, so it was used to provide a “ground truth” velocity estimate. However, this method usually requires several wells, so it is often not practical in systems with large depths to groundwater and correspondingly high well installation costs. The fact that a successful natural gradient test was conducted at the test location offered a unique opportunity to compare the flow velocity estimates obtained by the more easily deployed and lower risk methods with the ground-truth natural-gradient method. The groundwater flow velocity estimates from the four methods agreed very well with each other, suggesting that the first three methods all provided reasonably good estimates of groundwater flow velocity at the site. We discuss the advantages and disadvantages of the different methods, as well as some of the uncertainties associated with them.

58 GEOSCIENCES↗

Photoactivatable fluorescent probes reveal heterogeneous nanoparticle permeation through biological gels at multiple scales

Diffusion through biological gels is crucial for effective drug delivery using nanoparticles. Here, we demonstrate a new method to measure diffusivity over a large range of length scales – from tens of nanometers to tens of micrometers – using photoactivatable fluorescent nanoparticle probes. We have applied this method to investigate the length-scale dependent mobility of nanoparticles in fibrin gels and in sputum from patients with cystic fibrosis (CF). Nanoparticles composed of poly(lactic-co-glycolic acid), with polyethylene glycol coatings to resist bioadhesion, were internally labeled with caged rhodamine to make the particles photoactivatable. We activated particles within a region of sample using brief, targeted exposure to UV light, uncaging the rhodamine and causing the particles in that region to become fluorescent. We imaged the subsequent spatiotemporal evolution in fluorescence intensity and observed the collective particle diffusion over tens of minutes and tens of micrometers. We also performed complementary multiple particle tracking experiments on the same particles, extending significantly the range over which particle motion and its heterogeneity can be observed. In fibrin gels, both methods showed an immobile fraction of particles and a mobile fraction that diffused over all measured length scales. In the CF sputum, particle diffusion was spatially heterogeneous and locally anisotropic but nevertheless typically led to unbounded transport extending tens of micrometers within tens of minutes. Lastly, these findings provide insight into the mesoscale architecture of these gels and its role in setting their permeability on physiologically relevant length scales, pointing toward strategies for improving nanoparticle drug delivery.

36 MATERIALS SCIENCE↗